Nick's Engineering
Nick's Engineering
  • 4
  • 73 772
[HYSYS] How to make binary equilibrium plot & table
[HYSYS] How to make binary equilibrium plot & table
Переглядів: 2 038

Відео

[HYSYS] How to check water content/water dew point/Hydrocarbon dew point
Переглядів 5 тис.3 роки тому
How to indicate water dew point HYSYS? How to indicate water content in HYSYS? How to indicate HC dew point HYSYS? How to indicate Hydrocarbon content in HYSYS? How to make stream water saturated in HYSYS?
Pump NPSHa and NPSHr \\ pump hydraulic calculation
Переглядів 33 тис.3 роки тому
The pump hydraulic calculation is required for a process engineer to prepare pump data sheets, Control valve data sheet and to check pressure balance between each equipment. As a junior process engineer or university students, it is helpful for them to understand why they are doing those calculations. The purpose to carry out hydraulic calculation(especially for pump circuit) is to fill up the ...
Gas Dehydration and Glycol Regeneration Unit
Переглядів 34 тис.3 роки тому
Gas Dehydration and Glycol Regeneration Unit

КОМЕНТАРІ

  • @adil20601639
    @adil20601639 7 днів тому

    This is very detailed thanks for video im preparing for an interview

  • @sivaprasadg9927
    @sivaprasadg9927 12 днів тому

    Thanks. Could you explain more about Optimum temperature and PH of Lean TEG in the Absorber.

  • @rishabhlaxkar4035
    @rishabhlaxkar4035 22 дні тому

    If the temperature between gas and Teg in Contractor more than 15°C what will happen?

  • @obayzyuzuazor2637
    @obayzyuzuazor2637 Місяць тому

    Hi, how do you monitor and confirm the concentration of TEG both lean and rich?

  • @khanzahid3974
    @khanzahid3974 2 місяці тому

    Please i need this process flow sheet

  • @geraldraja3302
    @geraldraja3302 2 місяці тому

    Sir, where will be pressure drop take place. Kindly explain that. Because from dehydration column rich TEG 30°C 30 bar, after the control valve suddenly the pressure drop to 5bar how, from where it drop. Kindly please explain.

  • @vrbaac1641
    @vrbaac1641 2 місяці тому

    thank you for this educational video ^^

  • @rajamohandass.s9684
    @rajamohandass.s9684 4 місяці тому

    Superb 👍

  • @nursharmilla5325
    @nursharmilla5325 4 місяці тому

    Very good for learning!

  • @antoebenezar8273
    @antoebenezar8273 5 місяців тому

    i have a doubt, how fuel gas absorb water particles

  • @nimrasiddiq3461
    @nimrasiddiq3461 5 місяців тому

    Wonderful Sir .

  • @fadlohaddad4000
    @fadlohaddad4000 5 місяців тому

    Excelent! Thank you!

  • @Aru_wealth
    @Aru_wealth 6 місяців тому

    Nicely explained 🎉

  • @cchandran84
    @cchandran84 6 місяців тому

    Very informative video. Thanks Nick!

  • @raphaelragu
    @raphaelragu 7 місяців тому

    Hi Nick , thanks for your support and my. Question is wether we can add or subtract the friction loss in discharge, I think we can add friction loss in discharge....

  • @AriesSatriyo-INA-64
    @AriesSatriyo-INA-64 7 місяців тому

    What do we do IF we set 99.5 % wt of TEG to be used as an absorbent in the ABSORBER COLUMN? Would you happen to have any advice?

  • @mojtabaimanfar4267
    @mojtabaimanfar4267 7 місяців тому

    P discharge should be p statuc plus pressure drop

  • @ummifatihahlotffi2669
    @ummifatihahlotffi2669 7 місяців тому

    Hi nick. Appreciate if you could do this kind of explaination on other system as well (fuel gas system, compression system, gas dehydration system, etc)

  • @simbusvs2210
    @simbusvs2210 8 місяців тому

    You have said 1 bar is equal to 10.2m but in NPSHa calculation you are mentioning 10.2m for 0 bar

    • @shreyaskv4009
      @shreyaskv4009 7 місяців тому

      In NPSHa calculations he has taken 0barg so that means 1.01325 Bara = 10.2m WC

  • @firstlookmensworld7127
    @firstlookmensworld7127 8 місяців тому

    Very informative ❤❤❤

  • @alagusundaramkarthi6605
    @alagusundaramkarthi6605 8 місяців тому

    1atm is 0 barg is that correct

  • @077rdm
    @077rdm 9 місяців тому

    Addition of ∆P in Discharge pressure required😊

  • @rarkei_
    @rarkei_ 10 місяців тому

    Hi, Mr.Nick How to know if the pump requires minimum recirculation line? I don't understand clearly. I have this idea that this minimum recirculation line is related to turndown ratio advised by vendor. Could you explain clearly?

  • @abengineers920
    @abengineers920 10 місяців тому

    Thank you for this video

  • @NedumEze
    @NedumEze 10 місяців тому

    Great. Thanks Nick

  • @nagendrasingh840
    @nagendrasingh840 11 місяців тому

    A very good explanation. Thank you Nick.

  • @shabrazk5182
    @shabrazk5182 11 місяців тому

    nice biriyani 😀

  • @sourabhpatil4074
    @sourabhpatil4074 11 місяців тому

    Nicely explained.

  • @ARyan-og1wt
    @ARyan-og1wt 11 місяців тому

    Thank you Sir for your super teaching and informations in this video... You clarified many points in my mind in the Gas dehydration Unit

  • @waqarShah-q6l
    @waqarShah-q6l Рік тому

    u have whtassap numnber

  • @anglinh7497
    @anglinh7497 Рік тому

    Please help me explain where the Fuel gas flows when it absorbs water from the stripping column @all

  • @asnalishamsho2343
    @asnalishamsho2343 Рік тому

    Hi Nick. Thank you very much for your video. I have a question, if i put a pressure gauge at a suction side of the pump. If I substract the vapor pressure of the liquid from the reading of pressure gauge will I get NPSHA? Thank you again.

  • @ARyan-og1wt
    @ARyan-og1wt Рік тому

    Thank you for your thourough and excellent work

  • @theinhan3103
    @theinhan3103 Рік тому

    Thank you

  • @rathinamperiyaiah966
    @rathinamperiyaiah966 Рік тому

    clear and detailed lecture. thank you.

  • @raphaelragu
    @raphaelragu Рік тому

    Very nice explanation, thank you

  • @omowaleolaakerele3514
    @omowaleolaakerele3514 Рік тому

    I love the way you explained the whole process and broke it down to a layman's understanding. Wonderful, I must say! 👏👏👏

  • @MoussaMou-uj6oc
    @MoussaMou-uj6oc Рік тому

    Kim Jong-un

  • @raouf-tek
    @raouf-tek Рік тому

    Any video to explain gas dewpointing please

  • @DNTWREX
    @DNTWREX Рік тому

    Hi. If we have pressure gauges on an existing system on the discharge and the suction, we can just look at them right? We don't need to calculate, am I understanding it correctly?

  • @josephrajakumar6246
    @josephrajakumar6246 Рік тому

    Thank you brother. Very nice ❤❤❤

  • @josephrajakumar6246
    @josephrajakumar6246 Рік тому

    Please share more

  • @josephrajakumar6246
    @josephrajakumar6246 Рік тому

    Very nice explanation brother ❤

  • @darwinkishore
    @darwinkishore Рік тому

    Very nicely explained in a simple manner, I use it for training junior operators. I request if you can do one for gas sweetening.

  • @shanmugasundaramnarbavi1911

    The water can deliver at 50m Head from a pump, if we can use glycol instead of water in the same pump. Is any variation in head

    • @nicksengineering987
      @nicksengineering987 Рік тому

      The Head is the same assumed that the viscosity and pump speed are the same. of course, the denser fluid will affect pump efficiency due to hydraulic friction loss, motor power efficiency, etc.

  • @slengoslengaw8510
    @slengoslengaw8510 Рік тому

    Is NPSH calc applicable for closed loop systems? I only saw open loop examples and nothing for closed system

  • @slengoslengaw8510
    @slengoslengaw8510 Рік тому

    Hi all, anyone has an excel sheet for pump sizing they can share? Thanks

    • @nicksengineering987
      @nicksengineering987 Рік тому

      There are many sheets on the internet. You can easily find but you need to verify its calculations.

  • @khadimhussain4524
    @khadimhussain4524 Рік тому

    tnx good

  • @ahmedomerismail7730
    @ahmedomerismail7730 Рік тому

    Thanks

  • @nandakumar-oc7gy
    @nandakumar-oc7gy Рік тому

    Hi Mr. Nick !!! Greeting's. How come vessel operating under atm press became 10.2 bar G pressure in your calculation?