There is cavitation. And some amount of air is taken from outside. There are different recommendations about time, but overall solution exposure time is more important than activation itself. I expose till solution no longer gets turbid.
Если не выходить активатором за верхушку - ничего не выводит. Если корень не торчит в пазуху, то считайте это закрытой системой. ничего он в закрытую систему не выводит. Был добавлен 96% этанол.
Commonly used term "open system" means root canal is connected to another volume. It can be divergenting and apically connected canals, like mb1 and mb2, some kind of isthmus, a drained cyst or a maxillary sinus. Open system means that liquid can go free and through. Closed systems are normal single canals with firm periodontal tissue. The liquid can only go backwards to the orifice.
Артем Куров Ahh now i understand Thanks for answering dear doc One more question İf i have a straight canal and another curved one İ need a size of 30.4 or 35.4 so i can be sure the irrigation reaches the apex with agitation? Or i can do 25.4 for both or each one a different approach ? From your expierence and thank you again dear doc
@@salihkubba4017 First of all, your irrigation needle diameter is 0,29 mm. You need to reach the working length with a needle, so 30.04 is needed. Natrium hypochlorite 5% has a high surface tension, so it will not go in any canal below 30 without agitation. Because of surface tension, air bubbles can block the canal even with agitation. But you can use solutions with lower surface tension, like Hypoclean, in smaller canals. That is not my experience, it's research based info.
I drill lateral canal with a sharpened K-file. As you can see, only the third attempt was effective. Oil lubrication required. I use cheap inkjet printer dye. It was a chiose of three. The cheaper is dye, the faster it decolorates with hypochlorite.
@@artem_kurov Sorry for the late answer. Try to use Stainless Steel Spreaders ISO 35 or 40 and bend them. Set the power on 30% (period or general). You can take off the plastic handle by heating one the flame. I guarantee You will have much different results. I made few vids for my lectures and my PUI looks way different. Cheers and keep safe.
The conclusion is : activate with what you want,but activate your irrigants,.
Whats open system e closed, irrigation?
do you think there are bubbles when using vdw eddy? for how many minutes is recomend to use eddy?
There is cavitation. And some amount of air is taken from outside.
There are different recommendations about time, but overall solution exposure time is more important than activation itself. I expose till solution no longer gets turbid.
@@artem_kurov ah i see the point is until the solution no longer turbid. Thankyou doc
May I ask what is the difference between open and closed systems
I did answer this question in the comments below
Would you mind mention the conclusion?
Everybody can make their own conclusions. I provide experimental data only.
Impressive, what’s kind of air scaler used with eddy & value of chair bar?
Russian air scaler НУЗК-4-02, 6000 Hz. What is chair bar?
Едди не слишком агрессивный ?в плане выведения за верхушку при открытых системах?
А этанол чистый был добавлен?
Если не выходить активатором за верхушку - ничего не выводит. Если корень не торчит в пазуху, то считайте это закрытой системой. ничего он в закрытую систему не выводит.
Был добавлен 96% этанол.
Hey friends, would you recommend some book in endodontics which are followed in Russia🇷🇺
What do you mean by open system and closed one
Commonly used term "open system" means root canal is connected to another volume. It can be divergenting and apically connected canals, like mb1 and mb2, some kind of isthmus, a drained cyst or a maxillary sinus.
Open system means that liquid can go free and through.
Closed systems are normal single canals with firm periodontal tissue. The liquid can only go backwards to the orifice.
Артем Куров
Ahh now i understand
Thanks for answering dear doc
One more question
İf i have a straight canal and another curved one
İ need a size of 30.4 or 35.4 so i can be sure the irrigation reaches the apex with agitation?
Or i can do 25.4 for both or each one a different approach ?
From your expierence and thank you again dear doc
@@salihkubba4017 First of all, your irrigation needle diameter is 0,29 mm. You need to reach the working length with a needle, so 30.04 is needed.
Natrium hypochlorite 5% has a high surface tension, so it will not go in any canal below 30 without agitation. Because of surface tension, air bubbles can block the canal even with agitation.
But you can use solutions with lower surface tension, like Hypoclean, in smaller canals.
That is not my experience, it's research based info.
Артем Куров ok i see
Thanks for the informative data my friend
As in russian cpaceba daragoy
@@artem_kurov Hi sir, could you share the link for the research literature?
Where u get the training blocks with lateral canals? And what blue dye you using?
I drill lateral canal with a sharpened K-file. As you can see, only the third attempt was effective. Oil lubrication required.
I use cheap inkjet printer dye. It was a chiose of three. The cheaper is dye, the faster it decolorates with hypochlorite.
Is Lazer cleaning better option?
You can find comparison with Er YAG laser here on UA-cam. It is comparable in small systems. But you need Erbium laser. Other lasers do nothing.
Подскажите,плз, что за насадка( типоразмер) у эндоактиватора такого насыщенного зеленого цвета?
Лысый roeko canal brush на waterpik flosser
Артем Куров то есть это не девайс Дентсплая?
@@АннаНикишина-я5ж нет
Sorry mate, but it apears that You ultrasonic file isn't vibrating properly. Poor results.
Lowest power, Endo mode. If increase power, it vibrates much more, but it becomes very aggressive to the walls and curvatures.
@@artem_kurov Sorry for the late answer. Try to use Stainless Steel Spreaders ISO 35 or 40 and bend them. Set the power on 30% (period or general). You can take off the plastic handle by heating one the flame. I guarantee You will have much different results. I made few vids for my lectures and my PUI looks way different. Cheers and keep safe.
Ethanol 96% + cheap blue ink in the last experiment is hardly relevant to clinical reality as we're not dealing with ink, but organic debris
The main difference is exposition. It takes seconds to oxidize ink dye, but about 20 minutes to remove organic tissues