  • @FluxCondenser
    @FluxCondenser  3 роки тому +11

    I’ve created an Amazon shopping list for everything you’ll need to build this dim bulb current limiter. You can order the parts from my Amazon affiliate page: www.amazon.com/shop/fluxcondenservintageaudioelectronics?tag=onamzfluxcond-20&linkCode=ic7

    • @teekay_1
      @teekay_1 3 роки тому

      The parts list is missing. Perhaps something changed?

    • @fredashay
      @fredashay 2 роки тому

      Can you give me some advice?
      I've been looking for a true power isolation device for years -- not just a transformer and surge combination.
      Something more like a 120VAC motor connected to a 120VAC alternator with an insulated axle so the output voltage is truly isolated electrically from the mains.
      Does something like this even exist?
      I haven't been able to find anything like it despite countless searches.

    • @SDsailor7
      @SDsailor7 11 місяців тому

      Why is it necessary to remove the break off
      tab from the switch? and what if the switch does not have a break off tab on it? then what do i do?
      Thank you, very interesting video and also informative👍

    • @montygibbon1905
      @montygibbon1905 8 місяців тому

      @FluxCondenser Would you consider building & uplosding a bucking transformer?
      (For the purpose of knocking down AU & UK voltages from 250v to a China friendly 220v and/or from 120v to 110v.)

  • @richferraro4422
    @richferraro4422 2 роки тому +5

    IMHO this is the best (and slickest) current limiter I’ve seen. So nice and compact. My voltage meter doesn’t kick in until 34V is reached which is probably normal and not a problem. Thank You for posting this professionally done video!

  • @weschilton
    @weschilton 2 роки тому +2

    I just built this current limiter yesterday. I can't thank you enough for this really well-presented video. My switched outlet was completely different than the way your was set up (yay standards!) but it was pretty easy to confirm the connections with my multimeter and, with the final testing to confirm the circuit, the build came together in a leisurely hour... including testing it with my variac.
    My friend handed me a valuable vintage amp to repair, and now I feel confident turning it on without blowing it up!

  • @junolanding558
    @junolanding558 Рік тому

    Good set up. The best of the 4 I've seen so far. Thanks

  • @kevinanderson7613
    @kevinanderson7613 2 роки тому +3

    I love this design. I viewed quite a few videos and online guides and this was the best I found. I built one based on your plans, it looks great! I appreciate the quality of your videos!

  • @donaldpingitore9000
    @donaldpingitore9000 2 роки тому +1

    Completed mine today. Happy that I have added it to my bench.

  • @1pilotsteve
    @1pilotsteve Рік тому +1

    I just built mine.... exactly how you said... Ultra Mint and works great... Thanks for all your videos.. I wish I had a teacher like you in School.

  • @randallbarnett4048
    @randallbarnett4048 3 роки тому +1

    I made a dim bulb current limiter by buying and following your instructions. Thank you for this informative video.

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Fantastic, Randall! Gald to hear that. My pleasure.

  • @btinsen
    @btinsen Рік тому

    Nice clean simple but effective design. I ordered everything through your link. Works great! Thanks!

  • @IrwinCespedes
    @IrwinCespedes 3 роки тому +1

    My father used to make these as tools in a more empyrical way when he owned a sound system for parties and small concerts. He used to use this tool to check when amplifiers didn't work. Nice memories! Excellent video, you should let viewers send you pics of it already done!

    • @FluxCondenser
      @FluxCondenser  3 роки тому +1

      Thanks Irwin, and thanks for sharing those memories. Great idea! If anyone wants to send a pic of their build let me know and I’ll be sure to publish it.

  • @Johns-lp9en
    @Johns-lp9en 3 роки тому +2

    Thank you do much for providing this video! I built it, used it, and it worked perfectly.

  • @ETG168
    @ETG168 2 роки тому +25

    Important: Do NOT solder wires that are going to be clamped down in some manner. The solder will cold-form over time, causing a bad connection and possibly a fire hazard. Instead, twist the wire together well, and if using a screw terminal like on an outlet, bend it in the same direction as the screw will turn when fastening, usually clockwise. This way, instead of pushing the wire out when you tighten the screw, it will instead be clamped down. Even better, if available, you can use a crimpable fork terminal for an even more secure connection.

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      Huh? No soldering was shown or advised in this video.

    • @LelleKidd
      @LelleKidd 2 роки тому +7

      @@FluxCondenser 4:00

    • @TheCheesyRice
      @TheCheesyRice Рік тому +8

      @@FluxCondenser I think he means where you tinned the leads

    • @greebo7857
      @greebo7857 29 днів тому

      Had a house fire from exactly that. "Hard" joints heat up, harden more, heat up... rinse and repeat.

  • @sjlBoise54
    @sjlBoise54 3 роки тому +2

    Best dim bulb video - only requires one outlet/fixture box.
    The plug-in bulb socket is brilliant and simple (most use a separate junction box and a surface fixture), as is the voltmeter.

    • @FluxCondenser
      @FluxCondenser  3 роки тому +1

      Thanks, Stephen.

    • @MartinFahsel
      @MartinFahsel 6 місяців тому +1

      @@FluxCondenser I completely agree! I just bought the parts to build and, since I have ample three-prong power cords, came in below your cost. Thank you and I have subscribed to your feed.

  • @niaceri1
    @niaceri1 2 роки тому +6

    Thank you so much for doing this. The instructions were extremely clear, and the parts list (and numbers) very helpful. I completed my build this morning. All works well!! Now if I could just find a way to stop my KT88 SE amplifier's Power Transformer from buzzing! 🙂

    • @Movieman1965
      @Movieman1965 6 місяців тому

      I saw on another video post that the transformer laminated plates could be loose. Look for the video on YT.

  • @triplefoam
    @triplefoam Рік тому

    A great video, if not one of the best for a DIY dim bulb tester. In the 70's my dad and I used a hanging switched mechanics shop light reconfigured with a plug for the device in his TV and Stereo repair shop.

  • @crimsonghost6454
    @crimsonghost6454 3 роки тому +2

    Thank you again for another great video. This is an important subject and tool. The way you demonstrated it and explained it was perfect. Love your videos.

  • @beanmeup9902
    @beanmeup9902 8 місяців тому +1

    Brilliant! Bravo Sir!

  • @andydelle4509
    @andydelle4509 3 роки тому +6

    I built mine a bit differently. I used a split duplex outlet (break the tab on the brass screws) and a double pole switch (HD & Lowes have these too). The lightbulb (or 6amp Edison base fuse) plugs into one outlet side, the device under test into the other, both interchangeable, wired in series. The double pole switch ensures both sides of the AC line are disconnected when off. I know the neutral is grounded at the service but just a little extra safety. I also put in a 1/2in neon "power on" indicator. Since those "plugin" bulb sockets are cheap, I have a few with 40, 100, 200 watt bulbs already installed. I do like your plastic box. The less grounded metal on the bench, the better.

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Thanks for sharing your build, Andy. There are a lot of ways to go about it depending on what the user is looking for.

    • @JoeJ-8282
      @JoeJ-8282 3 роки тому +1

      If you build one that way using only one duplex outlet, then you also have to break the tab on the other side of the outlet also and then use a jumper wire from the neutral terminal of the first outlet to the hot terminal of the second outlet before finally going back to neutral from the second outlet, otherwise you end up with reversed polarity on the second outlet, which is of course a dangerous shock hazard when testing certain equipment that has the neutral connected to the chassis, because with reversed polarity on the DUT outlet then you end up with hot being sent to the chassis of some older equipment!

    • @andydelle4509
      @andydelle4509 3 роки тому

      @@JoeJ-8282 True, but you shouldn't be working in hot chassis equipment without an isolation transformer. I do have one and put it in front of the dim bulb tester if working on hot chassis gear. That would include modern switching power supplies. And safety issues aside, even with the chassis on the neutral you still have a problem with the neutral wire impedance back to the main panel where it ties to the service ground. This is more than enough to cause significant measurement errors with grounded test gear..

    • @JoeJ-8282
      @JoeJ-8282 3 роки тому

      @@andydelle4509 I don't think you understand what I mean when I refer to "hot" going to the chassis of the equipment. There is NO piece of manufacturer built equipment that deliberately wires the hot lead to the chassis, (that would be just plain stupid and a major safety and even fire hazard!), but when I said you may eventually get shocked by having the hot on the chassis, due to the NEUTRAL lead of the power cord of some older equipment being connected to the chassis in certain circuit designs, and then your outlet box of your dim bulb tester, (with the way you have it wired), sending hot onto the neutral lead of the equipment being tested, because it backfeeds THROUGH the bulb itself on the bulb's neutral side, and then, (unless you have BOTH metal connecting tabs on your duplex test outlet broken off AND you wire it as I mentioned earlier, above), then you have the neutral side of the bulb outlet, (which essentially has the hot lead of incoming power on it because it feeds through the bulb first), you have that then going directly to the neutral side of the equipment to be tested outlet, which is not good, because then the hot can get back onto the chassis of the equipment under test on the neutral side of the equipment's power cord! That is why it is essential for best safety to wire the test box duplex outlet as I said in my first comment to prevent the polarity reversal on the second, (DUT), outlet...
      Now an isolation transformer will help with the danger of that and you getting majorly shocked as a result of having the test outlet wired backwards, but it won't be as safe as it could and would be if your test outlet was wired properly in the first place. In order for any electrical power sources to be totally connected in series, you must wire hot to first device, (bulb), then neutral of that to the HOT of the 2nd device, (DUT outlet), and then the neutral of the 2nd device/outlet back to the power source neutral, but that is ONLY possible, (i.e. with the correct polarity on BOTH outlets), IF BOTH metal connecting tabs on both sides of the duplex outlet of your test box are broken off/separated, and then you wire the neutral screw of the 1st outlet to the hot screw of the 2nd outlet with a jumper wire instead...
      Think of it kind of like a flashlight with 2 batteries in it. In order for a proper series connection to happen you must have the 2 batteries connected + to - in the middle, otherwise the circuit won't work. (Maybe that's not the best analogy, but hopefully you can see the resemblance, even though the voltages are totally different, along with it being DC in batteries, and AC with this tester we're talking about), but even AC has a polarity to it in relation to ground, as you prob. already know, and the hot side can be quite dangerous to touch in most cases. In the case of you always using an isolation transformer, that alone has saved you from getting majorly shocked with your test device as it is wired, but you wouldn't even NEED an isolation transformer in the first place to be safe if your test outlet box was wired as I suggested in the first comment.
      Anyway, I hope you can understand WHY I'm suggesting that you should change the wiring around on your tester's second outlet, because the way you have it now is ultimately not totally safe to use, and if you or anyone else was to ever use it as it is without the isolation transformer then you could potentially get injured, but if you fix the wiring to be like I described in my first comment then it wouldn't really matter if you used an isolation transformer or not, because it would then be safe either way, at least provided that the device you're testing also has a polarized plug, which most do. Of course you still CAN use an isolation transformer in either case, for the ultimate in safety and isolation, but if the wiring in your test box was properly fixed then it wouldn't be absolutely necessary for prevention of shocks, it would just then be more for the equipment's sake.
      I'm not trying to diss on your overall design at all, I'm only trying to help you make it a safer design for your sake!

    • @andydelle4509
      @andydelle4509 3 роки тому +1

      @@JoeJ-8282 I am an EE of 40 years. I fully understand what you are proposing and may even do it. It's a simple fix. My career has also involved work on broadcast transmitters and large UPS systems. I am fully versed on deadly voltages and current.
      But no audio gear above an old table radio uses a hot chassis any more. "Hot chassis" is an industry term for tying one side of AC line to the chassis or signal ground. It does not necessarily mean to tie the hot side to the chassis. Some pre-1980s TVs still used hot chassis as they needed a cheap source of over 100 volts anyway for some of the circuits. But in any transformer or switch mode power supply fed device, the chassis ground is isolated from BOTH sides of the AC line.
      But once inside any gear, you should use an isolation transformer. Especially today in that many switch mode power supplies are build on the same PC board as the rest of the electronics to keep costs down. You have many exposed internal components that may be direct to the AC line, both sides.
      You also can't assume the wall outlet is wired properly. It's quite common to find them reversed as well.
      Most videos here show dim bulb testers with open terminal pony sockets mounted on plywood. Talk about safety hazards!

  • @PrimeHiFi
    @PrimeHiFi 3 роки тому +2

    Fantastic video. I will follow this for when I make my own. It’s one of the last tools my bench is missing

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Thanks, Connor. Good luck with the build. It’s a fun, simple and rewarding little project.

    • @PrimeHiFi
      @PrimeHiFi 3 роки тому +1

      @@FluxCondenser just finished the dim bulb tester today and it worked like a charm! I’ll be sure to purchase the volt meter through your Amazon store tomorrow. Thanks for the hours of entertainment and helpful videos. It really helps beginners like me out! Much appreciated :)

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      @@PrimeHiFi Thanks for the support and kind words, Connor. Glad the dim bulb tester came out well. Take care!

  • @kirkdegler6516
    @kirkdegler6516 2 роки тому

    Thanks for sharing this. Definitely among the cleaner and safer designs I've seen. Built one following along to your video.

  • @edgancarcik8856
    @edgancarcik8856 2 роки тому

    Thanks for the great video. I was able to sneak in a filtered IEC power connector on bottom portion of case. Makes for easier storage and I also find that the common mode filtered front end helps keeps AC power noise levels from swamping front AM bands. Dimmer switches are horrible noise sources !!!!!!!!

  • @willardthompson6648
    @willardthompson6648 Рік тому

    Love this design! Built one but had to buy a 1/2" box and 3/8" strain relief. Fit tight enough I didn't have to glue. Press fit. Good luck finding the 150 watt incandescent bulb.

  • @SwanseaTitanFan
    @SwanseaTitanFan 3 роки тому +2

    Thanks for this. Groovy music.

  • @cdavidhord
    @cdavidhord 3 роки тому +1

    I love this channel!

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      And this channel loves you, man! Thanks again for your continued support, Dave.

  • @SD-nj1cy
    @SD-nj1cy Місяць тому

    @FluxCondenser - I built one and it worked perfectly. I no longer need it to work as a limiter. How do i change the wiring so i can use it a switched 3 outlet extension cord ? Thanks in advance

  • @uptownphotography
    @uptownphotography 2 роки тому +1

    Well done and very well explained...I am in the market for a Variac, (for guitar amplifiers), so I will watch that video next. Thanks.
    Phil
    NYC area

  • @flossflink
    @flossflink 3 роки тому +1

    nice, clean build!

  • @eddomanowski4566
    @eddomanowski4566 Рік тому

    Thank you very much for the instructions on the dim it's been very helpful although I do have a question about the digital voltmeter mine doesn't seem to match with the multimeter it's coming up 116 in the multimeter says $120 is that a common thing with these dm55

  • @jamescowan7940
    @jamescowan7940 2 роки тому +2

    I don't see the switched outlet you list on the Amazon parts list as the same in the video. There isn't a gold connection to make the jumper.

    • @kirchgoens
      @kirchgoens 9 днів тому

      I’m having the same problem. The switched outlet he linked in the parts list is not the one he used. The list switch has no black screws and fewer total screws.

  • @MicSokol
    @MicSokol Рік тому

    Great project, I was thinking to do the same. I wish you have shown a short circuit.

  • @groovy1937
    @groovy1937 Рік тому

    I like this dim bulb tester or limiter!!!

  • @sushimaster100
    @sushimaster100 3 роки тому

    Very nice, well explained, and to the point. Not too difficult to follow. Subscribed.

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      That’s about the best testimonial I could ever hope for. Thanks so much, Armstrong. And welcome!

  • @JoeJ-8282
    @JoeJ-8282 3 роки тому +7

    In case you didn't know about it, there is a special glue-in adapter available at Lowes or Home Depot, (or most other electrical supply stores), that you can use with that PVC box that has a rubber insert in the end that has a hole in it that's the same diameter as the round power cord, along with a threaded ring that tightens down onto it so the cord doesn't pull out. It is specifically designed for cords of this round type, and it is an even neater, more professional looking way to do the cord strain relief, and it works just as well as (or even better than), the black push in cable clamp that was used here in this video, except that with the glue-in one you don't have to modify the box hole at all first, you just glue it in with some conduit or PVC glue. The black cable clamp that was used in this video is made specifically for Romex wires going into a metal enclosure such as a breaker panel box.

    • @rul1175
      @rul1175 Рік тому

      What is it called???

  • @jefflapoint2195
    @jefflapoint2195 3 роки тому

    Great design and video. I made one, works great! I changed the bulb to a miniature 100w spot light to save some space. I love the volt meter addition, I would not have thought about it and its cheap.

  • @jordanrussell345
    @jordanrussell345 Рік тому

    What wire stripper are you using?

  • @olegg9339
    @olegg9339 25 днів тому

    I have a question, why do you break off the metal switched outlet tab? It will just change on/off swither polarity. I think you could connect hot wire to the white screw at the top right avoiding the jumper cable from top left to the bottom right by using the metal tab connector.

  • @jocool7370
    @jocool7370 Рік тому

    Thanks for the video! I've just replicated this build to great success.

  • @richardadelberg8961
    @richardadelberg8961 3 роки тому +1

    I’m still stuck with parts ordered from your Amazon kit because the switch and outlet don’t have three screws on either side!! So get to 3 rd to I don’t know where to run wire?

  • @levi2bear
    @levi2bear 3 роки тому +3

    Mr. Condenser you videos are very informative and excellently presented. I wonder if you could be so kind as to recommend an isolation transformer or perhaps the appropriate specifications for one. I will say aging you have the gift of making the complex understandable, Many thanks.

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Thanks! The Tripp Lite isolation transformers seem quite good. There are three models available which are similar but have the following different wattage ratings: 250W, 500W, 1000. The higher wattage units are naturally more expensive. For most radios and basic stereo equipment, the 250 watt unit may be fine. If you’re dealing with larger amps, etc., you’ll need to go higher depending on your needs. Figure out the wattage of the most demanding device you’ll have on your bench and go from there. A little extra cushion wouldn’t hurt. Remember that these units don’t isolate the ground, so if you need that, use a simple cheater plug. Tripp Lite isolation transformers are available on Amazon, and you can find more info here: www.tripplite.com/products/isolation-transformers-standard~25-112

    • @levi2bear
      @levi2bear 3 роки тому +2

      Thank you so much for the prompt and courteous reply. I feel I have learned so much from you good teaching.

  • @mworke
    @mworke 3 роки тому +1

    Great video

  • @jimmyjohn7490
    @jimmyjohn7490 7 місяців тому +1

    I can't find a switch outlet as you've described in your video. I ordered from your Amazon shop and the outlet I received has two brass screws on one side and a green ground and then it has a brass and silver screw on the other side. None of the screws are next to the switch and there are no black screws

    • @kirchgoens
      @kirchgoens 9 днів тому

      Same problem here.

    • @kirchgoens
      @kirchgoens 8 днів тому

      I found the same part @fluxcondenser uses. It was at Lowe’s. Eaton part number TR274V-BX-LW “Combination Single Pole Switch and Grounding Receptacle.” It has the same black screws, etc. About $11.

  • @1marcelfilms
    @1marcelfilms 2 роки тому

    Bulbs are nice for old radios. especially with everyone getting solar the outlet voltage is almost 240v.

  • @jdoe4548
    @jdoe4548 2 місяці тому

    this is some magic

  • @JasonHunley
    @JasonHunley 2 роки тому +1

    Thank you for this! I tried making one today. It passed all the tests EXCEPT for the one where there should only be continuity when the switch is in the on position (hot prong of power cord and hot side of dual outlet). I can’t identify where I went wrong. Any ideas?

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      I’m not certain where things went wrong, but the issue, evidently, is that the switch isn’t acting as a switch (enabling and disabling current. So use this to help your diagnosis. Perhaps do a simple schematic illustrating how the circuit should function and compare that to your wiring. Good luck.

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      And also, you may want to temporarily disconnect your wiring to do simple continuity tests on your switches and outlets. Put your multimeter in “beep” continuity mode and confirm which terminals open and close continuity (no beep/beep) when you activate the switch.

    • @JasonHunley
      @JasonHunley 2 роки тому +1

      @@FluxCondenser Thank you! I went back and discovered there was a tiny sliver of metal left over from the break-away tab.

  • @jjg2753
    @jjg2753 3 роки тому +2

    how to do if it is UK plug?

    • @FluxCondenser
      @FluxCondenser  3 роки тому +1

      If the winner is from outside the US, I will rewire it. The kit has options for different voltages and the UK will not be an issue.

    • @jjg2753
      @jjg2753 3 роки тому

      @@FluxCondenser Understood. Thank you very much.

  • @billreith4343
    @billreith4343 2 роки тому +1

    If using with isolation power supply would it be best to use polarized cord without ground. Otherwise are we not defeating the isolation?

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      To be fully isolated, yes a cheater plug can be used to eliminate the ground.

  • @daperl2
    @daperl2 2 роки тому +1

    Well, I didn't break off the switched outlet tab and I connected the cable hot to the non-bridged switch screw. I passed all your tests and I passed all my tests (actually shorted one of the dual outlet sockets and the light went on) so I'm not sure why you cut the tab and made the pigtail. Still like to know.

    • @kirchgoens
      @kirchgoens 9 днів тому

      Others on UA-cam also don’t break that bridge. I’m confused.

  • @richardadelberg8961
    @richardadelberg8961 3 роки тому +1

    Not sure about wiring? I ordered directly from Amazon from your parts list . However my switched outlet doesn’t have black screws or three screws to put white wire to jump from switch to outlet ?

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Richard, sorry to hear that. Fundamentally, though, if it’s similar switch it can be wired in the same way I show. It’s just going to be a matter of locating which terminals on your switch are intended for the hot connection, and switch connections. Once that’s established, you should be able to use my guide to make the proper connections. If you’re at all unsure, though, you might want to try to locate a switch that more closely matches the one I show in the video. Good luck.

    • @richardadelberg8961
      @richardadelberg8961 3 роки тому +1

      @@FluxCondenser well it didn’t work so I guess the power coming in to side of double outlet was wrong side of socket. I got zippo out of anything no matter where switch was. Went to home depot and all they had was outlets with 2 screws on each side as well.

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      @@richardadelberg8961 OK, just use a multimeter to check for continuity while activating the switch. That should help you figure things out.

    • @richardadelberg8961
      @richardadelberg8961 3 роки тому +1

      @@FluxCondenser shouldn’t I run hot wire to switch first then instead of double outlet and then from switch outlet to double outlets?

  • @entoletao
    @entoletao Рік тому +2

    wheres the g-o-d damn schematic damn it? ..don't mind the French

  • @netlogic1ify
    @netlogic1ify 3 роки тому +1

    Saw the link to Amazon but the cable connectors there is 3/4" and the hole of the electrical box is 1". Any suggestions? Thanks!

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Check to see that the model number on your box is E9802E. That box is designed to be used with what’s called a ¾” connector, but the actual hole in the box is much larger. If your box has a ¾” marking on it, it will work with the ProConnex 44741 NM/SE Plastic Cable Connectors which are 3/4-Inch.

    • @netlogic1ify
      @netlogic1ify 3 роки тому +1

      That's what I bought from Amazon and it's the same number with 1" hole. Anyway thank you for video construction and advice.

  • @CurtTomhave
    @CurtTomhave Рік тому

    When I plug my Sperry Stop Shock tester on the bulb plug it reads open neutral, is this expected? Also, I purchased a bulb plug the has the large and small pigtails indicating polarity, is this important?

  • @heyyaheyya2810
    @heyyaheyya2810 3 роки тому +1

    I want to build this but the voltmeter takes 2 weeks to deliver. Can I build it the same way and just add the voltmeter when it comes and use it meanwhile? The other parts are available now.

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Absolutely! The voltmeter is completely optional. Useful, but optional. Just make sure you’ve got some means of double-checking the voltage coming out of your Variac/Isolation transformer. I’ve got all the parts to build this listed on my Amazon Affiliate page if you want to start there. Anything you purchase there helps out the channel. Check it out, if interested: www.amazon.com/shop/fluxcondenservintageaudioelectronics

    • @heyyaheyya2810
      @heyyaheyya2810 3 роки тому

      @@FluxCondenser TY. After reading your reply and giving some thought, apparently the the digital voltmeter outlet can be used as a standard outlet (with the same voltage as applied by the variac to the other outlet). And, AAMOF, the voltmeter could be removed after finding the actual voltage being applied by the circuit and even another receiver being tested could be plugged in? (Not sure why I would want to, but just trying to understand how the circuit is working).

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Yes, that’s correct. Both outlets on the dim bulb tester are the same and either one or two can be used. I can’t think of a use where I’d want two components plugged into it at a time, either, but if they were within the limits of the bulb and Variac, yes, that would be possible. I wouldn’t recommend it though, as if there were a short in one component it will put full current into the other. The real intention of the extra outlet is just to make it simple to add an inexpensive, yet reasonably accurate voltmeter.

  • @zoltankecse991
    @zoltankecse991 Рік тому

    Hi! Great video. Please tell me. Can I use the lamp in series after the isolation transformer (230/230) at the same time in the same circuit? Like this: Main power (230) -> isolation transformer -> series lamp -> and socket (outlet) Is this right? ( I want to test audio amplifiers.)

  • @ThePolaroid669
    @ThePolaroid669 Рік тому

    very awesome video! What model radio is that that you used? It's amazing!

  • @bigfoottoo2841
    @bigfoottoo2841 22 дні тому

    NO AMP METER? I spent my career repairing electronics and never once used a dim bulb. I always used a variac and current meter. The first thing is to have a good idea as to how much current the device being powered normally draws. As you turn up the variac, keep a close eye on the current draw. If the current draw is to high, back down the voltage. I always monitored the current and voltage. The current draw could be just a small amount beyond expected which is good information to know before you start troubleshooting. This process worked very well for me.

  • @Chris-bg8mk
    @Chris-bg8mk 7 місяців тому

    You can use the same cable grip shown here with a small amount of PVC cement to just glue it into the box, no dremel or grinding required. :)

  • @sjlBoise54
    @sjlBoise54 3 роки тому +1

    So - are the more recent "variac" transformers that look like this one and available on Amazon isolated or not? e.g., Mophorn TDGC2-2KM. Or would you need to buy and disassemble it again?

    • @FluxCondenser
      @FluxCondenser  3 роки тому +1

      If it doesn’t state that it’s an isolated unit, it’s not going to be isolated. Most Variacs are not. If you do find one that claims to be isolated, though, it’s a good idea to double check. You won’t really need to disassemble it. A simple continuity check will do the trick. Isolated Variacs are hard to come by and I believe the one I own has been discontinued.

  • @wclifton968gameplaystutorials
    @wclifton968gameplaystutorials 2 роки тому

    Here in the UK you can buy 3, 6 and 8 gang sockets and the rear housing for them meaning that you only need to use one set of wires, so one from the plug and connect it to the rear terminals of the socket which means that you don't need such complex wiring arrangements...

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      ?

    • @wclifton968gameplaystutorials
      @wclifton968gameplaystutorials 2 роки тому

      @@FluxCondenser???
      "gang sockets" means "recepticles" or "the holes the plugs go into" and the "gang" means more than one socket in the same housing since many sockets only come with 1 set of holes in Europe, UK, most switched of course since things are safer over here...???

    • @FluxCondenser
      @FluxCondenser  2 роки тому +1

      My question is not what the simplistic terms “gang” and “receptacle” mean. But rather, how your comment pertains to this project. If you’re just pointing out some differences in availability of products and codes in the US vs UK, that’s fine. However, some readers might infer from your comment that using such products would negate the need for “such complex wiring” in this project.

  • @nelsondog100
    @nelsondog100 2 роки тому

    I can’t find incandescent bulbs. Is there an alternative?

  • @richardcote9663
    @richardcote9663 3 роки тому +1

    Fun video. Thumbs up.
    I don't understand why the lower wattage bulb reduces the current more? I was expecting it to be the other way around. I expected the 150 watt bulb to draw more current and cause you to increase the variac. I'm confused. Please explain.

    • @FluxCondenser
      @FluxCondenser  3 роки тому +5

      That’s a good question, Richard. In this setup, the bulb serves two roles:
      1. Provide a low-resistance pathway of current for a device plugged into the current limiter that is operating normally.
      2. Provide a safe place for current to go when a device plugged into the current limiter is drawing too much current due to a short, etc.
      Under the first scenario (when a non-shorted device is plugged into the current limiter) the bulb never receives enough current for the bulb to draw its maximum wattage (it glows dimly). This is because the circuit to the lightbulb has the resistance of the device plugged into the current limiter reducing the current to the light bulb. It’s like wiring a light bulb normally, but introducing a resistor to the circuit.
      In the second scenario (when a shorted device is plugged into the current limiter, which is basically what the current limiter is designed to provide protection for), the bulb does receive enough current for it to draw its maximum wattage (it glows brighter). That’s because a shorted device plugged into the current limiter is basically the same as wiring a bulb normally with no resistance.
      I still haven’t explained why the lower wattage bulb reduces more current in normal operation. That’s simply because a lower wattage bulb has a thinner filament than a higher wattage bulb. The thinner the filament, the more the resistance. The thicker the filament, the less the resistance. So using a lower wattage bulb is like adding a bigger (more resistance) resistor to the circuit.
      Hope this helps.

    • @richardcote9663
      @richardcote9663 3 роки тому +1

      @@FluxCondenser Great! Got it now. Wasn't thinking of it in terms of a resistor. Makes perfect sense. Thanks. Keep the vids coming.

  • @estotts
    @estotts 2 роки тому

    Is this the same as a dim bulb tester if you dont use the variac?

  • @rul1175
    @rul1175 Рік тому

    What would happen if you unplugged the light bulb socket??? will the circuit be open??? Ex. Left(switch on and nothing connected to the outlet) Right(the radio connected in either outlet.)

    • @FluxCondenser
      @FluxCondenser  Рік тому

      Yes, if the bulb was removed or the filament blows, the circuit would become open and power would be removed from the device under test.

  • @daperl2
    @daperl2 2 роки тому

    Really enjoyed your video and the rest of my parts should be arriving today, but I have a question(s): Why do you need to cut the tab on the switched outlet and add a pigtail? Isn't it the same result if you leave the tab in place and just wire the wall cable's hot lead to the switches top screw? Thanks.

  • @jerrybonifacio9574
    @jerrybonifacio9574 2 роки тому

    hi - I have Variac Transformer TDGC2M 2000VA, can I used a 2 prong adaptor to isolate the Grounding ?

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      That will isolate the ground, but your hot and common won’t be isolated that way with a typical variac. It takes more than an adaptor to isolate a Variac.

  • @daperl2
    @daperl2 2 роки тому

    I did my short test without the volt meter since it doesn't arrive till today. Will a short fry the volt meter?

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      The short test just sees if there’s continuity. By continuity, we mean there’s a closed circuit and electricity can flow through the path under test.
      Of course nothing should be plugged into the wall. The continuity is tested using the battery in your meter. It simply sends a small voltage out of one probe and checks to see if the voltage is returned at the other probe. If so, there’s continuity and the meter will beep.

  • @peternotpeter
    @peternotpeter 2 роки тому

    I've just built this dim bulb current limiter, just one question, how would you add an ammeter to this? it would be more useful to know how many amps is going out to the DUT

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      Yes, that would be a useful addition. Simply plug the ammeter between the dim bulb and DUT.

    • @peternotpeter
      @peternotpeter 2 роки тому

      @@FluxCondenser I was thinking of a way to add banana plugs on the hot line to measure with probes but then it would leave the line open if the probes are not used or just add an ammeter gauge somehow

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      I’d consider getting one of those plug-in amp/watt meters. They’re handy to have around the house and good for work on vintage electronics. You can use it with the dim bulb and without.

  • @philliphanford2792
    @philliphanford2792 2 роки тому

    How long do you leave it on to condition capacitors in a guitar amp if: 1.) It is brand new (built it yourself) 2.) The amp has been sitting around for an unknown time.

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      I don’t recommend conditioning capacitors and a dim bulb current limiter is not the device you would use for that anyway.

  • @kunaca
    @kunaca 3 роки тому

    Do you have the link to the variac? Cant find it in your amazon link.

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      That Variac no longer seems to be available. A company called PHC enterprise once had that isolated Variac on the market and available through Amazon, but their web site and variac seem to be gone. If you want a new setup, I’d recommend getting a typical Variac (non isolated) and also purchasing a Tripp Lite isolation transformer to use with it. You could also take your chance with a used Sencore Powerite variac/isolation transformer on ebay. Those are good units, but you’ll want to verify the safe operating condition of anything you buy from ebay. Good luck!

  • @kilgoretrout4461
    @kilgoretrout4461 2 роки тому

    I’m stumped. Built nearly identical limiter, when testing continuity, everything tested perfect. But the thing is dead. I don’t get it. Is there a situation where it would test 100% correctly but be completely non-functional? The outlet is hot, the volt meter works when plugged directly to the wall…but I get absolutely nothing when I plug the limiter into the wall. Any ideas about what the hell I’m doing wrong here? Thanks.

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      If the outlet is hot, then the limiter can provide voltage to the device under test. If you mean by saying, “the thing is dead” that the bulb doesn’t light, remember, whether the bulb illuminates is dependent on how much current is passing through it. In a circumstance where you’re using a high wattage bulb and there’s little resistance at the outlet, you won’t necessarily see the bulb illuminate. And, if there’s no load at the outlet (nothing plugged in or switched on) the bulb would not illuminate at all as there’s nothing to close the circuit.

    • @kilgoretrout4461
      @kilgoretrout4461 2 роки тому

      @@FluxCondenser thanks for getting back to me. I meant that the volt meter isn’t working when plugged into limiter. It works fine when plugged straight into the wall, but I get nothing when plugged into limiter. I guess I must have wired something incorrectly, but it’s a little surprising to me that every continuity test worked perfectly…yet no outlet on the limiter is getting any juice. That make more sense? Thanks

  • @ciweld
    @ciweld 3 роки тому +1

    My question is. If there was a short in the radio, then the bulb would have quickly burned out before damaging the radio?

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      No, a short won’t blow the bulb, it’ll simply make the bulb glow to it’s maximum wattage. A light switch is nothing more than a short in the wiring. So, a short in the radio is nothing more than a light switch. That said, while a short in the radio won’t blow the bulb in a dim-bulb current limiter, the bulb will absorb a great deal of current which can potentially greatly protect the radio or other device from severe damage.
      A fuse, on the other hand, IS designed to blow in the event of a short, provided enough current runs through it that goes over its rated amperage.

  • @CraneofBoulogne
    @CraneofBoulogne 2 роки тому +1

    A schematic showing how you wired this up would be helpful. Lowes and Home Depot are thirty odd miles away for me, it is far better to order parts via mail order of one form or another. My part won't be the same as yours and therefore may not have the same terminals in the same places, as you noted in this video.

    • @FluxCondenser
      @FluxCondenser  2 роки тому +1

      It’s not a traditional schematic, but I do show a diagram of current flow which amounts to the same thing. Further, if one can’t understand the wiring of such a simple device, I’d have to wonder at not only their need for current limiter, but also their ability to be working with high voltages at all. Truly, if someone has a problem building this thing from the instructions I provide, they have no business building this thing in the first place.

    • @kirchgoens
      @kirchgoens 9 днів тому

      @@FluxCondenserThat does discourage those of us learning. We need to start somewhere.

  • @rondeldebbio9219
    @rondeldebbio9219 3 роки тому +1

    Excellent vid! Really like the the addition of the voltmeter to give true voltage to the test item, since there is a voltage drop across the bulb AND the variac output is not as accurate as the voltmeter.

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Thanks, Ron. Glad you liked the video. Yeah, I find that little voltmeter indispensable in this setup.

  • @abbywalowen7022
    @abbywalowen7022 2 роки тому +1

    Plug on amazon not the same

  • @charleswells9682
    @charleswells9682 3 роки тому +2

    Great video - I will build one. An improvement suggestion: Include a detailed parts list in the video description section especially for those parts that have nontrivial procurement aspects, such as the volt meter, box, cable connectors, bulb socket adapter, etc (yes, everything you gave part numbers for and those things that are less than common).

    • @FluxCondenser
      @FluxCondenser  3 роки тому +2

      Thanks, Charles, that’s a good suggestion. I’ll try to put a list together today and will either put it in the description or as a pinned comment.

    • @JoeJ-8282
      @JoeJ-8282 3 роки тому +1

      Also, there is a special glue-in adapter available at Lowes or Home Depot, (or most other electrical supply stores), that you can use with that PVC box that has a rubber insert in the end that has a hole in it that's the same diameter as the round power cord, along with a threaded ring that tightens down onto it so the cord doesn't pull out. It is specifically designed for cords of this round type, and it is an even neater, more professional looking way to do the cord strain relief, and it works just as well as (or even better than), the black push in cable clamp that was used here in this video, except that with the glue-in one you don't have to modify the box hole at all first, you just glue it in with some conduit or PVC glue. The black cable clamp that was used in this video is made specifically for Romex wires going into a metal enclosure such as a breaker panel box.

    • @edwinatkin5282
      @edwinatkin5282 2 роки тому

      @@JoeJ-8282 Joe , do you have a model number or picture for this part? I was unable to find it Lowes or Home Depot. Thanks

  • @mylesmcdonald8062
    @mylesmcdonald8062 2 роки тому

    Thank you for the video. I built the DBT and had all the continuity that you showed on the video. The only thing that never worked, was the LED on the switch never lit up. I hooked it up to my Variac and the DUT was an amplifier I am building. The lightbulbs did not glow (60W &^ 100 W), but there was no smoke from my amp. Just not sure if the DBT is working. Thanks
    Myles

  • @jamesdavies686
    @jamesdavies686 2 роки тому

    Nice guide but I cringed at the double ground on the outlet screw, just pigtail it with a lever nut or wire nut.

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      Absurd comment.

    • @jamesdavies686
      @jamesdavies686 2 роки тому

      @@FluxCondenser double ground wires on a single outlet screw terminal is against code in just about all 50 states. 4 more inches of spare wire (you had it) and a wire nut and it would have been legal, cleaner, and properly done.

  • @francescocosoleto
    @francescocosoleto 2 роки тому

    Very nice. What a pity this is a US version only.

  • @larrybud
    @larrybud Місяць тому

    Not a fan of this design since the switch is obfuscated by the bulb, but good otherwise.

  • @ovalwingnut
    @ovalwingnut 2 роки тому

    Is UA-cam charging you "by the minute"? Why you felt the need to rush through that explanation is baffling. However, good build.

  • @darthbubba866
    @darthbubba866 3 роки тому +1

    Great vid; but you stole my design from fortyfive years ago. All kidding aside, I'm lazy and have four bulbs already screwed into socket adapters so that I can switch the current limiting quickly. Unfortunately, filament bulbs are starting to get a little scarce.

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Ha! You don’t “screw” around!

    • @andydelle4509
      @andydelle4509 3 роки тому +1

      Judge: "You are charged with the purchase and use of an incandescent light bulb. How do you plead?" I have noticed though that my Lowe's is now stocking more incandescent bulbs. I guess they got tired of all the returns where the "60watt equivalent" has the light output of a nightlight.

    • @darthbubba866
      @darthbubba866 3 роки тому +1

      @@andydelle4509 Yeah, that "watt equivalent" nomenclature should be banned. Just give the Lumen output - works for incandescent, compact florescent, LED, and the pants-on-fire of the advertisers. The wattage draw is a separate matter, and of interest only to those who pay the electric bill. 😉

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Ha! I hear ya. I’m actually all for the transition to more efficient bulbs and with many types in my home I’ve had good luck. But, even now, I’m finding a lot of LEDs just don’t mimic incandescents as claimed. Especially in light output, color and dimming-ability.

    • @FluxCondenser
      @FluxCondenser  3 роки тому

      Absolutely right, but I think we’ll be stuck with the soon-to-be outdated watt system for quite a while. Getting Americans to change their thinking on that will be like getting them to switch to metric!

  • @LelleKidd
    @LelleKidd 2 роки тому

    This does not work in Europe. Our contacts are symmetrical, ie neutral and hot can vary.

  • @iansyme3535
    @iansyme3535 2 роки тому

    Should have used soldered lugs for all switch connections. Just is messy and perhaps not as securely fastened without them. Just my 68yr old tuppenceworth from Scotland ....

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      Nah.

    • @iansyme3535
      @iansyme3535 2 роки тому

      @@FluxCondenser Soldered lugs would look neater and give you scope to manouver the positioning to make it look awfully tidy ...

  • @SteveHacker
    @SteveHacker 9 місяців тому

    DO NOT use solder on high voltage connections like this!!! NNNOOO!!!

  • @larrydamuro2393
    @larrydamuro2393 Рік тому

    O

  • @steverahn4951
    @steverahn4951 2 роки тому

    Talking fast is disturbing and poor example of an instructional video; especially concerning electrical devices!,

    • @FluxCondenser
      @FluxCondenser  2 роки тому

      Hm. I’ve had no other complaints and many successful builds of the device. Some people need things slowed down quite a bit to process though and you may be among that camp. Consider watching at a reduced speed which UA-cam provides an option.

  • @SteveHacker
    @SteveHacker 9 місяців тому

    I will never understand why otherwise great content creators almost always feel the need to use the most obnoxious music possible, thus sending viewers running away, when NO MUSIC would be a much better option… 🤦🏻‍♂️🤦🏻‍♂️🤦🏻‍♂️