Cleaning cooling ducts | Removing limescale and rust | Plastic injection moulds
Вставка
- Опубліковано 4 жов 2024
- Cooling ducts of plastic injection moulds are cleaned with the RWR 80 L KST FULLY AUTOMATIC PLC cleaning system. Limescale and rust deposits, which among other things cause longer cooling times, are removed. Learn more about the cleaning system: bit.ly/3sFgjn7
Limescale and rust reduce the thermal conductivity of the plastic injection moulds, which increases the defect rate of the manufactured plastic parts and the amount of machining required.
The RWR 80 L KST FULLY AUTOMATIC PLC cleans internal circulation systems without disassembly and removes these deposits.
Step 1: Clean cooling ducts with Power Cleaner KST 2.0 (100 %) at 60 °C
Step 2: Flush cooling ducts with a 3 % corrosion protection/water mixture
Details:
Automatic cleaning with PLC
Adjustable processing temperature
Integrated flushing device for corrosion protection
Flow measurement of the ducts
Noise level reduction due to overall cladding
✔ Efficient and economical: the cleaner is recirculated.
Recommended cleaner: Power Cleaner KST 2.0 (bit.ly/3npnHSV)
Many thanks to Rudolf Held GmbH & Co. KG for allowing us to shoot the video scenes on their premises!
📧 E-Mail: service@bio-circle.de
☎️ Telefon: 05241 94430
🌎Website: www.bio-circle...
⏩ UA-cam: / biocircle
📷 Instagram: / biocircle_de
#CoolingCircuitCleaning
#CleaningSystem