Split Phase Growatt 3000 for the Off Grid Shop.

Поділитися
Вставка
  • Опубліковано 20 жов 2024

КОМЕНТАРІ • 28

  • @sethgold6950
    @sethgold6950 4 місяці тому +1

    Thank you so much!! You helped me a lot with my project. Greetings from Germany 🇩🇪

  • @tm510a
    @tm510a 2 роки тому +6

    Cool , Iv'e been running my bullet casting shop off of 2 growatts in split phase for over a year.

  • @jamesshowalter6362
    @jamesshowalter6362 2 роки тому +2

    Thanks for your business!!

  • @miguelcalderon326
    @miguelcalderon326 11 місяців тому +1

    Can I make a parallel setup with only one battery bank? Thanks

    • @kc79ta
      @kc79ta  11 місяців тому

      Yes, it is better to have only one bank. It will hook to both units.

  • @cowboymcq6711
    @cowboymcq6711 Рік тому +1

    With your busbars do you have anything behind them or is it just screwed to the board
    Just wondering because I’m making some right now for my 3. EG4 batteries
    Thanks for The realistic video signature Solar runs unrealistic loads and they show you their test of a few LED lights and a Skil saw

    • @kc79ta
      @kc79ta  Рік тому

      They are just screwed to the board with 1/4" spacers between the board and busbar. Thanks for watching.

    • @cowboymcq6711
      @cowboymcq6711 Рік тому

      @@kc79ta like plastic or some non conductive ?

    • @kc79ta
      @kc79ta  Рік тому

      @@cowboymcq6711 Yes, I used plastic.

  • @kingasapj3160
    @kingasapj3160 11 місяців тому +1

    Do you have 120 volts going to both growatt's? For charging? Or can you just use one to charge the batteries from a generator or shore power? Thanks so much for your time!!

    • @kc79ta
      @kc79ta  11 місяців тому

      Both, Once you set them up to run in Split Phase (240v) you will need to run 240v and split it down to 2-120v lines one for each Growatt. If you only run a 120 v line to one of the Growatts you will get alarm 15&16 for "Parallel input phase error". Ask me how I know, lol.

    • @kingasapj3160
      @kingasapj3160 11 місяців тому

      @kc79ta ok so if I only have 1 120volt leg I'll have to use my auto transformer to make 2 120volt legs that would work correct?

    • @kc79ta
      @kc79ta  11 місяців тому

      @@kingasapj3160 I can't say for sure, as I never tried that way, but as long as the transformer outputs 240v that you can split into 2-120v legs it should.

  • @boblatkey7160
    @boblatkey7160 Рік тому +1

    "Yeah i got to clean up some of this stuff". Ya think?

  • @richarddrais8851
    @richarddrais8851 2 роки тому +3

    If you have 3 can there be configured to 3 phase?

    • @kc79ta
      @kc79ta  2 роки тому

      Yes, according to the manual you can get 3 phase. I have never done this, so I can not tell you how well it works.

  • @jimginnyohio
    @jimginnyohio 2 роки тому +2

    Nice!

  • @infosbm
    @infosbm 22 дні тому

    Maximum how much watt i can take

  • @diysolaradventures7894
    @diysolaradventures7894 3 місяці тому

    so only 240v from that one inverter on the hot and neutral ? would the other inverter remain at 120v and can both inverters run at 120v ?

    • @kc79ta
      @kc79ta  3 місяці тому +1

      It takes both set-up in split phase for 240. Hot on inverter1 to hot on inverter2. Hot to neutral is only 120v. Yes, both units could be set-up to run at 120v in parallel mode.

    • @diysolaradventures7894
      @diysolaradventures7894 3 місяці тому

      @kc79ta okay thanks I have 2 identical 120v 24v 3000 watt solar hybrid inverter chargers here running eifht now but they don't have the parallel option

    • @donniegeeter797
      @donniegeeter797 2 місяці тому

      Do you happen to have a wiring diagram for your set up?

    • @kc79ta
      @kc79ta  2 місяці тому +1

      @@donniegeeter797 Only the one from the Growatt manual with you can find on their website en.growatt.com/

  • @Fritsvrolijk
    @Fritsvrolijk Рік тому

    Hello can you if you have a 10 kw inverter make it by software a 8 kw inverter ????

  • @bianchispurs
    @bianchispurs 2 роки тому +1

    Hello, I am doing the same set up, so the slave unit only needs battery cables to it, no ac? and the master will be 120 and the slave 240? Thank you.

    • @kc79ta
      @kc79ta  2 роки тому +1

      Hi, Both units will have AC out connections. Master will have L1 and neutral, and slave will have L2 and neutral. Both units output 120 volt. The communication cables go between both units causing the units to operate perfectly out of phase of each other giving you 240 volt between L1 on master and L2 slave. And of course the Grounds will also be hooked up.
      The same goes for the AC input if you choose to use it. You will need a 240 volt supply and run L1 to one unit and L2 to the other, or so I heard. I can not confirm this at this time as I do not have the AC Input hooked up on mine. I have been charging by solar only.

    • @bianchispurs
      @bianchispurs 2 роки тому

      @@kc79ta Thank you! and if I have A C in, will it go to both units? Thanks!

  • @JayDee25895
    @JayDee25895 2 роки тому

    they come already boxed from china.