Copper pipe to pex shut off for washer

Поділитися
Вставка
  • Опубліковано 17 тра 2023
  • Copper pipe to pex shut off for washer. This is how you can easily go from copper to pex pipe. All you will need is a few tools. Here are a few things below from Amazon. If you use my affiliate links below, I get a small commission. Thanks! @GrantKeysProperties
    Pex red 50 ft! amzn.to/486gTQ0
    Pex blue 50 ft! amzn.to/3RdBDhW
    Copper cutters! amzn.to/3RcTJkk
    Pex Crimp Tool & cutters set! amzn.to/3RzgP5U
    Crimp rings! amzn.to/3t8cuxg
    Teflon tape! amzn.to/46RFaIL
    Shark-bite Fitting to go from copper to pex! amzn.to/3Ry3iLN
    my UA-cam channel link
    / @grantkeysproperties
    #Copper to pex#Pex to copper#Changing copper to pex#Pex off of copper how to#Run pex off copper how to#How to go from copper to a pex shut off valve#Copper pipe to a pex shut off how to#How to run pex off of copper for a washer

КОМЕНТАРІ • 18

  • @GrantKeysProperties
    @GrantKeysProperties  Рік тому +7

    Don’t think I mentioned to shut off the water at the meter for this one! Or you will have a wale of a wash 🧼.😮

  • @billgamble5717
    @billgamble5717 7 місяців тому +2

    Thanks for the video!

  • @Soloveis
    @Soloveis 4 місяці тому +1

    Thank you man, very nice "how to" video

    • @GrantKeysProperties
      @GrantKeysProperties  4 місяці тому +1

      Thank you!! I appreciate you reaching out to me and I’m glad I could help!

  • @trukngal
    @trukngal 7 місяців тому +1

    Absolutely awesome, thank you for viedo

    • @GrantKeysProperties
      @GrantKeysProperties  7 місяців тому +1

      Thank you! I really appreciate you reaching out to me and I’m glad that I could help!

  • @jamesbutler4877
    @jamesbutler4877 5 місяців тому +2

    Get a pex fitting with a sodier side to put to the copper cos that sharkbite will not last forver .

    • @GrantKeysProperties
      @GrantKeysProperties  5 місяців тому +1

      It doesn’t have to last forever. When I have the time and extra money, I will end up re-piping the entire property with pex. So there is no need to. But thank you for the tip.

    • @jamesbutler4877
      @jamesbutler4877 5 місяців тому +1

      Just wanted to mention push connections should be temporary

    • @GrantKeysProperties
      @GrantKeysProperties  5 місяців тому +1

      @@jamesbutler4877 That’s a fair statement I guess. I worked with a plumber for 2 years and they did the sodier one, copper to pex fitting, like you said, is the best option for a permanent fix.5 years and beyond probably do the best option. But in my case, the shark bite fitting is the best option because I’m going to reroute and redo the entire house through the ceiling because it’s a slab and has copper in the slab. I don’t want or care to jackhammer on this one. The shark bite fitting that I used is good for many people in many situations, and is probably the best option for a homeowner, considering that soldering takes quite a bit of skill and would cost more money to buy the stuff just to do the fitting and the fitting will also cost money as well, I agree with you 100% though. I just don’t want everybody to see it and think that the shark bite fitting I used is no good because it is good in mannny situations and is the easiest fix for anyone. As long as it’s not intended for a very long time. Or they could fix it, and when it leaks, they could fix it again easy no problem opposed to the soldering.

  • @jamesbutler4877
    @jamesbutler4877 5 місяців тому +1

    I don't think code always to to use push connect fittings behind a finished wall and I understand I've used for a quick temporary fixmyself .

    • @GrantKeysProperties
      @GrantKeysProperties  5 місяців тому +1

      Maybe, maybe not, depending on your location. In my case the wall is not closed and the fittings now accessible. That way I can see it’s performance and get to it fast and easy. Thanks for the info!

    • @privacyinvasion7166
      @privacyinvasion7166 2 місяці тому +1

      The shark bite fittings are 100% allowed for permanent behind wall use by the manufacturer and code. The fittings you are thinking of that are not allowed behind walls are compression fittings. In fact you even bury shark bite fittings underground as long as you use the manufacturer approved sealing tape to wrap the fittings.

    • @GrantKeysProperties
      @GrantKeysProperties  2 місяці тому +1

      @@privacyinvasion7166 Thanks for reaching out that’s great info. I love using them when it makes sense!

  • @johnjobber2219
    @johnjobber2219 Місяць тому

    Shark bite behind the wall not a good idea

    • @GrantKeysProperties
      @GrantKeysProperties  Місяць тому +2

      @@johnjobber2219 These shark bites would not be inside a wall. They would be inside the box friend.