Modal Testing Seminar

Поділитися
Вставка
  • Опубліковано 5 сер 2024
  • More information on modal testing in the links of this page from the Simcenter Testing community: community.sw.siemens.com/s/ar...
  • Наука та технологія

КОМЕНТАРІ • 9

  • @SnehaRupa1
    @SnehaRupa1 2 роки тому +1

    Engaging Webinar! Great insights on the basics. I have been using Simcenter Testlab to study the modal testing on a gearbox. Honestly the Siemens resources and the manual helped a lot in the learning process. And I happened to stumble upon this seminar after all the hands-on learning. It all makes sense now! Every step is a new learning :)

  • @karthiks2845
    @karthiks2845 2 роки тому

    Thank you very much for quality contents .. it throws light in my knowledge..

  • @BasitKhan-te4ls
    @BasitKhan-te4ls 17 днів тому

    I want to find the damping ratio of a helical spring using this method:
    1. Attach an accelerometer at the top of the spring.
    2. Disturb the spring by hand to generate a time vs. frequency graph.
    3. Convert this time vs. frequency graph to an FFT to see the frequency vs. amplitude graph.
    4. Find the damping ratio using the half-bandwidth method on the FFT.
    My questions are:
    a. Is this the right method to find the damping ratio, or is the FRF necessary to include the force with hammer impact?
    b. What if I use or don't use an impact hammer as in this video?

  • @ThePopsers
    @ThePopsers Рік тому +1

    The audio cuts out a few times at around 1:05:30, then comes back

  • @jjxie3291
    @jjxie3291 2 роки тому

    Hello, can you tell me if I want to have two MIF reference points at the 72min of the video? Do i have to have two acceleration sensors for fixed test in the test? If there is only one acceleration sensor, then there can only be one MIF reference. Is this the understanding? Thank you and look forward to your reply

    • @SimcenterTesting
      @SimcenterTesting  2 роки тому +1

      Two fixed force inputs are needed for two MIF functions. If there is one force reference input, there is only one MIF.

    • @jjxie3291
      @jjxie3291 2 роки тому

      @@SimcenterTesting thanks

  • @user-lu5fr1dw6j
    @user-lu5fr1dw6j Рік тому

    Would this software be capable of analyzing the modes of a fluid body using wave gauge/pressure sensor data that captures oscillations of the free surface?

    • @SimcenterTesting
      @SimcenterTesting  Рік тому

      Data for the modal analysis does not have to be acceleration as shown in this video. Data can be any type (pressure, velocity, etc), and assuming there is modal behavior captured in the waveforms, the software can be used to analyze it and find the modes.