Replacing A Motor With A Capacitor with An X-13, and A Variable Speed With A Motor With a Capacitor!

Поділитися
Вставка
  • Опубліковано 25 жов 2024

КОМЕНТАРІ • 61

  • @sirraident
    @sirraident Рік тому +12

    I haven't had to swap between one type of motor to another. I find relays confusing but you cleared that up. I feel confident that I could make a swap if needed now. I am getting better at reading wiring diagrams. Thank you for sharing all your knowledge with us potato techs. You are helping us all grow out of the dirt and be better, safer and fix a problem now rather than making a customer wait

    • @HVACGUY
      @HVACGUY  Рік тому +6

      Thanks for sharing! Just knowing that makes it all worth it.

    • @thenewguy3756
      @thenewguy3756 Рік тому +1

      This is the comment 🤴

    • @thenewguy3756
      @thenewguy3756 Рік тому +2

      Everyone starts from nothing. You're going places homie keep at it cheers

  • @jthonn
    @jthonn Рік тому +4

    You are a wiring genius. I have been watching you for so long now that I actually understood everything you did. Could I do it? Absolutely, but I have always been pretty good with electronics. I would not be as fast, and I would have more trouble with the mounting. Long story short, It would take me all day to do what you do in an hour or two. Like someone else said, I have always put back what was there. If I were to convert one, it would be to get rid of an x-13. I'm glad I have your channel to refer to. Thanks for all you do, if I were younger, I would have changed careers, even though I feel I did well with what I did.

  • @billkunert7281
    @billkunert7281 Рік тому +8

    That smoke alarm chirping during the last call had me checking my smoke alarms.

    • @tedperry2441
      @tedperry2441 Рік тому +3

      he hears these almost every call!

    • @MAGAMAN
      @MAGAMAN Рік тому +4

      @@tedperry2441 He does seem to work in a mostly black area.

    • @tedperry2441
      @tedperry2441 Рік тому +1

      well poverty gets hot too... Also when I started we worked a lot of realty companies and they did not give a shit what they sent you to . And wanted a cheap fix . Then holding your pay 60 days.

    • @MrKen59
      @MrKen59 Рік тому

      I often wonder if some people simply don’t hear the chirp? I’ve had neighbors who have a smoke detector chirping and never do anything about it.

    • @thenewguy3756
      @thenewguy3756 Рік тому

      😅

  • @jimmylanders2175
    @jimmylanders2175 Рік тому +3

    This was a great vid Curtis! Thank you so much for the time you put into your vids and giving back to this trade. I have learned so much from your training vids.

  • @stephenbullock-yn3vh
    @stephenbullock-yn3vh Рік тому +3

    Great work on both 👍

  • @robalexander7348
    @robalexander7348 Рік тому +2

    Well done Curtis , 2 good repairs. You could also ask if the customer if they would like there smoke alarm batter replaced whils't there 😉 Au

  • @soloch69
    @soloch69 Рік тому +1

    Great video like always 🙏🏻

  • @stevencossaboon3237
    @stevencossaboon3237 Рік тому +2

    Nice jobs Curtis.

  • @corruptedbrain6
    @corruptedbrain6 Рік тому +2

    i love the rainy days

  • @MsFishingdog
    @MsFishingdog Рік тому +2

    Great video

  • @chuckquinn8026
    @chuckquinn8026 Рік тому +2

    The old bag-o-wires! 👍👍

    • @HVACGUY
      @HVACGUY  Рік тому +3

      It’s a must have

  • @MikeB9771
    @MikeB9771 Рік тому +1

    Well done Curtis, thorough way of showing how to do both.
    Only one issue with a lot of your videos, why is it always dark in the hallways? Do they not have lights there?

  • @johnwalker890
    @johnwalker890 Рік тому +3

    Good job Curtis, You should rebuild some of your old air handlers from new installs instead of scrapping them and use them for under privilege individuals that can't afford new systems.

    • @MAGAMAN
      @MAGAMAN Рік тому +6

      The "under privileged" should go get a job and stop living off of my tax dollars.

    • @johnwalker890
      @johnwalker890 Рік тому +1

      Okay, you got it, your right.

    • @Jamie-po9zk
      @Jamie-po9zk Рік тому +2

      He seems to be working in really dingy looking places alot. I think he's doing his part to help the needy already

    • @johnwalker890
      @johnwalker890 Рік тому +1

      True, just an opinion to keep steady work going.

  • @kg4muc
    @kg4muc Рік тому +1

    Good move by putting that one back to as close OE as you could and given it was originally ecm equipped it wasn’t that bad to convert

  • @MrKen59
    @MrKen59 Рік тому +2

    Question - if the motor is fine but has a slight unbalance, can you talk about how to smooth things out?

  • @Garth2011
    @Garth2011 Рік тому +2

    Kind of hard to justify the $400 price difference in a PSC vs Evergreen. The only benefits gained would be the variable speeds and less noise but surely no gains in saving on power for the life of them.

  • @mikez1968
    @mikez1968 Рік тому +3

    That cop is literally a "Pig". Lol

  • @rgmatta3524
    @rgmatta3524 Рік тому +2

    The 6 amp rating maybe for 120 volt operation, since it's about double the current draw at 240 volts.

    • @HVACGUY
      @HVACGUY  Рік тому +1

      It was suggested to me that the rating was so high because it had originally been a variable speed motor

  • @jaycrypto-ns7vs
    @jaycrypto-ns7vs Рік тому

    I've seen guys try to plug and play those with carrier and not see there's a wire swap. Frys all the low voltage. Only with the evergreen universal.

  • @SETX_Sirens_and_Rail_02
    @SETX_Sirens_and_Rail_02 Рік тому +1

    Sounds like either the motor is improperly sized or the static pressure is absolutely terrible

  • @whizzo55
    @whizzo55 Рік тому +2

    You da man!

  • @clivejoyce9437
    @clivejoyce9437 Рік тому +2

    It rains every day in Wales 😕

    • @HVACGUY
      @HVACGUY  Рік тому +4

      No way I could live in a place like that.

  • @jimmyni8136
    @jimmyni8136 Рік тому +2

    For the one that you wired the psc motor to that relay does that mean there won’t be a delay when blower is in the off cycle? So the blower is going to stop immediately when the condenser stop?

    • @HVACGUY
      @HVACGUY  Рік тому +2

      Yes, unless a time delay is programmed into thermostat.

    • @jimmyni8136
      @jimmyni8136 Рік тому

      @@HVACGUY o gotcha thanks. Would that cause issues long term because the evap coil would still be cold?

  • @smacleod69
    @smacleod69 Рік тому +2

    i did an Everygreen motor with all the wires. about drove me up a wall

  • @ryankizzire2321
    @ryankizzire2321 Рік тому +2

    Are the rescue motors any better an or cheaper

    • @AllTattedUp13
      @AllTattedUp13 Рік тому +2

      Same thing as oem motor pretty much and alot cheaper.

  • @davefuelling7955
    @davefuelling7955 Рік тому +1

    I would have gotten up and ripped that smoke detector off the wall and thrown it outside.

  • @jasonostrowski3972
    @jasonostrowski3972 Рік тому +2

    Please change the transformer

  • @Perdomo1831
    @Perdomo1831 Рік тому +1

    Why would you swap a ecm for psc, Or viceversa ?

    • @HVACGUY
      @HVACGUY  Рік тому

      Cost and dependability

  • @karellodewijks4971
    @karellodewijks4971 Рік тому +2

    😊😊👍👍

  • @benaskew1301
    @benaskew1301 Рік тому

    That's odd you chose to do high speed for cooling and medium for heat on that evergreen. Should be the other way around.

  • @KERTER21
    @KERTER21 2 місяці тому

    I guess that’s the end of that

  • @m9ovich785
    @m9ovich785 Рік тому

    Careful with the Music Curtis.
    One of these times You are gonna get flagged...
    Thanks..

  • @redneckways1617
    @redneckways1617 Рік тому +1

    Only thing bad about the green speed motors is that if two speeds are energized at the same time the motor will reverse direction

  • @ThomasWalker-m2y
    @ThomasWalker-m2y Рік тому

    You sure work in some nasty spaces

  • @kens.3729
    @kens.3729 Рік тому +2

    HVAC has as Many Acronyms as many Other Industries. We Love our Acronyms. 🤔😬👎

  • @paulhickey4485
    @paulhickey4485 Рік тому +2

    Why would you replace a psc with an x13? I'd rather have a psc any day.

    • @HVACGUY
      @HVACGUY  Рік тому +2

      Amp rating

    • @paulhickey4485
      @paulhickey4485 Рік тому

      @HVACGUY is true, but the cost of the x13 negates the savings.