Great video! Is it possible to make the pump turn on when water level gets too high to pump out the water and stop when the water level is low? Thank you
Why you did connect the float switch to the N line of the contactor control circuit instead of the L line? What's the difference between each connection?
Looks like your switching the Neutral to to operate the Contactor Coil. In New Zealand Wrong, Neutral is not switched at all, so only Single Pole Circuit breaker and contactor used. You would use a Control C.B. as well
Hi, I’m looking to make this. Could you help me understand how to do that? My email id is rohit.286@gmail.com I’d be really grateful to you for your help! TIA
It appears you are breaking the N and not the L, would also recommend an isolated low voltage control circuit. Where is your coil contacts, I assume they are the two on top otherwise you would have a short, I.E where is A1 A2 coil terminals.
Can such a floating switch control two separate pump at same time , like NO to stop pumping and NC to start pumping (to use common for both pumps and NC for one pump and NO to control another pump)?
I'm not really familiar with the MCB thing. I have a 1HP 12.2/6.0-6.1A 115/208-230V air compressor pump. It has a black wire, a white wire, and a green wire. I *think* it is 2 hots and a ground. It currently connects to a D-box float switch with a lever that is moved by a rod with a float on the end. Unfortunately, it keeps getting jammed & keeps the pump running so it overflows the cistern. I want to have the pump turn on when the water is low and off when the water is high. I get L= live (hot), N= neutral & green is ground. So, it looks like the power supply wires connect to the MCB but ground goes directly to the pump but I'm slightly confused about the red wire from the MCB. Is it spliced? Why does it seem to go further in to the contactor than the other wires? Is it connecting at a different point? Is the blue wire also spliced with a black lead to go to the black? wire of the float switch? Also, what about that unconnected red wire on the float switch? Does it just say disconnected? Is the MCB really necessary?
بیٹری اور سولر سے خود موبائیل چارجر بنانا How to make 12 volt DC Mobile charger. कैसे बनाये 12 वोल्ट डीसी मोबाइल चार्जर ua-cam.com/video/iLMjHmyCOB0/v-deo.html
They are series of events in logic boards and calls and labyrinths chain of command series of events calls .................................................I still don't have matatu fare office number
Thanks for watching ❤👍
Please subscribe this youtube channel to watch more important videos like this..
@Salman khan Mon
low water level blue and black connected. high water level also blue and black connected.. so, when the water pump should on and off?
@@atanlap low level: blue and black, the pump is on. High level: the pump is off automatically. The blue-black connection remain.
Thank you
Excellent simple to follow video !! THANK YOU !!
This is very educative, thanks for sharing it with us...
Thank you so much!! Your video helped me figure out the wiring for a project I was making.
Explanation with circuit is appreciable. Circuit with components is also appreciable.
Beautiful video sharing
Thank you.❤👍❤
Thanks for sharing it with us
Excellent 🙏
Thank you.❤👍❤
Nice 👍
❤👍❤
Fantastic information sir.
Thank you.❤👍
Good work sir
Nice video its really help me 🙏 please boss of how to connect my pump with two fload switch thanks
Very nice.....
Thank you❤
Merci beaucoup pour votre aide
Great video! Is it possible to make the pump turn on when water level gets too high to pump out the water and stop when the water level is low?
Thank you
That would be more useful and just what I need too.
Yes, you need to wife the float switch opposite as in the video.
Thanks a lot dear excellence explained
Why you did connect the float switch to the N line of the contactor control circuit instead of the L line? What's the difference between each connection?
I’m also having that same doubt in my mind
Yes. Same here wth doubt.. Whyy??
because it is safer!
@@hawre95 tq for the reply.👍👍
This diagram make we thingking over
This is for single phase pump.. can 3 phase pump apply the same for the float switch installation?
What is the MCB amp and Magnetic Contactor amp?..
Thank you
Looks like your switching the Neutral to to operate the Contactor Coil. In New Zealand Wrong, Neutral is not switched at all, so only Single Pole Circuit breaker and contactor used. You would use a Control C.B. as well
Hi, I’m looking to make this. Could you help me understand how to do that? My email id is rohit.286@gmail.com
I’d be really grateful to you for your help! TIA
Yes In My country we not use this diagram but ... inside bideou diagram controller function as well
Thnx ❤️👍
❤👍
It appears you are breaking the N and not the L, would also recommend an isolated low voltage control circuit. Where is your coil contacts, I assume they are the two on top otherwise you would have a short, I.E where is A1 A2 coil terminals.
Thanks bro
Can such a floating switch control two separate pump at same time , like NO to stop pumping and NC to start pumping (to use common for both pumps and NC for one pump and NO to control another pump)?
Yes aslo can sir
Kon se app use karta ho hand animation driving bna na k lya tell me please .
is it the same for line to line connection?
Thanks
2:12 thanks
gud day sir what if my waterbpumpbis submersible then i did not ise a magnetic contactor, instead i directly put the float switch directly?
hi
i got problem
my relay making chattering sound some time high some time Low.
Let me know is this worry thing?
Try cleaning the contacts with a nail file or fine file
Is it safe to use float switch in water tank? Is there any possibility of electric leakage?
Also about uv sensor
May I please know the specs of the magnetic contactor single phase and where to buy it? Your response will be greatly appreciated.
Its not advisable to have AC.supply in the water no doubt the floatswitch is compact,it could result in shock due to leakage
I'm not really familiar with the MCB thing. I have a 1HP 12.2/6.0-6.1A 115/208-230V air compressor pump. It has a black wire, a white wire, and a green wire. I *think* it is 2 hots and a ground. It currently connects to a D-box float switch with a lever that is moved by a rod with a float on the end. Unfortunately, it keeps getting jammed & keeps the pump running so it overflows the cistern. I want to have the pump turn on when the water is low and off when the water is high.
I get L= live (hot), N= neutral & green is ground. So, it looks like the power supply wires connect to the MCB but ground goes directly to the pump but I'm slightly confused about the red wire from the MCB. Is it spliced? Why does it seem to go further in to the contactor than the other wires? Is it connecting at a different point? Is the blue wire also spliced with a black lead to go to the black? wire of the float switch? Also, what about that unconnected red wire on the float switch? Does it just say disconnected? Is the MCB really necessary?
Black = power
White = neutral
Green = ground
That's the color designation of US wiring
ஸ்பீச் ஓட இருந்தா நல்லா இருக்கும் இதைவிட
Sir a single pole single fuse. contactor se ho sakta hai kiya.
would you be a sport and share the PN of these contactors?
hello, thanks for the video. Which animation program did you prepare the video with?
where can i buy such a equipment ??
GOOD
Contactor model and amazon link please. And can we mount this contactor in wall
What will be problems if i not use relay switch and want to connect directly in motor pump???
Γνωρίζει κανείς πως μπορούμε να συνδέσωμε τριφασικό βάτραχο σε φωτοβολταϊκά; Ευχαριστώ πολύ.
5ampere current edukkunnu switch on aakumbol thanney pinney work cheyumbol athreyilla enth cheyaam
Good afternoon which program you use to animate your classes, because I need to give classes to my students.
💪💪💪💪
❤👍👍
👍👍👍👍
what is the specification of this contactor? Thank you
Paano po kung ang soply ng tubig galing ng water distric, walang motor,,paano po cocontrolin ang tubig pag puno na
Excelentes vídeo.
O problema é que não é português.
liquid level control
Please give me a three phase connection video
Amazon link to buy magnetic contactor and float please
I hope the connection was wrong definitely .Sir
Why we have to use contactor? We can directly connect the phase line to float switch right
I expect to avoid electric shock in case of water leakage in the floating part
Magnetic contactor link
Solar pump controller on Etsy
I think it will not work, Where is A1 & A2 connection, & why do you connected L, N both to float switch.
Make me thinkinh over
Supert
220 v not safe, use 24 v dc relay
بیٹری اور سولر سے خود موبائیل چارجر بنانا
How to make 12 volt DC Mobile charger. कैसे बनाये 12 वोल्ट डीसी मोबाइल चार्जर
ua-cam.com/video/iLMjHmyCOB0/v-deo.html
ফ্লট সুইচ এর দম কতো?
Subtitle pls
Teria aulas em português
මේ විස්තර සින්හලෙන් දාන්න..
They are series of events in logic boards and calls and labyrinths chain of command series of events calls .................................................I still don't have matatu fare office number