NAVIEN COMBI BOILER NCB- 180/210/240 E351/E352/E353 Error Code (EASY ) Fixed !!!!
YOU DON’T WANT TO MISS OUT ON THE NEXT VIDEO??? SUBSCRIBE! 👍👍 (
NEXT VIDEO I’M GOING TO DO FULL STEP BY STEP MAINTENANCE ON MY NAVIEN BOILER ( you must do it yearly for longevity of your boiler and proper performance) ! Stay TUNED ! 😎🤝
Did you just have your Navien unit( s) installed ? Or has it been a while ? Whatever the case might be , if your having issues with your unit(s) and you’re getting error codes E351 /52/53 ( All OF THEM has to do with one thing : Water Pressure Sensor) THEN YOU MUST WATCH THIS QUICK AND EASY FIX THAT YOU COULD DO YOURSELF !!! ( Especially if your “a beginner”).
Here’s a quick overview on what happened to my unit: I was having issues with hot water and heating for the past 3 days . I went down in the basement and my unit was not working and was giving me some Error codes : E351, E352 and E353. I looked at my unit user’s information on page 22 “understanding the error codes “I called and it had to do with water pressure . I called the technical support number ( listed on the same section and same pag . 22 ) , I told them I was getting that error code and they told me I needed to get a licensed plumber or works for a company in here for them to speak with ( they wouldn’t speak with me because I’m not a plumber but just a home owner) . For the past 3 days I kept resetting the unit ( by pressing the reset bottom on the front panel ) and the system kept working sometimes for half hour , one hour and sometimes up to 3 hours . But today the 4th day , it would start working at all ( hot water or heating ) . I contact several plumber and places to see if they could come down and help me with the issue I couldn’t get a hold of one . One company that does service on Navien boilers are and sends technicians out to fix stuff at peoples house told me it was $175 USD per hour and that they didn’t have any availability for this week ( I called Wednesday . Today is Thursday of the same week ) . Since that was an emergency ( no hot water or heating for the house ) I started looking for pluming and hearing supply local store , and I found ( South shore pluming and heating supply inc , Brockton MA ). I gave them the code they told me it was water pressure sensor . That gave me HOPE 😃 ( the User’s information Manual said the same thing so I went out and got it today . It costed me about $44 dollars with tax and o fixed the problem myself and same a lot of money that probably I would pay a licensed plumber otherwise.
Hope this will help you out . If you like this video please subscribe and hit a like ! 🤝👍👍
Let me know about any part you didn’t understand on the video ; leave your comment on the comment section bellow , and I’ll be happy to answer them!
Note: One important thing You MUST DO ( I did it ) but I forgot to mention it on the video 🤦🏽‍♂️ you must turn off the Gas nob ( that allows the gas to enter the unit ) underneath your unit every you’re going to work on your unit (s). Mine has a small blue nob ,and the nob will be parallel with the gas iron pipe on On position . To turn the gas off turn the nob sideways and I’ll will be in the perpendicular position to the iron gas pipe . 👍
Переглядів: 40 135

Відео

КОМЕНТАРІ

  • @DanielRossi-b8e
    @DanielRossi-b8e 11 місяців тому

    I have a boiler navien 240/130 the domestic water shoots at me through the relief valve, when I open the cold water inlet water, do you have any idea why this is happening?

  • @DanielRossi-b8e
    @DanielRossi-b8e 11 місяців тому

    I have a boiler navien 240/130 the domestic water shoots at me through the relief valve, when I open the cold water inlet water, do you have any idea why this is happening?

  • @jeffrandolf5673
    @jeffrandolf5673 Рік тому

    Theres only one other video addresing this & the guy does not know about the "Pump drain plug" & says "water will shoot out everywhere when you unscrew the sensor so beware!"

  • @jeffrandolf5673
    @jeffrandolf5673 Рік тому

    The "pump drain plug"? I assume is for domestic hot water side ONLY & not the boiler side? I'd assume the only pump required would be for the boiler side to circulate the heated boiler water as the domestic side wouldn't need a pump because the domestic side already has city water pressure or well water pressure which has it's own pump to supply pressure? *Edit. : Nevermind... the exterior mounted circulator pumps move the heated/hot boiler water throughout the house. Im over thinking it w/o looking at my unit in front of me...*

  • @jaimegrant2771
    @jaimegrant2771 Рік тому

    You're a lifesaver sir, thank you.

  • @philipwilkinson988
    @philipwilkinson988 2 роки тому

    Just had one of these installed.Thanks for making this ,great help.

  • @KwikPlumbing
    @KwikPlumbing 2 роки тому

    Good job getting it done. But just so everybody knows there were a few mistakes in the explanation and his Navien Combi is not piped correctly. There are actually two domestic water supplies to the unit one which can be piped directly into the units domestic inlet which is for the hot water heating and the other goes to the automatic water feed inlet which provides water fir the space heating. On the automatic water feed inlet you need a 9D backflow preventer before it goes into unit. This is so contaminated boiler water doesn't ever backup into domestic house water which is your drinking water and water you shower with. On his unit he has a automatic water feed and backflow combo before it goes into unit which is incorrect. There is already a automatic water feed built into unit you only need backflow on the line before it goes into unit. Basically he has a automatic water feed on the water line then another inside the unit. Many I stallers got this part wrong . Most are used to installing this on conventional boilers not knowing a electronic one is but in. So if the external one fails it will stop giving water to boiler for space heating.

  • @FreeFree-cu2wd
    @FreeFree-cu2wd 2 роки тому

    You did good job Thank you

  • @randylipman7760
    @randylipman7760 2 роки тому

    I have a Combi boiler that will not even turn on . I came back from a short trip and I can't even have it on. I had to add some water to the system when I came home , turned the unit and nothing no lights.

  • @richardtrotta5595
    @richardtrotta5595 2 роки тому

    This is great information. Instead of getting the run around from Navien and a plumber, and paying $200 plus.....I can now do this for the price of the part. Take note: When you go through a plumber, they add 25-40% to the price of the part. Learn and but your own parts.

    • @rabitu041290
      @rabitu041290 2 роки тому

      Right? Bureaucracy upon bureaucracy! I’m glad this info was helpful 🤜🏽🤛🏽🙏🏼and hopefully everything worked out well for you sir.

    • @jeffrandolf5673
      @jeffrandolf5673 Рік тому

      Not all of us plumbers. Some if us are honest & feel guilty about charging exorbitant prices. It's a non-money making trait.

    • @jeffrandolf5673
      @jeffrandolf5673 Рік тому

      We're plumbers & called Navian Support. They put us on hold, then said to down load an app to our phone, then hung up! I went to UA-cam & "VIOLA "! BOOM, here it is!😂 What did we do B4 the internet??

  • @markk9335
    @markk9335 2 роки тому

    Thank you for the video. Very helpful. Good job.

  • @gumaromoreno6773
    @gumaromoreno6773 3 роки тому

    Me salvaste amigo

  • @normagutierrez9954
    @normagutierrez9954 3 роки тому

    Thank you for the great explanation!

    • @rabitu041290
      @rabitu041290 3 роки тому

      You bet! 😎🤝❤️ ( I haven’t had any problem since 🙏🏼).

  • @normagutierrez9954
    @normagutierrez9954 3 роки тому

    Thank you for the great explanation!

  • @Aldoshein
    @Aldoshein 3 роки тому

    Thank u!

    • @rabitu041290
      @rabitu041290 2 роки тому

      👆🏽👍🏽 you’re welcome!

  • @brianamaldonado3433
    @brianamaldonado3433 3 роки тому

    What does just 10E mean ?

    • @rabitu041290
      @rabitu041290 3 роки тому

      Hey !!! What are you referring to exactly ? so I can help you .

    • @rabitu041290
      @rabitu041290 3 роки тому

      Oh I see ! You meant error code ! 10E usually has to do with combustion air supply . So , check your air vent(s) . Probably it’s not getting enough of fresh air. ( check your air filter(s); it might be clogged up and must be cleaned . Hope this helps you. If that was the case , come here and leave your feedback , so others can be helped also . Thanks 🙏🏼🤝

  • @robertdaly6209
    @robertdaly6209 3 роки тому

    Thanks for the hint. I've got the oil on the bottom of the tank issues and the main board is bad. It's under warranty but the service isn't. If I can fix it I will. but, I haven't been happy with this. I had an old boiler that all i had to do was change the thermocouple once a year and it ran forever. why i changed for the savings is beyond me. Thanks for your help. I'll keep this in mind for the next problem. another issue was the error code 109 "clean the input air filter". It's so sesitive that only a small grass clipping will cause it to go into error.

    • @rabitu041290
      @rabitu041290 3 роки тому

      Thank YOU Sir! Yes that part sucks unfortunately; ( the service not included on the warranty 🤦🏽‍♂️) . I haven’t had any other issues since /ever . Let’s keep eye 👁 on it 👍🤝☝🏼

  • @davidmconroy
    @davidmconroy 3 роки тому

    Well done so kind of you to take the time to do this video THUMBS UP

  • @gersonpereira2017
    @gersonpereira2017 3 роки тому

    That’s was very nice explanation thank you so much.

  • @helenlambos5335
    @helenlambos5335 3 роки тому

    Thanks for sharing .. I find this company very unhelpful.. they say to call the number and when you call they say to call a plumber .. and I constantly have problems with the unit .. whatever I’ve saved in efficiency I’ve paid in plumbing bills!!

    • @rabitu041290
      @rabitu041290 3 роки тому

      That’s true , Unfortunately ! When I called for the first time that’s exactly what they told me . I would have to hire a certified plumber first in order for them to go through the issue . They wouldn’t speak to me or give me any directions but through a plumber 🤦🏽‍♂️🤦🏽‍♂️ So I replaced the water pressure sensor and it’s working fine up to this day ! 😎

    • @HK-zx8pu
      @HK-zx8pu 3 роки тому

      Elvis Barbosa most the time these is caused buy bad quality of water, install a water softer and filtration and make sure you do a annually clean of the coils, specially for domestic hat water.

    • @richardtrotta5595
      @richardtrotta5595 2 роки тому

      So true. The last time a plumber came to replace a 3-way valve and motor, it cost me $850......Whatever I save in monthly heating bills, I paid now.

  • @bradcloss9289
    @bradcloss9289 4 роки тому

    What is the part number for the abnormal pressure sensor

    • @rabitu041290
      @rabitu041290 4 роки тому

      Brad Closs E351,E352,E353 those were the codes I was getting ( all of them has to do with water pressure sensor ) check your user’s manual for error codes !

    • @petem6291
      @petem6291 3 роки тому

      Thank you for tacking the time to make this video