Solar Panels Protections | Dc Breakers | Dc Fuse | Dc Spds | Complete Details

Поділитися
Вставка
  • Опубліковано 6 вер 2024
  • Solar Panels Protections | Dc Breakers | Dc Fuse | Dc Spds | Complete Details
    #ziewnic #fronus #solarsystem
    Benefits Of Solar Dc Protections
    A DC circuit breaker is an OCPD that protects electrical devices operating with DC and contains additional arc-extinguishing measures. DC circuit breakers are a relatively new technology to most homeowners since most devices used in a house work with AC and AC circuit breakers.
    DC Fuse. The DC fuse opens or breaks the circuit when the excessive current flow through it. The only difficulty with the DC fuse is that the arc produced by the direct current is very difficult to extinct because there are no zero current flows in the circuit.
    Surge Protection Devices (SPD) are used for electric power supply networks, telephone networks, and communication and automatic control buses. The Surge Protection Device (SPD) is a component of the electrical installation protection system. ... It can also be used at all levels of the power supply network
    The box consolidates the amounts of cables running into the inverter. Less cables equals more savings on material costs and labor costs. You also are adding enhanced protection to your inverter by installing a combiner box. These boxes provide protection from overvoltage and overcurrent flowing into your inverter.
    Subscribe To Our Other Channels
    🟢Whatsapp: wa.me/92307623...
    🌐Website: www.fbelectronics.com
    🔴UA-cam: / @fbelectronics62
    📚Facebook: / farrukhbrotherselectro...
    🔴Instagram: farrukh_brothers_electronics

КОМЕНТАРІ • 39

  • @muhamadfurqannadeem2588
    @muhamadfurqannadeem2588 2 роки тому +2

    Sir aisi video ka hi intezar tha. Apka bohat bohat Shukriya.

  • @ahmadgull8471
    @ahmadgull8471 2 роки тому

    ماشاءاللہ بہت اچھا زبردست

  • @samishaikh8740
    @samishaikh8740 Рік тому

    Good 👍 and informative.
    Well done 👍👍

  • @bilalhasssan7109
    @bilalhasssan7109 2 роки тому

    Good guideline👍, Thanks bro

  • @muhammadabusafyan5417
    @muhammadabusafyan5417 2 роки тому

    Nice work 👍

  • @ahamdjaveednoori6376
    @ahamdjaveednoori6376 2 роки тому

    Useful info thanks

  • @jarwar110
    @jarwar110 2 роки тому

    Nice

  • @munirahmad1090
    @munirahmad1090 2 роки тому

    good

  • @jarwar110
    @jarwar110 2 роки тому

    Sir fuse strings m use hoti hain aap ek video strings fuse calculations par b banain boht acha laga video dekh kar or spd earthing k bari m b lighting earthing pv model earthing and system earthing

  • @attiqueahmad6707
    @attiqueahmad6707 5 місяців тому +1

    every thing based on self experience ,,,,,,so most of stuff he is saying is technically wrong

  • @fasnuf
    @fasnuf Рік тому

    I wish I understood this. I need the info.

  • @sohaib.s1573
    @sohaib.s1573 9 місяців тому

    Ongrid inverters ma Wapda ke side sa surge protection ka kia tariqa ha?

  • @UmairRaza-ef8zs
    @UmairRaza-ef8zs Рік тому

    3.2kw k system k lye Dc breaker kon sa use hn ga.

  • @shahzadmasood3176
    @shahzadmasood3176 2 роки тому

    BAHI U STUDY SCHNEIDER BOOKS PLEAS

  • @munirahmad1090
    @munirahmad1090 2 роки тому

    salam bhai

  • @muhammadabusafyan5417
    @muhammadabusafyan5417 2 роки тому

    3 KW inverter best inverter ???

  • @NazimUdDin-tg8jg
    @NazimUdDin-tg8jg 2 роки тому

    Sir breaker parallel connect hota h aur current ki protection deta h .
    Aur fuse series mn connect hota h .

    • @fbelectronics62
      @fbelectronics62  2 роки тому +2

      Bhai Saab Breaker Fuse Connect He Series Hota Hai Ap Kider Ghoom Rahay Ho
      Spd Breaker ya k parallel Connect Hota
      Research Karain Thori
      Ap nay 1 Second Mein Duniya He Badal D

  • @yousafjan4459
    @yousafjan4459 2 роки тому

    Sir inverter kay sitting par viduo banay

  • @SuperEvo1990
    @SuperEvo1990 2 роки тому

    dusri baat kuch fuse atay hai jo k breaker se zyada jaldi act kerte hain or woh large battery bank mein lagaya jata hai jaise 48 volt ki 15-20 Kilo Watt ki battery mein. Fast-acting Class T-Fuse

    • @fbelectronics62
      @fbelectronics62  2 роки тому +1

      Yeh to unko samjhao jinko pata na ho mein to wo baat kro jo Pakistan Market mein hai or ho raha hai 😅 😆

  • @MAneel-fu5vv
    @MAneel-fu5vv 2 роки тому

    solar dc system me earthing kaisay karen

  • @baqarrizvi8740
    @baqarrizvi8740 10 місяців тому

    dear sir, 6 kva inverter ha , 8 panels hen 410 watts ke . plz bta den kis value ka DC breaker lagao, aur 100 ah ki 4 batteries hen tu batteries pe kis value ka lagon . Jazakallah

  • @shahzadmasood3176
    @shahzadmasood3176 2 роки тому

    dc spd with must be dc mcb breaker u study schneider book

  • @SuperEvo1990
    @SuperEvo1990 2 роки тому

    bhai inki earthing inverter ke earthing ke sath bond nahi ki jati woh direct main panel mein jati hai or wahn se true earth ground hota hai.

  • @muddassirmalik1456
    @muddassirmalik1456 11 місяців тому

    سر میرے پاس ایک 540 واٹ کا سولر پینل ھے اور 60 ایمپئر کا Mppt چارج کنٹرولر Simteck کا ھے میں نے بیٹری اور کنٹرولر کے درمیان اور سولر پینل اور چارج کنٹرولر کے درمیان کتنے ایمپئر کا سرکٹ بریکر لگانا ہے

    • @OptionTrading-mc6ib
      @OptionTrading-mc6ib 11 місяців тому

      13amp circuit breaker for solar panel 63amp circuit breaker for battery side

  • @3xodustech936
    @3xodustech936 5 місяців тому

    Breakers are faster than fuses😂 ye aj nayi baat pta chali hy ??? 😅😅

    • @fbelectronics62
      @fbelectronics62  5 місяців тому

      Don't mind
      Ok please I have a question why we don't use fuse in our electrical and electronics wiring system or DB box?
      Please give ay technical logical experience based answer not Google search based answer

  • @zahidreaction760
    @zahidreaction760 2 роки тому

    Bhai ap n khud hi 1.2 inverx inverter mn soler pr 32a DC lgana kaha tha or 16a ka keh rahe hn

    • @fbelectronics62
      @fbelectronics62  2 роки тому

      Good Question
      Mein Nay Video Mein Ratings Bhe Batai Hain
      1.2kw Ka Mppt 50Amp Ka Hota Us Jo Input Do Gay Usi Hisaab Sy Lagay Ga
      Jo 500v Mppt Wala Inverters Hotay Hain Unki Pv Input 27Amp Hoti Hai But Breaker Ap Nay Input String K Hisaab Sy Lagana Hota Hai

  • @RizwanKhan-en8ch
    @RizwanKhan-en8ch 2 роки тому

    Jis inverter main build in SPD ni arahai, usme lagana must hy bro,,,, 1000 companies SPD bana rahy hy kia ye sab pagal hy???? jo kam ni karta our darha darh bana rahy hy international market k lie...🙄

    • @fbelectronics62
      @fbelectronics62  2 роки тому +1

      Mein Nay Recently 220kw Ka Project Kiya Original Schenider K Spds Purchase Kr k Lagaye Tha Box Pack Short Niklay Wo Jiss Ki Wajah Sy 2 Din Hum Khaptay Rahay K Fault Kidr Hai Jo Insulation Resistance Ki Protection On Kr k Beth Gayaa Inverter So Is Liay Jo External Spds Hai Mein Unk Khilaaf Baat Nahi Ki Ap Meri Video ko Ankhen Band Kr 3 4 Dafa Sunain Apko Samjh Ajay Ge Mein Baat Kaya Ki Hai
      K Spds Short Ho Jatay Jisski Kisi Ko Khabar Tak Nahi Hoti Wo Khabar Mein Bht C Jago Par Dekha Installer Hazraaat Earth wali Wire Nikaal Detay Spd Ki Yaa Lagatay He Nahi
      But Jo Built-in Hota Hai Wo Type-II Ka Ata Hai Jo Protect Karnay Pr Automatic On Ho Jata Hai
      Or Meri Video Apk Liay Zayaa To Ho He Gai But Koshish Karain Agar Dobara Agar Meray Point ko Smjh lain Ap🤥

    • @RizwanKhan-en8ch
      @RizwanKhan-en8ch 2 роки тому

      @@fbelectronics62 Bhai Schneider k copies hum khud Pakistan me bana rahy hy, islie to masly aty hy.... Pakistani awam ki to sirf paisy kamany ki soch hy service deny ki ni,,, ap apni jaga tik ho lekn imported SPD main wazih green and red screen dia hota hy. jis sy short and open ka pata lag jata hy

    • @fbelectronics62
      @fbelectronics62  2 роки тому +1

      Apk liay special video banaoun ga is topic pr but usk bad ap kaya karo gay jab spd ko khol kr apko frod dikha do chahy imported ho phir ka batayeb