Chillar what er mak up piper whayr msind flow switch damges lorde come systom damge cirulshion fan condeshion popef all good condshion need totly comprssar gas systom all good ways
Salam. Sir working in sudia Arab in farma industry I work in chiller 261 ten we replace the condenser water tube so we vacuum the system and fill oil and fill the freon now compressor giving highi pressure alarm chiller carrier
Kaise h sir aap i hope aap thik honge mujhe ye knowledge chahiye tha ki hum mcs magnum control ko kaise change kar skte h or kya program karne ki jarurat h yor program hum khud kar skte h
Sir mera chiller (voltas 130 ton) compressor bar bar jalke ground fault horaha hey. Electrical ka sob ok hey supply voltage ,contactor ,spp,controller etc . 10 se 15 seconds chalta hey uske bad a condition ho raha hey . Abb tak 5 compressor jol chuka hey . Any solution or suggestion please ....
Assalamulaikum wr wb boss motor protector blanking light red colour what is the problem same device boss but isme Alarm aa rah h safety Alarm please can you explain
Check loose connections from ssps check compressor overheating or not during triping time and check 11 to 14 showing continuity or not do one thing of chiller main breaker and then on after then check
Very use full information..thanx
Very useful video
. thanks bhaaiiiii...
very nice bro ....well understood...thanks...
Excellent brother keep it up 🤝
We're good explain about chiller
Thank u bhai good explanation
Nice information sir
Excellent bro bravo and salam
Chillar what er mak up piper whayr msind flow switch damges lorde come systom damge cirulshion fan condeshion popef all good condshion need totly comprssar gas systom all good ways
Nice video bahi Tanuku you
Nice information
Nice job
good job
Always you top in experience
Thanks sir
Thanks
Nice
Thanks 🙏 sir
Good
Wa alaikum asalam
Please discuss part winding cannection
Please discuss partwinding cannection
😀👍👍👍👍❤️
Hi sir suctoin dishcharge super hit dono ke bare me bataye please
ua-cam.com/video/_RLmT4s4wzI/v-deo.html
Bhai safety rale ka millga.
Chiller always lockout low suction superheat or high discharge superheat please reply
Why aircool chiller and watercool chiller aproch temperature different
Baki wair kis chij ka he
Salam. Sir working in sudia Arab in farma industry I work in chiller 261 ten we replace the condenser water tube so we vacuum the system and fill oil and fill the freon now compressor giving highi pressure alarm chiller carrier
How can we find motor winding protecter in Saudi Arabia market
Bhai Zamil chiller asy490 iske bare me boliye plz bhai
Why mp trip alarm came when chiller off condition, if I reset 2 ya 4 chiller running against same alarm coming
Thank you for good information
Iss Ka alarm kya aayeg sir display ke upr
Tell me
Can you show me alarm ??
SSPS alarm or SSPS trip
@@mskengg
Thank you 👍
Kaise h sir aap i hope aap thik honge mujhe ye knowledge chahiye tha ki hum mcs magnum control ko kaise change kar skte h or kya program karne ki jarurat h yor program hum khud kar skte h
Hi ji, how to cheak chiller working condition normal, or bad? Can you please tell me
Sir compressor current overload perameter is not set indication arahi ha iska btaen plz
Ok
ssps troubleshooting, plz. Bro
Sir chiller mai delta t ke bare mai bataye
Ok I will make a videos
Oil temperature sensor ,oil pressures sensor keise check kare ketena OMS leta he please.
1 or 2 no kis chiz ka sensor h ...aap sure ho wo sensor ka h 1/2..........
pare english please im watching you brother
Assalam alaikum bro can I get wiring diagram load unloading
Zamil air cooled chiller high pressure switch fault show kr rha hai
Assalamu wa Aalikum Chiller ki wiring pe ek video banayie
Ok bro
Sir mera chiller (voltas 130 ton) compressor bar bar jalke ground fault horaha hey. Electrical ka sob ok hey supply voltage ,contactor ,spp,controller etc . 10 se 15 seconds chalta hey uske bad a condition ho raha hey . Abb tak 5 compressor jol chuka hey . Any solution or suggestion please ....
Bhai WINDTEMP alarm ka kia karan hai batao plese bhai troubleshooting batao bhai jaan please 🙏
Ok i will make a videos for the topic
What is the reason compressore mp trip skm chiller ..... Can u explain bro
Check CT coil
@@mskengg ct coil connected main contactor
Control ka power Nahin a Raha क्या-क्या check Karen
Motor protection Devices
Ssps ko hi motor protection bolte hai kya
Yes
Part winding ka video hai sir,
Link de ya bana de
Ok bro
Asalmualykum
Kya high voltage par bhi ye cutoff karega
Only for high winding temperatures, high oil temperatures, reverse rotation, single phasing
@@mskengg thanx a lot.
What about low oil temperature? It’s also tripping?
Bhai automatic pump down kaise hota hai
I will make a videos
Can you translate in english interesting your explanation
Pool sensor meaning what?
Assalamulaikum wr wb boss motor protector blanking light red colour what is the problem same device boss but isme Alarm aa rah h safety Alarm please can you explain
You can check all 3ph voltage ok or not if three phase ok so you can check settings in the uvm
Maybe single phasing
SSPE change compressor not working. Plz answer same SSPS
You can check your overload witch is in the compressor terminals
Hello, we have a compressor se-e1 alarm and the compressor turns off, what could be the reason?
Check incoming Voltage if it is ok then need to change SSPS module
@@prakashprajapati1872 Thank you
ap dubai ayega
Yes aega
Whatsapp number give me . I want Details talking. @@mskengg
Is ssps use in only screw chiller?
Used on 3 phase compressor any type
Thanks sir
Plz chiller password zamil.
Ssps aj mryy chilr main falt aya hn
Ssps alarm compressor off. Plz answer
Check loose connections from ssps check compressor overheating or not during triping time and check 11 to 14 showing continuity or not do one thing of chiller main breaker and then on after then check
@@mskengg main breaker. off same alarm. Again
@@shaikhnaushad6292 need to replace ssps i think in side ssps relay week
@@mskengg ok replace. And check. Tanuku. you. Sir
😭 sorry
Dear brother ,
Thanks for the video and knowledge sharing ,i need your number pls share me below thanks
Hllo sir plsss snd ur wtsp nmbr
sir app se ak sawal karna hai plz whatsapp number send kijiye mera saudi me chiller technician me kam huwa hài sir me ja sakta hu plz fast Reply
Why mp trip alarm came when chiller off condition, if I reset 2 ya 4 chiller running against same alarm coming