  • @fabrizioruffa7705
    @fabrizioruffa7705 3 роки тому +6

    The conclusion is : activate with what you want,but activate your irrigants,.

  • @endodontiasemfronteira
    @endodontiasemfronteira Рік тому +1

    Whats open system e closed, irrigation?

  • @pascalisadhikurniawan3192
    @pascalisadhikurniawan3192 3 роки тому +1

    do you think there are bubbles when using vdw eddy? for how many minutes is recomend to use eddy?

    • @artem_kurov
      @artem_kurov  3 роки тому

      There is cavitation. And some amount of air is taken from outside.
      There are different recommendations about time, but overall solution exposure time is more important than activation itself. I expose till solution no longer gets turbid.

    • @pascalisadhikurniawan3192
      @pascalisadhikurniawan3192 3 роки тому

      @@artem_kurov ah i see the point is until the solution no longer turbid. Thankyou doc

  • @babacanoflaz1403
    @babacanoflaz1403 2 роки тому

    May I ask what is the difference between open and closed systems

    • @artem_kurov
      @artem_kurov  2 роки тому +1

      I did answer this question in the comments below

  • @abdulkarimsalem3611
    @abdulkarimsalem3611 5 років тому +2

    Would you mind mention the conclusion?

    • @artem_kurov
      @artem_kurov  5 років тому +4

      Everybody can make their own conclusions. I provide experimental data only.

  • @mohammadkhalil3265
    @mohammadkhalil3265 4 роки тому +1

    Impressive, what’s kind of air scaler used with eddy & value of chair bar?

    • @artem_kurov
      @artem_kurov  4 роки тому +1

      Russian air scaler НУЗК-4-02, 6000 Hz. What is chair bar?

  • @kapodav9770
    @kapodav9770 6 років тому

    Едди не слишком агрессивный ?в плане выведения за верхушку при открытых системах?
    А этанол чистый был добавлен?

    • @artem_kurov
      @artem_kurov  6 років тому +1

      Если не выходить активатором за верхушку - ничего не выводит. Если корень не торчит в пазуху, то считайте это закрытой системой. ничего он в закрытую систему не выводит.
      Был добавлен 96% этанол.

    • @areebasad7849
      @areebasad7849 4 роки тому

      Hey friends, would you recommend some book in endodontics which are followed in Russia🇷🇺

  • @salihkubba4017
    @salihkubba4017 5 років тому +2

    What do you mean by open system and closed one

    • @artem_kurov
      @artem_kurov  5 років тому +10

      Commonly used term "open system" means root canal is connected to another volume. It can be divergenting and apically connected canals, like mb1 and mb2, some kind of isthmus, a drained cyst or a maxillary sinus.
      Open system means that liquid can go free and through.
      Closed systems are normal single canals with firm periodontal tissue. The liquid can only go backwards to the orifice.

    • @salihkubba4017
      @salihkubba4017 5 років тому +1

      Артем Куров
      Ahh now i understand
      Thanks for answering dear doc
      One more question
      İf i have a straight canal and another curved one
      İ need a size of 30.4 or 35.4 so i can be sure the irrigation reaches the apex with agitation?
      Or i can do 25.4 for both or each one a different approach ?
      From your expierence and thank you again dear doc

    • @artem_kurov
      @artem_kurov  5 років тому +3

      @@salihkubba4017 First of all, your irrigation needle diameter is 0,29 mm. You need to reach the working length with a needle, so 30.04 is needed.
      Natrium hypochlorite 5% has a high surface tension, so it will not go in any canal below 30 without agitation. Because of surface tension, air bubbles can block the canal even with agitation.
      But you can use solutions with lower surface tension, like Hypoclean, in smaller canals.
      That is not my experience, it's research based info.

    • @salihkubba4017
      @salihkubba4017 5 років тому +3

      Артем Куров ok i see
      Thanks for the informative data my friend
      As in russian cpaceba daragoy

    • @mikecheng6959
      @mikecheng6959 4 роки тому

      @@artem_kurov Hi sir, could you share the link for the research literature?

  • @bestporridge
    @bestporridge 5 років тому

    Where u get the training blocks with lateral canals? And what blue dye you using?

    • @artem_kurov
      @artem_kurov  5 років тому +2

      I drill lateral canal with a sharpened K-file. As you can see, only the third attempt was effective. Oil lubrication required.
      I use cheap inkjet printer dye. It was a chiose of three. The cheaper is dye, the faster it decolorates with hypochlorite.

  • @easyshop5510
    @easyshop5510 5 років тому +1

    Is Lazer cleaning better option?

    • @artem_kurov
      @artem_kurov  5 років тому

      You can find comparison with Er YAG laser here on UA-cam. It is comparable in small systems. But you need Erbium laser. Other lasers do nothing.

  • @АннаНикишина-я5ж
    @АннаНикишина-я5ж 4 роки тому

    Подскажите,плз, что за насадка( типоразмер) у эндоактиватора такого насыщенного зеленого цвета?

    • @artem_kurov
      @artem_kurov  4 роки тому

      Лысый roeko canal brush на waterpik flosser

    • @АннаНикишина-я5ж
      @АннаНикишина-я5ж 4 роки тому

      Артем Куров то есть это не девайс Дентсплая?

    • @artem_kurov
      @artem_kurov  4 роки тому

      @@АннаНикишина-я5ж нет

  • @wolfhorsky
    @wolfhorsky 6 років тому +2

    Sorry mate, but it apears that You ultrasonic file isn't vibrating properly. Poor results.

    • @artem_kurov
      @artem_kurov  5 років тому +1

      Lowest power, Endo mode. If increase power, it vibrates much more, but it becomes very aggressive to the walls and curvatures.

    • @wolfhorsky
      @wolfhorsky 4 роки тому +2

      @@artem_kurov Sorry for the late answer. Try to use Stainless Steel Spreaders ISO 35 or 40 and bend them. Set the power on 30% (period or general). You can take off the plastic handle by heating one the flame. I guarantee You will have much different results. I made few vids for my lectures and my PUI looks way different. Cheers and keep safe.

  • @Friedel009
    @Friedel009 4 роки тому

    Ethanol 96% + cheap blue ink in the last experiment is hardly relevant to clinical reality as we're not dealing with ink, but organic debris

    • @artem_kurov
      @artem_kurov  4 роки тому +1

      The main difference is exposition. It takes seconds to oxidize ink dye, but about 20 minutes to remove organic tissues