Accuracy class of Current Transformer | Explained | TheElectricalGuy

Поділитися
Вставка
  • Опубліковано 28 лис 2024
  • This video explains the different accuracy classes of current transformer. CT Accuracy class are explained in a very easy method and inline with the IEC standard. You'll understand about the Measuring class and Protection class of current transformer.
    Substation Simplified course : courses.theele...
    Circuit breaker control schematic masterclass : courses.theele...
    5P10 or 5P20 class of CT : • 5P10 & 5P20 Class of C...

КОМЕНТАРІ • 19

  • @rezafaraji653
    @rezafaraji653 5 місяців тому

    Even after watching old videos multiple times after months, there are still lots of HELPFUL content. Thank you, Gaurav J!

  • @bilalkhan-py8jk
    @bilalkhan-py8jk Рік тому +4

    Greetings from Pakistan sir you are providing valuable content. Keep it growing

  • @prdschools9525
    @prdschools9525 Рік тому +3

    Second viewer from Nepal , please keep making as like this video sir

  • @GagandeepKaur-jj7jy
    @GagandeepKaur-jj7jy 8 днів тому

    Very well explained... Great👍🏼

  • @mohammadbahrami4341
    @mohammadbahrami4341 Рік тому +5

    The protection accuracy is also depends on magnitude of short circuit current. For example the 5P20 shows the accuracy of 5 % at 20 times rated current at primary. Therefore in my idea just saying 5P protection core is not accurate. The maximum short circuit current should be stated as well.

  • @kousikbhowmik6473
    @kousikbhowmik6473 11 місяців тому +2

    Great job man keep it up .... I highly appreciate your effort. Your vedios are very helpful.. Like you from Bengal

    • @GauravJ
      @GauravJ  11 місяців тому

      Thank you! Do share !

  • @dianasab1
    @dianasab1 6 місяців тому +2

    Saturation of CT may also please be elaborated.

  • @surendrakverma555
    @surendrakverma555 5 місяців тому

    Very good. Thanks Sir 🙏🙏🙏

  • @kaihannoman
    @kaihannoman 3 місяці тому

    Great course. But can you provide videos for IEEE standard? It will generate more subscribers for sure.

  • @narasimharao297
    @narasimharao297 Рік тому +1

    Thank you sir

  • @ritamishra9525
    @ritamishra9525 10 місяців тому +1

    Osm❤

  • @avinashsingh2259
    @avinashsingh2259 Рік тому +1

    Sir please substation equipment testing par ek course bnaiye. Kyo jo v experience log hi interview me testing se questions pucha jata hai or ham log operation vale hai answer nhi kar pate. Sir plz ek aisa course bnaiye ko jo testing nahi v kiya hai vo ekdam har question ka answer de sake.

  • @nombili
    @nombili Рік тому

    Good content 🙌🏻. Can you please do a video about relay coordinations Sir

  • @transmissionlinetricks9760
    @transmissionlinetricks9760 Рік тому

    Plz make video on surge arrestor name plate,

  • @marimuthum7936
    @marimuthum7936 Рік тому

    Difference between DRY AND WET transformer .

  • @prdschools9525
    @prdschools9525 Рік тому +1

    Sir please make a video about negative sequence protection schemes

  • @SHANUDAS-x7b
    @SHANUDAS-x7b 11 місяців тому

    I WAS ASKED IN AN INTERVIEW AND I AM NOT SURE OF THE ANSWER
    Q-WHAT WILL HAPPEN IF I CONNECT A PT IN SERIES TO THE LINE ? (SPECIFICALLY ASKED ME ABOUT THE HEALTH HAMPERING)
    ANS- THE PT WINDINGS WILL BURN , INSULATIONS WOULD DAMAGE , BECAUSE PT IS A STEP DOWN TRANSFORMER , WHEN PUT IN SERIES TO LINE , THE PRIMARY CURRENT IS THE LINE CURRENT WHICH IS QUITE HIGH AS COMPARED TO THE CASE WHERE PT IS PUT IN SERIES , THE SECONDARY CURRENT WOULD BE MUCH HIGHER , AS PT WOULD HAVE SECONDARY OPEN , WHEN HUGE CURRENT FLOWS THROUGH THE OPEN CKT , IT CAN DAMAGE THE VOLTMETER AS WELL AS HUGE BURNOUT IS POSSIBLE FOR ITS HIGH CURRENT
    SIR IF YOU COULD CHECK MY ANS AND RECTIFY ME , OR ADD SOME POINTS TO MY REASONING I WILL BE GRATEFUL

  • @avinashsingh2259
    @avinashsingh2259 Рік тому +1

    Thank you sir