Sprinkler 4 outlet converted to 2 outlet zones

Поділитися
Вставка
  • Опубліковано 13 жов 2024
  • The 4 index valve i put the new valve for 2 zones

КОМЕНТАРІ • 31

  • @lauderdale4lif
    @lauderdale4lif Рік тому +1

    Thank you I have this same situation and looked everywhere to figure out how to change it without replacing the whole unit!!

    • @oscarperez08
      @oscarperez08 Рік тому

      You’re welcome!

    • @lauderdale4lif
      @lauderdale4lif Рік тому

      @@oscarperez08 is there a name for that part?

    • @oscarperez08
      @oscarperez08 Рік тому +1

      Well look for something like this.. for example
      K-Rain 4000 Series 4 Zone Cam For 6 Outlet

  • @miguelcarrizo8499
    @miguelcarrizo8499 2 місяці тому +1

    Antes tenia 4 zonas entonces tiene 4 pin en el time ud cambio para dos zonas saco dos pin en el time o no es necesario

    • @oscarperez08
      @oscarperez08 2 місяці тому

      Hola, si tiene que dejar dos pines por separado para que cada uno controle la zona que dejo habilitada.. el mio tiene 2 pines unidos para un lapso de 30 minutos por zona.. usted escoja cuantos pines le deja.. recomendado es 30 minutos de agua por seccion
      Saludos

  • @julieengstrom4591
    @julieengstrom4591 Рік тому +1

    HUGE help! Thank you for the information!

  • @PappyNet01
    @PappyNet01 4 роки тому +1

    Great job on the tutorial/demonstration of the K-Rain Hydrotek 4000. Thank you I know how you feel about not getting the answers that you need when you are researching for information that will assist in resolving a problem. I have the same Hydrotek 4000 Indexing Valve. Our irrigation system was installed more than 20 years ago during the previous two owner's period. I was trying to remove the cam [either a three zone cam (Part #6107043) or four zone cam (Part #6107044) for four outlet valve] earlier, but it most likely seized onto the four outlet valve body. I am still researching on how I can safely remove the cam and stem for maintenance and replacement. In my humble opinion the installers never closed off the unused valve outlet because they didn't install a six-(6) inch pvc pipe and cap. I think I am stuck with the index rotation because the design of the irrigation system layout. I have to add additional gold pins (I call rotation pins) to have my front yard watered in the morning. Thanks

  • @legendcanibal9642
    @legendcanibal9642 3 роки тому

    Question.. can you turn it on.. manually...?
    Pues comenzar la valvula manualmente...?
    No timer...Thxz

  • @oabus
    @oabus 3 роки тому +1

    great job. good tutorial

  • @jackfntwist
    @jackfntwist 2 роки тому

    In my house the 2 outlets that are not in use do not have the pvc pipes closed like yours. That might be problem.

    • @handymanrepair8955
      @handymanrepair8955  2 роки тому

      Well if you don’t need the 2 pipes, just cut it and put a caps on it.. then you will have just the sections that you need to work

    • @Landy2525
      @Landy2525 2 роки тому

      @@handymanrepair8955 how do you know which pipes go where? I need to close two pipes but I have no idea which one of the four it is.

    • @raytown04
      @raytown04 Рік тому +1

      @@Landy2525 you can run your pump and when there is no zone that turns on, stop the pump and take off the cam carefully. The white stem will be pointing toward the zone that was just activated which will be the one you need to cap since no sprinklers turned on.

  • @yovinkoperez3529
    @yovinkoperez3529 3 роки тому +1

    una pregunta, y quetal si quiero poner uno de 6 zona?

    • @handymanrepair8955
      @handymanrepair8955  3 роки тому

      Si claro puedes comprar este producto
      www.ebay.com/itm/K-Rain-4000-SERIES-CAMMED-FOR-6-OUTLET-For-Indexing-Valves-5-Zone-Or-6-Zone-/264373346210?_trksid=p2349624.m46890.l49286

    • @handymanrepair8955
      @handymanrepair8955  3 роки тому

      Aqui esta este producto para ello
      www.ebay.com/itm/K-Rain-4000-SERIES-CAMMED-FOR-6-OUTLET-For-Indexing-Valves-5-Zone-Or-6-Zone-/264373346210?_trksid=p2349624.m46890.l49286

    • @yovinkoperez3529
      @yovinkoperez3529 3 роки тому

      y solo tengo que comprar la tapa de 6 y ponerlo y ya con eso ya queda?

    • @yovinkoperez3529
      @yovinkoperez3529 3 роки тому +1

      por cierto ya m3 suscribió en su canal.

    • @handymanrepair8955
      @handymanrepair8955  3 роки тому

      @@yovinkoperez3529 gracias!!!! Muy agradecido

  • @enriquealtunacastillo2462
    @enriquealtunacastillo2462 3 роки тому +1

    Can you share the link to the part?

  • @handymanrepair8955
    @handymanrepair8955  3 роки тому

    K-RAIN 4404 4000 Series Indexing Valve with 4 Outlets and 4 Zones www.amazon.com/dp/B00WEFST0M/ref=cm_sw_r_cp_api_glt_fabc_KQEY97KJVHGE43D6Q3GZ?_encoding=UTF8&psc=1

  • @handymanrepair8955
    @handymanrepair8955  3 роки тому

    Here is the 2 zones Cam
    www.krain.com/4000-5000-2-zone-cam-p6107042

  • @-mejor-que-nostradamus-6152
    @-mejor-que-nostradamus-6152 2 роки тому

    Little Puppy Buy The Other Brand
    Has Inside Accessories To Convert 1, 2, or 3 In a 4 Zones
    Wasting Your Time, People Who Know About Irrigation
    Know You Did a Wrong Job.
    Amén.