Thanks brother but untrained technician jin ko bohat shok hota hy bara mechanic banny ka Wo sab apni apni stories bnaty hain bohat informative video hy ak experienced technician k liye
Bhai split AC me back side try me block he tho kya split AC me pump down karke indoor niche utarna padega ki koi Idea hoto batana kyo ki barish ke mousam me jyada aatihe Pani indoor mese
Bhaiya Samsung 2 Ton AC ka Gas pura charge krne ke baad pressure kitna hota hai or back pressure kitna hota hai humko Gas Recharge karwana hai isliye Jankari chayie bhaiya ji
Bhai inverter AC me likej chek karneke liye dusre fridge ke compressor se pressure testing karskte he kya r32 vale sistem me mere Pas nitogan aveleble nahihe bad me vaccum pump se vaccum kar ke by Wight se gas charging tho koi blast tho Nahi Hoga
Bhai jo bnde company se aate hai chutiye type hote hai or kal dubara aayenge complain ki hai mene Or pahale 10 unit max leta tha or ab 15 unit jaa rhi hai
Sir plz help , ik penasonic ka inverter ac hai split 1.5ton .uska jo logo hota hai jis per gas ke wait ko mention keya hota hai wo Pani se kharab ho geya hai .ab main kaise gas charge Karu.plz aap bta sakte hai k penasonic 1.5 ton inverter ac mein kitne grams.gas charge karne.plz jaroor help kare Bai.
R22 hoga to ambinet temperature +32 add hoga,or r32/r410 hoga to ambinet temperature +82 add kar kay jitna hoga back pressure utna rakh na hoga upnay india mai
sir apne outdoor ko pump down kr k gas save kia. teek hai phir flare banaya . sirif piping or indoor ka vacume kia or alen key khol die aisa hi hai sir
Sir plz jaroor help kare kitne grams gas charge kar Sakta hoo. Sir Maine pehle gas charge ki thi us mein back preser ke hisab se .Lekin uska back preser Kabi bhut jayada ho jata hai Kabi bhut kam ho jata hai .sir us mein gas R32 hai. Maine vecam bhi pump se Kiya sahi se fir bhi uski cooling perfect nahi aayi thi .ab wo complent wapis aa gayi hai .plz help.
You are the best and honest ac technician youtuber for sure.
Thanks brother
but untrained technician jin ko bohat shok hota hy bara mechanic banny ka Wo sab apni apni stories bnaty hain bohat informative video hy ak experienced technician k liye
Bhai split AC me back side try me block he tho kya split AC me pump down karke indoor niche utarna padega ki koi Idea hoto batana kyo ki barish ke mousam me jyada aatihe Pani indoor mese
Sir ac off karke he top up bhi kar sakte
Bhaiya Samsung 2 Ton AC ka Gas pura charge krne ke baad pressure kitna hota hai or back pressure kitna hota hai humko Gas Recharge karwana hai isliye Jankari chayie bhaiya ji
Sir outdoor me compressor ko starting capacitor se tork kese lagate hai us par video banai ae please
Bro Jo agar ham vacuum kare Vinay kya Puri
gas charge kar de to kya unit per kuchh kharab asar hoga r32 ka
R32 Back pressure 150 hai mere Daikin 1.5 tan non inverter ac me
Kya karu nikal du gas thoda
Bhai inverter AC me likej chek karneke liye dusre fridge ke compressor se pressure testing karskte he kya r32 vale sistem me mere Pas nitogan aveleble nahihe bad me vaccum pump se vaccum kar ke by Wight se gas charging tho koi blast tho Nahi Hoga
Han use kr skte ho
Thanks for Ripley Bhai r22 me tho bahut gas charg Kiya aase lekin r32 vale sistem me far lagatatha thanks for clarification
Nahi karsakta ho,kiw kai r32 system mai poliester oil hota hai,us mai air abjorb jada kar ta hai, cooling nahi hoga system a
Kitna charge lgega 850 gm gas dalne ke liye
Non inverter ac hai 1.5 ton standing presur 250 hai running presur 50 hai cater pipe pe ice hai chock hai kya aur kaha
Love to have it in English seems like is explaining well
Liquid ko daalne se rokne k liye kya kare
Vacuum kasy Kia?
Bhaiya aap plz amp bata dijiye kitna normal rhata hai
Kyuki bo bnda 3.8 pr chhod gya tha
Hamari bhi same yahi unit hai
Starting me 7 8 jata hai uske bad 4 5 tk rahta hai
AC ka grill temperature check karaiye
Bhai jo bnde company se aate hai chutiye type hote hai or kal dubara aayenge complain ki hai mene
Or pahale 10 unit max leta tha or ab 15 unit jaa rhi hai
Or bhai pressure bhi 70 ke paas chhod gya tha
70 ya 170
Sir plz help , ik penasonic ka inverter ac hai split 1.5ton .uska jo logo hota hai jis per gas ke wait ko mention keya hota hai wo Pani se kharab ho geya hai .ab main kaise gas charge Karu.plz aap bta sakte hai k penasonic 1.5 ton inverter ac mein kitne grams.gas charge karne.plz jaroor help kare Bai.
Bhai 1kg Rakhna shath usme se 60% gas band me daalna fir 5 mint ac chlana uske baad psi dekh kr daal dena 110 ,120 psi backpraseces rakhna
R22 hoga to ambinet temperature +32 add hoga,or r32/r410 hoga to ambinet temperature +82 add kar kay jitna hoga back pressure utna rakh na hoga upnay india mai
Very helpful. Ab topup ki topi nahi pehna payega koi mechanic 🤣🤣
sir apne outdoor ko pump down kr k gas save kia. teek hai phir flare banaya . sirif piping or indoor ka vacume kia or alen key khol die aisa hi hai sir
Han
Sir daikin inverter ac me gas dlwane pr 20 ampier aa rha h hona kitna chaie
Nhi 20 nhi hoga
Bhai running capicator change karke dekho phirbhi agar high amire leri hai machine to compressor kharab hai
Sir '''nice job
Of m licvid dal sakte h
Han
To silender ulta karke karna hai ki nahi sir
Jb ac band kr ke gas dalo tb aap ulta kr ke dal skte ho lekin agar on kr ke dalo to sidha
Super video keep it posting more videos'
R410 ko top up kar skkate hai kiya.
Nhi kr skte ho bhai
Sir AC inverter ke bare me a to z riper ke bare me bathye...
I will try
R-32 agr single gas ha ya phr R-410 ke tra 2 refrigerant ko mila kr banya gya ha ?
R32 single hai
Singal hi hota hai
Sir me bhe campne me lagna chata hu or me surat se hu kyaa app bata sakte he surat me voltage service senter khape he sir plzzzzzz
Sir plz jaroor help kare kitne grams gas charge kar Sakta hoo. Sir Maine pehle gas charge ki thi us mein back preser ke hisab se .Lekin uska back preser Kabi bhut jayada ho jata hai Kabi bhut kam ho jata hai .sir us mein gas R32 hai. Maine vecam bhi pump se Kiya sahi se fir bhi uski cooling perfect nahi aayi thi .ab wo complent wapis aa gayi hai .plz help.
To bhai room ka door khol do or ac ko 16 me chalu kar ke 3 se 5 mint me compressor 100% RPM me chalega tb check kijiye ga
,32ko top up kar sakte h
Han
Sir aik problm arhi mry outdoor me.. help chye ap sy
Jii boliye
@@SMARTAIRCOOLSYSTEM mra outdoor awaz bht kr rha ha. Us me R32 gase he ha. Compressor bht shor kr rha
To ek bar technician se dekha lijiye
@@SMARTAIRCOOLSYSTEM apka whtsap ha me video krta ho snd
8409556473
Bhai aap kahan se ho
Jharkhand se
Ak unit hai Goodman ka uska ritan nahi aa raha hai kya karn ho sakta hai
Gas km ho skta hai sahi se vacuum nhi hua hoga
Kam se kam 5bar vacuum kiya hai lo eska indoor v taip hai
@@user-jb4qg7yu9 system mai Sayed leakeg tha,esiliya oil giya hai indoor sahisay flash karo
Very helpful video sir
Very very helpful
Bhai mujhe v apne saath le chalo kaam pe... ❤️ 💖.. main v sikh lunga sab kuch...
Chalo meri jaan
Kitna amp hona chahiye
Inverter ac ka fix nhi hai
Boos error fault pe bhi bana
Nice sir
Sir upne bola tha up lanky ko band kar kai vacuum kiya tha to oo kaisa hoyga akber bataiye ❤️🙏
Sirf indoor ka kiye the bhai
@@SMARTAIRCOOLSYSTEM Sir uska akto vedio baniya na sir ❤️🙏
Okay
Thank you bhai
Es ko vacuum Kia
Han
Missubish duct ac hai eska erro UH aa raha hai
Ham to roj karte top up 32
Good
Ok
😮
Vai,,,apka nombor do
8409556473