Service Call 2014 Rheem Water Heater
Trouble shoot water heater not lighting -Pilot light wont stay on
Переглядів: 35

Відео

My Nipples don't look good !
Переглядів 19816 годин тому
A couple of service calls to end the week. Water Heater service calls GE 2009 and 2024 Rheem 30 Gallon
Return to the scene of the crime - and a new service call
Переглядів 19419 годин тому
Three service calls
Brutal - American Water Heater 2007 Service Call
Переглядів 50221 годину тому
Service Call for natural gas water heater Valve - burner assembly - thermocouple - Pilot Tube
Call For No Hot Water - 3 Service Calls
Переглядів 260День тому
Rheem and Bradford White Service Calls
No Hot Water - Bad News for the Owner!!!
Переглядів 16821 день тому
Service call no standing pilot light or spark - bad news for the owner
Service Call Rheem 2016
Переглядів 18128 днів тому
No Pilot Light Trouble shooting service and repair no hot water
My First Hybrid Water Heater ?
Переглядів 100Місяць тому
Used Rheem Hybris Water Heater Installation
Tankless Water Heater Swap
Переглядів 551Місяць тому
Replace a tankless water heater with natural gas water heater
Is this my worst service call ever?
Переглядів 545Місяць тому
Yet another Rheem 2019. Pilot Light won't stay lit. Diagnose and trouble shoot water heater. 2.5 hours condensed into 20 mins !
Rheem 40 Gallon Diagnose and Repair of Water Heater
Переглядів 89Місяць тому
I couldn't stop the overheating issue in the field so i'm working on it at home. Rheem 2014 -40 Gallon - Had to replace the water heater - diagnosing and repairing if possible this one.
Return To the flooded Rheem
Переглядів 79Місяць тому
Called back out to clean and replace parts on a multiple flooding of rheem water heater
Not starting - dripping water
Переглядів 87Місяць тому
Water heater service call - flooded dripping water
Service Call - Short And Sweet
Переглядів 1432 місяці тому
No pilot - No Status Light Reported
High Limit Switch Water Heater
Переглядів 1752 місяці тому
High Limit Switch Water Heater
Rheem 2024 Service Call
Переглядів 832 місяці тому
Rheem 2024 Service Call
2015 Rheem water heater Trouble shoot owners work
Переглядів 1452 місяці тому
2015 Rheem water heater Trouble shoot owners work
Low Thermopile Voltage - diagnoses
Переглядів 1882 місяці тому
Low Thermopile Voltage - diagnoses
No Hot Water - Thermopile Issues on a Rheem 2015
Переглядів 1792 місяці тому
No Hot Water - Thermopile Issues on a Rheem 2015
Non functioning Rheem 30 gallon water heater - No Hot Water
Переглядів 2013 місяці тому
Non functioning Rheem 30 gallon water heater - No Hot Water
Circuit Board replacement with Reset procedure
Переглядів 3373 місяці тому
Circuit Board replacement with Reset procedure
Water heater finally needed replacing !
Переглядів 1193 місяці тому
Water heater finally needed replacing !
Dishwasher Whirlpool - Not spraying Water
Переглядів 1,7 тис.3 місяці тому
Dishwasher Whirlpool - Not spraying Water
No hot water in the morning - Blinking red light
Переглядів 2013 місяці тому
No hot water in the morning - Blinking red light
La Jolla CA , service call - water heater won't light
Переглядів 1433 місяці тому
La Jolla CA , service call - water heater won't light
Return to Hell-side home - please work!!
Переглядів 1564 місяці тому
Return to Hell-side home - please work!!
Water Heater Installation - Exterior Uncovered !!!
Переглядів 1544 місяці тому
Water Heater Installation - Exterior Uncovered !!!
Service call - This one can't be saved!!
Переглядів 904 місяці тому
Service call - This one can't be saved!!
Service Call - Deep in the jungle on a hillside !
Переглядів 984 місяці тому
Service Call - Deep in the jungle on a hillside !
Service Call - No standing Pilot Light
Переглядів 584 місяці тому
Service Call - No standing Pilot Light

КОМЕНТАРІ

  • @longhornjay
    @longhornjay 17 годин тому

    I'm having a terrible time finding that water temp sensor (aka 'thermistor') only finding them on eBay which means they are used, and sometimes take a while to ship. I have a Kenmore gas water heater, Honeywell valve and my unit is flashing 5 error code. It will run intermittently but only on the 'hot' or below setting and it only heats up a small amount of water before cutting off. I am 99.99% sure it's that temp sensor he just popped out. If anyone can share a link for the ones they've found, I would appreciate it. I thought I could find an electrical supply store or something locally but so far nothing. It looks to me like an intentional design flaw to get you to buy a new Gas Valuve or even a whole new water heater since paying someone to install the valve would likely cost about 1/2 to 2/3 or new unit anyhoo...

  • @ken261
    @ken261 22 години тому

    Had an intermittent temp sensor error, so I figured it was just a flaky sensor. I had watched your video (very helpful!) and knew I had everything to swap it out. I wish I had paid more attention to your discussion on the plastic vs metal tip. I didn't check beforehand and I should have. When I pulled the sensor, it was wet. :( I then had to order a whole new gas valve. I loved your tip on using a short pipe to plug the water connection so that I didn't have to drain the tank. The replacement was fairly easy then, and now I have good hot water and a couple spare parts for the gas valve since it was only the back plastic that was bad.

    • @thewaterheaterfactory
      @thewaterheaterfactory 22 години тому

      @@ken261 : that’s great. I’m glad it worked out. Thanks for watching and commenting. Appreciate it.

  • @ed_1969
    @ed_1969 4 дні тому

    Excellent video! Solved my issue also. Unfortunately my screen has a hole too

  • @mistyprice3400
    @mistyprice3400 5 днів тому

    I just pulled my tank outside. Any tips to get the nipples off? They are definitely corroding. Water still holding inside tho.

    • @thewaterheaterfactory
      @thewaterheaterfactory 5 днів тому

      @@mistyprice3400 : yeah that’s a tough procedure. Sometimes if you lay the water heater on the ground and put a wrench on the nipples cause you need somebody to hold the water heater while you put pressure on the wrench if they won’t come off, then you can put a flame or a torch on the nipples to heat up the metal, and that can help you to get them off if they’re frozen on there! Good luck thanks for watching. I think I have a couple videos about it.

    • @mistyprice3400
      @mistyprice3400 5 днів тому

      @@thewaterheaterfactory thank you I've been putting a flame on it but what do you mean by Frozen idk what that means because I thought it would break the pipe and I don't need the break if I'm trying to get it off cuz I want to replace it 😞

  • @willpontius2031
    @willpontius2031 7 днів тому

    No drip leg on the gas line. Water heater in a plastic pan. Water heater sitting on wood. T & P valve should be piped to 6" off the floor. No expansion tank. Draft hood not screwed down. All Code violations where I come from. Not sure about there???

    • @thewaterheaterfactory
      @thewaterheaterfactory 7 днів тому

      @@willpontius2031 : yeah you left out the earthquake straps- definitely code violations going on I didn’t install. It was just there to fix the leak . In my videos when I’m installing water heaters people are looking for the cheapest price possible for a water heater to be installed and they don’t want to pay for all that extra stuff I don’t mind doing it, obviously we’re not getting these water heaters inspected but typically it’s like for like

  • @GooGoo007
    @GooGoo007 7 днів тому

    Where do I get a new thermistor for the gas valve? Thanks!

    • @thewaterheaterfactory
      @thewaterheaterfactory 7 днів тому

      @@GooGoo007 : eBay has cheap valves - I don’t think you’re gonna find that individual part of a thermometer. You might have to order the entire valve to get what you need so your best bet is to find your cheapest source Amazon or eBay or if you have access to a spot where people drop off used water heaters such as a plumbing supply company often in the back they have a drop off spotand you just cruise over there pull a couple valves off some older Water Heaters especially ones that look like they’re leaking chances are the therm will still be good

  • @GooGoo007
    @GooGoo007 7 днів тому

    Thanks for the great video! What do you recommend to seal the gas line connections? What is that white paste over the teflon tape that you used for the gas valve? Thank you!

    • @thewaterheaterfactory
      @thewaterheaterfactory 7 днів тому

      @@GooGoo007 : that’s called a PTFE sealant it’s basically like a Teflon paste- it’s also also referred to as pipe dope- Usually Teflon tape or piped up works really well you could stick with piped up. You can’t really go wrong.- thanks for watching and commenting. Appreciate it.

    • @GooGoo007
      @GooGoo007 6 днів тому

      @@thewaterheaterfactory Thank you for the fast response!

  • @jeffreyplumber1975
    @jeffreyplumber1975 7 днів тому

    easy job other than getting back in there to cut and clean and then having to backup those while tightening the flex . BTW shark bites dont need the plastic insert for copper but still should be reamed as always the insert is meant for pex but is ok to leave inside on copper or remove

    • @thewaterheaterfactory
      @thewaterheaterfactory 7 днів тому

      @@jeffreyplumber1975 : oh that’s right I forgot I don’t mind using a shark bite or a copy of a shark bite those push on fittings as long as they’re not stuck in a wall someplace as long as long as they’re visible and you can inspect them I’ve had pretty good luck. I’ve only had one leak on me, that was pretty easy. I think I was in and out of there and less than an hour. Thanks again for watching!

  • @thewaterheaterfactory
    @thewaterheaterfactory 7 днів тому

    Thanks for watching !

  • @thewaterheaterfactory
    @thewaterheaterfactory 7 днів тому

    Thanks for watching!

  • @thewaterheaterfactory
    @thewaterheaterfactory 7 днів тому

    So while I was editing the video the water heater died. It was still full of water and you could see the valve do the two flash I didn’t include it in this video so that’s for the first Service Call in the basement, but I measured that Thermo Pile voltage it was like 650 V so it could be a circuitboard problem could be the valve is going bad, I still think it’s the water have not heard from The and that was about two days ago

  • @chrissteele8800
    @chrissteele8800 8 днів тому

    Also sometimes I share this, the Bible says that GOD loves us so much that he sent his son JESUS CHRIST to this earth and HE lived a perfect sinless life.And JESUS went to a cross and gave HIS life for us.And rose again in 3 days and who ever will receive JESUS AS THEIR SAVIOR AND ASK HIM TO COME INTO THEIR HEART AND FORGIVE THEIR SINS,HE WILL TAKE YOU TO HEAVEN.

  • @robbienorquay4916
    @robbienorquay4916 8 днів тому

    I followed your instructions and when I removed the thermistor water shot out like a garden hose. So new water heater I’m guessing?

    • @thewaterheaterfactory
      @thewaterheaterfactory 8 днів тому

      @@robbienorquay4916 : I think you just need a new valve- you should kill the pressure to the water heater. That’s the incoming water. We really just need a new valve. I don’t know that the entire water heater needs to be replaced, but that’s up to you.. appreciate the comment thank you for watching!!

  • @jeffreyplumber1975
    @jeffreyplumber1975 8 днів тому

    Great Video! . Thats so cool you got all these parts Im building a small invetory not going into it like you have and bringing tanks to the house. I been robbing junk water heaters from the scrap pile at Ferggies.

    • @thewaterheaterfactory
      @thewaterheaterfactory 8 днів тому

      I have a ton of spare parts because I use them on almost every job. Thanks again for watching and commenting !! Appreciate it! Have a great weekend

  • @thewaterheaterfactory
    @thewaterheaterfactory 8 днів тому

    Thanks for watching!

  • @Hvac-dude
    @Hvac-dude 10 днів тому

    Good job 😊

  • @nicolecolton774
    @nicolecolton774 13 днів тому

    Replaced the gas control valve and it turned blue then went back to red and blinking 7 times. What else could it be? The gas valve was brand new we replaced the old one with.

    • @thewaterheaterfactory
      @thewaterheaterfactory 12 днів тому

      Circuit board - could be a gas pressure issue! I've seen those circuit boards tell you the valves are bad when they are not!

  • @jeffreyplumber1975
    @jeffreyplumber1975 16 днів тому

    I see you try everything to help your customers

    • @thewaterheaterfactory
      @thewaterheaterfactory 16 днів тому

      @@jeffreyplumber1975 yeah I thought that guy was gonna get a heater for me, but he ended up doing something else I guess or it’s still running

  • @jeffreyplumber1975
    @jeffreyplumber1975 16 днів тому

    I just tell it like it is the tank is leaking there is no repairing a leaky tank worth while

    • @thewaterheaterfactory
      @thewaterheaterfactory 16 днів тому

      @@jeffreyplumber1975 : yes exactly

    • @thewaterheaterfactory
      @thewaterheaterfactory 16 днів тому

      But they don’t seem to understand it’s like no you don’t get it even if you patch one side the whole starts on the inside and they see it done in foreign countries - oh hell no

  • @LivingLife128
    @LivingLife128 17 днів тому

    So i just did this to my water heater . i smell a little gas coming from the valve itself. i did a lot of tests and it definitely coming from the valve itself. i scoured the internet for more info and it seems to be a common complaint and according to HW, its normal . some kind of vent hole . so in you opinion with all the ones you have installed, is a little gas coming from the valve normal ? thanks

    • @thewaterheaterfactory
      @thewaterheaterfactory 16 днів тому

      So I would look very closely at your valve and make sure that it’s not cracked. It’s aluminum so sometimes you get these hairline cracks and that’s how the gaskets out. Probably call your local gas company and have them just come out and do an inspection. They have some pretty sophisticated sniffers that can tell you if the gas is normal or unsafe. Sometimes you can smell the gas burning if you have a very sensitive sense of smell, but as far as a leak goes, you want to maybe try and use some soapy water or liquid leak detector and just put it all around the connections and make sure there’s no gas leaking. I typically see the gas valves cracked where the adapter screws in so that’s sort of them where the main amount of gas enters the valve that would be the middle upper left side where the flexible gas line connects to the adapter. Sometimes people put too much Teflon tape on there and they tighten it down and it cracks it right at that point.

  • @tmactheplumber4966
    @tmactheplumber4966 22 дні тому

    This guy was stuck. Homeowners try their best 2 get u 2 change ur schedule.

    • @thewaterheaterfactory
      @thewaterheaterfactory 22 дні тому

      @@tmactheplumber4966 dude wanted an almost new water heater installed for pennies- Nope!

  • @davidwilson7476
    @davidwilson7476 22 дні тому

    i have a rheem water heater with the honeywell electronic . im getting 8 flash in succession with a pause then a 9th final flash. i have had this happen numerous times before and ive did the reset as off switch for one minute then on and spin the turn knob 6 times and it ususally kicks on and fires right up. but last night it didn't fire up at all no matter how many times i tried the rest process. any ideas ?

    • @thewaterheaterfactory
      @thewaterheaterfactory 22 дні тому

      @@davidwilson7476 replace the chamber sensor contact RHEEM and they can send you replacement parts

    • @davidwilson7476
      @davidwilson7476 22 дні тому

      @@thewaterheaterfactory thanks a million guys. is there certain parts i should identify to the tech specialist whenever i talk to them, or just tell them "chamber sensor contact.

  • @thewaterheaterfactory
    @thewaterheaterfactory 22 дні тому

    Ha - Forgot to give it a title and description - seemed to help my views - Go figure!! Thanks for watching!!

  • @tylerangieslayton7455
    @tylerangieslayton7455 25 днів тому

    Mines got the 7 blink after replacing the thrmopile but won't let the pilot stay lit ? Can u help please 😅

    • @thewaterheaterfactory
      @thewaterheaterfactory 25 днів тому

      @@tylerangieslayton7455 try the reset procedure if the main burner fires up. Otherwise you will need to replace the valve completely.

  • @jeffreyplumber1975
    @jeffreyplumber1975 27 днів тому

    got it back to life Win! 2016 the3y wont miss the window or the grommet

    • @thewaterheaterfactory
      @thewaterheaterfactory 27 днів тому

      @@jeffreyplumber1975 naw - yeah easy fix when you get it the first time!

  • @thewaterheaterfactory
    @thewaterheaterfactory 27 днів тому

    Thanks for watching !

  • @iLL_Eaglez
    @iLL_Eaglez 28 днів тому

    How did you even get that thermopile clamp to come out? My red and white wires fell out while I was reconnecting the wire inside the control panel back to the circuit board. For some reason I am unable to reconnect them.

    • @thewaterheaterfactory
      @thewaterheaterfactory 28 днів тому

      @@iLL_Eaglez : I use a pair of needle nose, pliers to grip the top and the bottom of the connector. Then I hold the circuitboard cover and pull it all out as one even Unit that way it doesn’t put stress on the wires.

    • @thewaterheaterfactory
      @thewaterheaterfactory 28 днів тому

      @@iLL_Eaglez : for some reason, the connector on my little battery pack comes out easily. It’s weird it goes in and comes out effortlessly and there’s not a lot of pressure or tension so it’s really nice. Just got lucky. I guess- random

    • @iLL_Eaglez
      @iLL_Eaglez 8 днів тому

      @@thewaterheaterfactory apparently the thermopile clamp was stuck to the back of the housing unit..I ended up getting a new complete gas valve with new connections under warranty last week and installed it..having taken apart my water heater a few times already and cleaning it and replacing parts I fully understand how it works. Thanks for sharing boss!

  • @dave5334
    @dave5334 29 днів тому

    Very informative. My water heater is at least 10 years old I think. I'm not exactly sure I've only been here a few years. Would I be better off just buying a new water heater? I dont think it's ever been serviced before

    • @thewaterheaterfactory
      @thewaterheaterfactory 29 днів тому

      @@dave5334 yeah probably can’t go wrong with the new one most people fix theirs cause they just don’t and I’ll have the money available at the moment. Thanks for watching.

  • @BADBRAD1959
    @BADBRAD1959 29 днів тому

    A good reason not to buy Rheem or Richmond water heaters. AO Smith , Bradford white use a simple resettable thermal switch that shuts off the gas valve.

  • @jigishparikh1968
    @jigishparikh1968 Місяць тому

    So replacing the burner assembly is a short term fix because it does not address the issue of the leak that caused those holes over time. Wouldn't a new burner will also be damaged over time due to the leak ?

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      Of Course - Its condensation that falls onto the burner when the gas (fuel) is igniting usually only lasts for the first 30-40 mins the water heater is running once it reaches temperature the conditions for condensation change but its different with every water heater - depends on engineering and location of water heater temperature of water ext. - I don't prefer the Ultra Low nOX burner Assembly's for that reason the screens are susceptible to erosion damage.

    • @jigishparikh1968
      @jigishparikh1968 29 днів тому

      @@thewaterheaterfactory Maybe you can help me understand this hole problem. The mesh itself is not an air-tight design or is it? Wouldn't gas escape from it anyway and burn without holes as well ?

  • @fishhernandez5231
    @fishhernandez5231 Місяць тому

    Good job 🎉

  • @tmactheplumber4966
    @tmactheplumber4966 Місяць тому

    I mighta walked too !

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@tmactheplumber4966 yeah you know I go over that job in my mind and I’m like maybe I should’ve stayed and just put the damn thing in and got paid but at the time being there looking at everything I was just like this this is just not gonna go well, and it probably wouldn’t have. You can’t really see it in the video but those stairs were extremely steep but part of me you know there’s there’s this part of me that’s like I like trying to make stuff work and make things happen. Just make miracles happen but I’m trying to learn to walk away from situations thatare too risky. The guy was trying to lowball me which I hate.

    • @tmactheplumber4966
      @tmactheplumber4966 Місяць тому

      I no longer tackle water heaters with steps that steep. Nevermind putting it on blocks like that type job.

  • @matthewfasullo4983
    @matthewfasullo4983 Місяць тому

    Those also have a water sensor in it and they are super sensitive and if any bit of water gets on it, it will shut off completely. Also there is a filter on top that needs to pull out so it can get cleaned. It also exhausts cold air so it needs to be either vented outside or be in a big room. It could freeze his water lines

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@matthewfasullo4983 thanks for watching - well it’s San Diego so I’m not sure that that would happen, but I had to pass on this install. My biggest concern was where the heck does all the condensation water go? We’re down in a bowl.

    • @matthewfasullo4983
      @matthewfasullo4983 Місяць тому

      @@thewaterheaterfactory it would need a condensate pump and have a line run outside

  • @jeffreyplumber1975
    @jeffreyplumber1975 Місяць тому

    guess i didnt post my other comment but I agree if you werent getting a good pay out not a great job but condensate pump work good draw almost no current and cheap

  • @ganeshnarayan5505
    @ganeshnarayan5505 Місяць тому

    Yep sometimes you just got to move on. Great video duo

  • @jeffreyplumber1975
    @jeffreyplumber1975 Місяць тому

    BTW the heat pump is efficient but its not running off a 100 watt lightbulb socket properly Im no electrition . that old shack probebly maxed out on electrical. just checked its 15 amps no way should it not have a dedicated home run technically

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@jeffreyplumber1975 : yeah I was trying to tell the owner you need a dedicated circuit just for safety I mean, who knows what else is sharing that circuit a microwave a vacuum cleaner, a hairdryer that breaker would be popping all the time the environment was going into was super humid because it just flooded and those things put out like two or 3 cups of water every single day where is that water gonna go? there was no way to get the condensation line to exit the building because the building 6 feet below grade

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@jeffreyplumber1975 : I don’t even think those lightbulb sockets come with a ground?

  • @thewaterheaterfactory
    @thewaterheaterfactory Місяць тому

    Thanks for watching - Cant get the condensation line out of the basement lowest point under the house! Let me know if you have any ideas about how it may have worked!

    • @jeffreyplumber1975
      @jeffreyplumber1975 Місяць тому

      A condensate pump brother not that expensive easy peasy ! but the rest of the job in its entirety is involved. I never installed a heat pump but as mentioned by HVAC-dude I belive a metal vent is not part of the program they gotta be plastic I think too. Personally I dont get involved in crunching numbers figuring out whats the most efficient Im not a salesman I can bullshit telling people this is the best way but Im not doing that . also there are unknowns there are huge cost saving rebates for an owner to concider In Ca i think new homes are requiring electric in some areas all that green shit is coming at least in new homes . Progams also exist to train and certify (indoctrine)installers Im not saying it cant be a worthwile thing just that I havent pursued it I am semi interested in it

  • @Hvac-dude
    @Hvac-dude Місяць тому

    You'd have to run pvc venting to

  • @chriscermak3188
    @chriscermak3188 Місяць тому

    I learned a long time ago, do one thing, be really good at it. That's how you make money. Ask me if i always followed that rule !

  • @smolpener7430
    @smolpener7430 Місяць тому

    I don't really see a point to the hybrids. In the limited scenario's where they work well, there are significantly better options. Most people will never experience a gas outage either.

  • @hmc2s
    @hmc2s Місяць тому

    Hot water heater not working

  • @InvaderGeoff
    @InvaderGeoff Місяць тому

    Just pulled apart a similar model rheem where the pilot would not light at all, after confirming spark and gas at the control valve when the pilot button was depressed. Found exactly the same thing, melted and broken pilot tube. I can't find anyone else complaining about this on the internet, so I figured I would comment in case others are having similar issues with a pilot that won't light at all.

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@InvaderGeoff thanks for sharing ! Those pilot tubes are crazy long. They don’t make them like that anymore thank God thanks for watching.

  • @adriansoto16
    @adriansoto16 Місяць тому

    Good tips buddy

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@adriansoto16 : I appreciate the comment thank you! Hopefully some of these tips help some people out! Appreciate you watching. Have a great weekend!

  • @tmactheplumber4966
    @tmactheplumber4966 Місяць тому

    I think this is 1st time I've seen u swap out a tank less. I use sharkbytes at times.

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@tmactheplumber4966 yeah that was literally the first time I’ve ever touched a Tankless. Been trying to expand my my knowledge and work on different different types of things to try and keep the money rolling in. Thanks again for watching as always.

    • @jeffreyplumber1975
      @jeffreyplumber1975 Місяць тому

      @@thewaterheaterfactory thats the spirit ! I thought about tankless service as well not sure how much a basic flush goes for probebly 150 to 200 its an hour of time and vinegar or cleaning solution around 20 bucks my guess I got a pump that i use for pumping out tank water heaters when they wont drain on change outs which I highly recomend if the drain gives trouble easier to pump it out

  • @jeffreyplumber1975
    @jeffreyplumber1975 Місяць тому

    Nice I started collecting parts plus got my first job on repair not really trying to make a killing or anything I just only worked on them a few times in 35 years or so . I installed a scatch and dent for a neighbor 9 years ago its a 12 year A/O smith well it hasent been lighting even holding butten down Anyway , I hear other plumbers complaining that these warrantys aint worth a damn so to hewlp my neighbor I called the warranty number they sent me a new valve and burner assembly and it was on my steps in under 24 hours from rancho caless than 30 miles away installed it it went perfect. I been looking for old water heaters to scavenge for parts . I could expand it to swapping anode rods and new drain valves confidence is boosting some maybe ill even make make a millivolt supply with batteries and resisters. Trying to understand the differances in the valves there is one for 1 inch tank insulation and another for 2 inch insulation you mentioned 40 gal are differant than 50s thanks for sharing too bad camera died!

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@jeffreyplumber1975 yeah that’s how it starts. I worked on 100 gallon water heater today commercial grade heavy duty. I had to watch tutorials on the way to the job site but it helped couple videos on UA-cam because I didn’t know shit about this water heater turned out it was the damper, pinpointed it right away it was great

  • @martinconnell8510
    @martinconnell8510 Місяць тому

    Why where you replacing it and what brand was the tankless

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@martinconnell8510 I think it was a Norris. I didn’t really pay attention to it. It wasn’t working and they didn’t want to fix it and they asked me if I could remove it and then install the water heater they bought.

  • @liwarren8774
    @liwarren8774 Місяць тому

    like to see the final set up. I have a similar case, someday will change back to gas water heater.

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      Yeah the camera died - Installed the water heater connected ducting owner is going to put on a shed

  • @thewaterheaterfactory
    @thewaterheaterfactory Місяць тому

    Thanks for watching !!

  • @elizabeththompson3286
    @elizabeththompson3286 Місяць тому

    Totally worked!! You are awesome 🎉

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@elizabeththompson3286 yeah it’s it. It might only work for a week or two or even less but you could just keep resetting it until you come up with a better solution. I had to reset mine this morning. It only takes 60 seconds to go through the reset procedure I’ve just been too busy and too lazy to work on mine.

  • @smolpener7430
    @smolpener7430 Місяць тому

    I have a similar water heater giving a 7 flash code. After replacing the thermopile and the entire control valve, it's still giving 7 flashes. Is it possible for the chamber sensor to cause a 7 flash?

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@smolpener7430 : so replacing the thermal pile will not correct a seven flash you need to either make sure that you put a new circuit board on and a new valve body or an entirely new valve. You should not get the same code coming back. If you replace the valve entirely, you can try using the reset procedure to clear it out and then see if it comes back just so you can get hot water in the meantime my water heater at home is currently doing this to me, once every four days, I gotta use the procedure on it .

    • @thewaterheaterfactory
      @thewaterheaterfactory Місяць тому

      @@smolpener7430 chamber sensor not the cause

    • @smolpener7430
      @smolpener7430 Місяць тому

      ​@@thewaterheaterfactory I replaced the entire valve control with a brand new one from rheem directly. I've been resetting it fine, but it needs to be reset multiple times to get the tank up to temperature. Once the tank it heated, the light will stay blue until someone gets in the shower. After doing the 15 very high, 15 high, 15 pilot reset I found in one of your other videos, it changed from a 7 flash to a 9 flash, and I did 3 different readings on the chamber sensor that came up as 7.7k ohms, 99.1k ohms, and 64.2k ohms. If it's pertinent, after a reset the fire coming out of the burner starts off blue, then slowly turns purple, then red/orange before shutting off, all over the course of about 20 minutes.

    • @smolpener7430
      @smolpener7430 Місяць тому

      After restarting it regularly, by turning the knob to off and waiting for it to discharge, it ran for about 15 minutes, then it shut off and gave another 7 flash code. Another chamber sensor check is giving me 8.6k ohms, and slowly rising over time.

    • @smolpener7430
      @smolpener7430 Місяць тому

      @@thewaterheaterfactory One last update. I replaced the chamber sensor and the 7 flash is gone.