Machine and replace a new shaft for 800HP electric motor
ELECTRIC MOTOR
-REMOVE ORIGINAL SHAFT;
-BORE OUT SHAFT TO PREVENT DAMAGE TO ROTOR SPYDER;
-SUPPLY AND INSTALL NEW SHAFT USING 4140 HTSR (HEAT TREATED);
-SHAFT DIMENSION FRB 4140 STEEL SHAFT 11" X 92" (FULL ROUND BAR); -CUT TWO KEYWAYS IN NEW SHAFT AS PER DRAWING;
-GRIND BEARING JOURNALS AND OUTPUT SHAFT;
-CHECK RUNOUTS ON NEW SHAFT AND ROTOR;
-INSTALL NEW SHAFT TO ROTOR.
THANK OUR GREAT MAGNETO TEAM!
Epic Trailer by LesFM | lesfm.net/ Music promoted by www.chosic.com/free-music/all/ Creative Commons CC BY 3.0 creativecommons.org/licenses/by/3.0/
Переглядів: 407

Відео

REWIND WESTINGHOUSE 1800HP 2300V ELECTRIC MOTOR
Переглядів 1,5 тис.2 роки тому
- DISMANTLE, CLEAN AND INSPECT ALL PARTS; - MEASURE ALL HOUSINGS AND JOURNALS TO ENSURE PROPER FITS; - DYNAMICALLY BALANCE THE ROTOR AND ACCESSORIES TO ISO 1940 G1.0 GRADE; - REMOVAL OF THE DEFECTIVE WINDING AND TEST THE STATOR CORE FOR LOSSES AND EFFICIENCY; - PERFORM ROTOR CORELOSS TEST; - REPAIR HOT SPOT ON ROTOR LAMINATION; - CONFIRM THE STATOR WINDING DATA USING THE EASA A.C. MOTOR VERIFIC...
300HP ARMATURE REWIND | REWIND, RE-BAND, TIG WELD AND V.P.I ARMATURE
Переглядів 1,8 тис.2 роки тому
300HP DC 240V 508ATZ GE MOTOR - SUPPLY ONE SET OF FORMED ARMATURE COILS - INSULATE ARMATURE SLOTS AND COIL SUPPORTS - REWIND ARMATURE - RE-BAND ARMATURE HEADS AND CORE - TIG WELD ARMATURE - PERFORM 2 X VPI CYCLES AND CURE THANK TO MAGNETO TEAM! For more information of Armature rewind, please visit Magneto's website www.magnetoelectric.com/ Heroism by MaxKoMusic | maxkomusic.com/ Music promoted ...
300HP ARMATURE REWIND | STRIPPING AND COMMUTATOR INSTALLATION
Переглядів 3,9 тис.2 роки тому
300HP DC 240V 508ATZ GE MOTOR COMMUTATOR REPLACEMENT & ARMATURE REWIND STEP ONE STRIPPING AND COMMUTATOR REPLACEMENT NEXT STEPS, ARMATURE REWIND COMING SOON.. THANK TO MAGNETO TEAM! Inspiring Optimistic Upbeat Energetic Guitar Rhythm by Free Music | soundcloud.com/fm_freemusic Music promoted by www.chosic.com/free-music/all/ Creative Commons Attribution 3.0 Unported License creativecommons.org/...
Vacuum Pressure Impregnation | VPI full process for 1000HP 237RPM stator
Переглядів 1,5 тис.2 роки тому
VPI stands for Vacuum Pressure Impregnation. It is a process by which a fully wound rotor or stator is completely submerged in resin. Through a combination of dry and wet vacuum and pressure cycles, the resin is assimilated throughout the insulation system. A VPI insulation system provides an optimal shield for windings in harsh environments while also improving the mechanical stiffness of the ...
30-year experienced mechanic teaches you how to dynamically balance rotor and change new bearings
Переглядів 2,4 тис.2 роки тому
DAYTON 5HP 3495RPM 184TCHZ 208-230/460V MODEL#G67418 CUSTOMER REQUESTS TO REWIND MOTOR TO 575V; THIS VIDEO SHOWS PARTIAL REWIND OVERHAUL PROCESS; FULL PROCESS OF DYNAMICALLY BALANCE ROTOR AND FAN TO ISO 1940 G1.0 GRADE; BEARING CHANGE; SNAP RING INSTALLATION. BEARING 6205ZZC3/2A BEARING 6206ZZC3/2A THANKS TO MAGNETO TEAM!
auto rewind machine full video
Переглядів 7163 роки тому
auto rewind machine setup and production video
Auto winding machine
Переглядів 1873 роки тому
High efficient auto winding machine
Electric motor repair overhaul | 11kw 400v 105HZ 6500rpm | Rush delivery | Elektror Motor
Переглядів 8 тис.3 роки тому
Electric motor repair overhaul | 11kw 400v 105HZ 6500rpm | Rush delivery 0:00 PERFORM ALL INCOMING ELECTRICAL & MECHANICAL TESTS; DISMANTLE CLEAN AND INSPECT ALL PARTS. 01:08 MEASURE BEARING HOUSINGS AND SHAFT JOURNALS; 01:46 RESLEEVE NDE HOUSING 02:14 DYNAMICALLY BALANCE ROTOR AND FAN TO ISO 1940 G1.0 GRADE FOR 6000RPM; 02:50 INSTALL NEW BEARINGS; REASSEMBLE AND PERFORM ALL OUT GOING TESTS; Th...
STRIP STATOR - GE 5600HP 4000V MOTOR
Переглядів 5 тис.3 роки тому
STRIP STATOR - GE 5600HP 4000V MOTOR PUSH STATOR INTO LARGE OVEN FOR STRIPPING
MOTOR WITH HIGH TEMPERATURE AT DE HOUSING AND SHAFT WITH INFRARED THERMOGRAPHY
Переглядів 2503 роки тому
MOTOR WITH HIGH TEMPERATURE AT DE HOUSING AND SHAFT WITH INFRARED THERMOGRAPHYEXCESSIVE GREASE CAN CAUSE THIS PROBLEM
Induction motor bearing replacement | Reliance Motor 900HP 4KV ODP RPM 1782 FRAME 5840 Overhaul
Переглядів 21 тис.3 роки тому
Induction motor bearing replacement | Reliance Motor 900HP 4KV ODP RPM 1782 FRAME 5840 Overhaul 22220EAW33C3 NTN bearing -MEASURE ALL INCOMING MECHANICAL MEASUREMENTS AS RECEIVED; -DISMANTLE CLEAN AND INSPECT ALL PARTS -MEASURE DE AND NDE BEARING HOUSINGS AND JOURNALS; -STEAM CLEAN AND OVEN DRY ROTOR AND STATOR; -ELECTRICALLY TEST STATOR AFTER OVEN DRY; -OVERHAUL MOTOR. -DYNAMICALLY BALANCE ROT...
Dynamic balancing rotor & impeller of 250HP motor | Level G1.0
Переглядів 26 тис.3 роки тому
Dynamic balancing rotor & impeller of 250HP motor | Level G1.0 Dynamic balancing definition: “Dynamic balancing is a way of balancing machines by rotating parts quickly and measuring the imbalance using electronic equipment. The imbalance measured can then be corrected by adding or subtracting weight from the rotating parts until the vibration is reduced.” Thank to the team of Magneto Electric
Motor Rewind | 300HP DC motor rewind overhaul | Professional Canada motor repair plant
Переглядів 31 тис.3 роки тому
Motor Rewind | 300HP DC motor rewind overhaul | Professional Canada motor repair plant The 300HP DC motor came in with grounded field coil. After full dismantle and evaluation, this motor is supposed to be rewound and overhauled. Overhaul includes deep cleaning, bearing replacement and dynamic balancing. Re-sleeving Drive End Housing and undercutting commutator are also required. Thank to the g...

КОМЕНТАРІ

  • @jaouadyassine1
    @jaouadyassine1 6 місяців тому

    good job

  • @nestoralos1641
    @nestoralos1641 7 місяців тому

    Very amazing , I'm a armature rewinder from phillipines can I apply with you sir

  • @user-cl3tu5qm9m
    @user-cl3tu5qm9m 9 місяців тому

    Can you become a millionaire in this business?🤔

  • @lorenzobeckmann3736
    @lorenzobeckmann3736 11 місяців тому

    altogether nice job except: if you drop the fields out of the frame without noting which pole pieces and which shims, then after assembly, with clean armature lam, reshim fields with feeler gauge gives equal gap

  • @a-dcruz5256
    @a-dcruz5256 Рік тому

    Hellow sir! I am electrical technology student here in Philippines. I just wanna ask is there any chance I could apply in your company as tranee and at the same time employee. Thank you for your response ❤.

  • @mohammednisar4307
    @mohammednisar4307 Рік тому

    Good job ❤️

  • @YSR.0
    @YSR.0 Рік тому

    Kindly send me your contact no

  • @MR.RICKVWYBRAIN
    @MR.RICKVWYBRAIN Рік тому

    🚩🔱🇮🇳🔥⚔️🛡

  • @Fgoblin2014
    @Fgoblin2014 2 роки тому

    Have you guys ever had any trouble power washing amatures? Ive heard some places try to not do so because of potentially washing wet carbon onto the back of the comm.

    • @ontarioelectricmotorman7309
      @ontarioelectricmotorman7309 2 роки тому

      Hello Taylor. Before we wash any armature we will blow out any excess carbon or contamination with compressed air. Once all the debris has been blown out we will steam clean the armature and put it in our oven for dry out. With older armatures we will wash it from a bit of a distance so we do not damage the insulation.

  • @samschannel531
    @samschannel531 2 роки тому

    105Hz is quite an oddball, any idea what this was used for?

  • @nikolayhristov8493
    @nikolayhristov8493 2 роки тому

    Never stand close to operating EMF device, it's not healthy for you. Safety first.

  • @twintwo1429
    @twintwo1429 2 роки тому

    Was the overhung impeller already balanced or taken into consideration?

    • @ontarioelectricmotorman7309
      @ontarioelectricmotorman7309 2 роки тому

      For this case, we balanced the impeller first because it was too much out of balance. We made a new shaft for the impeller balancing, after that we put the impeller on the rotor and balance again. In most of the cases, you can balance them together.

    • @twintwo1429
      @twintwo1429 2 роки тому

      @@ontarioelectricmotorman7309 good practices. In our shop, we found that up to 20% of new impellers are not balanced to G-1 SPECS. same for various other attachments also. We had a customer complain of excessive vibration in a hazelton pump we rebuilt, less impeller. They installed a worn impeller with improper gap at wear ring. Go figure!!!.

    • @ontarioelectricmotorman7309
      @ontarioelectricmotorman7309 2 роки тому

      @@twintwo1429 yes, we would need the impeller, pulley or coupling sent in with the motor, unless it is a small unit.

    • @twintwo1429
      @twintwo1429 2 роки тому

      @@ontarioelectricmotorman7309 👍

  • @msaeed8971
    @msaeed8971 2 роки тому

    Good job

  • @paramaguruu8073
    @paramaguruu8073 2 роки тому

    👌

  • @benimaklete
    @benimaklete 2 роки тому

    Nice

  • @alexandergarcia381
    @alexandergarcia381 2 роки тому

    Saludos, como saber a cuantas RPM debo ajustar la realizacion de las diferentes pruebas en funcion del rotor, existe algo de guia? De antemano gracias.

    • @ontarioelectricmotorman7309
      @ontarioelectricmotorman7309 2 роки тому

      Por lo general, la máquina equilibradora recomienda la velocidad de equilibrado al menos 1/3 de la velocidad de funcionamiento. Por ejemplo, la velocidad nominal del motor es de 3600 rpm, elegiría 1200 rpm para la velocidad de equilibrio. Sin embargo, cuanto mayor sea la velocidad que elija, mejor, pero no menor que 1/3.

    • @alexandergarcia381
      @alexandergarcia381 2 роки тому

      @@ontarioelectricmotorman7309 Excelente! Realmente agradecido!

    • @alexandergarcia381
      @alexandergarcia381 2 роки тому

      Es decir que para un motor de 1200 RPM, con 400 rpm alcanzaría o sería muy pocas RPM para balancear en este tipo de máquinas balanceadoras.?

    • @ontarioelectricmotorman7309
      @ontarioelectricmotorman7309 2 роки тому

      @@alexandergarcia381 Sí, tiene usted razón.

    • @exzyond
      @exzyond 2 роки тому

      @@ontarioelectricmotorman7309 so what if i choose less than 1/3 the speed ? like motor rated speed is 3000rpm but i use 400rpm for balance speed

  • @majedaelectricworkshop
    @majedaelectricworkshop 2 роки тому

    Very good work and very nice workshop

  • @bakilsorory3516
    @bakilsorory3516 2 роки тому

    👍👍❤

  • @liju101
    @liju101 2 роки тому

    What is this blue varnish used here?

  • @jitendrasutar8726
    @jitendrasutar8726 2 роки тому

    🌹🌹🌹🌹👌👌👌❤❤❤

  • @ALIK1519
    @ALIK1519 2 роки тому

    ua-cam.com/channels/6svdIAVPJWd3lXXROWdVyQ.html

  • @marcioadrianodossantossant835
    @marcioadrianodossantossant835 2 роки тому

    TER E QUIPAMENTOS E UMA EQUIPE BEM TRENADA TRABALHANDO EM SINTONIA É LIMDO DE SI VER M.A.S GRAMADO RS EL BRAZIL

  • @ALIK1519
    @ALIK1519 3 роки тому

    Good job ua-cam.com/channels/6svdIAVPJWd3lXXROWdVyQ.html

  • @ALIK1519
    @ALIK1519 3 роки тому

    ua-cam.com/channels/6svdIAVPJWd3lXXROWdVyQ.html

  • @ALIK1519
    @ALIK1519 3 роки тому

    ua-cam.com/channels/6svdIAVPJWd3lXXROWdVyQ.html

    • @tukangrewinding
      @tukangrewinding 2 роки тому

      Rewinding ua-cam.com/video/OX8a6USb0ZU/v-deo.html

  • @angelpaul8678
    @angelpaul8678 3 роки тому

    Nice one!!! Looking forward to more uploads. You should go and take a look at Promosm!! It’s a handy tool to help grow your channel!

  • @MenzelMotors
    @MenzelMotors 3 роки тому

    we just want to say hello

  • @stevenzhang4431
    @stevenzhang4431 3 роки тому

    When I have a company which needs a vedio like this, please make one with half price discount