    some clarification done
    when the temperature is on lowerr side and rising the interface moves inside but if the temperatures start going above 100 we loose sealing water n it starts overflowing through water side

КОМЕНТАРІ • 33

  • @ashokashok-xm3fg
    @ashokashok-xm3fg 5 років тому +1

    Make important difficult oral questions with answers that become very helpful for us

  • @prabhatpandey5353
    @prabhatpandey5353 3 роки тому +1

    Bhut badiya sir

  • @maylaymaylay8970
    @maylaymaylay8970 4 роки тому +1

    thank you

  • @akarshanilkumar3461
    @akarshanilkumar3461 11 місяців тому

    💯

  • @md.mahmudulhasan1304
    @md.mahmudulhasan1304 3 роки тому

    what would be the solution if need to purify bad fuel (higher impurity) and gravity disc did big?
    what is the main reason for motor Amp high and low?
    what is the reason of higher rpm of vertical shaft?
    thanks in advance

  • @ashokashok-xm3fg
    @ashokashok-xm3fg 5 років тому

    Why the purifier shape is triangle in sludge deposit side why not square ?

  • @sanatanibengal9210
    @sanatanibengal9210 Рік тому

    How to distinguish between overflow side and bowl side,please explain sir

  • @ilhamalfaridzi4629
    @ilhamalfaridzi4629 11 днів тому

    Sir if purifier cannot desluging what is cause ?

  • @shubhamsarin9630
    @shubhamsarin9630 4 роки тому +3

    Wont the interface shift inside when the temp goes up ?

    • @BasicMarineEngineering
      @BasicMarineEngineering  4 роки тому

      Yes it shifts the interface

    • @jdebdyutimandal
      @jdebdyutimandal 3 роки тому +2

      Interface shifts inside if temp high... Not outside

    • @BasicMarineEngineering
      @BasicMarineEngineering  3 роки тому

      Correct when the temperature is on lowerr side but it the temperatures start going above 100 we loose sealing water n it starts overflowing through water side

    • @BasicMarineEngineering
      @BasicMarineEngineering  3 роки тому

      Correct when the temperature is on lowerr side but it the temperatures start going above 100 we loose sealing water n it starts overflowing through water side

  • @fairuzali18
    @fairuzali18 5 років тому +1

    hi,i have some problem with alfa laval mopx 205 purifier..the bowl keep auto flush when sealing water enter..using epc-41 parameter..but with manual manner seems to be ok can seal the bowl..whats the problem?

    • @BasicMarineEngineering
      @BasicMarineEngineering  5 років тому

      Auto flush? Is it overflowing ?
      But if in manual runs properly then some electrical problem, iam assuming all parameters are fine when running in manual. Just let me know what u meant by auto flush

    • @fairuzali18
      @fairuzali18 5 років тому

      when closing water in and sealing water in automatically discharged the bowl through sludge drain

    • @fairuzali18
      @fairuzali18 5 років тому

      parameter sequence is like this closing water in 15scd then sealing in 45scd then oil in while this sequences run the closing water wont stop...till oil in...with this parameter run the bowl keep discharge cant seal

    • @BasicMarineEngineering
      @BasicMarineEngineering  5 років тому

      Oil is coming or water? If water is coming out then your sealing water is leaking if closing water is leaking then bowl will seal but sludge tank level will increase but if desludging water is leaking then bowl will not seal find out which water is leaking
      Check the manual for different reasons for the same problem it vl help

    • @fairuzali18
      @fairuzali18 5 років тому

      i think u misunderstood what im trying to explain

  • @amandas7893
    @amandas7893 4 роки тому +2

    While starting purifier amp increases but not coming down reason sir

    • @BasicMarineEngineering
      @BasicMarineEngineering  4 роки тому

      Overhaul purifier n check every part something is definitely wrong, check the bearings spring check the distance as given in the mannual

  • @jdebdyutimandal
    @jdebdyutimandal 3 роки тому +2

    Rising temp will take the interface inside.. Not outward

    • @BasicMarineEngineering
      @BasicMarineEngineering  3 роки тому

      Correct that is when its lower temperature but when the temperatures start going above 100 u would lose water n the interface moves out

  • @CADETSUNDEEP
    @CADETSUNDEEP 5 років тому +1

    Sir do you have fb I’d or can you say your
    e-mail ....

    • @BasicMarineEngineering
      @BasicMarineEngineering  5 років тому

      Check my page n you can message there
      facebook.com/BasicMarineEngineering/

  • @arbaazahmad6509
    @arbaazahmad6509 5 років тому

    Use some kind of microphone..ur voice is nt much audible