troubleshooting tankless Part two

Поділитися
Вставка
  • Опубліковано 21 жов 2024

КОМЕНТАРІ • 28

  • @adamr1637
    @adamr1637 Рік тому +4

    Thank you for the excellent presentation!

  • @mobilecommunicationsnetwor5268

    Any thoughts on the Japanese products like Rinnai it's really being pushed marketed strongly in our area?

  • @lannymong2180
    @lannymong2180 8 місяців тому

    How would you replace the heat tubes if necessary?

  • @lannymong2180
    @lannymong2180 8 місяців тому

    This VERY informing video! But didn’t explain replacing the burner box?

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  8 місяців тому

      well You have to take the whole thing apart to get to that .. that's a chore there , I have done it a bunch of times. but labor will cost more than just getting a new one.
      Next time the guys bring me a frozen one I do a complete tear down

  • @GB-jc1ek
    @GB-jc1ek Місяць тому

    Great explanation. Thank you very much

  • @lannymong2180
    @lannymong2180 8 місяців тому

    Mine supports the household water; plus water for my Rheems hydronic furnace. The techs are saying my furnace is not getting enough hot water flowing through the furnace to fully heat the house; and there must be a problem with your Rheems tankless heater. Any suggestions?

  • @timbrowning6822
    @timbrowning6822 9 місяців тому

    Our Rinnai has never given an error code. But we lose hot water after being in the shower. We had the unit serviced and we are still having issues. I usually take my shower early and never have a problem. But my wife starts her day later and has the water start out hot to go cold. But this doesn’t happen all the time. We have removed the filters in the shower heads. It can also happen with in any shower. Would a pressure regulator help any or is there another reason this is happening?

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  8 місяців тому

      It sounds like a low-pressure issue. more people using more water later in the day? Maybe... Call the water dept.

  • @mobilecommunicationsnetwor5268

    From a reliability standpoint have you seen a clear winner with one of your manufacturers?

  • @ArnoldZiffle-jw2mv
    @ArnoldZiffle-jw2mv Рік тому

    Mine just had a tripped breaker on the electrical outlet because of something else that was plugged in to the same outlet. Luckily found it before I tore mine apart. Whew.

  • @mosheshp1
    @mosheshp1 10 місяців тому

    great explanation! very helpful!!!

  • @timatkin6282
    @timatkin6282 Рік тому

    error code 66 (bad mixing valve) is this a common problem on these? does replacing the mixing valve resolve this issue?

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  Рік тому

      The bypass and control valve is one of the top issues I have with these. but , maybe one or two a year and we install 1000's

  • @RobertEadeh
    @RobertEadeh 11 місяців тому

    Is it possible that code 11 is only igniter coil problem only. ?

  • @yovanisaavedra1311
    @yovanisaavedra1311 6 місяців тому

    Right now I don't have a dollar bill.😅😅😅 Thank you sr

  • @tunnelwind1
    @tunnelwind1 Рік тому

    i have this type water heater. and now its giving me a code 65. what is it asking for.

  • @jlfreezingmaster1093
    @jlfreezingmaster1093 Рік тому

    I like your videos greetings

  • @thomascbeaty
    @thomascbeaty 9 місяців тому

    Thank you sir

  • @larrytheplumber9851
    @larrytheplumber9851 Рік тому

    Through it out start all over

  • @paladiobienesraices
    @paladiobienesraices Рік тому

    i have a bosch 5600, and is making a high pitched noise cant find solution, do you have any experience on this ua-cam.com/video/fHZD27PZNeA/v-deo.html