How to Engineer Wood Diaphragms | Sheathing | Nailing | FULL EXAMPLE

Поділитися
Вставка
  • Опубліковано 5 лют 2025
  • Part 2 of our FULL BUILDING design example. We tackle the design and engineering of the wood diaphragm, including sheathing, nailing type and spacing. This is a full wood design example under seismic design criteria.
    Imagine what 5000 engineers can accomplish collectively... lets find out together.
    👇 SUBSCRIBE TO KESTÄVÄ ENGINEERING’S UA-cam CHANNEL 👇
    / @kestava_engineering
    For business inquiries email: kestavallc@gmail.com
    Connect with me on LinkedIn 👇
    / richard-racz-pe-620b1792
    Brave Browser 👇
    brave.com/
    (I am not affiliated or receive compensation from Brave)
    Music I Use 👇
    www.epidemicso...
    .
    .
    .
    .
    .
    .
    .
    .
    .
    Disclaimers: Richard Racz, P.E. does not hold the title "structural engineer". Any claim of it in the videos or descriptions is unintentional and is superseded by the title "civil engineer" in the states of MA and OR.
    The Kestävä UA-cam page is intended for informational purposes only. Nothing contained in, or provided through, this UA-cam page is intended to constitute advice, or to serve as a substitute for the advice of an engineering professional. Any reliance you place on such information is strictly at your own risk.
    Under no circumstances will Kestävä be responsible or liable in any way for any content, including but not limited to, any errors or omissions in the content, or for any loss or damage of any kind incurred as a result of any content communicated on this UA-cam page.
    #wooddesign #structuralengineering #kestavaengineering

КОМЕНТАРІ • 25

  • @Kestava_Engineering
    @Kestava_Engineering  3 роки тому +2

    We don't cover chord forces yet!

  • @stevenauyeung1410
    @stevenauyeung1410 3 роки тому +5

    stuff they dont teach you in school, bless you

  • @wchdb4476
    @wchdb4476 Місяць тому

    Our structural engineer hand writes all of the equations and the structural details (sections) and floor plan are all hand drawn. The only thing that is typed is the structural notes.
    It's nice to have a peek behind the curtain.
    Thanks.

  • @sugv10
    @sugv10 2 роки тому +3

    Hello! where is the part 1? please

  • @Benata
    @Benata 3 роки тому +2

    Been looking into plates and reading timoshenko and that famous monogram. What is your opinion? Rourke timoshenko monograms or fem analysis of shells.

  • @stevielloyd9687
    @stevielloyd9687 2 роки тому

    Hi, I'm loving your videos, super helpful! Maybe I am interpreting something incorrectly, but at 2:35 you say our W=256' and our L=120', but then you do the aspect ratio calculation (a=L/W), you do a=256'/120' which would be W/L according to how you defined your variables. I'm brand new to this so I want to make sure I'm understanding it correctly!

    • @Kestava_Engineering
      @Kestava_Engineering  2 роки тому

      its always W/L in the direction your looking at. so if you have a rectangle, then in one direction your aspect ratio will be high and in the other direction your aspect ratio will be very low. think about if the diaphragm was a piece of soft foam and your trying to bend the foam. the direction that is harder to bend has the lower aspect ratio because its stiffer.

  • @alit250
    @alit250 2 роки тому +2

    Hey Richard, awesome video! I needed this while designing a diaphragm and shear wall. I didn't quite understand how you came up with the 48 ft "zone A" regions. I didn't get where the 48 ft number came from. Cheers

    • @Kestava_Engineering
      @Kestava_Engineering  2 роки тому +3

      you can break up your diaphragms into sections when you have a large enough diaphragm. as you get closer to vertical lateral elements (shear walls braced frames etc) your shear demand in the diaphragm increases, but the opposite is true as you get to the mid point of the diaphragm between vertical lateral elements. so at a point you can call out a lighter diaphragm to save on nailing and potentially sheathing thickness. take a look at your shear diagram to help you determine where you can create another "zone" cheers!

  • @ehabaltimimi660
    @ehabaltimimi660 3 роки тому

    Even I passed the exam, but I am still like your examples, good job my friend.

  • @migueldlima4005
    @migueldlima4005 4 місяці тому

    Do you have any wood shearwall design for wind requirements, also do you offer more classes or content?

  • @draketaxon3982
    @draketaxon3982 2 місяці тому

    How does this method apply to a sloped roof diaphragm? I have had a difficult time finding any information on how to transform loads/capacities into a sloped wood diaphragm design. Is it possible to point me to a refernece that you use or create a video for this?

  • @SouthBayEngr
    @SouthBayEngr 2 роки тому +2

    What’s the title of the Part 1 video?

  • @jin9724
    @jin9724 3 роки тому

    Hello, I just wonder where is part 1 of this example that you are referring to in this vid? Thank you!
    [Update] Nvm. I found it. Thank you for what you do and this is really great vids. Thanks!

    • @Kestava_Engineering
      @Kestava_Engineering  3 роки тому

      thanks for tuning in Jin and im glad you found it!

    • @sugv10
      @sugv10 2 роки тому

      Hi, where is part 1? i can't find it

    • @mpokharel2010
      @mpokharel2010 Рік тому

      @@sugv10 ua-cam.com/video/3cddppsFMa0/v-deo.html

  • @SouthBayEngr
    @SouthBayEngr Рік тому

    You said 256’ is the width. Isn’t that the length? And 120 is the width?

    • @SouthBayEngr
      @SouthBayEngr Рік тому

      Also, what actually dictates which side is the length and which is the width? The NDS shows that the length is perpendicular to the lateral force.

    • @Kestava_Engineering
      @Kestava_Engineering  Рік тому

      in short - the length and width swap with each other depending on the direction you are applying load!

  • @KIM-r6d6s
    @KIM-r6d6s Рік тому

    Where's the part one?

  • @samuelthedude
    @samuelthedude 11 місяців тому

    I want to see pictures of the assemblies so bad