Design of sloped footing

Поділитися
Вставка
  • Опубліковано 23 жов 2024

КОМЕНТАРІ • 8

  • @anand4236
    @anand4236 2 роки тому +1

    Where is one way two way shear check ?

  • @hs.markandeyahonnalisiddap5534

    Take B equals 1000mm and
    redesign

  • @sreerejm8540
    @sreerejm8540 4 роки тому +1

    SIR ,for the development length check, should'nt we take the dia of the column reinforcement i.e 20mm given .Also check for legth with Cy rather than Cx since Cy is only 870mm?

    • @SagarJotani
      @SagarJotani  4 роки тому +1

      Dear Shreerej M, development check is done for the bottom (x & y) reinforcements. Where we'll decide weather the bottom bar is to be kept straight or bent or hook.
      While calculating the development length for main bar of column, we will definitely consider diameter of column reinforcement only.

  • @walidal-jobrani3181
    @walidal-jobrani3181 3 роки тому

    sir why u didn't add the cover to d2 ?! while u add it to d1

  • @wyrshasuchiang4409
    @wyrshasuchiang4409 4 роки тому +1

    How is R value = 2.76 determined?

    • @SagarJotani
      @SagarJotani  4 роки тому +2

      For Fe 250, R=0.148×fck
      For Fe 415, R=0.138×fck
      For Fe 500, R=0.133×fck
      So in our case, Fe=415 and fck=20
      So, R=0.138×20=2.76

    • @wyrshasuchiang4409
      @wyrshasuchiang4409 4 роки тому +1

      @@SagarJotani Thanks a lot!!