Dore Woodman
Dore Woodman
  • 49
  • 574 741
Epic Solar PV Installation: How we installed Enphase Microinverters and the Alpha ESS Smile B3 +
"Epic Solar PV Installation: Harnessing the Power of Alpha ESS Smile B3 + Enphase Microinverters"
Welcome to our exclusive journey of installing a state-of-the-art solar PV array using Alpha ESS Smile B3 and Enphase Microinverters. This comprehensive guide demonstrates the ins and outs of our energy revolution.
**Unveiling The Power of The Sun**
From beginning to end, we delve into the practical steps taken in transforming sunlight into usable energy with the extraordinary Alpha ESS Smile B3 and the highly efficient Enphase Microinverters in the IQ7A and IQ7+.
**Experience Our Installation Journey**
We let you in on how we meticulously assembled this remarkable technology. Our step-by-step process, the challenges we faced, and the triumphant moments of our successful installation, we're sharing it all with you.
**Why Alpha ESS Smile B3 & Enphase Microinverters?**
We don't just show you the how but also the why. Discover the unique features of these remarkable devices and their role in shaping a sustainable future.
**What You Stand To Gain**
The benefits of our solar PV array goes beyond generating clean energy. It’s a step into a more sustainable and energy-independent future, a future we believe everyone should be a part of.
Don't forget to like, share, and subscribe for more insightful content like this. Stay updated with our latest renewable energy projects and let's power up the world together.
#SolarPVInstallation, #AlphaESSSmileB3, #EnphaseMicroinverters, #RenewableEnergy, #SustainableFuture, #EnergyIndependence
Visit our website at www.dorewoodman.co.uk to discover more about our renewable energy initiatives.
Переглядів: 2 289

Відео

Step-by-Step Guide: Installing a Solar PV Array with Enphase Microinverters | Renewable Energy
Переглядів 25 тис.Рік тому
Welcome to our comprehensive guide on "How we Installed a Solar PV Array with Enphase Microinverters". This video walks you through the entire process, breaking down each step for easy understanding. In today’s video, we bring to you an in-depth tutorial about the installation of a solar photovoltaic (PV) array using the advanced technology of Enphase Microinverters. We believe in the power of ...
Heat pumps, Solar PV, Battery Storage and Enphase Microinverters
Переглядів 986Рік тому
In this episode, take a trip with us for the week as we navigate the day to day work carried out at Dore Woodman and the projects we are involved with day to day. We have underfloor heating projects, air source heat pumps, solar pv, battery storage, solar pv designs and radiator calculations. #solarpanel #enphase #battery #alphaess #microinverter #jinko #ashp #renewableenergy #sustainability #s...
Welcome to the Doré Woodman YouTube channel
Переглядів 869Рік тому
Doré Woodman are an MCS Accredited renewable technologies company. We provide all the requirements from Air and Ground Source Heat Pumps and Solar PV and Battery Storage to EV charging, UFH and Comfort Cooling. We are showcasing and educating anyone who is interested or curious to find out more about these technologies and guide you through the best and sometimes worse systems and devices avail...
Enphase Microinverters - Pioneering the Future of Solar Energy
Переглядів 3,2 тис.Рік тому
Title: "Enphase Microinverters - Pioneering the Future of Solar Energy" Description: 🔆Introduction🔆 Get ready to delve deep into the future of solar energy - Enphase Microinverters! In this video, we take you through the cutting-edge technology that's revolutionizing the solar power industry. 🔆Video Content🔆 Discover how Enphase Microinverters outshine traditional inverters in harnessing solar ...
Revolutionizing Flat Roof PV Installation - Harness Solar Energy with the Van Der Valk Mounting Kit
Переглядів 12 тис.Рік тому
Title: Revolutionizing Flat Roof PV Installation - Harness Solar Energy with the Van Der Valk Mounting Kit Description: Welcome to a comprehensive guide on the future of sustainable energy - the "Flat Roof PV Installation" using the distinguished Van Der Valk Roof Mounting Kit. Witness a step-by-step demonstration of this cutting-edge technology, making solar energy harvesting a breeze for flat...
MyEnergi Eddi - What is going on?
Переглядів 3,7 тис.Рік тому
This Eddi Solar PV diverter needed attention. When excess solar generation was being produced it was exporting to the grid as opposed to generating hot water so we went to investigate…
The Ultimate Guide to Solar PV: In-Roof GSE Integration & Van Der Valk Flat Roof Mounting Install
Переглядів 12 тис.Рік тому
The Ultimate Guide to Solar PV: In-Roof GSE Integration & Van Der Valk Flat Roof Mounting Install
Unleash the Power of Renewable Energy: Solar PV with FoxESS H1 Hybrid Inverter & Battery Storage
Переглядів 9 тис.Рік тому
Unleash the Power of Renewable Energy: Solar PV with FoxESS H1 Hybrid Inverter & Battery Storage
New Samsung Air Source Heat Pump Launch #SamsungHTQuiet
Переглядів 6 тис.Рік тому
New Samsung Air Source Heat Pump Launch #SamsungHTQuiet
Mitsubishi Ecodan - Outstanding Performance
Переглядів 12 тис.2 роки тому
Mitsubishi Ecodan - Outstanding Performance
Stuart Turner Mainsboost - Maximise your water flow rates with an Accumulator
Переглядів 3,9 тис.2 роки тому
Stuart Turner Mainsboost - Maximise your water flow rates with an Accumulator
Heat Pump Electrical Headaches
Переглядів 9602 роки тому
Heat Pump Electrical Headaches
Solar PV Diverters, Mixergy cylinders and Caleffi Antifreeze Valves
Переглядів 1,2 тис.2 роки тому
Solar PV Diverters, Mixergy cylinders and Caleffi Antifreeze Valves
Heat pumps and Self Builds
Переглядів 9842 роки тому
Heat pumps and Self Builds
Mitsubishi Ecodan Wireless Controller Connection and Dipswitches
Переглядів 7 тис.2 роки тому
Mitsubishi Ecodan Wireless Controller Connection and Dipswitches
Mitsubishi Ecodan with George Clark
Переглядів 8 тис.2 роки тому
Mitsubishi Ecodan with George Clark
Mitsubishi Ecodan Installation and Mixergy Smart Hot Water Cylinder Installation
Переглядів 14 тис.2 роки тому
Mitsubishi Ecodan Installation and Mixergy Smart Hot Water Cylinder Installation
Vaillant Arotherm Plus Air Source Heat Pump Installation
Переглядів 21 тис.2 роки тому
Vaillant Arotherm Plus Air Source Heat Pump Installation
Air Source Heat Pump - Mitsubishi Ecodan - LPG removed
Переглядів 1,9 тис.2 роки тому
Air Source Heat Pump - Mitsubishi Ecodan - LPG removed
Mitsubishi Ecodan Retro-fit Installation
Переглядів 8 тис.2 роки тому
Mitsubishi Ecodan Retro-fit Installation
Mitsubishi Ecodan - MELCloud and WiFi Interface connection
Переглядів 31 тис.3 роки тому
Mitsubishi Ecodan - MELCloud and WiFi Interface connection
Heat Pumps and Hydrogen - What is the future in heating?
Переглядів 1,1 тис.3 роки тому
Heat Pumps and Hydrogen - What is the future in heating?
Heat Pumps The Ugly Truth - The Rebuttal
Переглядів 55 тис.3 роки тому
Heat Pumps The Ugly Truth - The Rebuttal
Vaillant Arotherm Plus Installation
Переглядів 17 тис.3 роки тому
Vaillant Arotherm Plus Installation
Retrofit Mitsubishi Ecodan Heat Pump in a renovated home
Переглядів 6 тис.3 роки тому
Retrofit Mitsubishi Ecodan Heat Pump in a renovated home
Mitsubishi Ecodan wireless controller setup tutorial
Переглядів 29 тис.3 роки тому
Mitsubishi Ecodan wireless controller setup tutorial
Mitsubishi Ecodan Air Source Heat Pumps
Переглядів 81 тис.3 роки тому
Mitsubishi Ecodan Air Source Heat Pumps
Vaillant Arotherm Plus Air Source Heat Pump 2021
Переглядів 11 тис.3 роки тому
Vaillant Arotherm Plus Air Source Heat Pump 2021
What is the Best Air Source Heat Pump 2021 UK - Mitsubishi Ecodan and Vaillant Arotherm Plus
Переглядів 72 тис.3 роки тому
What is the Best Air Source Heat Pump 2021 UK - Mitsubishi Ecodan and Vaillant Arotherm Plus

КОМЕНТАРІ

  • @joshuat6124
    @joshuat6124 9 днів тому

    What a dreadful noise, I can't tell if he's being sarcastic or not...

  • @yp77738yp77739
    @yp77738yp77739 10 днів тому

    Please can you help me understand something. You can fit approx 10 microinverters in to one 20A fuse. Is it possible to have another 2x 20A fuses being fed by by another 2 strings of 10 IQ8s please. I’m wanting to install 30 panels over 2 SE roof with a shading factor of 0.78, so whilst panels are cheap I thought it made sense to overcompensate with panels as my per panel output would be low. It’s feeding 2 5P (possibly 3) batteries if that’s important. My potential installer is telling me that 20 panels is the maximum I can have, I’m struggling to accept they are correct. Thanks.

  • @markrainford1219
    @markrainford1219 12 днів тому

    How do you replace the inverter in the top middle panel when it fails?

  • @TV-xt6et
    @TV-xt6et 18 днів тому

    What do you do to prevent birds and other critters getting under the panels for shelter nesting etc?

  • @Beariam24
    @Beariam24 22 дні тому

    Get your guys the correct termination tools!? Eg correct cable stripper, depth guide for mc4 and torque socket for MC4 and for the panel clamps. And SWA is not double insulated internally. Use correct dc SWA or correct dc cable! No wonder why I loose jobs on price FFS

  • @lisalowy2443
    @lisalowy2443 28 днів тому

    Would be good to hear it without you talking. I can still hear it when you are talking but good to have both as most of the time no one will be talking next to the heat pump !

  • @Bertyification
    @Bertyification Місяць тому

    Great video. Thanks for the instructions!

  • @leshutch3166
    @leshutch3166 Місяць тому

    Hi had a lightning storm lastnight, this morning have no power to Mitsubishi control panel everything else has power any help b much appreciated thanks les

  • @kn4cc755
    @kn4cc755 Місяць тому

    I've watched many videos on UA-cam showing solar system installs using Enphase equipment and NOBODY shows the commissioning/startup process. There must be some reason, either the process is restricted by Enphase or the installers are protecting their market in some way. Of course, this means that all maintenance going forward will be closed to any but those installers. If that business fails, so does your system. Not acceptable.

  • @Hatch69558
    @Hatch69558 Місяць тому

    Beautiful install mate and the video is very informative. Just done my first electrical install of one of these and while it’s more unnecessarily complicated than it needs to be with the volt free inputs into the wiring centre it’s a great bit of kit when it gets up and running. I know you were using the Vaillant controllers there for the radiator zone but if you had to use a third party controller how do you get around the need to have a volt free signal coming from the room stat?

    • @dorewoodman
      @dorewoodman Місяць тому

      Thank you for your comment ... if the thermostat didn't have a volt free connection we would just introduce a contactor/relay to do the job

  • @tranquiltunes3196
    @tranquiltunes3196 2 місяці тому

    how do you turn on the radiators to heat the house

  • @stephenbrickwood1602
    @stephenbrickwood1602 2 місяці тому

    I think that the grid is a cashflow investment and lost grid customer demand will make higher $kWh for all remaining grid electricity users. Cashflow on the grid investment value is important to the grid owners. This is a massive problem for the grid when the SUN SHINES. No grid electricity is needed. CASHFLOW DEATH. 😮😮 When the home battery is full and feeding home demand, grid CASHFLOW DEATH.😮😮 When the wind blows grid owners get electricity to sell to customers. Grid Electricity will be an imploding business and nuclear electricity makes it even worse.😮😮 In Australia fossil fueled generators are sucking in governments tax payers money. Nuclear promoters want government money to build nuclear electricity generators. Nuclear promoters want government disaster insurance. Nuclear promoters will then want private investors but government guaranteed CASH FLOWS. WTF. The distant wind turbines will need the grid to supply the millions of customers still demandng supply. I bet the fossil fueled generators are even running at a loss for tax purposes 🙄 😮😮 So PV rooftop return on investment is not taxed and will increase in value as grid electricity supply $kWh prices must increase. Remember in a warming latitudes heating costs will crash. Petroleum for emergency winter weeks heating will be nothing. Petroleum for petrochemical industry and road building and maintenance will remain as usual. 20years to replace all ICE vehicles. (Internal combustion engines)

  • @Helsingfors-h2c
    @Helsingfors-h2c 2 місяці тому

    I'm wondering what would happen if a gas meter located near breakers had some gas leakage and the breakers were switched on at the same time.

    • @markrainford1219
      @markrainford1219 12 днів тому

      Your neighbours would be calling the gas hotline because of the smell before gas gets to a dangerous level.

  • @paulgarrett7703
    @paulgarrett7703 3 місяці тому

    Is there any chance you could tell me what size supply cable was needed for the unit please?

  • @bernardholdsworth2171
    @bernardholdsworth2171 3 місяці тому

    Does a smart meter have to be installed for these?

    • @dorewoodman
      @dorewoodman 3 місяці тому

      No, but we would install a generation meter and metered Enphase Envoy

  • @plumjam
    @plumjam 4 місяці тому

    Horrendous. Imagine a whole estate full of these things. As if modern traffic noise wasn't enough. This ruins people's health.

  • @j.newham6284
    @j.newham6284 4 місяці тому

    At night is to disturbing

  • @debs55
    @debs55 4 місяці тому

    Hi bill do you leave your emersion on all the time because so far I'm not thrilled with it as radiators coming on when it feels like it.

  • @dharveymi
    @dharveymi 4 місяці тому

    Does anyone know its the GSI system or something similar is available in the states?

  • @pmbpmb5416
    @pmbpmb5416 5 місяців тому

    Would you choose Vaillant or Mitsubishi ?

    • @dorewoodman
      @dorewoodman 5 місяців тому

      Vaillant without a doubt

    • @pmbpmb5416
      @pmbpmb5416 5 місяців тому

      Thanks for taking the trouble to reply . I ask because our installer is suggesting two ecodans 11kw cascaded . All I see on UA-cam from installers of quality is the use of Vaillant , the installer argues vaillant controls were variations of their gas boiler controls and that their customer service is rubbish . This is leaving me in a quandary , of course it may be to do with supply discounts from either and they make more money on the ecodans ,,however they do have a good reputation on installs

    • @dorewoodman
      @dorewoodman 5 місяців тому

      @@pmbpmb5416 mitsubishi have had a range of issues over the past 18 to 24 months and the Vaillant customer service and product is far better than the Mitsubishi Ecodan. I would, without a doubt, install the Vaillant. Where are you guys based?

    • @pmbpmb5416
      @pmbpmb5416 5 місяців тому

      Thanks for that info , unfortunately in south Wales where there is a dearth of reputable installers, nearest heat geek elite is Cardiff for example and they don’t do solar as well , I am trying to tie up the install together .

  • @georgemcmillan928
    @georgemcmillan928 5 місяців тому

    As you probably know melcloud has been down there for about a week. Ive tried numerous times to reconnect using the WPS way and also using the SDDI & KEY method to no avail. Only think i can see different is at the start my unit light is on constantly and not flashing. Cant see any other reason why its not connecting. Ive followed both ways and nothing. Any help or tips please ? Many thanks

  • @yanso5271
    @yanso5271 5 місяців тому

    To me it is not noisy at all. What model is that and what is the published sound level in dBA?

  • @glassdomedesign
    @glassdomedesign 5 місяців тому

    Very helpful - we have 4 panels with IQ7As at the moment with the Tesla 2 battery and gateway. We’re thinking of adding more panels but on an outbuilding. Is it as simple as wiring these into a circuit and the system will pick them up? Or do they need to be programmed to the gateway to make them work?

  • @eugenrullz
    @eugenrullz 5 місяців тому

    Just for my own curiosity, why the mid clamp are not on the longside (15-20% from edges) and are mounted on the short side. I have yet to see a panel manufacturer to indicate this time of mounting. It can be done but with a pannel with no more than 1.8m lenght.

    • @stephenbrickwood1602
      @stephenbrickwood1602 2 місяці тому

      Did you get an answer ? I had the same question. 😮

    • @eugenrullz
      @eugenrullz 2 місяці тому

      @@stephenbrickwood1602 nope. But im sure that this was a bad instal. Dont know why would they upload this tonyoutube though 🧐

  • @dionnevoller2903
    @dionnevoller2903 5 місяців тому

    That consistent “hum” I could hear when you were talking would drive me nuts - my neighbour is having one fitted this week - and honestly I’m dreading it - it will be like someone running a bloody lawn mower 24/7 and if at night if I want our bedroom window open it’s going to be awful - they should be bloody banned - horrible bloody things - and it’s within a metre of our border with him - he didn’t even tell us he was having one fitted - bloody awful - going to ruin the peace in our garden

    • @karan-nq1dl
      @karan-nq1dl 4 місяці тому

      The microphone was literally on top of the heat pump and was still quiet. You're not gonna hear it from your house...

  • @lesleycassell
    @lesleycassell 5 місяців тому

    We moved in to our converted barn 9 years ago (bought from a previous owner who didn't really live in it). It has an ECODAN ASHP for underfloor heating and hot water. It is expensive to run and gives nothing back. I have turned off the heating and replaced it with 3 Everett stoves, which are really good. Although the hot water is set to 24hrs it is always cold, so we have to repeatedly use the boost button (up to 3 times) to heat water for washing up etc. I have really struggled to find anyone to offer a service, the original installers have gone. I have recently contacted a company I saw on a recommendation of our local face book page who wants £400 plus vat and extra if the glycol needs topping up. Luckily I have a gas Aga (aims programmable) which help to heat the property; gas central heating would be preferable but with the cost to convert and net zero agenda this is not a possibility. I am so frustrated!!

  • @GWAYGWAY1
    @GWAYGWAY1 5 місяців тому

    What the hell use is a solar system to the customer if it shuts down for SAFETY when the mains is lost???? How do you tell him is completely devoid of electricity and his freezer thaw out the fridge dies and they will be sitting in the dark without anything to do. Why can the solar system and any battery not keep the house live because of the god safety? Is it because the feedback to the mains in not possible because a switch over device cannot know when the mains goes off as there is still 230 volts available to it. The policy of solar appears to be the advantage of the power companies financial position. Surely there has to be some sort of standby power available to keep it all going , I had a power down for a week because of a u found wet fault in the mains several times in the passed year until they replaced the whole cable system along the road.

    • @deepknowledgetown
      @deepknowledgetown 4 місяці тому

      That's where ATS comes in to limit the power produced from solar panels and stop it from exporting to grid during power outage. Your installer should be able to give you more information on this.

  • @onlythetruthfull
    @onlythetruthfull 5 місяців тому

    No smoke alarm was fitted in my Attic I fitted one myself and linked it to others in the bungalow. The so-called electrician had very little knowledge of how to wire the system up. The installers were called back several times because the inverter and battery system were installed incorrectly and only half the battery storage was fitted or delivered. The MCS certificate was issued but I complained to the two associations about the workmanship, both did not help because the company although using the logos on the website and correspondence had failed to pay the membership fee for the year. The Ikano Bank was of little use when I informed them not to pay the company until the work was sorted they paid them despite being told all the system had not been delivered ie breach of contract. Saint Solar I believe is now out of Business. I have nearly paid the loan back to the Ikano Bank. So despite looking for a recognised company belonging to the correct associations and MCS-trained you still can only believe word of mouth from satisfied genuine customers.

  • @nic47531
    @nic47531 5 місяців тому

    For the flat roof does there have to be ply immediately under the surface or can the racking system sit on felt thats layed ontop of rigid insulation?

  • @pmbpmb5416
    @pmbpmb5416 5 місяців тому

    I have an installer looking to specify Mitsubishi , he notes Vaillant customer support is poor and that he says their controls were variations off their gas boilers . The Mitsubishi though were the result of their experiences in the air to air market . I still can not decide which manufacturer to go with .

  • @sharifulmazumder2478
    @sharifulmazumder2478 6 місяців тому

    Why do you need two? Do you need one for hot and cold? Or just purely just to manaage expectations for taps and bathrooms

    • @dorewoodman
      @dorewoodman 6 місяців тому

      It is just how it was calculated by looking at the incoming pressure, cold main flow rate, number of outlets, shower heads and flow rates etc.

  • @nic47531
    @nic47531 6 місяців тому

    Are these racks much more costly than renusol tubs?

    • @dorewoodman
      @dorewoodman 6 місяців тому

      Hi Nick we have never really installed the tubs but I would expect they are slightly higher in cost

  • @nic47531
    @nic47531 6 місяців тому

    Do enphase microinverters hum underneath panel like a string inverter would?

    • @dorewoodman
      @dorewoodman 6 місяців тому

      No that we have noticed or that customers have commented on

  • @CallumMedway
    @CallumMedway 6 місяців тому

    With the multiple zones, multiple underfloor zones, buffer and secondary pumps I would think 3.65 as a SCOP is high. Ideally remove the buffer, remove the two secondary pumps remove the actuators on the underfloor heating as well as the mixer valve on the underfloor manifold. install flow gauges next to the zone valves and do the calcs depending on the max flow rate requirement of each zone. the system needs minimum 55l of water so you could use the buffer as a accumulator on the return if the underfloor is too small as a single zone. Its a great install nut I do think the Valliant design assumes the installer doesn't understand hydronics.

  • @TrevHutt
    @TrevHutt 7 місяців тому

    Excellent

  • @veneration1
    @veneration1 7 місяців тому

    I have 62 homes being built next to me, all 60 will have heat pumps, will I likely notice them ? I am 30 metres away from the nearest new home being built. I am concerned as I live in a quiet village and this is 60+ homes who will have them. I think the builders were forced to install them due to the government.

    • @custardtart1312
      @custardtart1312 3 місяці тому

      I would imagine the noise from heat pumps is the least of your worries if 60 homes are popping up near you.

  • @shmayazuggot8558
    @shmayazuggot8558 7 місяців тому

    I do not understand why one would do this? Have you guys ever installed solar before?

  • @howardwalker3593
    @howardwalker3593 7 місяців тому

    Clear as mud. The instructions do not show much on this video. Far better to write a,set of clear instructions. This does not work on my system

  • @joewentworth7856
    @joewentworth7856 7 місяців тому

    I would have been tempted to install it as east west facing aray any and get a longer generation period with less of a mid day peak. Was this an option?

  • @christinewhite3749
    @christinewhite3749 8 місяців тому

    I had discounted the Mixergy as I had been told that when connected to an ASHP it reverted to being a standard emersion heater and you didn't get the benefit of choosing how much water you needed. For the most part I will be a single person living in a 4 bed 2 bath house so would want the capacity when people came to stay but on a day to day basis would probably only need 50% of the tank if not less. I will also have Solar PV, Harvi and eddie and a Give Energy all in one battery. Can you confirm the Mixergy tank would still work as required with my setup?

  • @christinewhite3749
    @christinewhite3749 8 місяців тому

    This was an extremely informative video as I have been offered a Mitsubishi by an MSC recommended fitter but my local authority had used a Vaillant for a retrofit they had just done and I wasn't sure which would be better. The fitter has promised to do a full evaluations when he comes to see me so we will know what size I need but I do like the idea of the R290 refrigerant that the Vaillant uses so I might be able to pursued him to try a different manufacturer. I have just started on a renovation of a 1950's semidetached single brick bungalow - It will have a wrap around extension to two sides and external insulation on the front, roof has been removed and will have a 2 bedroom one bathroom dormer. The builder knows I want extra insulation on the party wall and as I am having under floor heating throughout. This should suit an ASHP perfectly.

    • @pmbpmb5416
      @pmbpmb5416 5 місяців тому

      Why did you choose ?

    • @christinewhite3749
      @christinewhite3749 5 місяців тому

      @@pmbpmb5416 Mitsubishi now do an ASHP with the new refrigerant so I am going with this

    • @pmbpmb5416
      @pmbpmb5416 5 місяців тому

      Thanks , useful , am now contacting supplier to ensure that’s what they are specifying.

    • @pmbpmb5416
      @pmbpmb5416 5 місяців тому

      Although I should check is that within the unit or in the circulatory pipes ?

  • @LynneWilliams-yy1dk
    @LynneWilliams-yy1dk 8 місяців тому

    if that is the humming I can hear in the back ground that is noisy and annoying, that is noise pollution.

  • @timallen6025
    @timallen6025 8 місяців тому

    Nice run through , accuracy of layout and detail emphasised 👍

  • @lumbarsupport
    @lumbarsupport 8 місяців тому

    I have an 11.2kW Ecodan which was running for two years in Weather Compensation mode till Oct'23. Because it is a linear curve it never worked well because I always had to intervene once room temperature was reached by dialling down the curve by a few degrees to enable longer runs. Since the beginning of Oct'23 I switched to fully automatic (target room temp/auto adaptive) mode. After 3 months I'm amazed how much difference it has made - at least 15% better COP with like for like room/outside temps, and I have checked and double checked these results so many times now. The operation of the heat pump is so much better "managed", with more gentle startups (not so much initial power spiking), lower flow temps, longer run times, and better management of the effect of defrosting in really cold temps. You can clearly see in MelCloud how flow temps are modulated automatically as target room temp is achieved and then maintained for the longest possible runs at the lowest flow temps. Best news is that I don't have to intervene at all now - I can just leave it to do its thing all the time. Very impressed indeed with this superb piece of software from Mitsubishi.

    • @PeakTorque
      @PeakTorque 16 днів тому

      Great post and am trying to do the same. My 11.2 is on the standard weather comp albeit dialled down but overshoots quickly and has very short runs. How do you set the auto adapt mode for longer runs? I dont have melcloud online yet. Just the mobile stat.

    • @lumbarsupport
      @lumbarsupport 16 днів тому

      @@PeakTorque No setting changes required, just change the heating mode to "Room Temp (Auto Adapt)" - do you know how to do that? Do you have a Mitsubishi Ecodan wireless remote controller? "Room Temp (Auto Adapt)" mode won't work without that. This is the one I have ua-cam.com/video/hWPdFPWEpJc/v-deo.html but it looks like they have a newer version available now

    • @PeakTorque
      @PeakTorque 15 днів тому

      @@lumbarsupport yep thank you, got it! Should work with my setup. I wasn’t even aware that mode existed until i saw your comment. But trying it now cheers.

    • @lumbarsupport
      @lumbarsupport 15 днів тому

      @PeakTorque good to hear. Mitsubishi just installed a firmware update for me for free. It seems to make it work even better, with smoother longer runs at lower temps. You can apply online or give the Ecodan home owner tech helpline a call

  • @johnhunter4181
    @johnhunter4181 8 місяців тому

    Is there any reason why this (or any HT heat pump) couldn't be installed to directly replace the boiler on a y-plan system? It seems to me that it just needs a few feet of copper pipe to get from where the boiler is to the new HP and that would be about all that's needed. And for that price the BUS would cover the cost 100%. I really like the way it would match the black basalt of my new gravel drive too!

  • @m4vr1ck
    @m4vr1ck 9 місяців тому

    35p per kwh that's $0.45USD why is electricity so expensive in the UK I got mad when they raised it from $0.08 to $0.11 do you not have nuclear power

    • @barriedear5990
      @barriedear5990 5 місяців тому

      It has come down a bit since then, but the war in Ukraine caused prices to spike as gas supplies were cut.

    • @m23605
      @m23605 3 місяці тому

      Electricity price is generally is 3-4x the price of natural gas. Also, almost all energy tax is put on electricity and almost none on gas. The market has been rigged to encourage gas use which is piped directly to residential properties in most cities and towns.

    • @markrainford1219
      @markrainford1219 12 днів тому

      We bloody invented it! The same people who campaigned against nuclear weapons stifled the nuclear energy industry with their scare mongering. We have some, but only a fraction of what we really need. Personally I wish we were 100% nuclear.

  • @Rusteh100
    @Rusteh100 9 місяців тому

    Hey guys, please can you to advise whether the noise coming from my Ecodan is normal/close to normal? It's an 11.2kw model just been installed, and I don't know if there are grounds to complain or if this is normal when running a little harder. It was flowing at around 45c at time of the video, to heat the hot water tank. Video on my channel.

    • @dorewoodman
      @dorewoodman 9 місяців тому

      Hi, has the packaging and bolt travel spacers been removed in and around the compressor compartment?

    • @Rusteh100
      @Rusteh100 9 місяців тому

      I'd hope the installer would have done this, is it an easy check to do myself as the homeowner?

    • @dorewoodman
      @dorewoodman 9 місяців тому

      @@Rusteh100 should really be done to the installation company as you would need to isolate the electricity to the outdoor unit and remove the panel to the right of the fan as you look at the machine. There are some labels inside the machine where the compressor sits that instruct where the packaging sits, if the labels are still there, there is a good chance the packaging is too.

    • @Rusteh100
      @Rusteh100 9 місяців тому

      Thank you so much for your help, I shall contact them and see what they have to say.

    • @Rusteh100
      @Rusteh100 9 місяців тому

      You were 100% correct! New video showing a before and after have been uploaded if you care to hear the difference - wow!

  • @lawrencenathan1
    @lawrencenathan1 9 місяців тому

    Does the alpha function off grid, with the Enphase inverters then continuing to generate?

  • @undesignated3491
    @undesignated3491 9 місяців тому

    Looks like they be revising the anti noise legislation then, oh there's allowance for those. Typical British response, need a fixed constitution, there is a new law every week in this place .

  • @walterarmstrong3117
    @walterarmstrong3117 9 місяців тому

    Great video and a nice job. Did you use the IQ7+ or the 7A?