Post Tensioned Beam Installation Procedure at Site 🔥 | Components of PT Beam | Kavin Associates

Поділитися
Вставка
  • Опубліковано 11 тра 2023
  • #construction #home #beam #kavinassociates
    For PT works Contact:
    SF Engineering India (System) Pvt Ltd,Chennai
    9790921280
    They are doing PT Works all over India & Abroad at reasonable price.
    Ground Water Table Problem Solved ✅ | Types of Pedestal | When to go for PT Beam Designing ?
    - LINK - • Ground Water Table Pro...
    WATCH OUR LATEST VIDEOS:
    Transfer Girder with Floating Column 🔥 | Reinforcement Checking at Site | Hosur | Kavin Associates - LINK- • Transfer Girder with F...
    Nibav Vacuum Lift For Home 🔥 | Make your Home Luxury 😍 | Complete Tour and Customer feedback 😱 | KA - LINK - • Nibav Vacuum Lift For ...
    ₹2.15கால் லட்சம்னா சும்மாவா🔥| Live Testing at Site ✅ Using Original Schmidt Live Rebound Hammer - LINK - • ₹2.15கால் லட்சம்னா சும...
    WATCH OUR LATEST REPAIR SERIES VIDEOS :
    1.Column Strengthening Using Carbon Fiber Wrapping | Repair of Fully Corroded Column | Micro Concrete - LINK - • Column Strengthening U...
    2.வீட்டில் வரும் Wall Dampness-ஐ தடுக்கும் முறை 😱 | 100 % Solution | Repair Series | Kavin Associates - LINK - • வீட்டில் வரும் Wall Da...
    3.Terrace Floor-ல் வரும் Cracks, Water Leakage-ஐ எப்படித் தீர்ப்பது ? | PU Injection Method | 100% - LINK - • Terrace Floor-ல் வரும்...
    For Business Enquiry, Collaboration & Promotion - WhatsApp me - 9994087571
    Camera used for shoot - #iphone13promax
    App used for editing - #vneditor & #canva
    #youtube #youtubechannel
    If you like this video - Like, share and subscribe to my UA-cam channel... LINK - / kavinassociates
    Share this knowledge to your friends and learn new things everyday and make your skill stronger...
    Follow me - / kavinassoci. .
    Like me - / kavin1011
    FOR QUERIES & DETAILS: Mail us at - kavinprivin5@gmail.com
    #housedesign #homeconstruction #homeideas #construction #building #hometips
  • Наука та технологія

КОМЕНТАРІ • 72

  • @janasanjay1227
    @janasanjay1227 Рік тому +10

    Very Informative sir....The shape of tendon profile is given based on the BENDING MOMENT of the BEAM and Tendons are given based on calculating the losses due to the Post tensioning and also the PT increases the life span of structure while tensioning of beam rod.

  • @praveenraj519
    @praveenraj519 Рік тому +1

    Very much interested to learn and execute your ideas in construction field sir. Myself is an civil engineer. I have been watching all your videos regularly. Recently i have executed the same idea for pedestal footing by watching your vedio sir. Thank you for sharing your knowledge with us. Keep going sir😊.. We all will support you😊

  • @prasannabs3975
    @prasannabs3975 5 місяців тому +1

    Thank you sir very useful with clear instructions 👍

  • @nvdhamodaranrc8637
    @nvdhamodaranrc8637 Рік тому +1

    Very great effert educative and informative for all junior level well done sir
    I had done it

  • @arulprakash3341
    @arulprakash3341 Рік тому +1

    Very use full site video sir
    PT structure beam
    Tq so much sir

  • @navaneethakrishnan.rnavane2053
    @navaneethakrishnan.rnavane2053 2 місяці тому +1

    Ultimate தலைவா....Such a Great. Person Always

  • @muthuNeweast-wy6vw
    @muthuNeweast-wy6vw Рік тому +1

    Very useful information sir. Sir if any code book for pt slab and beam

  • @ABDULRAHIM-de2ed
    @ABDULRAHIM-de2ed Місяць тому

    Min cube strength cube for stressing is 25 mpa as per British standard

  • @mokshithkrishna604
    @mokshithkrishna604 Рік тому +1

    Speach sound very Low sir. But good message.

  • @Askar_vlogs
    @Askar_vlogs Рік тому

    GI pipe length enthana Feet varum...
    Live endla joint panni antha tendons minimum length evlo Veliya irkanum bro

  • @lragavendiran8187
    @lragavendiran8187 Місяць тому +1

    Thank you. Voice too low at the end of video not audible

  • @krantikumar268
    @krantikumar268 Рік тому +1

    Hi Kavin Sir,
    Please provide level 1,2,3 course material in book form ??

  • @mohammedismail-lx2dq
    @mohammedismail-lx2dq Рік тому +1

    super always ultimate good video and editing bro post more videos

  • @muthuNeweast-wy6vw
    @muthuNeweast-wy6vw Рік тому

    And sir Antha floating column purpose enna nu sollalaye .

  • @sivakrishnaduddu4592
    @sivakrishnaduddu4592 Рік тому +1

    You doing great job sir ❤

  • @user-no5dw9ux4p
    @user-no5dw9ux4p 4 місяці тому +1

    Nice explanation

  • @civil007manickavelt5
    @civil007manickavelt5 Рік тому +1

    Useful content 👏

  • @arulvasanthi
    @arulvasanthi Рік тому +1

    Super brother, i am also a civil engineer.

  • @prakashk7684
    @prakashk7684 Рік тому +1

    Good information 👍

  • @Prasob-pc8uu
    @Prasob-pc8uu Рік тому +1

    Job vaccancy eruka sir

  • @velladurai.sdurai8928
    @velladurai.sdurai8928 7 місяців тому

    PT slab video please

  • @user-hd1ui8om3o
    @user-hd1ui8om3o 11 місяців тому

    Inside GI pipe it is rope not rod

  • @bavash100ul
    @bavash100ul Рік тому

    I presume , tendon covering ku use pannathu GI illa flexible duct sleeve nu

  • @KumarKumar-fo5wt
    @KumarKumar-fo5wt Рік тому +1

    Super sir

  • @jamasilamani
    @jamasilamani Рік тому +1

    Brother 20mm rodla belt. 12 mm rod coloum podalama? Plz sollunga.

  • @prabhakaranganapathy34
    @prabhakaranganapathy34 3 місяці тому +1

    Sir pls give me a explanation, in some of the engineering videos saying near beam column joints beam rods should be cracked and to be inside the column ne is it right ? pls urgent

    • @KavinAssociatesOfficial
      @KavinAssociatesOfficial  3 місяці тому

      Only 12,16 mm rods can be taken outside of column…because of larger dia like 20,25 mm rods it should be cracked into column then only you can get cover for column…so only if column rods are more congestion it’s necessary to increase the column width

    • @prabhakaranganapathy34
      @prabhakaranganapathy34 3 місяці тому

      @@KavinAssociatesOfficial thank you so much

  • @user-lg4lj5xg5m
    @user-lg4lj5xg5m 6 місяців тому

    This work five year i am working Singapore job vacancy sir

  • @sivakrishnaduddu4592
    @sivakrishnaduddu4592 Рік тому

    One more doubt sir, i had heard that incase of PT Slabs the concrete should attain 80% of its grade strength at the end of 7 days in order to do PT
    Is it true sir??

  • @ramyarishi6675
    @ramyarishi6675 9 місяців тому

    Sir roof la beam podamal katti irunthal atharku ethana floor max eduka mudium sir

  • @rav8472
    @rav8472 Рік тому

    Is that possible in clay soil.... Lower level sbc clay soil

    • @geodamin8351
      @geodamin8351 Рік тому

      Soil type does not have any influence on the PT system.

  • @ruby40483
    @ruby40483 Рік тому +1

    Bro...apo PT beam oda load transfer conventional column laye pannuvangla...

  • @advancedautocaddynamicbloc7359
    @advancedautocaddynamicbloc7359 10 місяців тому +1

    New information

  • @amthanamuthan1201
    @amthanamuthan1201 Рік тому +1

    In market 12.2m lengths of rod only available how to active 42feet rod

    • @ManiGandan
      @ManiGandan Рік тому +1

      Special length can be bought by ordering specific length from the steel company

    • @geodamin8351
      @geodamin8351 Рік тому

      Bars will be lapped at appropriate locations for larger spans

  • @dubailomiteluguabbai3971
    @dubailomiteluguabbai3971 Рік тому +1

    I want to construct 60 feet long beam between 2pillars. How many steel bars should I use, and what size of requisite
    between two pillars is 60 feet span possible...?
    reply bro please
    single floor 40 feet hight slab

    • @KavinAssociatesOfficial
      @KavinAssociatesOfficial  11 місяців тому +1

      It’s possible only in PT not in conventional beam sir …

    • @dubailomiteluguabbai3971
      @dubailomiteluguabbai3971 11 місяців тому

      @@KavinAssociatesOfficial thank u bro
      what is the cost for 60×40 plan design....?
      kindly can you send what's app number

  • @naazim4297
    @naazim4297 Рік тому +1

    Mos, dos , ippo Dan puriyidu .

  • @vasuinba
    @vasuinba Рік тому +1

    I studied in my bachelor's degree minimums grade of concrete should be grater than M40 So please confirm again as per IS Code

    • @DarshanDarshan-ns6yu
      @DarshanDarshan-ns6yu Рік тому +1

      M40 grade for pre-tensioning
      but here for post-tensioned beam mini grade M30
      🙂

    • @gowthamarmstrong8981
      @gowthamarmstrong8981 Рік тому +1

      M35 is the starting grade to be used in PT works bro

  • @sanjayputtesh2269
    @sanjayputtesh2269 5 місяців тому

    1 rod length is 39 feet ,how 42feet single rod laid?

  • @ArunKumar-bz3dw
    @ArunKumar-bz3dw 5 місяців тому

    Reference is 1343

  • @kannadhasant1396
    @kannadhasant1396 Рік тому +2

    How many floor will do same way

  • @Myk_mash
    @Myk_mash 25 днів тому

    Bro is walking on a site with crocs no safety shoe lol

  • @9487645723
    @9487645723 Рік тому +5

    Thank you for your efforts in making very detailed videos. Learning a lot from your videos. 😊

  • @Profit_Momo_Pdf-File
    @Profit_Momo_Pdf-File 2 місяці тому +1

    next level stuff