How does PLC read data of load cell transmitter

Поділитися
Вставка
  • Опубліковано 1 гру 2024

КОМЕНТАРІ • 32

  • @ATOcom
    @ATOcom  4 роки тому +5

    In the video, the data read by the PLC is constantly changing because of interference. Solving this problem can be avoided by adding shielded wires or grounding the shell.

    • @rttr4869
      @rttr4869 3 роки тому

      Is it possible with Siemens Logo?

    • @ATOcom
      @ATOcom  3 роки тому

      @@rttr4869 yes.

    • @rttr4869
      @rttr4869 3 роки тому

      @@ATOcom ok thanks

  • @muneebkhan7266
    @muneebkhan7266 Рік тому

    Great work ❤

  • @scotthosey3450
    @scotthosey3450 Рік тому

    Ok, but if I was going to add a valve with a fast fill and slow fill how would I control all that with the scale?

  • @SandyPrawira-p3i
    @SandyPrawira-p3i Рік тому

    Is it possible to connect any type of load cell directly to the plc analog module and get the reading from the load cell?

    • @ATOcom
      @ATOcom  Рік тому

      not directly, you need a tranmitter for load cell signal to standard signal as 4-20mA, 0~5V or 0~10V.....

  • @ianwong3987
    @ianwong3987 2 роки тому

    If I selected 0-10V output by accident and need 0-5V is there a way to divide voltage in half through calibration after receiving the product?

    • @ATOcom
      @ATOcom  2 роки тому

      The output can be adjusted to 0~5V in the normal calibration manner.

  • @josefranciscovalentim2300
    @josefranciscovalentim2300 4 роки тому +2

    great !! I was waiting for this video thank you very much greetings :: valentine

  • @georgealbo
    @georgealbo 9 місяців тому

    thanks for this video can you make a series of videos for omron PLC Ladder daigram

  • @ajitsingh-wx4tm
    @ajitsingh-wx4tm 2 роки тому

    Sr i have omron cp1e plc and mad42 analog module but i am unable to select the module how to select module in cx programmer
    Please help me sr
    I am waiting for your reply

    • @ATOcom
      @ATOcom  2 роки тому

      You can get relevant information through the Omron hardware unit manual (W479).

  • @marcosantuario7777
    @marcosantuario7777 3 роки тому

    Nice video. Do you have a similar video but using a cubic liters valve?

  • @RajeshYadav-be7ds
    @RajeshYadav-be7ds 3 роки тому

    Boss Can you please make complete video on weight and plc hmi

  • @allagomar6033
    @allagomar6033 3 роки тому

    Great job thank you

  • @taufiqrahman6332
    @taufiqrahman6332 3 роки тому

    excuse me sir, can i use arduino to read weight from transmitter?, i was trying and the signal is not displaying as i expected.

    • @ATOcom
      @ATOcom  3 роки тому

      1. If your Arduino can only read digital signals, what you need is a transmitter that outputs digital signals (RS485).
      2. To read digital signals, information needs to be exchanged through a communication protocol, so direct reading is also not advisable.
      3. If your Arduino can directly read standard analog signals (0~10V, 4~20mA...), then you can display the weight data correctly.
      4. After you read the transmitter data, the display data may need to be converted (such as hexadecimal to binary or decimal).

    • @taufiqrahman6332
      @taufiqrahman6332 3 роки тому +1

      @@ATOcom thank you for your reply. i will try it

    • @oyousafali1859
      @oyousafali1859 2 роки тому

      @@taufiqrahman6332AoA
      Did you got the transmitter connected to arduino. Pls reply, i am facing the same problem.

  • @Iceoatice
    @Iceoatice 3 роки тому

    plc.fx3u-24mr can do it ?

  • @josefranciscovalentim2300
    @josefranciscovalentim2300 4 роки тому

    Good Morning you could help me with a weight indicator reading by communicating with clp omron through serial port 232 how to convert the strings into real numbers since already thankful valentine

    • @ATOcom
      @ATOcom  4 роки тому +1

      You can store the obtained data in a register area, and then use the PLC to monitor and view the data in real time. You can convert and display it to decimal in the PLC viewer. Or use some device to read the data in this storage area and display it, this device can be HMI...or other

    • @josefranciscovalentim2300
      @josefranciscovalentim2300 4 роки тому

      @@ATOcom ok thanks God bless you

  • @automationwork5904
    @automationwork5904 4 роки тому +2

    nice

  • @reginaldreed9759
    @reginaldreed9759 Рік тому

    I wish it wasn't so blurry

  • @umargul5644
    @umargul5644 2 роки тому

    Great 👍

  • @trungnguyen-es9yx
    @trungnguyen-es9yx 3 роки тому

    CovidImages need to be invested more than half19

  • @muneebkhan7266
    @muneebkhan7266 Рік тому

    Great work ❤