Making Practical Electrical Calculations

Поділитися
Вставка

КОМЕНТАРІ • 138

  • @willjac1tv73
    @willjac1tv73  2 роки тому

    If you have watch the video, we will appreciate your comments. Thank you.

  • @pinoyelectrical
    @pinoyelectrical 4 роки тому +2

    Best lecture and information sir. Salamat po sa pamahagi ng knowledge and experience.

  • @willjac1tv73
    @willjac1tv73  4 роки тому

    Yes, we can issue webinar certificates.
    The fee is Php300 per certificate,
    Pls remit via our GCash, 0998 311 6838 or thru our bank account.
    A scanned copy of the cert can be sent via email.
    Shipping/delivery fee is Php150, if you wish it delivered to your address in the Phils.
    If acceptable, please send your complete name and your address.
    Thank you and regards.
    Engr. Juan
    0943 0616 215,
    0998 311 6838

    • @bemsky228
      @bemsky228 2 роки тому +1

      Hi Sir, nag iisue parin po kayo ng webminar certificate for this presentation?

    • @willjac1tv73
      @willjac1tv73  2 роки тому

      @@bemsky228 yes

    • @manuellastrollo2168
      @manuellastrollo2168 2 місяці тому +1

      Sir hanggang ngayon po ba nag i-issue pa kayo ng Certificate para dito webinar na to Sir?

    • @willjac1tv73
      @willjac1tv73  2 місяці тому

      @@manuellastrollo2168
      Yes, as long as you have watched the video fully. You may send your request via email
      wiljjuan.engr@gmail.com

    • @manuellastrollo2168
      @manuellastrollo2168 2 місяці тому

      yes Sir@@willjac1tv73 natapos ko naman po Sir yung whole 3 hours & more ng webinar. may email po pala ko Sir regarding dun sa pdf Sir

  • @ichiro5449
    @ichiro5449 4 роки тому +2

    Salamat po sa mga video nyo sir, sana marami pa kayong maturuan lalo na ngayong pandemic more power po

  • @ramelcarual8633
    @ramelcarual8633 3 роки тому +1

    Thank you so much Sir.Napakalaking tulong po ito sa pagawa ko ng design.

  • @edwinastronomia1032
    @edwinastronomia1032 3 роки тому +2

    Thanking you sir for sharing. This is so much appreciated.

  • @artswithhannah
    @artswithhannah Рік тому

    Sir Ganda Ng presentation mo.nka isip tuloy aq mg take Ng rme exam.problema. Q un mg pirma s c.expirience q.tesda lng KC un certificate q.tnx

  • @orlandodelossantos6005
    @orlandodelossantos6005 3 роки тому +1

    Salamat sa libreng kaalaman sir william

  • @roanneamponin7482
    @roanneamponin7482 4 роки тому +2

    Thank you for sharing this kind of topic. Pwede pong balik balikan.

  • @willjac1tv73
    @willjac1tv73  3 роки тому +4

    Hello! Please share these videos to others. Thank you.

  • @jeromehimaya9836
    @jeromehimaya9836 4 роки тому +1

    Good day Sir.
    Very informative presentation. Thank you so much for sharing..

  • @jbart2109
    @jbart2109 Рік тому

    Thank you for sharing your expertise sir, this is very informative. Godbless po more webinars to come.

  • @allansunga975
    @allansunga975 4 роки тому +1

    Very informative! Salamat po Engr:William.

  • @janessakeishasediego9047
    @janessakeishasediego9047 3 роки тому

    Thank you for sharing! 🥰

  • @domingosallaoiii236
    @domingosallaoiii236 4 роки тому +1

    thank you sir for sharing your knowledge and expertise in electrical profession..

  • @andraituazon617
    @andraituazon617 4 роки тому +1

    Very Informative,Thank you for sharing your knowledged to us, specially for those rookie engineers like me.

  • @raymarkventura5604
    @raymarkventura5604 3 роки тому +2

    Very informative sir! Good job!!! 👏👏👏👏🙌😊

  • @rubyvillagracia6381
    @rubyvillagracia6381 3 роки тому

    Thank you so much sir.
    Very impormative and helpful.
    GOD BLESS. Abangan ko mga sunod ninyo lecture sir.

    • @jessedawson9654
      @jessedawson9654 3 роки тому

      Sorry to be so offtopic but does anyone know of a method to get back into an instagram account??
      I somehow forgot the account password. I appreciate any tips you can give me!

    • @matiasfisher676
      @matiasfisher676 3 роки тому

      @Jesse Dawson Instablaster :)

    • @jessedawson9654
      @jessedawson9654 3 роки тому

      @Matias Fisher thanks for your reply. I found the site thru google and im in the hacking process atm.
      Takes quite some time so I will reply here later with my results.

    • @jessedawson9654
      @jessedawson9654 3 роки тому

      @Matias Fisher It did the trick and I finally got access to my account again. I am so happy:D
      Thanks so much you saved my account!

    • @matiasfisher676
      @matiasfisher676 3 роки тому

      @Jesse Dawson you are welcome :D

  • @one_man_army...
    @one_man_army... 4 місяці тому +1

    Very helpful video

    • @willjac1tv73
      @willjac1tv73  4 місяці тому

      Kindly share to others. Thanks

  • @18pher
    @18pher 4 роки тому +1

    salamat ng marami Sir.

  • @eligran3726
    @eligran3726 3 роки тому +1

    Good eve po Sir Will watching from Makati City..

  • @mheltagalag8715
    @mheltagalag8715 4 роки тому +1

    Ganda sir na topic ok Sana Kung my certificate. God bless po

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      please send your request to wiljjuan.engr@gmail.com

  • @andraituazon617
    @andraituazon617 4 роки тому +2

    I have a question po sir with respect " In sizing branch ckt. rating and OCPD of a single/three phase motors like ACU, your computation was by multiplying HP rating to 746 W divided by 0.8 pf and 0.9 eff. while in 10.1.2 LOAD SCHEDULES & DESIGN COMPUTATIONS 1 PHASE" You said that we refer to PEC for full load rating of motor, I've assume it is Table 4.30.14.2 (Full-load Amps of Single Phase Motors) because in your load schedule " 1HP ACU full load rating is 8 Amp which is indicated in Table 4.30.14.2, but if we use I = 1HP x 746W / 230V x 0.8 x 0.9 eff = 4.5 A only. What should we use ?

    • @willjac1tv73
      @willjac1tv73  4 роки тому +2

      The use of 8A as full load current is more of a safe assumption in the design analysis for sizing the service entrance since there is only one AC unit in the sample calcs.

  • @jesstaynervalero4676
    @jesstaynervalero4676 4 роки тому +1

    Good job Sir. Thanks for this

  • @jamesduvincarreon9839
    @jamesduvincarreon9839 3 роки тому

    Sir Wil, Good evening I'm a big fan of yours po.Thankyou SA knowledge po lalo sakin .Fresh graduate po.Ask Lang po sir Wil Yung nakalagay ba s PEC na general lighting and receptacle load.na ( Area of house x VA as per PEC) ex. (100x24=2400va) Yung bang 2400 va is the total load for lighting and convenience load? Or isa2x sila 2400 for ilaw at 2400 din SA convenience load?
    Thank u po sir Wil SA answer Godbless po.and more videos to upload for a newbi like me😀

  • @redgefleming1535
    @redgefleming1535 2 роки тому +1

    Pwedi po mag ask nang certificate? :)

  • @rommelabejero384
    @rommelabejero384 4 роки тому +1

    sir wil kelan po ginagamit ang FLC ng alternating-current motors sa table 430.250 ng NEC 2017?

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      The FLC indicated on nameplates is the most accurate value. However, if this is not available, then values of FLCs indicated in code can be used anytime, when you have the code by your side. But if you are in the field and these data are not readily available, then a value computed using the indicated formulas can be used.

  • @davidloren9238
    @davidloren9238 4 роки тому +1

    Hi Sir,
    sana may video din po kayo ng Single family dwelling unit design and calculation pati pp yung multi family with different size of Floor area for para gawin ko pong basis sa pag gawa po ng design in the future.
    Thanks po God bless you po sir.

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      Pls watch my video "How to Draft Electrical Plans/Documents"

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      ua-cam.com/video/1vGzzGSgmBg/v-deo.html

    • @davidloren9238
      @davidloren9238 4 роки тому +1

      @@willjac1tv73 Maraming salamat po sir, sana madami pa kayo magawa na mga videos and webinars. Malaki po tulong ninyo sa mga LEP na gaya ko. God bless po

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      God willing, we will discuss more critical issues and details that may arise for the benefit of everyone. Let us pray for everyone.

  • @emmanuela.delacruz1866
    @emmanuela.delacruz1866 2 роки тому

    Sir Jac, can I have your copies of this video? Yung word or pdf Files po.

  • @benjaminandesiii7654
    @benjaminandesiii7654 4 роки тому +1

    Good day po Sir Wil! Ask kolang po if pwede po kaya makagawa ng free Webinar Workshop Topic in How to Design and Plan a Residential? Thank you so much for your Webinars Sir! More power!

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      Please watch this..
      ua-cam.com/video/1vGzzGSgmBg/v-deo.html&feature=share

  • @18pher
    @18pher 4 роки тому +1

    Thank you po Sir,

  • @benjohnramos3050
    @benjohnramos3050 3 роки тому +1

    👏👏👏👏👏

  • @kaezhia_prrty363
    @kaezhia_prrty363 4 роки тому +1

    hellow sir Good day po..myron ka po bang space planning or plant room planning for electrical...(EE room,genset room,TR room tapos yung pagsizing nga elevator shaft and riser shaft..thanks po..Godbless...

    • @willjac1tv73
      @willjac1tv73  4 роки тому +1

      cge, give me time to prepare the ppt..

    • @kaezhia_prrty363
      @kaezhia_prrty363 4 роки тому +1

      @@willjac1tv73 thankyou sir..kakatapos ko lang ngayon ng Practical Design Analysis, Voltage Drop & Short Circuit Calculations tapos narecieve ko na rin yung email mo kanina about PDF tapos manonood sa live mo for basics of project management..maraming maraming salamt sobrang malaking tulong po..Godbless po..

    • @ranielmana7892
      @ranielmana7892 3 роки тому

      Hi sir jeth. Can you share po practical design analysis, voltage drop and short circuit analysis soft copy? Thank you so much po. ranielmana0330@gmail.com yan po email ko

  • @bloomberg4865
    @bloomberg4865 4 роки тому +1

    Sir question lang po ,, bakit ung sizing ng aircon wire nka based po hp computation hindi aa pec code na full load amps based on hp rating? Salamat po

  • @bloomberg4865
    @bloomberg4865 4 роки тому +1

    Pti po ung firepump db po nka based ung computation ng cb non sa lockedrotor current ?

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      Ganyan pag wala ka value ng lock rotor current..

    • @bloomberg4865
      @bloomberg4865 4 роки тому

      @@willjac1tv73 ok sir salamat po .

  • @bloomberg4865
    @bloomberg4865 3 роки тому +1

    Sir bakit po sa mga ocpd ng pumps nyo wala na ung 2.5 (inversetime cb) na factor para makuha ang ocpd ?

    • @willjac1tv73
      @willjac1tv73  3 роки тому

      Max allowable trip setting lang ang 250%. It ïs only to prevent early tripping during starting especially the large diameter motors with across the line starters..

    • @bloomberg4865
      @bloomberg4865 3 роки тому

      @@willjac1tv73 ah sir bale pdetayo mag size based sa computed wire ampacity.?

    • @willjac1tv73
      @willjac1tv73  3 роки тому

      @@bloomberg4865 yes

    • @bloomberg4865
      @bloomberg4865 3 роки тому

      @@willjac1tv73 ok sir thankyou po

  • @bloomberg4865
    @bloomberg4865 3 роки тому +1

    Sir kpg po ba nka set ung feeder wires ,example po pag nka 4 sets paano po ung eqmnt grounding nun ? 4 din po ba o isa lang na nka base sa ocpd rating? Salamat po

    • @willjac1tv73
      @willjac1tv73  3 роки тому

      One ground wire per circuit or feeder is enough.

    • @bloomberg4865
      @bloomberg4865 3 роки тому +1

      @@willjac1tv73 ah ibg nyo po ba sabihin kaht na nka 4 sets po ako na wires ung grounding q 1 lang ? N nka based sa ocpd rating? Tama po ba .

    • @willjac1tv73
      @willjac1tv73  3 роки тому

      @@bloomberg4865 normally, wala naman current flowing sa ground except kung mai ground fault

  • @clientbeduya7287
    @clientbeduya7287 3 роки тому

    Thank you sir..

  • @opecons
    @opecons Рік тому

    Engr bakit sa NEC ang single outlet, duplex outlet at triplex outlet ay 180VA? Di ba sa NEC tayo nagbasi?

    • @willjac1tv73
      @willjac1tv73  Рік тому

      It is not safe to assume 180va load only for the 3 holes.

    • @willjac1tv73
      @willjac1tv73  Рік тому

      I dis agree with the writers/ authors of the NEC and the PEC on this

    • @opecons
      @opecons Рік тому

      @willjac1tv73 so sir mali pala yung interpretation nila sa 180v?

    • @willjac1tv73
      @willjac1tv73  Рік тому

      I always try to do my design on the safer side.
      You see, If you have 1 outlet and the appliance connected is 180va, then they are right. But if you have 2 outlets (duplex), if you already have a 180va appliance plugged in and there is still another hole, chances are the 180va load will be breached when another appliance is plugged in. And this is more so if there are holes (triplex).

    • @opecons
      @opecons Рік тому

      Sir ano po ba yung 180VA? Kasi kun may appliance iplug sa outlet sumubra naman sa 180VA?

  • @isaganialarcio5659
    @isaganialarcio5659 4 роки тому +1

    good evening sir Will,

  • @arkitekdlf3682
    @arkitekdlf3682 4 роки тому +1

    thanks

  • @johnpaulcastillo2940
    @johnpaulcastillo2940 4 роки тому +1

    Sir may motor b n 3 phase na 230 V? Pag nakadelta

    • @willjac1tv73
      @willjac1tv73  4 роки тому +2

      Yes. Ang mga motors ay 12 terminals, para pwede ikonek SA ibat ibang voltages at pwede delta or Wye connected. If 220v naka delta connected, if 380v naka Wye connected.

    • @johnpaulcastillo2940
      @johnpaulcastillo2940 4 роки тому

      Nakadepende b s supply kung wye or delta ang gagamitin mo sir?

    • @johnpaulcastillo2940
      @johnpaulcastillo2940 4 роки тому

      Thanks for the answer po sir😊

  • @18pher
    @18pher 4 роки тому +1

    Porferio Vineles, Hi Sir, puedi po bang makahingi ng presentation mo. Salamat po.

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      Please email your request to wiljjuan.engr@gmail.com

  • @niclaxamana4806
    @niclaxamana4806 4 роки тому +1

    watching now sir

  • @peodinagatislands3759
    @peodinagatislands3759 4 роки тому +1

    gud evning sir....

  • @joytaltura5675
    @joytaltura5675 4 роки тому

    Sir ok lang ba magwiring ng bahay na walang ground?

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      Dapat laging Mai ground connection. It is unsafe kung wala.

  • @opecons
    @opecons 3 роки тому

    Tanong lang po sir , ano po ang standard wire color code ng hot wire para sa single phase at three phase?

    • @redgefleming1535
      @redgefleming1535 2 роки тому

      Red and black usually the single phase, red, yellow, blue, grey/white for 3 phase 4 wires

    • @opecons
      @opecons Рік тому

      ​@@redgefleming1535official ba na wire color code sa atin sa pinas

  • @18pher
    @18pher 4 роки тому +1

    Hi Sir, May i request for a 400 volt system for high rise, Salamat po.

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      Okay

    • @jy1275
      @jy1275 4 роки тому +1

      Sir good day po...pwede ba makahingi ng slides nito kng pwede lng...salamat po...eto po gmail ko
      jimmyysuon1984@gmail.com

    • @willjac1tv73
      @willjac1tv73  4 роки тому +1

      @@jy1275 please email your request to wiljjuan.engr@gmail.com

  • @darrenroydelaminez1008
    @darrenroydelaminez1008 4 роки тому +1

    Pahingi din po ng copy nito.sir

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      Please email your request to wiljjuan.engr@gmail.com

  • @bloomberg4865
    @bloomberg4865 4 роки тому +1

    Sir paano po makuha ung AF

    • @willjac1tv73
      @willjac1tv73  4 роки тому +1

      ..ang AF ay ampere-frame, meaning yung laki or tibay ng pagkagawa ng isang breaker. Ito ang mga standard na frame size ng mga breakers: 60AF, 100AF, 225AF, 400AF, 600AF, 800AF, 1000AF, 1200AF, 1600AF, 2000AF, 2500AF, 3200AF, 3600AF, 4000AF at 6000AF. Generally, habang tumataas ang AF ng isang CB, mas mataas ang kanyang kiloampere interrupting capacity o KAIC, to open a circuit during a short circuit. Ibig sabihin, pwedeng 100AF 70AT 3P ang isang breaker, pwede din 225AF 70AT 3P, mas mataas ang KAIC rating nung 225AF kesa 100AF. Pwede din 600AF 500AT 3P pero pwede ding 1200AF 500AT 3P ang isang breaker. Pag nakompute mu ang level ng SC current sa isang bus ay napaka taas, pipili ka ng breaker na tutugma o mas mataas ang KAIC nito sa nakompute mu na SC current.

    • @bloomberg4865
      @bloomberg4865 4 роки тому

      @@willjac1tv73 ok sir gets q na po.😀😀😀 Maraming salamat po . Godbless sir will.

  • @wilsonpingkay8493
    @wilsonpingkay8493 4 роки тому +1

    HI sir anu pong email niyo bali hinge po sana ako copy ng PDF ng presentation niyo po. thank you po

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      please send your request to wiljjuan.engr@gmail.com

  • @pinoyelectrical
    @pinoyelectrical 4 роки тому +1

    Pahingi din po bang pdf sir.

    • @willjac1tv73
      @willjac1tv73  4 роки тому

      Please email your request to wiljjuan.engr@gmail.com