Replacement Ac transformer 430v /230v melted and shorted.
Replacement Ac transformer 430v /230v melted and shorted.
Переглядів: 105
Відео
Chiller annual shut down Tube cleaning progress.....
Переглядів 1594 місяці тому
Chiller annual shut down Tube cleaning progress.....
Daikin FCU blower bearing dismantle and installed new bearing replacement work...
Переглядів 1324 місяці тому
@plushvac please subscribe my channel 🙏 Daikin chilled water FCU blower bearing dismantle and installed new bearing replacement work... thanks for see my video 🙏 ua-cam.com/play/PL5VXp30dIypbHGJtOtM8vencsiMDiaVLW.html ua-cam.com/play/PL5VXp30dIypZjIhuwxukp2skuJp8lBOrG.html ua-cam.com/play/PL5VXp30dIypY0U19Fn4JMdfNljFbfhEcU.html
Daikin inverter unit error code -E7
Переглядів 4214 місяці тому
@plushvac please subscribe my channel 🙏 Daikin inverter unit error code -E7 in this video condenser unit motor wire burn and error code E7. replaced motor and test run system. thanks for see my video 🙏 ua-cam.com/play/PL5VXp30dIypbHGJtOtM8vencsiMDiaVLW.html ua-cam.com/play/PL5VXp30dIypZjIhuwxukp2skuJp8lBOrG.html ua-cam.com/play/PL5VXp30dIypY0U19Fn4JMdfNljFbfhEcU.html
error code - E59 Mitsubishi unit VRF check and troubleshooting ...
Переглядів 5044 місяці тому
Mitsubishi unit VRF error code - E59 check and troubleshooting....
Daikin fan coil unit chemical clean .
Переглядів 334Рік тому
@plushvac please subscribe my channel 🙏 Brand - Daikin Daikin fan coil unit chemical clean . step by step we Dismental the fcu and separate all the part , chemical clean the coil ,again put back the system normal thanks for see my video 🙏 ua-cam.com/play/PL5VXp30dIypbHGJtOtM8vencsiMDiaVLW.html ua-cam.com/play/PL5VXp30dIypZjIhuwxukp2skuJp8lBOrG.html ua-cam.com/play/PL5VXp30dIypY0U19Fn4JMdfNljFbf...
DAIKIN VRV 3 error code - LC
Переглядів 10 тис.Рік тому
Please subscribe my channel 🙏 In this video DAIKIN VRV 3 error code - LC thermostat blinking. Error code - LC mean Mainly pcb board problem that means main pcb board , inverter pcb, fan board and noise filter board problem in this case Daikin VRV 3 check and found condenser unit inverter board pcb wire burn and faulty. In this video briefly show you how to replace inverter pcb board. because of...
Mitsubishi fcu water leak. clean and rectify the leaking issue temporarily.
Переглядів 450Рік тому
Mitsubishi fcu water leak. clean and rectify the leaking issue temporarily.
Daikin error code - J5,J6,J7,J8,J9. For replace thermistor for condenser unit.
Переглядів 8 тис.Рік тому
Daikin error code - J5,J6,J7,J8,J9. For replace thermistor for condenser unit.
Daikin error code - E7. Main pcb board Burn. so check compressor winding resistance and Continuity
Переглядів 746Рік тому
Daikin error code - E7. Main pcb board Burn. so check compressor winding resistance and Continuity
Daikin wired thermostat BRC2E61 to find room, return air, liquid,gas temperature and error code
Переглядів 6 тис.Рік тому
Daikin wired thermostat BRC2E61 to find room, return air, liquid,gas temperature and error code
TOSHIBA UNIT VRF ERROR CODE - P26. COMPRESSOR SHORTED,BYPASS COMPRESSOR,SYSTEM RUN EMERGENCY MODE.
Переглядів 10 тис.Рік тому
TOSHIBA UNIT VRF ERROR CODE - P26. COMPRESSOR SHORTED,BYPASS COMPRESSOR,SYSTEM RUN EMERGENCY MODE.
ON coil temperature and OFF Coil temperature.
Переглядів 4,4 тис.Рік тому
ON coil temperature and OFF Coil temperature.
Daikin new vrv unit for old VRV III condenser unit.
Переглядів 212Рік тому
Daikin new vrv unit for old VRV III condenser unit.
Daikin error code - E3.CU Heat exchanger Badly choked.
Переглядів 1,1 тис.Рік тому
Daikin error code - E3.CU Heat exchanger Badly choked.
Mitsubishi VRF FCU not cool, check and found main pcb board problem
Переглядів 4,1 тис.Рік тому
Mitsubishi VRF FCU not cool, check and found main pcb board problem
Calculate BTU for new aircon to my room and living room.
Переглядів 164Рік тому
Calculate BTU for new aircon to my room and living room.
Megger insulation resistance testing for 3 phase induction motor
Переглядів 67Рік тому
Megger insulation resistance testing for 3 phase induction motor
(YORK CHILLER) Brief tell about York Air-cool chiller.
Переглядів 75Рік тому
(YORK CHILLER) Brief tell about York Air-cool chiller.
DAIKIN Installed VRV A new condenser unit for OLD VRV 3 FCU.
Переглядів 222Рік тому
DAIKIN Installed VRV A new condenser unit for OLD VRV 3 FCU.
Daikin Air-cool chiller alarm EXV MODULE PROBLEM.
Переглядів 1,4 тис.Рік тому
Daikin Air-cool chiller alarm EXV MODULE PROBLEM.
Daikin error code - E5 inverter pcb board compressor problem emergency mode run standard compressor
Переглядів 15 тис.Рік тому
Daikin error code - E5 inverter pcb board compressor problem emergency mode run standard compressor
check with AHU VSD , AHU actuator work or not.
Переглядів 685Рік тому
check with AHU VSD , AHU actuator work or not.
Bhai explain karna nhi aata h to mat kiya karo
What is this
Isko repair kar shkte hai kya
Cmner tu nak cek off temperature
What will the reading in the clam meters indicate if the compressor is defective 10 Hp vrv
Ok
Doha ?
Hindi me hota to samajh aata Sir me video bana sakate hai kya
You should eliminate the corrosion from impeler
How much cost for eexv driver bro ????
sorry bro,I don't know cost of eexv,
Why wouldn't you want the low side to drop when the compressor is engaged? 80 psi seems high though, isn't it ? (I don't know commercial HVAC pressures)
hi guys , condenser unit main breaker trip, after turn on the breaker, but condenser unit cannot start, system stable time pressure ok, so we top up gas R410 , after few minutes system can start. but pressure very faster drop to blew 80 psi. here suspect gas leak from system. after top up gas , condenser unit back to normal.pressure and amps is ok.but need to find the gas leak.
It is harmful error
It could be the pcb not the fan... 😂😂😢
Sir how much k oms
Abe hindi bol le angreg😊
So, inverted pcb board kompressor is broken ??
Weaaaa😅
After bypass again how back to normal mode?
Ur from ??
What cause this eev board not working can you please explain it
Eexv board became faulty, eexv valve not work. So totally chiller not work.
@@plushvac so we can't repair the eev board?
I don't know can repair or not, we replaced new eexv board.
Zabar dast bhai good knowledge
Very good 💯
Thanks
What to do first test running or auto gas charging
VRV first u test run time. Have Error code u3-10. Need to run auto gas charging. After run testode.
Super brother
Thank you
Merhaba Test modunu nasil calistirabilirim
Kepala nenek kau fcu
Bro can you know pcb testing
Hlo
I ask questions..wat is model# that unit sir? Can u show?.
VRV 3 rxq10pay
❤❤❤❤❤❤
Thanks
Excellent work
Thanks
Hello , i need paper please (02:42)
Sorry,I no have any paper
Pepper will do instead.
Sorry I no have
what does fault code E0 mean? Please explain
Outdoor unit need to check one by one
Please check compressor and pcb board
Bhai Hindi me total error code ka solution bataye
VRV 3 Multi outdoor units emergency setting plz share...
Ohm out the eev, check that both the plug and the eev are properly seated and not grounding out. Otherwise, leave the breaker off for 15-20 minutes (don't rush it, believe me!) Make sure everything is tight and turn it back on.
Hi, my ahu actuator also same problem (automatically open close), but my site don't have bms or vfd system. operate by tharmosted. What is the problem about this issue? Now how I can check for this problem? Plz tell me
Qual seria o defeito , válvula de expansão?
how to lock the remote
Did you got any solutions.
Bagaimana cara ngatasinnya
San nkakabile ng pyesa
Fan pcb ya fan moter
Inverter pcb
what is the solution?
Nice 😎
Thanks
ua-cam.com/video/Q6HlOzAjRJQ/v-deo.html
Negro capacitor
Hello Bro
Hi bro
@@plushvac Bro you working in Singapore?
@@acmv6783 no
Toshiba vrf me indoor error ko kaise bypass karte hai outdoor unit se
I don't know Hindi language
Kya aapka no. Mil sakta h aap kis city se ho