Electrodell Installations
Приєднався 14 січ 2020
Відео
Mount Snowdon Llanberis Path
Переглядів 1614 роки тому
Walking the Llanberis Path of Mount Snowdon on Sat 22 February 2020
Mount Snowdon Watkins Path
Переглядів 574 роки тому
This was a trip to Mount Snowdon on the 21 February 2020. The weather at the top was bad. Visibility wasn’t great and the wind at over 70 mph. With the wind speed at times it felt -11 degrees apparently
Mikes tractors
Переглядів 344 роки тому
The black tractor is why my uncle Mike made 40 years ago and the red one is the last one he made. 12 in total and still running. This was the first time Noah had seen them
Outside garden lights insulation resistance fault finding
Переглядів 3,4 тис.4 роки тому
Badly installed garden lights. RCD kept tripping due to earth fault. Carried out insulation resistance at each fitting until fault finally cleared. Fault due to poor damp connections.
Badly damaged cables due to mice. Metal trunking IP ratings
Переглядів 764 роки тому
Call out to a farm building where mice have been able to get into the metal trunking and have damaged all the cables. This is why IP ratings are so important.
Safety isolating transformer electrical separation
Переглядів 1974 роки тому
Demonstration to show if you drop a shaver socket into a sink of water you won’t receive an electric shock due to the electrical separation from earth
13a socket install . Dewalt 18v multi-tool. Zs 3 lead low testing
Переглядів 844 роки тому
Installing a 13a socket, going live and earth fault loop impedance testing (Zs) 3 lead low
PIR replacement for Led floodlight
Переглядів 1034 роки тому
Replacement of a Pir and installing a switch in the switch line to turn light off. Notice the Pir remains live so does not reset
Confirming polarity and a loose earth connection
Переглядів 384 роки тому
Confirming polarity between all three conductors and finding a poor earth connection
Wyler 100mA time delayed RCD testing
Переглядів 8 тис.4 роки тому
Testing a 100mA s curve RCD at 1x, 5x and ramp are both 0 and 180 degrees
Ford Corsair classic car
Переглядів 3,5 тис.4 роки тому
First time it’s seen daylight in nearly 40 years. Awkward but if reversing the trailer too.
Change over 3 phase 400 volt contactor
Переглядів 2664 роки тому
The main contactor was making a very loud buzzing noise, possibly due to dirt within. Swapped over with the back up generator contactor as a temporary measure.
To much wind noise I can’t what you’re talking about.
Lovely example of exceptional talent and experience from farther and son .
Great video, just about to do the same and this has really helped!
It's great to see a two door Corsair there can't be many of these
Bit windy!
Wow that car is so rare a two door Corsair
Thanks for making this video, very helpful.
Great video. Glad to see all the leaks of water thought it was just me who had that problem 😅 what was the name of the sealer you were using.
Thanks useful video 👍
Great informative video. Thank you
It was like watching laurel and hardy lol.
Love the training for the new apprentice! Good to start then young. Great video - very clear explanations. Thanks
Love the top of keeping halogens in place to dry out the circuits - great video. Thanks
What's happened to the corsair
I'd be interested in buying it
Great video and great piece of educational equipment you have made there 👍
Great work my friend 👍
I use a MFT1711. It does this 30 second delay like in this video. There is no explanation in the manual for the S type tests. I know it's for a time delay but can't find any explanation as to the reason it waits for 30 seconds until it starts the test.
You can change the setting mate. I turned mine on to auto so it does it Asoon as it picks up voltage
Did you end up doing the remedial work? Lucky mice.
Awesome views !!! Makes you feel humble especially Scotland's highlands
Interesting video, and quite handy as just been discussing RCDs and testing for an upcoming exam 👍
Donation made 👍. Proud of you mate
GSH Electrical thanks Gaz. Some of the footage was so bad cause of the weather but some came out ok
Great work mate 👍
The 5x test MUST only be carried out on RCDs with a trip ratings up to 30mA. The 5x test must not be carried out on RCDs with a trip rating of 100mA or greater.
Mark Gilder appendix 3 in BS7671 shows the results that must be achieved for a 5 times test on a 100mA RCD (and the 300 and 500) table 3A. But think depending if it's for fault protection, or additional protection directs which result you are interested in keeping for paper work, I would have thought.
Mark Gilder why must it not? Just interested in knowing
Great practical demonstration of fault finding and some examples of remedial works 👍
👍
What constitutes as earth?
kyle mckay depending on the earthing arrangement, the earth is simply a direct connection to it. On a safety isolating transformer there is no direct connection, therefore no fault path back, therefore no electric shock
Yes Matt 👊🏼👊🏼
That looks a very interesting remedial job when it comes to carrying out the repair
Good video and good to see it demonstrated (from a safe distance for me 😉). It's a shame they can't put a similar kind of 1:1 isolating transformer at the at the service head of and installation to separate it, (but maybe am talking rubbish as it might not work with parallel paths through older bonding)
David Roche it’s always been a thought but costing had to be considered plus ADS works well
What a cute cub! <3
Great to see some on site real world videos, keep them coming 👍