SNADI INVERTER (Battery Parameter Settings)
Вставка
- Опубліковано 15 вер 2024
- Snadi Battery Parameter Settings:
Press and Hold Up and Down Button, then press and Hold On Button altogether.
B01 Charging Voltage 13.8V +/- 1.5V
B02 - Recovery Voltage - 13.5V +/- 1.5V
B03- Low Voltage Alarm - 10.5V +/- 1.5V
(Transfer to Grid)
B04- Cut Off Voltage - 10V +/- 1.5V
(Inverter Shutdown)
B05 - Battery Icon Indicates 0% - 10V +/- 1.5V
B06 - Battery Icon Indicates 100% - 12V +/- 1.5V
Make Sure to put AC input for these setup.
For order please clink the link
/ leapelectricph
Very short however informative and direct to d point. sir. Keep it up sir.
Thank you for sharing sir new supporters here
Maraming salamat po sir magagamit ko sa aking SNADI for UPS pag naka ongrid na ako
diretso explain..ayus..thank you
Good morning po pwede mag request?
Pa demo din po ng
snat 3kw 12v
Salamat po.
Informative po ang video nyo. Tanong ko lng po ano po ang pinakamataas na low voltage disconnect at voltage reconect
nsa description po
very informative thnx for sharing
Sir question lang po i have the same Inverter pag nilagyan kuba po Supply from Grid ang AC input ng inerter Malakas po bah consumption nya habang nag charge sya ng Battery while may mga Load ang inverter?
And What if po na charge na sya ng solar automatic po bah na lilipat sya sa battery? And pagsapit ng gabi once na reach nya ung 11.5v saka lang sya ulit lilipat sa grid?
The main concern ko po is kung malakas ba consumi nya kung kakabit kupa sa Grid.
SALAMAT PO SANA MAPANSIN.
Ang linis po ng explanation mo sir. Pano po sir pag may solar panel na para pag umaga sa solar panel siya magccharge need pa ba ng solar charge controller nun? Thank you po and godbless
need controller pa po
hi, I bought an 8kw 48vdc Snadi inverter. but it doesn't allow me to set the batteries as you can see in the video, why?
Bkit ang bilis nalobat Ng battery Yung xkin
24v 400ah isang ref lng at ilaw 24/7 gamit. Lead acid battery paanu eh subra subra nlng halos ang harvest
Boss..anu po kayang problema ng snt inverter ku pah naka charge mode 8.7v lng out nya sa dc
Pag ng brow out ba babalik ulit kay battery mo kahit lvd na, for example nag set aq ng lvd @12.8v (12v system) or 25.6v(24v system) then lumipat nya sya kay DU pero biglang nag brown out babalik ba sya sa battery mode?
Sir ano po kayang problema ng snadi 3kw ko 00 po lahat ng reading wala na rin pong kuryente...bigla kasing nag trip
May channel ka na pala ha. Hahaha. Balik ako dyan mga July kuha ako ulit.
hahaha para mabilis mag guide
Meron bang snadi 3kw inverter na hindi napapasok ang parameter setting? Sagotin nyo naman...
Same lang po ba sa SNAT?
thanks
Gaaano kalakas ang charging power pag nasa grid priority at nag cha-charge ng battery?
Paano sir pumunta s mode 3
ok lng po ba na 24/7 nka.saksak sa du or sa meralco ang snat or snadi inverter?
Automatic from battery to DU sa 03 setting ng snadi ko. When that happens the lights in the panel shuts off but DU OK. But when my battery is full charge and floating Hindi automatic ang lipat sa battery from DU. Why po?
idol safe po kaya kung bababaan kopa hanggang 11.8v yung battery alarm?
bOSS SADYA BANG MAY SUPPLY VOLTAGE YUN INPUT 220V NYA KAHIT WALA KPANG KINAKABIT NA SUPPLY NA 220 GALING MERALCO?
\
bo5 at bo6 na settings sir sa snat
Hello Sir, this is informative po. Question po, is this settings are for gel or lead acid batt? How about po if lifepo4 yung batt ko, ano po yung tugma na b01 to b06 na settings para dito. I am using a SNADI all in one generator 1kw, 24V system po. Thanks in advance.
Check datasheet ng battery nio if anong applicable na baterry parameter
Sir papano mag change ng value ng voltage ex 13v gawin kong 14v bo1-bo6
apparently b02 b03 setting didnt work for me like you've demonstrated.
also snat/snadi inverter only give you 11.5v max as cut off point. masyadong mababa for lifepo4. gusto ko cya itaas to 12.8 para mas safe ang battery ko.
yan n ang limit 11.5V
Sir good po jan,wtchng frm cebu province.my tanong lng ako sir kung oki lng bah gamitin yung ac chargr ng snat kahit nka 48v yung snat koh?.slamt po...
pde nmn
Sir magkanu Po Yan solar system controller
Sir good day po, sir pahingi nmn ng input it anu dapat settings ni 3kw snadi sa gel type battery.. Tnx po.
Bakit hindi ko mapasok ang parameter setting sa snadi 3kw, naka 24 volts ang battery bank ko...kailangan bang naka 12vdc muna bago mapasok ang parameter setting? Sumagot naman kayo pls...
nagawa mo na setting mo? ganun din problema ko eh.
Sir ang 24 volts na snadi.normal lang ba na 12 volts display.pero 24 volts ang battery
yes
Bakit po yung inverter ko 24V pero yung parameter niya hanggang 12V lang? Ano po kayang problema sir? Sana po matulungan niyo ako sir. Thank you po
boss bakit naka 00 lng inverter ko
Pwede pp ba magpahelp sa pg install ng inverter namin
Sana pati input snat kung pwede icharge battery bank
mode 1 un
Ilan watts Po sir idle power consumption nyan.
Sir question. Sa function 01 grid priority, applicable ba yung b02, jan? I mean always charging lang ba sya hanggat may grid? At gagamit lang ng batt kapag wala ng ac charger?
Yes
Good Day sir. bat hnd ma reset ang snadi 3k inverter ko? please help
baka lumang version yan, yung hndi naeedit
sir ask ko lang bakit po sa gabi bilis mag transfer ng Battery-Grid Inverter ko sa gabi 2pc 12V 200Ah Blue Carbon Battery ko
1. possible malaki ang load. 2. Ang cut off ng snadi is 12V, so designed lng sya for lead acid battery, ndi mo pde idischarge ng 80% ang battery mo if may AC in ka kase magtransfer sya at 50%, if wala nmn, continous beeping nmn sya, 3. Possible ndi n mgnda status ng battery mo.
Help di ko mapasok parameters. Plesee help
Sir ask ko lang po
sir 24v system ba ito.. ang baba ng parameters....pang 12v system lang ang nakita ko ...mag multiply po ba ang 12v na setting para sa 24v...kasi yong lvr nya is 12v lang at ang charging nya is 13.8v lang..kong mag recon cya sa 12v or kahit na full charge na cya sa 13.8 paano to gagana na need nito is at least 24v...tama po ba na ang makikita kong setting is 12v pero mag multiply ang value para sa 24v...
times 2
@@leapelectricsolarservices8869 thank you! Eto yung hinahanap kong sagot. 24v system na 1kw sinesetup ko.
Sir ask ko lang po... Same po tayo ng inverter. Bakit pag nag battery over voltage na nag shushutdown na ang inverter... Halimba po ang battery ay fullycharge na 28.8v tapus ndi masyadong operarional ang mga appliances... Mag aalarm ang mppt cotroller ng battery over voltage... Tapus mag shushut down na si inverter... Ano po dapat gawin?
Pareho sa akin boss overvoltage rin kahit walang load.
possible inverter problem
Sir @denver. Pag shutdown you mean nag turn off si Snadi inverter? Halos kapareho tayo ng issue, if full charge battery tapos walang load, si snadi nagsswitch to grid priority (cutoff power) kasi wala nman ako AC input. Need ko pa irestart inverter.
Hello po
meron po akong snadi inverter 24v 3kw bakit kaya hindi ko ma open ang battery parameters setting? ano kaya possible cause nito? may model ba ng snadi na hindi changeable ang parameter setting?
Same. Di ko rin mapalitan parameters
Hi sir plan to buy 3kw snat inverter,then 5 pcs 405w pv,4pcsthen 150ah Gel type. 48v system Po sna Gawin ko.dun s BO2 50.4 ilalagay ko?
B02 is ung reconnect. So 13V *4= 52V pde na as reconnect voltage
@@leapelectricsolarservices8869 d q ko ma e adjust ung s parameter 12system parin ang andun sir.automatic nb un n c snat n mag x4?
@@carloaranzado6032 default is 12V tlaga sa screen
Yung akin ayaw magpalit sa b01 Sana may video ka po para sa b01 peru from bo2-bo7 nagchachange sya
B01 ndi napaplitan sa 2kw models up, kse magbase ang charging voltage sa battery selection mo U0-U7
Pag naka 03 setting po ang snadi with charger and solar panels are charging during the day and du is also on standby pag nag 12v to trigger charging which source will be priority? Du or solar?
DU
Thank you po
After operating my 3kW snadi for 2 months I noticed Hindi po automatic bumabalik sa battery even if batteries are floating. Why po kaya.? 03 setting po. From battery to DU automatic but from DU to battery Hindi po. Floating status na po. Please help and advice. Thank you
Also when the snadi transfers from battery to grid the lights sa panel turn off. Is it normal?
Boss Ilan ba normal setting sa Current nya? C3? or C4?
As much as possible malapit lng sa C-RATE ng battery mo
Question: kailangan bang naka mode 3 muna bago ma adjust mga parameter settings?
from off state
hindi ko pa rin ma set... pwede bang mag pa tulong mag set? @@leapelectricsolarservices8869
pwede kong dalhin sayo snadi ko?@@leapelectricsolarservices8869
boss..applicable din ba to sa 1kw 12v snadi inverter..
yes po
boss bakit kaya nagsha shutdown several times sa tanghali yung inverter ko kahit full pa battery? pag i on ulit wala naman nagpapakita na alarm
Possible lose connection or wire too thin. Ganyan sakin pag manipis wire or lumuwag
I'm not able to enter the battery parameter menu? i followed the instructions of this video and nothing. Does anyone know why?
Same concern. Tried again and again. Snat 4kw 48v
Sa akin din ayaw mapasok ang parameter setting
That is one of the problems with Snadi, little standardization. On my 2kw 24v unit I enter the settings by long, pressing the function button.
question pag nka mode 3 at nalowbat ang battery naka on din ba ac charging? kasi sa ibang video sa youtube sabi pag mode 3 daw hindi mag on ang ac charging pero sayo nag on ang ac charging. or pwede ba i disable yung ac charging?
pag may 220V AC input nkalagay automatic un
@@leapelectricsolarservices8869 yung iba kasi dito sa youtube at groups pg ngka mode 3 snadi/snat nila di nag on ac charge nila pag na lowbat. nag bypass lng pero walang ac charging that's why i got confused kasi ikaw lng ata nakita ko sa youtube ang nag ac charge sa mode 3.
@@hexlhieA wala talagang charging s mode 3. mode 1 lng merojg ac charging.
@@leapelectricsolarservices8869 im confused, upon looking noong nagtransfer sa AC yung inverter from battery nag function yung charging icon sa display panel? So does it mean it's charging or not? 🤔
@@rednaxela1256 If AC ang priority to supply sa load, yes it charges the battery ( Mode 1 )
Sir paano e set ang 60hz naging 50hz kasi sakin
saksakan mo ng 220V AC input
bakit kaya yung inverter ko,di ko ma set
Bka old model pp
@@leapelectricsolarservices8869 sir may iba kayang paraan para ma mai set ang parameter ng old model? salamat po
bakit kaya hindi ko mapasukan ang setting tama naman. naka off ang DU battery lang naka connect.
Bka old.model po yan
@@leapelectricsolarservices8869 siguro nga sir. meaning wala pong way to customize the settings?
Sir sa akin ayaw mamodify b01 charging 13.8 lng nakalagay peru sa bo2-bo7 mamodify nman ano kaya pwede gawin gusto mo San 14.8charging nya
Bakit po yung inverter ko 24V pero yung parameter niya hanggang 12V lang? Ano po kayang problema sir? Sana po matulungan niyo ako sir. Thank you po
gnun po tlaga 12V, times 2 lng kung 24V
@@leapelectricsolarservices8869 ganon po ba. Sige po salamat po sir