Part 4 of 5 - Snadi/Snat and Lifepo4 Battery Settings
Вставка
- Опубліковано 6 вер 2024
- Official Facebook Page:
www.facebook.c...
Please check out my other videos!
LiitoKala Smart Multi-battery Charger Review (Tagalog)
• Lithium Smart Multi-ba...
Ano ang gamit ng Solar Wifi Adapter?
• Solar Wifi Adapter. Pa...
UPS o Solar Back Up?
• UPS o Solar Back Up?
Off-Gird Solar w/ DC ATS (Tagalog)
• Part 5 of 5 - Off-Gird...
sir ano po purpose ng bms? nag chacharge po ba si inverter sa lifepo4 battery?
for balanced charging sir. lalo na kung multi cell ang gamit mong battery. ex sa 12 setup (4x 3.2 cells). ung 4 cells ay dapat properly balanced ang voltage to avoid over charging or over discharge. yes, may charging feature ang snadi
@@radical0720 salamat po response idol.
may ac charger po si snadi. pwede kang magcharge sa mga utility outlet
Maximum is 3,65 each cell you look at the data sheet
Thank you for your videos related to Snadi/Snat Inverter.
What settings would you recommend for flooded lead acid deep cycle batteries?
In my opinion, the factory settings are a little extreme.
sir uninterruptible ba ang power output ng snadi. from battery to DU, vise versa. pag nag cutoff ang battery...thank you sa sharing sir. God bless.
Salamat Sir sa mga videos mo.. Dami ko natututunan.. :)
marami salamat din po sa suporta
sir ganyan din inverter ko.. tpos nka 12v 100ah lifepo4 battery.. anu po recommend settings for B01 B02 B03 B04.. UPS mode Function 1..
salamat sir. very informative
Sir hindi ko machange ang charging voltage kahit i long press ko ang fucntion key Di lumilipat sa voltage. Pero sa BU2 BU3 BU4 ok naman lumilipat naman sa voltage at nababago ko ang volts. Bakit kaya? Hanggang 13.8 lang charging voltage naka lifepo4 ako 2pcs 100ah
Ahh ganon po pla sir pag 12v 1kw model
Pag sa 24v 1kw model I double lng Yung settings
So pag grid tie po use as ups ng snadi at lifepo4 bat kahit di na po gamit ng charge controller since pwede na iset sa inverter
pwede po.
Sir pag nasa mode3 or battery priority..pag nag lvd n mag chachange s grid lng pero hindi xa nag chacharge ng battery unless iseset mo xa s mode1 grid priority xaka lng magchacharge s battery.(snat)gamit q
Thanks for sharing that info sir. di ko pa din na test yan sa setup kasi may separate akong ATS.
nasa manual po Sir nakalagay talaga na switch to Grid pero di mag charge sa battery
Sir, what's the recommended settings for a Lifepo4 12v with BMS? should the settings coincide with the BMS settings? Thanks
I also have a SNAT/SNADI. The problem when you have a 24v battery is that SNAT/SNADI doesn't have setting for 24v. I don't know why. exampble sa BO1, if you have a 24v battery tapos e set mo to above 24v, it does not go beyond it. Sa akin eh 16v lang dina lumagpas
Automatic na yan nag double voltage sir pag set mo sa SCC...
Hi, I'm planning to use this inverter in UPS mode along with 100AH lifepo4 to power my 600w PC, what BMS ratings should I get?
what is your setup? 12v or 24v inverter? assuming that a 600w PSU has an active PFC, you may consider this formula (600w / 12vdc = 50a) or (600w / 24vdc = 25a)
What about the setting for lipo4 12volts 100ah bluecarbon Sir?
Sir pag mag charge ta sa mode 1 sa snadi.habang nka charge ung battery dba masisira ang battery pag mayroon load na frezer?ung sa kuryente diba malakas consumo habang nag charge c snadi? Salamat sa ans...
What is the SOC of 24v?
Kase saken eve battery cell from one point dapat 3.65 HVD pero 3.3 d na umaakyat mga battery ko (24v system)
Saan ang setting nang u1 to u7 battery type para ma change ang charging value ng b01 to b06, gamit ko po ay lithium battery na naka set sa u6 pero ayaw mag change ng value to increase b01.
Sir thanks for your informative video, nicely done! May tanong po ako, may snadi din ako, i would like to use its charging feature sana, pero pag continuity test ko ng L at N of ac input, ay nagbeep multimeter ko meaning connected pareho yung L at N sir, normal po ba yun? Meaning shorted. Nka off snadi ng ginawa ko ito. Diy lng din kasi ako sir at not a pro electrician. Thanks po s sagot sir God bless!
dahil sa tanong mo sir nag test din ako pero di naman shorted ung snadi ko. na try mo na ba gumamit ng actual load?
Sir kailangan pa po ba ng BMS kung discharging lang ang SNADI? Anyway may LVD naman ang SNADI.
Meron din po bang ganyang setting yung flloor mount type na snadi
sorry sir hindi ako sure. kung ang tinutukoy mo ay yung naunang model ng snadi inverter malamang limitado lang ung features nun
sir goodpm.. alam mo b kung bakit nagbebeep ang inverter ng every 20mins.. tatlong beep lang naman po..salamat
Sir , bakit ung lipo4 ko 14.6 volt pag naka AC, once battery mode bilang 13.6v lang nasa volt meter . Bakit hindi sya 14v+?
Hi, do you know how the snadi charge? Is it safe for lifepo batteries?
Yes, it is. The charging parameters and configuration were discussed in the video however it's in Filipino language. But if you could just watch the video itself, it demonstrates how the inverter is configured to support Lifepo4 batteries. Thanks for your time and interest.
Boss ano ang parameter dapat sa setting pag lifepo4 battery ko lead acid or gel type tnx
Ok Bosng.
ayos ito sir
Sir snadi at snat pareya lang po ang features?
hindi ba over charged si lifep04 sa 14.6?
hindi naman. pero to be safe, i set mo sa 14-14.2 ang hdv lalo na kung hindi properly balanced ung mga cells ng batt.
sir pwde bayan gamitin kahit anong klasi ng batterry??
Gud pm, paano e set ang setting ng snadi inverter kung naka bypass lang sya gamit ang grid pero di sya charging and the following day ay mag charge sya gamit ang solar panel? Anong function ang e se set up ko para bumalik sya sa battery priority mode? Yong bang b02 function ang e a adjust ko? Thanks
walang ganyan setup sir. either ups mode or off grid mode lang
ung B05 & B06 wala. B06 Battery indicate 100% ano dapat ung value?
May I know ano po config sir if I'm using
4pcs Great Power LIFEPO4 3.2V095Ah ?
Currently connected to 2pcs 150watts Mono 18v in parallel connection.
Currently set to B03 (battery priority)
b1 13.8v
b2 13.6
b3 12v
b4 11.5v
I think pang lead acid setup ko pero naka-LifePO4 ako.
Kind regards
pwede mo pa adjust ung b1 to 14.4 assuming that you have a bms. and if you have a bms, may sariling cutoff voltage ito designed for lifepo4 batt
ano pala brand ng panel mo? ambaba ng voc eh
@@radical0720 Salamat sa reply boss. Solar Home Mono. Nagdagdag ako 1 panel so 3pcs 150watts na sila
@@radical0720 how 'bout for b05 b06 settings mo sir? ano pwede mo ma-suggest? Thanks! Daly BMS 100a pala BMS ko
Sir ano po bah parameter from b01 to b06 if 200ah valve regulated lead acid battery ko...
Thankz in advance..
At saka ilang voltage po bah ang full charge ng 200ah valve regulated lead acid battery
ano ang voltage rating ng battery nyo sir? basta pag lead acid max voltage is 13.8 and lowest is 12.2
Sir ilan watts po yan?pwede ba gamitan yan na zander?
1kw sir. depende sa sander na gamit dapat di lalagpas ng 900w.
Sir d nya po ba tlaga Kaya paandarin Ang 200watts n ref pg my kasabay na 100watts n load Ang snadi.
malakas kasi ang current draw ng ref sir. ano ba ref mo inverter o hindi?
sir tanong ko lng kung san maglalagay ng load dalawa po kase ang ac output thanks
ung output sa may terminal block yun ang hardwire out put kung gusto mo i tap sa main box breaker box ang inverter at lagyan ito ng circuit breaker for protection. ung regular na output socket ay para sa mag standard load lang sa bahay.
Sir mau external ats ako. Pd ko b gamitin ung lvd ng snadi, main ko solar, reserve ko si du pag naglvd na si snat, mag switch kaya sya sa du?
pwede sir as long as tama ung wiring at ung rating ng ats is kaya. ung load mo
Ats ko sir 63A ang rating. Salamat po sa reply.
Sir good day, pwede po ba ang lifepo4 battery sa built in na charger ng snadi inverter? Salamat po.. @radical bytes
yes pwede po. kaso hanggang 12v lang ang upper limit ng Lvd neto
@@radical0720 sir pasensya na po, wala ako kasing idea sa mga ganito.. akala ko kasi pag nagka inverter ka, kahit anong battery nalng gamitin.. lol
Pero pwede naman po? Masisira ba agad yung lifepo4kng hanggang 12v yung LVD?
@@martstephen7405 pwede naman pero dapat monitored mo ung voltage ng battery. kung lifepo4 di dapat bababa ng 12v kasi madali ito masisira. kung gusto mo check mo ung ATS sa video ko and pwede ka mag message kay si Cris Varon via fb
@@radical0720 ok sir.. maraming salamat.. godbless
@Radical Bytes sir ano ang pinagkaiba ng tower type SNADI sa wall mounted?
Are these settings the same for those 100Ah+ lifepo4?
yes. but the one I got on the video is only for 12v setup
@@radical0720 Thank your sir. I'm using 12v 100ah. I want it to be set up as UPS (mode 1). What b02 settings should I use?
200AH 12v battery
Ano po magandang settings sa b01 to b04?
ano battery type na gamit nyo sir?
no need BMS?
on that setup, no. the battery is for testing use. pero if you have high capacity 12 or 24v battery, a bms is recommended.
Sir, pahingi ng input, puro research palang nagagawa ko so no actual experience, thinking of buying this one, baka makatulong input nyo since natest nyo na yung unit.
So yung function 3 basically inverter lang talaga sya na may auto switching between bat and grid depende sa voltage level na nadedetect nya from batt??? I read in one of the comments below na pag mag LVD sya di sya mag chacharge unless ilipat mo sa function 1? Tama ba? Pero it will stay in mode 3? So if gamitin ko sya as an inverter only and i have a separate solar controller and panels to charge the batt, ok lang. In which case I would probably do the same settings you did para kaya i top-off ng solar controller/panels ang bat before snadi starts drawing power from it again pag full cahrge nya. LVD cutoff at 11.5 puts it at 2.8v someting per cell (since 4s sya), i read online na for lifepo4 medyo ok na ang 2.7v as minimum discharge, some even say it can go lower with minimal effect (tho meron) so 2.8v is pretty good I guess. I think this should still be well above BMS over discharge protection values.
Sir what happens if the batt suddenly disconnects physically, not through the LVD ng inverter? Mag auto switch to main grid yung inverter im assuming and wait for the batt to reconnect, tama ba? Kasi I'm thinking maybe I could set the LVD of the solar controller (or some other circuit in between) to something like 13v that way the batts will never be fully discharged. And then mag rereconect sya sa inverter once fully charged na sya by the solar panels at which point mag switch back to batt powered yung inverter since nasa mode 3 sya. I'm not sure lang kasi if mag hihintay sa mode 3 yung inverter kung sakali mag disconnect yung battery through solar controller (kasi in that case walang madedetect si inverter na batt na physically connected to it since puputulin ni controller yung connection), baka kasi kelangan may batt na nadedetect ang inverter para gumana so im not sure if this will work. Baka mag reset sya or something.
Planning to build a small system to see its effect on our electric bill lol. Was considering this one as inverter since mukhang popular sya dito sa pinas.
salamat sa interest mo sa mga videos ko sir. to be honest i have not tested that scenario pero in theory, in function 3, if lvd kicks in then the load source swtiches to utility power thats the same principle as the battery gets physically disconnected from inverter. hence, inverter should switch to utility power source.
@@radical0720 ah oks, baka pwede nga gumana idea ko. Itong inverter kasi yung mukhang madami gumagamit na may ok na reviews din na mahahanap kaya pinagiisipan ko talaga na ito na or at least itong brand kunin ko kesa mag risk ako sa mga chinese brands na wala ako makitang reviews. Mahirap na bumili ng half the price tas masisira lang din. At least ito mukhang heavy duty. Salamat sa reply sir.
highly recommended ito ng mga solar enthusiasts sir.
Feeling slang lang..