- 62
- 175 776
YANG QIU
Приєднався 27 сер 2014
How to upload the program from Omron NB HMI
How to upload the HMI program from Omron NB HMI
Переглядів: 662
Відео
How to set up CJ1W-EIP21 (CJ1W-ETN21) routing table using CX Integrator
Переглядів 3 тис.Рік тому
Actually, the settings will be exactly the same for CJ1/CS1 EIP21 ( Ethernet/IP module) and ETN21 ( FINS Ethernet module), for NS HMI or Scada FINS communications, it is necessary to set up the network number using this method.
Omron CP2E Quick Start in 10 mintues
Переглядів 4,5 тис.Рік тому
Omron CP2E Quick Start in 10 minutes, just quickly shows up the following: 1. Procedures to make a basic program 2. Global/local symbol, assign local symbols for programming. 3. CIO starting address ( input) from 0.00, output address from 100.00. 4. Set/Reset PLC instruction 5. TIM( BCD type) on-delay timer 6. Writing comments for your ladder program 7. Compile the program 8. Simulation 9. PLC ...
NX1P2/CP2E PLCs talk to Raspberry PI Node-Red via FINS Ethernet Part1 ( CP2E)
Переглядів 1,6 тис.Рік тому
NX1P2/CP2E PLCs talk to Raspberry PI Node-Red via FINS Ethernet Part1 ( CP2E)
Omron ACE 4.0/i4L-350 Robot Pick & Place Wizard Walkthrough and De-stacking demo programming
Переглядів 2,1 тис.2 роки тому
Omron ACE 4.0/i4L-350 Robot Pick & Place Wizard Walkthrough and De-stacking demo programming
Using SD Card to log the data from NJNX PLC, then go via FTP to transfer data to Microsoft Power BI
Переглядів 1,3 тис.2 роки тому
Using SD Card to log the data from NJNX PLC, then go via FTP to transfer data to Microsoft Power BI Example program download link ( Only for subscribers) drive.google.com/file/d/1FQJBAaKAAbnThRfzTn5xTa89MXKzOBCt/view?usp=sharing
How to log Omron 1S or G5 servo actual Torque/ Position/Speed
Переглядів 1,8 тис.2 роки тому
How to log Omron 1S or G5 servo actual Torque/ Position/Speed
Set up CP2E to control 3G3MX2 via MODBUS RTU serial communications
Переглядів 8 тис.3 роки тому
Set up CP2E talks to 3G3MX2 via MODBUS RTU serial communications Example program download link ( Only for subscribers) drive.google.com/drive/folders/1JWRdIeGJjrFuHYu-Kw7DupH_dfWVq7ab?usp=sharing
How to set up Omron CP2E PLC to communicate to NB HMI via Ethernet
Переглядів 18 тис.3 роки тому
NB-Designer Ver1.53 Download link ( Only for subscribers): drive.google.com/file/d/1qi7SAtsj0QjuzMp7nf269e81e025ZW2K/view?usp=sharing
NX102 to Microsoft SQL Database Training Video Part2 ( SQL Software installation)
Переглядів 4763 роки тому
This is supplementary information for NX102 to Microsoft SQL Database direct connection training video. This training video shows up the whole process of how to download & install Microsoft SQL Server 2019, of course, if you have installed the software already, you can definitely ignore this training video.
Omron NX102 SQL Client direct connection to Microsoft SQL Database server Part1
Переглядів 3,2 тис.3 роки тому
Omron NX102 SQL Client direct connection to Microsoft SQL Database server Part1
How to set up Ormon NJ501 PLC to communicate to CJ2 and CS1 PLC via Ethernet/IP for Data exchange
Переглядів 5943 роки тому
How to set up Ormon NJ501 PLC to communicate to CJ2 and CS1 PLC via Ethernet/IP for Data exchange
How to set up NTP Client on NX102 PLC, and synchronize time to internet NTP server
Переглядів 1,2 тис.3 роки тому
How to set up NTP Client on NX102 PLC, and synchronize time to internet NTP server
Utilize RoboDK to simulate TM12 Robot movement
Переглядів 1943 роки тому
Utilize RoboDK to simulate TM12 Robot movement
Omron Sysmac Studio vs Rockwell Studio 5000 (Part1)
Переглядів 1,3 тис.3 роки тому
Omron Sysmac Studio vs Rockwell Studio 5000 (Part1)
Set up NX1P2 to communicate to CP1L/CP2E via FINS Ethernet protocol
Переглядів 6 тис.3 роки тому
Set up NX1P2 to communicate to CP1L/CP2E via FINS Ethernet protocol
Omron HD1500 Autonomous Mobile Robot on-site trial
Переглядів 7583 роки тому
Omron HD1500 Autonomous Mobile Robot on-site trial
CP2E new FINS Ethernet function block
Переглядів 3,8 тис.3 роки тому
CP2E new FINS Ethernet function block
Using CS1W-ENT21 Socket service to implement the Modbus TCP comms
Переглядів 1,8 тис.3 роки тому
Using CS1W-ENT21 Socket service to implement the Modbus TCP comms
Use Omron NX102 to communicate to Proface HMI via Ethernet/IP
Переглядів 4,3 тис.3 роки тому
Use Omron NX102 to communicate to Proface HMI via Ethernet/IP
How to use Omron NX102 PLC to communicate to FQ2 Camera via Ethernet/IP network.
Переглядів 3,9 тис.3 роки тому
How to use Omron NX102 PLC to communicate to FQ2 Camera via Ethernet/IP network.
How to set up Datalink in between NX EIC202 EthernetIP coupler and PLC EIP master module
Переглядів 2,1 тис.4 роки тому
How to set up Datalink in between NX EIC202 EthernetIP coupler and PLC EIP master module
How to configure Ormon NX EIC202 EthernetIP coupler
Переглядів 4,4 тис.4 роки тому
How to configure Ormon NX EIC202 EthernetIP coupler
How to program Omron NS series HMI broken line graph
Переглядів 9954 роки тому
How to program Omron NS series HMI broken line graph
How to find out the unknown IP address for Omron PLC
Переглядів 9 тис.4 роки тому
How to find out the unknown IP address for Omron PLC
How to set up Omron LD Robot route for demonstration
Переглядів 5264 роки тому
How to set up Omron LD Robot route for demonstration
How to share data in between CJ2M PLC and V430 Code Reader Using Ethernet/IP
Переглядів 9504 роки тому
How to share data in between CJ2M PLC and V430 Code Reader Using Ethernet/IP
If "communication timeout", when download in tools HMI, please help me Sir 🙏🏼
i was subscribe, can you give me the manual?
Did you make part 2? I'm more interested in the NX1P2. I haven't had any luck using FINS with NX1P2 to a PC.
Thanks for sharing the video. I subscribed and sent a request for the code. Will this work using the FINS to a PC program?
tq for sharing library!!!
give me software link
Nice shoes, I can polish this for you too ;)
Estáticamente generalmente da bien , en condiciones normales en movimiento y con banda transportadora ahí vienen los problemas
Is it possible to simulate and check communication using only a cp2e plc and a leptop pc (nb designer) without using NB HMI hardware?
Unfortunate you can't do it. NB designer only supports to simulate the HMI itself program, does not support to simulate between PLC & HMI. Omron NA HMI supports it.
Hi and thank you for the tutorial. My OPC UA client can connect when Security mode is none. However, whenever I am trying to connect via Basic256Sha256 (Sign&Encrypt) the server does not recognize my client certificate in the rejected folder. I tried uploading the client certificate manually but didn't work. What can be the root cause for this?
I subscribed and requested the download, but never received access to the library 😔
mang terima kasih ya mang, akhirnya saya bisa konek ke nx102 mokasih, kagek dibelike seblak 1 porsi
Hi, i'm trying a new project for my degree, i'm having some problems connecting the PLC (Omron CP2E) to the NB7 screen. Would you mind helping me?
Thank you !
Thanks so good. That's very useful.
I want to try the library, thanks :)
please make a video for CJ1M cpu11 ETN with NS series HMI
I use an Omron CQM1H plc. But when I want to connect between the CX integrator and the PLC device, why isn't there a CQM1H device option?
Thanks !!
Hello Friend !!!! Here in my company's electrical workshop in Brazil we have an OMROM NX1P2 PLC. I'm using a network adapter because the notebook doesn't have an RJ 45 input, but USB. I can't find the CLP IP. My question? Does the USB/RJ 45 adapter "disrupt" IP identification? hugs and have a great week!!!!!
if you are using a USB adapter, which is different than using a PC in-built Network card if you can't find its IP address from Omron Comms utility, you can try using Wireshark software to do it, which will be similar to Omron's utility, but the advantage of Wireshark, you will be able to monitor the USB adapter network card specifically. Wireshark website:www.wireshark.org/
@@yangqiu472 Wireshark didnt worked out for me.I'll test again with your hints from this video.
sir.. i was subscribe.. give me permit to download sourcecode.. helpme please sir.. thankyou...
sir.. i was subscribe.. give me permit to download sourcecode.. helpme please sir.. thankyou...
Did you succeed in reading the holding register data from schneider power meter (PM2200)?
Thanks boss
Very nice performance sir
Hi Yang, i am trying to output "RX350h" to controllogix 5000 PLC. does it output in ASCii. how do i get the characters to send to the PLC from the OCR. thanks!
Thanks for sharing!
Grazie mille i suoi video in generale sono piuttosto molto curati!!! Bravo veramente
Come posso scaricare l'FB????
Hi , can we use fins as a TCP IP? To communicate external device
Thanks you very much but I cant download the sample due to dun have access
Hi, is it possible to reset the password after forgetting it to unlock the password for PLC OMRON NX102-9000?
You can rewrite the NX102 program, it is important to reset the password unless you knew the password and able to go online with NX102. Sysmac new PLC password encryption is much safer than C series PLCs.
@@artsphotographytomstudio1733 There is no other solution than rewriting the program Even if I have the program license code
Is this possible between a plc (Nj) and a data adquisition device software?
I guess you want to use data link to acquire data from a PC to an NJ PLC? If that is your application, the answer is yes or no. If you have Omron Sysmac gateway or CX-compolet installed, it is okay to do it, otherwise you can’t use Ethernet/IP data link on a PC.
@@yangqiu472 Yup thats the case I was afraid I cant directly. Thx
Hi, this vide is really helpful. I have a problem, why is the communication time between CIF11 and Inverter takes 5 second each instruction to send from PLC to Inverter, I know this because the Indicator Blinking LED on the CIF11 only blinks once every 5 seconds. Do you know why is that ?
Oi poderia me enviar o programa
where is part2 for NX1P2 ?
"Hi, I am Ankarnova, and I have subscribed to your UA-cam channel. Can I request access to download the software from the link you shared?"
P R O M O S M 💥
Sir possible to send link CX programmer 9.8 version
industrial.omron.eu/en/products/cx-one#software
Please same model PLC how to add additional IO Unit need one video please
Adding more IO units is quite straightforward, it is Unlike CJ/CS PLC, no need to set up an IO table, you just simply add them on, which is OK, For CP2E, you can add up 3 expansion units in max, and For PLC addressing, just keep counting up. For example, CP2E input starts from 0, 1, and the expansion unit starting address for inputs will be 2.00, all the way up, CP2E outputs start from 100.00 and 101.00, so the expansion unit starting address for outputs will start from 102.00. hope the above information will help you.
for info, please refer to ua-cam.com/video/fU0LBV-2a3Q/v-deo.htmlsi=sZUjojUdovic5LTu
why when I try to set connect on MQTT.fx it says "MqttSecurityException: Not authorized to connect" ? what step I do wrong?? can someone explain it?? \
Thank you very much for the video and sharing the library. It works!
Mr, i want try. that sample. thanks very much Mr YANG QIU
Hello...I have requested access to your files on google drive...Can you accept my request ?..thanks
Done, please check your email.
Good Day thank you for the tutorial. can i have access for the file ? , Thank You
hey friend, very inspiring video. btw, how if I have 1 NX1P2 and 12 CP2E-N PLCs. all connected into 1 network, does this fins system still can be applied or it has maximum plcs that can be connected ?
It depends on which protocol you are using, Normally it is FINS UDP, and it can be set up to 16 Devices, like you said, you have 12 CP2E PLCs, so it is fine for using FINS UDP to carry out the communications. Another way is to use MQTT, but for settings, quite complicated than FINS comms.
@@yangqiu472 thanks a lot
Thank you very much
감사합니다.....^^
thanks for the vedio ,,very helpfull can you share the cx drive !!!!!! please
i need cx-drvie to program my vfd , please provide to me