How to Solve Electric shock problem in Home appliances | Current Leakage reason & solution [Hindi]

Поділитися
Вставка
  • Опубліковано 8 лют 2025
  • Electrocution in Home Gadgets can cause serious injuries. Today I shall explain all reasons why we get shocked when touching home appliance, as well as how to solve it.
    🛍 💳[Buying Affiliate Links]💳 🛍
    Fridge-
    LG 547L 3 Star GN-H702HLHQ amzn.to/3oRtr9V
    LG 547L 2 Star GN-C702SGGU amzn.to/3Bn3mEu
    Multimeter-
    Mastech MS2101 (My meter) amzn.to/30miXTH
    Sigma amzn.to/2G2gd75
    Meco amzn.to/3jgVF98
    Neon Tester amzn.to/3CYXSmq
    Digital Tester amzn.to/3CVDiDp
    Earth tester amzn.to/3Df3skP
    3 Pin modular socket amzn.to/3QfrTkD
    ♦️ [Important Related Videos] ♦️
    LG 547L Fridge Review
    English- • [Eng] Best Giant Fridg...
    Hindi- • [Hindi] Big Fridge for...
    How to Test earthing using Digital multimeter-
    • How to Check EARTHING ...
    #handymanstoolbox #ZenInnovations #ZenHindi #Zen_Fridge_Guide #LG #LGFridge #InverterFridge #SmartFridge
    My Equipment-
    Ring Light amzn.to/3cL0ohN
    Mobile Phone amzn.to/3FKlxoH
    Mic amzn.to/3COXIdl
    Tripod amzn.to/3xo85UH
    Laptop amzn.to/3CTrq0Z
    Green Screen amzn.to/3l9PhU1
    💎 [Playlists] 💎
    Members-Only Videos-
    • Members-only videos
    Handyman's Toolbox-
    • Handyman's Toolbox
    💫 [Links & Credits] 💫
    pixabay.com/
    🌐 [My Social Media] 🌐
    Join this channel to get access to perks:
    / @zeninnovations
    📲Join Telegram Group!📲
    • Zen Innovations is now...
    💟 Do visit my Other Awesome Channels 💟
    Zen Games
    / @zen-games
    Zen Gadgets
    www.youtube.co...
    Zen Home
    / @zenhomeappliances
    💚Awesome DIYs on Instructables💚
    www.instructab...
    🛑 Disclaimer 🛑
    Any Experiments, Tricks, Tips, DIYs and Procedures shown in this video shall be tried solely at your own Risk. Zen Innovations, Its owners or Partners will not be responsible for any Kind of Harm, Injury,Death, Broken Equipment, Lost Data, any Other losses etc arising out of application of above video.
    🛑 Affiliate Links Disclosure & Disclaimer 🛑
    This Post, Description or comment box of this video might contain Affiliate Links. Which Means that, at No additional cost to you, If you use these links to Buy Products, we earn a small commission. The Generated Revenue Helps to keep this channel running.
    🛑 Copyright Disclaimer 🛑
    Under Section 107 of the Copyright Act 1976, allowance is made for "fair use" for purposes such as criticism, commenting, news reporting, teaching, scholarship, and research. Fair use is a use permitted by copyright statute that might otherwise be infringing. Non-profit, educational or personal use tips the balance in favor of fair use.
    🛑 Amazon Disclaimer 🛑
    Amazon and the Amazon logo are trademarks of Amazon.com, Inc. or its affiliates

КОМЕНТАРІ • 66

  • @ZenInnovations
    @ZenInnovations  2 роки тому +2

    🛍 💳[Buying Affiliate Links]💳 🛍
    Fridge-
    LG 547L 3 Star GN-H702HLHQ amzn.to/3oRtr9V
    LG 547L 2 Star GN-C702SGGU amzn.to/3Bn3mEu
    Multimeter-
    Mastech MS2101 (My meter) amzn.to/30miXTH
    Sigma amzn.to/2G2gd75
    Meco amzn.to/3jgVF98
    Neon Tester amzn.to/3CYXSmq
    Digital Tester amzn.to/3CVDiDp
    Earth tester amzn.to/3Df3skP
    3 Pin modular socket amzn.to/3QfrTkD
    ♦ [Important Related Videos] ♦
    LG 547L Fridge Review
    English- ua-cam.com/video/Y1FE1KJY7rc/v-deo.html
    Hindi- ua-cam.com/video/ueDwTh1aZXM/v-deo.html
    How to Test earthing using Digital multimeter-
    ua-cam.com/video/fKm-RTZSGtU/v-deo.html

  • @AshutoshKrSingh9211
    @AshutoshKrSingh9211 19 днів тому

    thanks for new learning

  • @jaikhatri6535
    @jaikhatri6535 3 місяці тому

    Thank you so much. Got to learn alot and solved my polarity problem.

  • @jeevansaijinne4863
    @jeevansaijinne4863 Рік тому +2

    Earthing with remove current but why is current coming to fridge body?
    I have an oven and i get shock when touched, earthing is not present in the switch board, is there any leakage in oven or do all appliances emit current?

    • @ZenInnovations
      @ZenInnovations  Рік тому

      Get proper earthing done. Might be a small leakage or body leak.

    • @AbhishivSaxena-e4z
      @AbhishivSaxena-e4z 11 місяців тому

      @@ZenInnovations I have a dishwasher which was giving shock because no earthing was present. Now fixed, but does it mean that the dishwasher has some fault? Should I contact the company? Thanks.

    • @ZenInnovations
      @ZenInnovations  11 місяців тому

      @@AbhishivSaxena-e4z you may contact.

  • @solotraveler1932
    @solotraveler1932 Рік тому

    Well explained 😊

  • @freejournals
    @freejournals 7 місяців тому +1

    *It happened sometimes due to body static discharge specially in dry weather, but earthing is most important for human safety and equipment too.*

  • @alkesh135
    @alkesh135 2 роки тому +1

    Just I checked at my home power supply from Grid. Which is below
    Phase - Neutral: 228 volt
    Phase - Earthing: 233 volt
    Neutral - Earthing : 6.9 volt
    As per above, My home Earthing is perfect, but Grid Neutral is not perfect. Please focus this matter or discuss on telegram

    • @srujanreddy6699
      @srujanreddy6699 2 роки тому +1

      You have to get it checked by electricity department at the transformer. Neutral is grounded at transformer, and if not properly grounded, you get this potential difference

  • @lobobaltazar1322
    @lobobaltazar1322 2 роки тому

    For crying out loud, please make videos in english. That way the whole world can understand you. Generally speaking you guys are best at explaining pretty much anything, world needs you :)

    • @ZenInnovations
      @ZenInnovations  2 роки тому +2

      Cool!
      I do have a bunch of videos in english but they get very poor views.

  • @onyxury101
    @onyxury101 Рік тому

    Thanks

  • @mitchrich6
    @mitchrich6 Рік тому

    Very informative

  • @jec_ecart
    @jec_ecart 2 роки тому

    Best information

  • @SujeetSingh-bq3bx
    @SujeetSingh-bq3bx 2 роки тому

    nice video!
    seems your fridge may be defective or house wiring is wrong
    in any appliance phase as well neutral must be isolated from the body metallic parts and the 3rd wire Earth must be connected to the metallic body parts
    looks like you have not installed RCCB

    • @ZenInnovations
      @ZenInnovations  2 роки тому

      I have solved it in this video. Live.

    • @SujeetSingh-bq3bx
      @SujeetSingh-bq3bx 2 роки тому

      @@ZenInnovations i believe the problem still exists
      Out of 2 wires ( phase & neutral) 1 wire is directly in contact with fridge body
      Earlier it was phase wire now its neutral wire
      Probably its neutral wire and earth wire are commonly connected
      Need to further investigate after taking out plug from socket

    • @ZenInnovations
      @ZenInnovations  2 роки тому +1

      Yes. I was expecting better insulation from LG. However, my LG washing machine on same socket did not have body leakage.
      Some machines bridge Neutral to earth using a Surge supressor or other component. this happens in laptops too.

  • @suryavishwanath8564
    @suryavishwanath8564 2 роки тому +2

    Sir, you didn't mention correctly , why there was leakage current in your fridge in the first place?? just because the polarity of the near by plug was the issue ?? if so, then pls explain why ?? because, earthing main purpose is to provide path for the leakage current to reach back to the ground itself. But if your poles were reversed also, earthing should have been working fine right?? then why still there was leakage in your fridge?? and also how did the leakage current was resolved?? explain fully sir

    • @ZenInnovations
      @ZenInnovations  2 роки тому +1

      Some devices will bridge the neutral & earth using an mov or other component, which causes these issues. It may not happen in all devices.
      I have already explained the solution.

    • @engrbilalahmedawan1315
      @engrbilalahmedawan1315 8 місяців тому

      @ZenInnovations what if swapping the L and N don't solve the problem, in my case here in Pakistan i swapped the phase and neutral but the body is still showing voltage through a tester on a Haier Refrigerator.

  • @VENOM_RRR
    @VENOM_RRR Рік тому

    Sir mera sabhi equipments me shock aata hai to agar main apna main wire ko apas me interchange kar du to isse Inverter me koi dikkat to nahi aayegi na

  • @VEEGEE_
    @VEEGEE_ 2 роки тому

    Sir ek Answer btao.. Inverter mein KVA rating hote hai like 1kva 3kva. Vo Inverter ke AC output ke Hote hai? ya Battery Discharge Rate ke Hote hai???
    (230v X 4.3A = 1kva OR 12v X 83A = 1kva) ??

    • @ZenInnovations
      @ZenInnovations  2 роки тому

      watch
      ua-cam.com/video/WoUb7DZiT4c/v-deo.html

    • @VEEGEE_
      @VEEGEE_ 2 роки тому

      @@ZenInnovations Mein dekh chuka hu sir Aapka boht saara videos.. par Just want to know KVA value is After Efficiency Factor or Before...

    • @ZenInnovations
      @ZenInnovations  2 роки тому

      @@VEEGEE_ kva is inflated marketing value.
      Real value is less (in watts)

    • @VEEGEE_
      @VEEGEE_ 2 роки тому

      @@ZenInnovations yes That is right.. thanks

  • @jacpaulgladson
    @jacpaulgladson 2 роки тому

    Sir, I have a doubt regarding Motorola 10.5 kg washing machine... What's the difference between 105FLIWBM5S and 105FLIWBM5DG models..? They two looks similar but price differs... Please guide me about it...

    • @ZenInnovations
      @ZenInnovations  2 роки тому

      G is grey, S is silver.
      Full guide here ua-cam.com/video/KfyqN-wr7mo/v-deo.html

  • @saurabhthakare1653
    @saurabhthakare1653 Рік тому

    Sir ...very minor current shows in cooler & wiring...what is the prbm sir in wiring...how can I solve this prbmm....

    • @ZenInnovations
      @ZenInnovations  Рік тому

      Check for any wire cut or body touch.

    • @Hafizabubakar873
      @Hafizabubakar873 10 місяців тому

      Sir.i have an inverter fridge which is showing current in the upper part of the fridge while picking anything?i've checked the wiring which is ok

  • @RaushanKumar-ew3fb
    @RaushanKumar-ew3fb Рік тому

    Sir
    Mana ki mera stand fan ke body me lekage current aa raha hai, to agar mai fan ke body ko earthing se connect kar de phir fan ke body ko tuch kare to kya hame shock lag sakta hai???

    • @ZenInnovations
      @ZenInnovations  Рік тому

      First get the windings checked.

    • @RaushanKumar-ew3fb
      @RaushanKumar-ew3fb Рік тому

      @@ZenInnovations
      Mana ki winding se hi current lekage ho raha hai.

    • @ZenInnovations
      @ZenInnovations  Рік тому

      @@RaushanKumar-ew3fb Earth lagane se bill jyada ayega.

  • @karanShergill1
    @karanShergill1 8 місяців тому

    Bhai mere fridge se current nhi lgta par jha usse paint utra hai what par bht dim tester chal rha hai or freezer par bhi

  • @kucchbhi10
    @kucchbhi10 Рік тому

    Oven , fridge aur washing machine mein bina Slipper ke current lag raha hai?

  • @k.z.9250
    @k.z.9250 7 місяців тому

    Great thanks

  • @arjunsingh-ei2qb
    @arjunsingh-ei2qb 2 роки тому

    Sir Mera pass LG ka 3star AC h vho AC shi sa cooling nhi kar rha na temperature maintain kar rha High cool par chalna ka baad nhi room temperature 33 rhta h please solution bata do sir.

  • @ghajinid005
    @ghajinid005 Рік тому

    Mera earthing thik hai sb. Fir bhi sbhi machine me current aata hai. Kya karan ho skte hai plz replay.

    • @ZenInnovations
      @ZenInnovations  Рік тому

      Pls check earthing like this ua-cam.com/video/fKm-RTZSGtU/v-deo.html

    • @ghajinid005
      @ghajinid005 Рік тому

      @@ZenInnovations ye sb kr liya hu sb ok hai fir bhi halka current rahta hai

    • @ZenInnovations
      @ZenInnovations  Рік тому

      Some other appliance is faulty. Disconnect all appliances and check.

  • @missionuluna5837
    @missionuluna5837 Рік тому +1

    Why at the end of the video you speak English? Demonstration Time u should speak English and tell us how you solve your problem.. Thanks for sharing

    • @ZenInnovations
      @ZenInnovations  Рік тому +2

      This is a hindi video as mentioned in the title.

  • @harishbajiya8709
    @harishbajiya8709 Рік тому

    Sir compressor on krne k baad testor current batata h ...

  • @kucchbhi10
    @kucchbhi10 Рік тому

    Bina chappal ke current lag raha hai kya karun?

  • @alkesh135
    @alkesh135 2 роки тому

    Please Don't use electrical tools without Insulation. Your Tester not for safety precaution.

  • @DipanjanDas23
    @DipanjanDas23 Рік тому

    Just coz of newbie linemen my entire home got fried due to surge current

  • @Dipak_7892
    @Dipak_7892 Рік тому

    D