Unboxing!! A brand new GOODWE 10 kW ET storage inverter

Поділитися
Вставка

КОМЕНТАРІ • 34

  • @zorro19934
    @zorro19934 3 роки тому

    Nice video, Bugra and GoodWe Turkey! 👏

  • @kayhanince
    @kayhanince 2 роки тому

    Thanks a lot for the infos Bugra!

  • @20comer
    @20comer 3 роки тому

    Thanks, One question - what is the backup mode power limit?

  • @muhammadalijavaid4780
    @muhammadalijavaid4780 2 роки тому

    Can we install any other battery of 48V e.g. gel type or only Li-ion?

  • @estqwerty
    @estqwerty 3 роки тому

    do the inverter have option for Zero export ?

  • @adon8672
    @adon8672 4 роки тому +1

    Can you please show these inverters in parallel operation. This is the only thing making lean towards Victron inverters over Goodwe. Your stand on paralleling these ET inverters is not very clear to me.

  • @jmv4004
    @jmv4004 Рік тому

    There are two CT per line, while the manual says "Different CTs cannot connect to the same line cable".

  • @edijsegli527
    @edijsegli527 Рік тому

    How much V battery,48V or "high voltage"?

  • @hahansi
    @hahansi 2 роки тому +1

    Can the backup output be used without a battery? When the sun is shining and the photovoltaics are producing enough?

    • @haydenmahaffey1556
      @haydenmahaffey1556 Рік тому

      electricity takes the path of least resistance. u use the power u produce first and rest goes to grid

  • @SETH888
    @SETH888 4 роки тому +1

    Hope I can buy this unit in Thailand.

  • @yannis92preloude
    @yannis92preloude 2 роки тому

    Can you use this inverter with out the grid and full time off grid. and is the 10 kw peak power or continuance 10kw.

    • @GoodWeSolarAcademy
      @GoodWeSolarAcademy  2 роки тому

      This inverter currently does not support full time off-grid mode

  • @oilpress
    @oilpress 4 роки тому

    I want to see how the PW master App works with Wi-Fi. How to start Android mobile to Goodwe GW5K-ET ET inverter. From start to everything works,

  • @nikosvaidis5397
    @nikosvaidis5397 4 роки тому

    Can you connect with Batrium BMS?

  • @jackbrown5269
    @jackbrown5269 2 роки тому

    I did not understand either what is the backup power limit, if this inverter is capable of a full three phase AC output, limited just from the nominal power of the inverter (10kW in case of the 10kw model), why do I have just to choose what to back up ?
    Can't I have a FULL BACKUP mode ?

    • @GoodWeSolarAcademy
      @GoodWeSolarAcademy  2 роки тому

      Back up means if the grid outage occurs, loads on on-grid side can't be supported by any power, but loads on back up side can take power from battery or PV(if PV is available). For some countries, GOODWE is providing full load solution such as north America, Japan. Actually, for single phase inverter, we are preparing full load solution for most counties. I think if grid is not stable, it is better to choose back up solution.

    • @jackbrown5269
      @jackbrown5269 2 роки тому

      ​@@GoodWeSolarAcademy ok thanks you, I live in Italy, I was going to evaluate 3 x GW10K-ET installed in series each one with it's own BYD battery (for a PV of almost 30kW)
      I was evaluating this solution, but about what I see, and about what I read from the manual,
      1) I can't have a full backup
      2) I can't connect the 3 inverter backup line in series
      3) There are some load on the backup side that aren't allowed (heat pump for ex.)
      4) I can't work 100% off grid
      And many other thing that I read on the manual that are going to make me to desist
      I though that those inverter where designed to work even off-grid, so that the full backup feature (compatibly with the battery size of course) shouldn't be a problem for the

    • @GoodWeSolarAcademy
      @GoodWeSolarAcademy  2 роки тому

      @@jackbrown5269 For some countries, we are providing full back-up solution, such as Japan and North America(split grid). For other countries, consideirng the needs of costomers, we are only providing power to important loads if grid outage occurs, no need to support all house loads. But in the furture, we will consider to add full back-up solution for all countries. Thanks for your comment.

  • @WoaznSigi
    @WoaznSigi 2 роки тому

    Can you connect to seplos bms?

    • @GoodWeSolarAcademy
      @GoodWeSolarAcademy  2 роки тому

      We have already integrated GOODWE BMS, no need to connect others.

  • @Kido1K
    @Kido1K 3 роки тому +1

    Bring this single phase MS to South Africa please

    • @Kido1K
      @Kido1K 3 роки тому

      We need more than a 5kw hybrid inverter need

    • @GoodWeSolarAcademy
      @GoodWeSolarAcademy  3 роки тому +1

      You can contact our South Africa Office via the following website! en.goodwe.com/contact-us.asp

  • @justindividual7496
    @justindividual7496 4 роки тому

    Whatnis the price of this inverter?

  • @SARFARAZKHAN-lu1eq
    @SARFARAZKHAN-lu1eq 4 роки тому

    How many cost please reply

  • @KashifAli-gv6xm
    @KashifAli-gv6xm 2 роки тому

    How can I get?

    • @GoodWeSolarAcademy
      @GoodWeSolarAcademy  2 роки тому

      Hi Ali, you can contact our local office for the details of our products. en.goodwe.com/contact-us

  • @mahersalama3384
    @mahersalama3384 11 місяців тому

    مش بالعربي