Bosch Rexroth 4WRLE Valve Configuration Tutorial | How to set up internal piloting and draining

Поділитися
Вставка
  • Опубліковано 22 лип 2024
  • Did you know that configuring Bosch Rexroth's 4WRLE-4X Hydraulic Proportional Valve can be as easy as removing a few plugs? Learn how to change the pilot configuration for internal piloting and draining in this configuration tutorial. This configuration tutorial was demonstrated with a size 16 4WRLE-4X hydraulic valve, but it's just as easy for other sizes too. Visit our blog post and download the datasheet below (refer to page 7) for more information on other sizes.
    Blog post: blog.airlinehyd.com/rexroth-4w...
    Shopping link: www.airlinehyd.com/categories...
    Contact for help: www.airlinehyd.com/pages/cont...
    Learn more in our other video: Bosch Rexroth 4WRLE Valve, Comparing Old vs. New Model | Tech Talks
    • Bosch Rexroth 4WRLE Va...
    Don't forget to SUBSCRIBE to our channel! ua-cam.com/users/airlinehydrau...
    AND follow us on social media!
    Facebook - / airlinehyd
    Twitter - / airlinehyd
    LinkedIn - / airline-hydraulics-cor...
    ABOUT US:
    Airline Hydraulics Corp. is a leading provider of innovative technical solutions for our customers across all industries. We offer components, engineered systems, and services in the technology areas of fluid power, automation & control, structural systems, and machine safeguarding. As an ISO 9001:2015 certified company, we're committed to supplying quality parts, services, and equipment repairs to optimize our customers' productivity and safety. Learn more about Airline at www.airlinehyd.com/
  • Наука та технологія

КОМЕНТАРІ • 6

  • @AirlineHydraulics
    @AirlineHydraulics  2 роки тому

    If you have any questions or need help with your application, reach out to our helpful engineers and technicians here - bit.ly/3H7BK8s

  • @rjzhang892
    @rjzhang892 6 днів тому

  • @ktmturbo5836
    @ktmturbo5836 7 місяців тому

    Nice video, is it common that the little pilot on top off valve fails?

    • @AirlineHydraulics
      @AirlineHydraulics  7 місяців тому

      Great question! Yes, it is common since the electronics are housed there and the valve operates around 200Hz. It can be replaced, but for best performance, it should be mated with the main stage and tuned to factory specifications.

  • @Srk7028
    @Srk7028 Рік тому

    For external pilot configuration, how the pilot supply is given if plugs are not removed on this model?

    • @robertpanzarella8328
      @robertpanzarella8328 Рік тому +2

      The Hydraulic Pilot Pressure has to be supplied into the X port if the external pilot plug is installed. When the plug is removed the X Port is connected to the Supply Pressure.