- 149
- 455 097
Able Distributors - Your HVAC Solutions Delivered!
United States
Приєднався 7 бер 2016
Your HVAC Solutions, Delivered!
On this channel you will find videos designed to help you sell and install HVAC systems in Chicagoland.
Videos are produced by Brian Daleske, lead Tech Support specialist at Able Distributors.
Spanish overdubs: ua-cam.com/channels/A3XlPfxGlOTcyx_ZNQyxhw.html
On this channel you will find videos designed to help you sell and install HVAC systems in Chicagoland.
Videos are produced by Brian Daleske, lead Tech Support specialist at Able Distributors.
Spanish overdubs: ua-cam.com/channels/A3XlPfxGlOTcyx_ZNQyxhw.html
Save Time and Perfect Your Installs with Legend Gas Press CSG Fittings! 💡
Our newest product is here to save you time and ensure your work looks flawless. Legend Gas Press CSG fittings are rated for indoor, outdoor, and underground use. In this video, we share proper procedures and tips to make your next job smooth and hassle-free.
shop.abledistributors.com/product-category/hydronics-and-steam/boiler-accessories/press-fittings/gas-press-fittings/
#HVAC #pipe #gaspipe #gaspipeline #furnace #poolheater
shop.abledistributors.com/product-category/hydronics-and-steam/boiler-accessories/press-fittings/gas-press-fittings/
#HVAC #pipe #gaspipe #gaspipeline #furnace #poolheater
Переглядів: 112
Відео
7 Reasons Legend Gas Press Fittings Will Revolutionize Your HVAC Installs!
Переглядів 98День тому
At Able Distributors, we’re dedicated to improving your workflow. With the Legend CSG gas press fittings, we’ve achieved just that-delivering faster, cleaner, and more professional installations without wasting time or materials. These fittings are designed for versatility, suitable for indoor, outdoor, and underground applications. shop.abledistributors.com/product-category/hydronics-and-steam...
New TRX Series 2 Boiler Setup Wizard! Easy Install with 115V & Low Voltage Connections!
Переглядів 164Місяць тому
shop.abledistributors.com/?s=trx series2&post_type=product&dgwt_wcas=1 In this video, we introduce the new Set Up Wizard, along with all 115V and low voltage connections. The updated TRX Series 2 retains the reliable heat exchanger, built-in pump, and three-way valve we know and love. Now, with the added Set Up Wizard, getting your new boiler up and running is easier than ever! #boiler #hvac #n...
Unboxing the NTI TRX Series 2: Everything You Need to Plan Your Job Right!"
Переглядів 247Місяць тому
shop.abledistributors.com/?s=trx-series2&post_type=product&dgwt_wcas=1 TRX-SERIES 2 Overview: ua-cam.com/video/UC0pe-c0c6E/v-deo.html This video covers what’s included in the box of the new NTI TRX Series Two, helping you plan your job accurately. The updated TRX Series Two has been significantly enhanced for easier functionality while retaining all the reliable features we've come to appreciat...
Meet the Upgraded TRX Boiler: The All-New NTI TRX Series 2 Boiler Overview!
Переглядів 177Місяць тому
shop.abledistributors.com/?s=trx-series2&post_type=product&dgwt_wcas=1 Unboxing video: ua-cam.com/video/DBtl4rfd73U/v-deo.html The TRX boiler from NTI has established itself as a powerhouse in the high-efficiency boiler market. NTI has retained all the beloved features while enhancing setup simplicity and control strategies. This video provides an overview of this impressive boiler. #hvac #heat...
Homeowner Tax credit 25C: Heat Pumps, Boilers, Water Heaters
Переглядів 1792 місяці тому
Espanol: ua-cam.com/video/MWQ6d0gIBIw/v-deo.html Polish: ua-cam.com/video/ayVxcx86Yiw/v-deo.html $3,200 per year maximum: $2,000 Heat Pump, $600 Boiler, $600 Tankless Water Heater up to 30% of the job cost.
Boost Sales with the 25C Federal Tax Credit: A Win for Homeowners & Contractors!
Переглядів 1632 місяці тому
Espanol: ua-cam.com/video/RJDWgKU3q3U/v-deo.html Polish: ua-cam.com/video/CPbj5v5juqg/v-deo.html In this video, I explain the 25C federal tax credit, how it works, and how you can leverage it to boost sales of high-efficiency products. It's a win-win for both homeowners and contractors-after all, who doesn’t love free money? #hvactech #hvactraining #hvac #hvacsystems #heatpumps #airconditioning...
Replace Saddle Valves with Ease: 1/4'' Water Line Using the Webstone Press Access Tee!
Переглядів 6682 місяці тому
Espanol: ua-cam.com/video/4macVhaQpnI/v-deo.html Polish: ua-cam.com/video/WIy-HA1cZFc/v-deo.html shop.abledistributors.com/34118/ball-valve-1-4-x-3-4-brass-compression-x-press-fitting/ A much better way to run a 1/4" water line to your humidifier or refrigerator is by using the Webstone Press Access Tee-it's quick, easy, secure, and hassle-free. #hvac #humidifier #webstone #saddlevalve
Protect Your Boiler: Why the TF1 Magnetic Filter is the Ultimate Defense Against Ferrous Debris
Переглядів 1332 місяці тому
Espanol: ua-cam.com/video/VBKAl5QrUGQ/v-deo.html Polish: ua-cam.com/video/xGy4P7ln5u4/v-deo.html shop.abledistributors.com/?s=tf1 omega&post_type=product&dgwt_wcas=1 Safeguarding your boiler and pumps from ferrous debris is crucial for extending their lifespan, and the TF1 is the top choice for the job. Fernox F1 & F3 Video: ua-cam.com/video/mLWxXABf-M8/v-deo.html Y-Strainer: shop.abledistribut...
Say Goodbye to Boiler Piping Headaches: Discover the Ultimate Primary/Secondary Solution!
Переглядів 5373 місяці тому
Espanol: ua-cam.com/video/W0cQcaOsl-E/v-deo.html Polish: ua-cam.com/video/KIt_QbzBvyY/v-deo.html shop.abledistributors.com/?s=closely spaced tee&post_type=product&dgwt_wcas=1 Installing an NTI high efficiency boiler using primary/secondary piping is the best method for optimal performance. While close tees have been used for decades, they are often installed incorrectly. The Webstone press clos...
Control More with Fewer Wires Using I.O. Controls Wireless Relay Plus!
Переглядів 3553 місяці тому
Espanol: ua-cam.com/video/EVjCx7-4oJw/v-deo.html Polish: ua-cam.com/video/9CyG7qY1eic/v-deo.html As heat pumps and two-stage air conditioning grow in popularity, wiring can become a challenge-but not anymore! With the I.O. HVAC Controls Wireless Relay, two wires can now manage four functions plus defrost if needed. Additionally, the Wireless Relay Plus, paired with the I.O. Controls Universal T...
Turn 2 Wires into 7 with I.O. Controls Universal Smart Wire Module!
Переглядів 3393 місяці тому
Espanol: ua-cam.com/video/K-q-FpxF7io/v-deo.html Polish: ua-cam.com/video/XNpec0VSYYU/v-deo.html Heat pumps and two-stage equipment are here to stay, offering enhanced comfort and efficiency. With the I.O. Controls Smart Wire Module, you can transform two wires into seven, making your two-stage AC or heat pump installation easier and compatible with any thermostat-no more excuses. Plus, the UT-...
10 Reasons to Love the Flair Puck Pro for Your Mini Split - Simple Yet Powerful
Переглядів 8565 місяців тому
Espanol: ua-cam.com/video/FueFUiw-1xY/v-deo.html Polish: ua-cam.com/video/JZkSlEcsfXo/v-deo.html I could easily list twenty reasons why I love the Flair Puck Pro, but I’ve narrowed it down to just ten. The most notable reason? It’s a simple solution, and simplicity is what I value most. shop.abledistributors.com/32794 Check out introduction video for Flair Puck Pro: ua-cam.com/video/Z4NqxbBzx1E...
HVAC Troubleshooting 101: How to Check an AC Capacitor (Back to Basics Video 1)
Переглядів 3265 місяців тому
Espanol: ua-cam.com/video/kVckLGWeqVM/v-deo.html Polish: ua-cam.com/video/GAc2 Yj1x8/v-deo.html Welcome to our Back to Basics video series! We’ll cover straightforward techniques for troubleshooting HVAC systems, tailored specifically for new technicians. Join us for the first video in this comprehensive series. #ac #hvac #heating #cooling #capacitor #troubleshooting
Smart Control Your Mini Split with Flair Puck Pro!
Переглядів 2,8 тис.5 місяців тому
Espanol: ua-cam.com/video/qq7bNRnLWas/v-deo.html Polish: ua-cam.com/video/aSpbi8qwGAI/v-deo.html Mini splits offer an exceptional solution for heating and cooling your home or office. The Puck Pro from Flair delivers efficient comfort right at your fingertips with its simple and elegant design. With the Flair Puck Pro, you can effortlessly control your Mini Split from your phone, computer, or s...
A2L Refrigerant Change Explained: What You Need to Know About Moving From R-410a
Переглядів 2,9 тис.6 місяців тому
A2L Refrigerant Change Explained: What You Need to Know About Moving From R-410a
Save Big on Marked Down Products! Explore the New Clearance Section on shop.abledistributors.com
Переглядів 1866 місяців тому
Save Big on Marked Down Products! Explore the New Clearance Section on shop.abledistributors.com
Why Using a Flush Cart is Essential for Proper Boiler Installations: step-by-step Instructions
Переглядів 3617 місяців тому
Why Using a Flush Cart is Essential for Proper Boiler Installations: step-by-step Instructions
Unboxing Rinnai's Latest Innovation: The RX Tankless Series Revealed!
Переглядів 6 тис.8 місяців тому
Unboxing Rinnai's Latest Innovation: The RX Tankless Series Revealed!
Tekmar 519 Radiant Thermostat Overview
Переглядів 8469 місяців тому
Tekmar 519 Radiant Thermostat Overview
The Able Cinematic Universe (ACU) Origin Story
Переглядів 1159 місяців тому
The Able Cinematic Universe (ACU) Origin Story
Mini Split/Central Split Condenser Stand - Great for Side Discharge Heat Pumps!
Переглядів 1 тис.9 місяців тому
Mini Split/Central Split Condenser Stand - Great for Side Discharge Heat Pumps!
Heat Pumps in 2024: Learn how to install and diagnose Napoleon and Bosch Heat Pumps
Переглядів 1,4 тис.9 місяців тому
Heat Pumps in 2024: Learn how to install and diagnose Napoleon and Bosch Heat Pumps
Napoleon NS18 Heat Pump: Installation and Set Up Guide
Переглядів 9519 місяців тому
Napoleon NS18 Heat Pump: Installation and Set Up Guide
NEW PRODUCT: Napoleon NS18 Heat Pump (HP + Coil Comed Rebates for 2024!)
Переглядів 4959 місяців тому
NEW PRODUCT: Napoleon NS18 Heat Pump (HP Coil Comed Rebates for 2024!)
NTI TFTN Boilers - Fault Codes and Troubleshooting
Переглядів 4,4 тис.9 місяців тому
NTI TFTN Boilers - Fault Codes and Troubleshooting
NTI TFTN Boilers - Installation and Set Up Guide
Переглядів 1,6 тис.9 місяців тому
NTI TFTN Boilers - Installation and Set Up Guide
Tekmar Boiler Controls Overview (Tekmar models 671,654,519,256,261,279)
Переглядів 1,2 тис.9 місяців тому
Tekmar Boiler Controls Overview (Tekmar models 671,654,519,256,261,279)
NEW PRODUCT: Napoleon NPFX Air Handler Overview
Переглядів 21410 місяців тому
NEW PRODUCT: Napoleon NPFX Air Handler Overview
Great video and educational!!
Does it turn on the electric heat coil on defrost
If u have 2 zones with different temperature needs. How does it decide what temperature to operate when both zones are calling
looking at Peerless 63-05 & burnham steam max around 240,000 btu which would you recommend
Thanks for this video. Grundfos needs to include your instructions into their installation manual.
I’ve installed over 100 of these, incredibly successful because it’s a great product and reading the manual does give you all of the information. But one thing I’ve never asked a question on, I don’t see the troubleshooting lining up with error code for example E5 or E2, Instead of indicates flashes, one flash, two flash, etc., and the book does not even talk about codes, such as FO or NL. Am I missing something? I feel like the manual was made for a different control board in regards to troubleshooting. The furnaces I install have the two segment LED and no flashing code. You simply look at the two segment LED but when you refer that over to the manual or the lower door on the furnace, it does not have the same codes. Can you elaborate on that?
Really appreciate it,Very useful videos.
Hi thanks for sharing this video, do you have a link to where we can purchanse the service valve kit? I bought a RX199I on amazon but the service valve kit was not included. Also are the vents just regular pvc pipes?
So would going from a 1 inch thick to a 4 or 5 inch thick filter increase airflow to my registers on the far side of my house?
Whats the best
Is this a product you have in your stores or would it be special ordered ?
we have this in all four of our branches ....in stock
Ya we use the cheap ones but doesnt this allow for a shit load of dust to be circulated throughout your house!? I know that we have to dust like every week, this being said I think I going to try the more expensive ones!
Can it be installed on the side not straight up
must be installed vertically,,
As someone that must do this themself, at the start of my learning journey thank you. Id gladly hire someone that actually shows up, shows up sober, shows up with at least a measuring tape before giving me a quote. Nope. I asked 2 contractors if they knew what manual D was, they did not. HVAC CONTRACTORS mind you.
there are very good HVAC contractors out there, it's sad you've had a bad experience , I hope you find the right contractor, good luck. Brian..
Any thoughts regarding my NTI Error Code ER3? Here's a brief video from my UA-cam channel showing the issue. ua-cam.com/video/w5e64CHCTeU/v-deo.htmlsi=7HizlIw-k7deBqL9
Er3 is often caused by a damaged Out door sensor or wire conneciton on the top of the boiler, or the water temperature sensor is failing. Your best bet is to get infront of the unit and talk with tech support.
@dqm9991 thank you...
Are these codes the same for trane furnaces?
Hi What about 3Ton YORK duct sizing? I started with 22x8 30ft +(\1 flat elbow 22x8) then reducing to 20x8 aprox 10ft then 16x8 another 10ft . Total duct work 57ft 3TON YORK GAS FURNACE + CONDENSER (cooling) Reason I keep 22x8 30ft & not reducing earlier 55ft total length , kind of LONG LINE? Would this be correct sizing? Thank you in advance ☺️
Thanks from an amateur who installed his own distributor system after the previous one corroded and then couldn't figure out why the floor heat wouldn't work - I had all the valves tightened in the clockwise direction!
Sir very nice conservation sir how to calculate duck size in diagram plan lay out sir plz videos up load our group Hanks from Abdul qadeer Pakistan
Im still a little confused by the smart circ built in. Do I need to add the recirculation pump?
With the RXP you dont need to. Just make sure to install the included bypass valve at the furthest faucet.
Just purchased, thanks!
can the 519 use outdoor temp to change the pwm timing?
Good stuff!
How do you buy that screwdriver?
Quick question. I watched a UA-cam video that says a quick fast rule on residential HVAC that 1cfm per square foot of home. Is that correct?
I have never heard that before, and I would disagree for a few reasons, where you live, Arizona compared to Chicago, different loads, design temps completely different. when we look at the smaller homes and the largest homes that we would treat with one system, that rule won't work, residential equipment stop at 2000 CFMs, but can handle a home over 2000 Square feet, and a 1200 Square foot home can be cooled with a two ton system at 800 CFM ( depending on region ) have the best day. Brian
On a 2.5 Ton unit top fed is one return from the bottom of the unit adequate? The airhandler is about 20 inches elevated so that it can be vented through its bottom. Thanks
Does Bosch make a 9000BTU with 115v like this? I only see 1 ton units out there.
in the 115v. they only have the 12,000 BTU, but the 220 volt version has a 9000 BTU, and running a 220 volt unit will cost you less on your electric bill than the 115 volt unit. hope this helped. Brian
Is the 0.5 restriction a 50% restriction, 0.5% restriction or some other value? Or put another way, is the difference between a .16 restriction and a .63 restriction significant? Would a 1.0 be a total restriction? Would we be better not filtering our AC at all and filtering with other room devices? Thanks for the video.
0.5 static is not 50% restriction , it doesn't work that way, it's how much back pressure and suction pressure ( supply and return ) is on the entire duct work system, the filter is only one part ( an important part to protect the equipment ) so we we look at the expensive 1" filters and see they add .6 static all by themselves, we know it's impossible to stay anywhere near the furnace manufactures hope of a .5 for all the ductwork, filter, registers, A-coil. hope this helps. Brian
Why they don’t have 4 ton condenser? Only 5 ton BoVB condenser
Have you tried installed a NS-18 with the Napoleon air handler? Curious how that AH is?
🌮pump?
Thanks for the information im a hvac contractor in Houston tx
I have all my current duck work information with drawings and I am looking for someone to design a new system. I’ve been told before the duck work system is undersized. I would love for you to design mine… any thoughts, ideas would be greatly appreciated.
White Steven Taylor Larry Harris Betty
Ive always used stainless steel washable, mesh and carbon filters, fact is air filters protect your equipment, there not for air purification, you can install a UV light in the return or the air handler, it works in hospitals, it should work for you. I can say for a fact, the last 2 units ive had, after 20 yrs of daily use, the coils were still in great shape, and ive never had to have my duct work cleaned, and still clean, but i clean my filters once a month. If your a germaphobe and you think high merv filters are helping you, be my guest, your paying more money for filters continually, and you will pay for expensive repairs you caused
Issues that I've found and a few solutions. 1. Size naturally makes it vulnerable to clogged sponge filter, which causes a slurping sound. Cleaning and regular maintenance helps prevent this. Don't clean your indoor coils while letting it drain into pump, also have found pan tablets clogs spnge filter. Keep extra filters on you. 2. Lack of required maintenance ( which could be way more often than people realize) can lead to a dirty water (float) sensor and unit will keep running. Everytime this has happened cleaning it has only fixed it once. The other times it just kept pumping regardless of cleaning. 3. Anti-Siphon valve ( lil green thing on yellow tube) is not made for length we think it can accommodate (Also it drips water a little but it doesnt seem to be an issue). This leads to slurping and sucking after pump has stopped. At first i thought it was a dirty filter, then dirty water sensor continuing pump after empty. Then realized there was a siphoning effect pulling water thru pump after it disengaged. I later found out, thru refco's competent tech support, that the pump tubing was ran too far vertically after too long horizontally. Basically cut downflow part of tube as short as possible to reduce siphoning effect. It worked. Would like to add, competent is a a huge compliment when i think of tech support. 4. Obviously make sure drain line doesn't sit flat against bottom, either cut at slant or notch it. All in all this lil pump opens up options as it has a very powerful pump for its size and it looks good. But always gravity drain if possible Hope this helps
Great explanation for static pressures 💯👍
Thank You, I'm glad you checked out one of my videos... more coming soon, Thanks..... Brian
thanks for the video...
Thanks for checking out our video, more Tekmar videos coming soon..... Scott
Are the valves free? Or you have to buy separately
the valves are not included and will need to be purchased.
Thank you!
Great video. I have a Goodman 4ton modulating 120,000 btu furnace. I have 3 cfm output on panel that range from 1670-2200 cfm. My furnace is located in basement, I have a 16’ trunk on left side of house and a 36’ trunk going to the right side of the house. When I start to build off the plenum does the first run on both side have to equal and be around that range of cfm or does the longest run has to start off being that cfm range?
Nice illustration
Thanks...I think ( you may be giving me $h!t about my artistic skills ) when I shoot these videos, I never script them out, I take two minutes to draw something and then I start recording, typically I do one take even if there's a flaw, for this 10 minute video, it takes me about 15minutes, I'm always by myself when I record, perfect was never my intension. I did see your unedited comment, and it's actually a good question, why would the "secondary" heat exchanger come before the primary one.... simple, if it was above the primary heat exchanger, the heat from the primary would re-heat the secondary. thanks for checking out my video, stay tuned more to come. Brian..
Yes but it will not catch anything this proved nothing
my intension wasn't to "prove" anything, I was merely pointing out that your furnace or air handler was not ever designed to "clean" the air in your home, the furnace filter was only to protect the equipment from debris,, and thats it. if you want to "clean" the air in your home, the correct way is to use something better than a 1 inch wide filter, there are options, I've listed the options before.... if you restrict the airflow beyond what the equipment manufactures rated it at, you'll lose air flow, your equipment will run hotter ( or colder ) and will not last as long and will not be as efficient, parts will break. there are better ways to filter the air in your home.
But what merv is it
Spun glass are awful look the same coming out as going in.
is it still quieter if the condenser is above the split duct?
Nice thorough detailed video. Can you use Blue tooth to activate recirculation pump? say you take random time showers.
More static pressure, less CFMs. Love it.
does it get power by out door? unit
can i use ty branches with my Duct ?