DG synchronization control wiring. Generator load sharing control wiring.

Поділитися
Вставка
  • Опубліковано 29 сер 2023
  • in this video we are describe about generator synchronization control panel wiring .
    =============================================================================
    user and wiring manual of Woodward gen3000:-
    drive.google.com/file/d/1tuA9...
    =============================================================================
    dg synchronization basic principles:-
    • DG synchronization sys...
    ==============================================================================
    related topic:-
    Dg synchronization wiring pdf
    Dg synchronization wiring diagram pdf
    Dg synchronization wiring diagram
    dg synchronization procedure pdf
    dg synchronization method
    dg synchronization relay
    dg synchronization panel working
    What is a Woodward controller?
    What is Woodward easYgen?
    What is the use of genset controller?
    Woodward easygen 3000 controller price
    Woodward easygen 3000 controller manual pdf
    Woodward easygen 3000 controller manual
    ==============================================================================
    thanks for watching
    pls like and subscribe also.
  • Наука та технологія

КОМЕНТАРІ • 19

  • @MalikIbrahim555
    @MalikIbrahim555 9 місяців тому

    for basic concept its good video but now move to some deatils wiring like DG EFC & AVR connections according to DG synchronization actual method with dse 8610 module please most needed video thanks

  • @pednykholer5371
    @pednykholer5371 Місяць тому

    is the neutral wire of generator connect all the time to the transformer?

  • @ANOOPKUMAR-ld9eq
    @ANOOPKUMAR-ld9eq 5 місяців тому

    Good

  • @anupprajapati2834
    @anupprajapati2834 9 місяців тому

    Nice sir

  • @user-yc8rs3qi7e
    @user-yc8rs3qi7e 4 місяці тому

    DG ka control circuit and Woodward cantrol circuit ka connection bataiye

  • @AudioWorkstation
    @AudioWorkstation 4 місяці тому

    Apke according MCB or GCB dono m se koi ek hi working (Close) main rahegi ek bar m
    To ye Mains k sath DG ka Power Synchronisation kese hua ye mujhe samajh ni aaya, ya to mene galat samajh liya hai plz mujhe thik kare 🙏🙏

  • @usamajadoon352
    @usamajadoon352 3 місяці тому

    We are facing one issue
    For example generator 2 running now we want to parallel it with generator 1
    We started generator 1 , on ideal its showing 59 hz frequency and voltage 415 volts , now when we are synchronizing generator 1 with running generator so as generators are parallel
    Generator 1 started to increase frequency and simultaneously generator 2 started to decrease frequency so is it problem with load sharing
    What causes it to happen
    Trouble shoot

  • @rajeshmohan7881
    @rajeshmohan7881 9 місяців тому

    Very good explanation.लेकिन यह बताएं कि जब लोड तीनों जेनसेट्स के लायक होगा तो क्या तीनों एक ही क्षण स्टार्ट होंगे। दूसरा कि यह सेस ही कैसे होगा कनेक्टेड लोड कितना है?

    • @Sudhirtechnical
      @Sudhirtechnical  9 місяців тому

      Can bus communication ki setting ka use kia jata hai jisse controller communicate karke start command dete hai. Controller mai parameters setting hai. Aap user manual dhyan se dekhein sab likha hai.

  • @shivajigaikwad2827
    @shivajigaikwad2827 9 місяців тому

    Sir,
    I want to know can we use DG set as given below.
    When the main grid ( MSEB power)failed our DG set come online automatically within one minute.....now when power came we need to take changeover and again power cut during changeover for a 3 sec or 1 minutes which shut all utility equipment again.
    Can we synch DG with MSEB when power is come and once get stable DG set will get automatically cut-off.
    My question is that, is MSEB allowe this in Maharashtra?
    Please give reply sir. thank you !

    • @Sudhirtechnical
      @Sudhirtechnical  9 місяців тому

      Very brilliant question.but , synchronisation controller control number of parameters of dg and decided to synchronized but grid is supply source it frequently voltage not control by us. This condition switching not possible.

  • @AnujKumar-ct3up
    @AnujKumar-ct3up 8 місяців тому

    Sir jb m apne 3 DG ko synchronisation m chlata hu to Circuit breaker ki micro logic realy k amperes automatically 2000-2500 chle jata even load bhut km hota is vja se circuit breaker trip ho jata .
    Jb generator ko manually individually chlata to amperes normal rhte h .
    Kya issue ho skta please help

    • @Sudhirtechnical
      @Sudhirtechnical  8 місяців тому

      Pls check micrologix amp setting its not measure properly. And check related parameters.

    • @AnujKumar-ct3up
      @AnujKumar-ct3up 8 місяців тому

      @@Sudhirtechnical but individual chlate time to thik hota h esa kyu .
      Kya kisi load ki vja se esa ho skta h

  • @rajeditz2
    @rajeditz2 6 місяців тому

    Acb hai bro

    • @Sudhirtechnical
      @Sudhirtechnical  6 місяців тому

      Mai user manual ko refer karke hi. Video banata hu.

  • @NEERAJSHARMA-nx8su
    @NEERAJSHARMA-nx8su 9 місяців тому

    भाई जब जानकारी पूरी न हो तब वीडियो न बनाया करे। समय बेकार करते है ऐसे वीडियो।

    • @Sudhirtechnical
      @Sudhirtechnical  9 місяців тому +4

      अगर आपको जानकारी है तो आप भी वीडियो बनाए ताकि लोगों का भला हो सके

  • @mukeshyaduvanshi962
    @mukeshyaduvanshi962 4 місяці тому

    Not knowledgeable