DEYE "Time of Use" explained
I noticed that a lot of people struggle with the concept of Time of Use (TOU) settings.
Here I try to explain how to use the time settings by looking at my usage graphs on the Solarman Business web layout.
The TOU should be a kind of "back-stop" to prevent deep discharging, and secure a SOC minimum.
It can also be set to charge via grid of generator (seldom used).
Переглядів: 2 420

Відео

The greatest addition to my geyser: Sonoff TH Elite 20A Wifi Temp. meter
Переглядів 3,3 тис.7 місяців тому
Since I heat my 150l geyser via the Smart Load output of my Deye inverter (excess solar), I needed a beter way to manage the heat. The geyser's own thermostat can be set to max (around 70°C) Excess solar, after the battery is charged, will heat the geyser. When it's cloudy, the grid must heat the geyser. I wanted to take the guess work out. It will only use grid power at certain times of the da...
Solar production: NE vs NW facing panels
Переглядів 220Рік тому
This video gives an indication of the difference between production if North East and North West facing panels. It shows the angles from the sum and real-life production persentages. Tech specs: String 1 (P1) - N/E facing String 2 (P2) - N/W facing Both are 4x 550W = 2200W max ea. Deye 8kVA hybrid inverter Panels installed on 18 Oct. 2023 Slightly dirty (cleaned with water & cloth 2 weeks ago) ...
Installation layout of my Deye 8kVA hybrid inverter
Переглядів 7 тис.Рік тому
Here are more information on the technical layout of my inverter setup. - 8kVA DEYE hybrid inverter - Stage 2 (7.68kWh, 1C) VOLTA battery - 2 Strings of 4x 550W JA solar panels (more panels will be beneficial during winter) 50A breakers to inverter 40A breaker from inverter 40A ELU before Essentials loads 25A ELU (or 2P breaker) to Smart Load Geyser 1 - 150L - 3kW Geyser 2 - 200L - 2kW (replace...
HIKVISION IP VIDEO INTERCOM
Переглядів 362Рік тому
A shortened version op PIPL's introduction to the complex video intercom systems by Hikvision. It is modular with multiple configurations
Deye inverter: Smart Load settings powering 2 geysers
Переглядів 6 тис.Рік тому
A short practical video showing conditions and settings for using your Smart Load output to power geysers.
Hikvision integration: Intercom/CCTV/audio/Face readers/Alarm
Переглядів 208Рік тому
Bioshroom is a new company in the medical mushroom field. Their new cold storage and production factory a has been equiped with IP cameras inside. The Hikvision AX Pro wireless alarm integrates with camera footage sent to App Notifications. An IP video intercom rings on a 7" touch screen monitor anywhere on the network, as well as on Apps with shared access or via free software on a laptop. The...
Smart Load feature on Deye inverter used to max. (first version)
Переглядів 14 тис.Рік тому
A description of how I am using my inverter's Smart Load output. It's parameters are set to power 2 geysers insequence. These settings have meanwhile been improved upon. Update Both the TOU settings are better and a Sonoff TH20 temp. Wifi timer has been added for accurate automation of the grid feed to the geyser. (see my video)
8kVA DEYE inverter UPS
Переглядів 4,3 тис.Рік тому
This video explains the wiring and components of a 8kVA quality inverter installation with two 5.5kWh Hubble AM-2 lithium batteries. It is connected from the garage to the upstairs DB where essentials are separated from the non-essentials. A WiFi Smart timers is added to the geyser, which will later, after the solar installation is done, be powered by the excess solar power via the Smart Load o...
Hikvision AcuSense camera with AI triggers for perimeter protection
Переглядів 2,4 тис.2 роки тому
Preventative measures for perimeter protection using Acusense AI cameras and bi-spectrum 2-in-1 cameras (thermal & colour). Alarm: Line crossing AI (human & vehicle detection) Visual verification: Colour & thermal image Response: Pre-recorded audio message & live 2-way audio with flashing light. The trigger set-up on AI cameras makes the versatility so much better than traditional alarm sensors...
Perimeter Protection: Hikvision bi-spectrum thermal cameras
Переглядів 8822 роки тому
Still the most cost-effective perimeter protection solution currently on the market. The concept is to simulate a guard's three senses through technology: Ears - traditionally alarm sensors - now: AI video detection (colour or thermal) Eyes - still CCTV cameras - thermal cameras assists in dark areas Mouth - traditionally a siren - now a verbal warning (recorded or live) It just makes so much m...
Hikvision iPad control of PTZ - older version
Переглядів 1602 роки тому
The application was for a golf course installation where PTZ and other cameras are controlled in the guard house. The challenge is to provide a simple way for the guard to use two of the most important features: 1. Audio warnings (available via Hik-Connect on iPad) 2. Quick PTZ control on the iPad and via the joystick The downfalls will be: - the guard can by accident change the Presets of the ...
Hikvision DS-2CD2T46G2-ISU/SL Acusense camera with audible warning
Переглядів 3 тис.2 роки тому
For more effective perimeter protection you need the "ears", "eyes" & "mouth" of a guard simulated. AI cameras can now do this very effective with ever increasing accuracy. We just add a horn speaker where distances exceed 10m from the camera.
Thermal triggers on DS-2TD2628-10/QA bi-spectrum camera
Переглядів 7 тис.2 роки тому
Accurate perimeter protection with AI Line crossing & Intrusion detection with the thermal lens. The colour low-light lens provides the hi-res colour or B/W images for identification. The triggers outside the fence will initiate the pre-recorded audio message and flashing white light (or constant on). Off-site monitoring will then address the intruder live. If not detered, armed response will b...
Hikvision DS-K1T501 Demonstration
Переглядів 2902 роки тому
Hikvision DS-K1T501 Demonstration
Hikvision IP video intercom - Afrikaans
Переглядів 732 роки тому
Hikvision IP video intercom - Afrikaans
FLUSS demo - BLE gate opener
Переглядів 2862 роки тому
FLUSS demo - BLE gate opener
Perimeter Protection with Hikvision thermal bi-spectrum cameras
Переглядів 9 тис.3 роки тому
Perimeter Protection with Hikvision thermal bi-spectrum cameras
Hikvision DS-KB6113-WPE1 demo
Переглядів 2763 роки тому
Hikvision DS-KB6113-WPE1 demo
eLearning 3DVista introduction
Переглядів 7743 роки тому
eLearning 3DVista introduction
Stilbaai Virtual Tour Intro Video
Переглядів 3874 роки тому
Stilbaai Virtual Tour Intro Video
Virtual Tour: de Warenmarkt restaurant, Stellenbosch
Переглядів 774 роки тому
Virtual Tour: de Warenmarkt restaurant, Stellenbosch
iPad Hik-connect application
Переглядів 3,8 тис.4 роки тому
iPad Hik-connect application
Anti-vandal covert mounting of a strip beam
Переглядів 624 роки тому
Anti-vandal covert mounting of a strip beam
Hikvision DS-K1T607 face reader set-up intro
Переглядів 2684 роки тому
Hikvision DS-K1T607 face reader set-up intro
Hikvision DS-K1T607 Face recognition reader
Переглядів 4914 роки тому
Hikvision DS-K1T607 Face recognition reader

КОМЕНТАРІ

  • @MohammadArshmaan-u4z
    @MohammadArshmaan-u4z 5 днів тому

    How to install plz shear any vedio

  • @JohnBoy79
    @JohnBoy79 20 днів тому

    have you connected the output cables straight into the heating element or into a separate relayed circuit? is that a 3kw element? any issues with it yet?

    • @juanlourens5753
      @juanlourens5753 20 днів тому

      I can use the 20A onboard relay, but decided to rather drive a seperate 20A relay. No problems yet in many months. Works very well, even with the 3kW element.

  • @Geninfobu
    @Geninfobu 23 дні тому

    Hi, I have 2 geysers, hence wud need to temp wires, would I also need two sonoff screens as well ?

    • @bolandsystems2024
      @bolandsystems2024 22 дні тому

      Yes, one each. They are very cost effective. You can decide if you want to use the relay for On/Off via time & temp.

  • @kovimre2
    @kovimre2 24 дні тому

    What is the firmware version? Where Can I download?

  • @johnrenwick5464
    @johnrenwick5464 Місяць тому

    Thank you for the video. It's sorely needed. I've set my TOU to 40% apart from nightime but I can't understand why my batteries are not charging beyond 40% when it has been sunny all day. I am expecting 90% plus

    • @bolandsystems2024
      @bolandsystems2024 Місяць тому

      It will be a setting issue, most likely. Watch as many video as possible & read the manual.

  • @tshepolr5833
    @tshepolr5833 Місяць тому

    Hi, At 07:50 you mention that it will charge battery first and not supply the load until the battery hits 60%. Is this not due to the "battery first" setting that you ticked on the Working Mode slide 1?

  • @tshepolr5833
    @tshepolr5833 Місяць тому

    Finally I find someone who has done what I thought should be an optimised setup. How has the Andowl ATS performed? I have always wondered how well built it is as opposed to their version sold by ACDC.

    • @bolandsystems2024
      @bolandsystems2024 Місяць тому

      Hi. I dont know the Andowl ATS, but I did combine the Smart Load with a Sonoff Temp control via eWeLink on the grid supply to the geyser's auto change over switch. That's to optomize grid useage when it rains. I have a video on that as well. It works like a charm.

  • @Bripromo
    @Bripromo 2 місяці тому

    Hi friend, will the batteries discharge if TOU don't checked/tick✅️ ??

    • @humdrum3899
      @humdrum3899 2 місяці тому

      No, they won't.....I tried this myself

    • @bolandsystems2024
      @bolandsystems2024 Місяць тому

      The tick boxes are ONLY for grid charging if SOC is under the set %. PV will still charge it. PS. I made a mistake by ticking battery 1st. (by accident) I have change it to Load 1st.

  • @humdrum3899
    @humdrum3899 3 місяці тому

    Thanks for the vid......can you please explain why TOU time slot 1 should be 00:00 and TOU time slot 6 should be 00:00. I understand that it's a 24 hour period and this is logical. I've had friends set this up differently......Time slot 1 17:00 hours and worked through the 24 hour period to end with 17:00 at time slot 6. Is this not recommended? TIA

    • @bolandsystems2024
      @bolandsystems2024 2 місяці тому

      Just a recommendation by so many who have had issues if not set that way

  • @mohdshahrir6426
    @mohdshahrir6426 3 місяці тому

    If i dont have battery, this time of use i need to tick or not?

    • @bolandsystems2024
      @bolandsystems2024 3 місяці тому

      Weird for me to imagine an inverter without a battery, but yes, the TOU setting will then not be needed. It is used for the switch between grid and battery (or generator) I assume you only run on solar & grid. Load 1st would be the setting to tick.

  • @olteandan
    @olteandan 3 місяці тому

    Thanks, i just installed a deye inverter and had trouble making it draw from the battery at night. Deye should've put a simpler setting on the menu, e.g. when there is no sun and no pv input, to simply pass on battery and after it goes to low battery to go on the grid again. Of course Time of Use is useful in different scenarios, but a simpler setting could be also great for most users

    • @bolandsystems2024
      @bolandsystems2024 3 місяці тому

      I find the TOU settings extremely helpful once you understand them. I have change my approach a lot since I started a year ago. To many guys don't really understand how to use the TOU effectively,. That is why try to help with this video.

  • @cosminsabu4488
    @cosminsabu4488 3 місяці тому

    Could you help me with something please

  • @BradleyRautenbach
    @BradleyRautenbach 3 місяці тому

    Are you able to download the history using that arrow in the top right corner of the history? What format does the history download in?

    • @juanlourens5753
      @juanlourens5753 3 місяці тому

      Date, Time, temp., humidity, %RH [I don't measure the last 2] In CSV (Excel file format) Can then share from your phone

  • @ameercader
    @ameercader 3 місяці тому

    How do I get smart load to work please 😊

    • @bolandsystems2024
      @bolandsystems2024 3 місяці тому

      See manual: 1. Wire as an OUTPUT onto GEN input 2. Set SMART LOAD settings in GEN setup 3. Parameters set to switch output ON: a. Solar Watts must be reached b. Battery SOC% must be reached BOTH MUST BE REACHED TO SWITCH ON. To be done by an electrician!!!

    • @appalachianmoonshiner7084
      @appalachianmoonshiner7084 3 місяці тому

      @@bolandsystems2024 what about setup when there is no option in menu solar watt. There is only bat On and Off?

  • @attilakollo50
    @attilakollo50 4 місяці тому

    Hi, if im completely off-grid, i want to use geyser connected when there's enough extra energy, but night time and specially in the winter time i would also like to have simultaneously a generator connected, where i would connect the geyser and where the generator? the gen or the grid port? and which settings would help in such a case?

    • @bolandsystems2024
      @bolandsystems2024 3 місяці тому

      1. Insolate your geyser REALLY WELL!!! It's cheap and means you only heat it once during the day when there is enough sun. Heat lasts till the morning. (monitored via Sonoff TH20) 2. Set the thermostat to max. (70 degrees C) for Smart Load max. heating. 3. Add the Sonoff TH20 Elite temperature/timer unit like in my other video. (switches on when below a temp. / off if above) 4. Add a auto change over switch (like in other video) for external power to geyser (Smart Load as default input) Note: I am not familiar with generators, but here is a basic idea: (ATS might be needed) 5. Gen options (depending on size): a. power straight to geyser through auto-change over switch (managed via Sonoff temp. timer) OR b. to Grid input of inverter (check: Hz range of gen. & size [only run at 50% capacity continuously] [Gen input will be used as Smart Load output - thus unavailable for generator] You only need a trigger to start up the generator when the temperature is below a certain value (40 degrees) and off above say 46 degrees. That must trigger the generator to send power via the auto-change over to the geyser. This is the most effective way to minimize alternative power to the geyser. (managed according to temp.) You can optionally add an external trigger as well to start the generator if the batteries runs low. (if connected to the grid input)

    • @bolandsystems2024
      @bolandsystems2024 Місяць тому

      I prefer to use the Gen input for the Smart Load output because of the excellent parameters to heat geysers. You can then put the generator on the Grid input. There are videos on that (same as Sunsynk) Re Geyser use: heat once to max. heat (70°C) with free heat (SL), isolate VERY well, then keep off. It stays hot enough till the morning. Add a Sonoff TH20 temp meter to view & control temp. (see my other video)

  • @muhammedbux8302
    @muhammedbux8302 5 місяців тому

    What size and number of panels do you have to produce 4.2kw

    • @bolandsystems2024
      @bolandsystems2024 5 місяців тому

      8x550W JA Solar

    • @muhammedbux8302
      @muhammedbux8302 5 місяців тому

      Thanks for the reply. I have the same size and number of panels but at peak am producing 1,200w at peak. Am also in a country with climate as SA. How can i diagnose the problem? I have a 12.5kva deye inverter

    • @bolandsystems2024
      @bolandsystems2024 3 місяці тому

      @@muhammedbux8302 you should be getting 4.kW..... touch on solar icon and see Volts and Amps of strings. Should be around 160V - 180V for a 4 panel string and Amps will fluctuate according to sun. Watts on each string should approach 2.2kW on very sunny day. Otherwise you have: shading issues or a bad installation

  • @forextrading2615
    @forextrading2615 5 місяців тому

    Hi can you please help me the smart load never switches when the solar is zero.It stays on. What do you think is wrong. Battery settings is ON at 100 and off at 90

    • @bolandsystems2024
      @bolandsystems2024 3 місяці тому

      Set Smart Load on at 85% or 90% (when reaching 100% battery will drop to say 98% and not go up to 100% again - not triggering SL setting) Plus, you need some battery charging left to keep the load above your SL setting (say 2000W) The only time SL tends to stay on, is when it is on and grid fails. (does not switch off - so I added a timer to cut at 3pm)

  • @tiamiyuoladele1902
    @tiamiyuoladele1902 5 місяців тому

    Hi please I need a guide to connect sunark lithium battery connection chatting from Nigeria :

  • @ameercader
    @ameercader 5 місяців тому

    Thank you so much ! My inverter is not showing any battery information. The yellow lan cable is connected to CAM don't know what is going on please help

  • @fotiskarelas3321
    @fotiskarelas3321 5 місяців тому

    Hi, have you tried to send the temperature to the Sonoff NSpanel Pro?

  • @stanslaszulu
    @stanslaszulu 5 місяців тому

    Sorry for my possibly damn question. I have 2 5kw Deye inverters that I want to use at home. Can I possibly have the normal load put on the load side and then the rest (geyser, oven/stove and aircons) on the smart load. What happens if, at any time, the total load (smart plus normal) exceeds the inverter capacity which in this case will be 10kw? Are you also able to share a wiring diagram for the smart load side of the connection?

    • @bolandsystems2024
      @bolandsystems2024 5 місяців тому

      @@stanslaszulu the Smart Load is only useable for "excess solar" It only switches on when your battery is almost full an PV is high (according to your settings) You should put everything on Load, eccept things like stoves (geyser) which can still be power by solar & battery, but not during a power failure. (CT must be placed correctly) Watch my other videos on Smart load and auto change over switch useage.

    • @stanslaszulu
      @stanslaszulu 5 місяців тому

      @@bolandsystems2024 thanks for the response and I will watch more of your vids on smart load. I am in a smaller house and my normal/consistent load is about 500watts which is 2 fridges, TVs, lights, internet routers, a laptop or 2 plus some speakers. I am using one 5kw inverter. The most load it has handled is 4kw when I had a heading element and microwave on but this was for a short time. I am moving to a bigger house where the consistent load will increase to maybe 1200 when I add more lighting plus cameras, gats motor and water pump. I will install two 5kw inverters in the bigger place. Plus I have panels with max wattage of 11kw plus total storage of 20kwh. I know I will have a lot of excess power so I am trying to figure out how I can optimise the use of the excess capacity to power the rest of the heavy appliances like geysers, aircons and possibly stove/oven using the smart load.

    • @bolandsystems2024
      @bolandsystems2024 5 місяців тому

      ​@stanslaszulu with that setup, I would: Put everything on Load, except the older type of stove (can still be driven by solar & batteries if set to: Zero export to CT.) Then follow my setup for your geyser to be powered by - Smart Load [when ever there is excess PV & batteries almost full] - Grid [when it's cloudy] - a heat pump is expensive but works lovely on an inverter We use an airfrier (oven type), induction stove & microwave and have no more need for a stove Make sure your aircon are the inverter type. They are great with power usage and soft start. In winter you might struggle to get 20kWh batteries loaded to full with 11kW panels. Rainy days your PV can drop to 10% production or even less. Adding panels will not be a sound investment though (pay 100% for 10% - 50% production for a few cloudy days only)

  • @NikitaGarets
    @NikitaGarets 5 місяців тому

    Sorry for stupid question, is it possible to use Load and Gen outputs simultaneously? (Can not understand English fully)

    • @bolandsystems2024
      @bolandsystems2024 5 місяців тому

      @@NikitaGarets yes, it is 2 different outputs. You can not use Smart Load output and Generator input together. It is the same connection

    • @bolandsystems2024
      @bolandsystems2024 5 місяців тому

      @@NikitaGarets yes, the Smart Load output is just a Load output with parameter settings (%PV & Battery SOC)

  • @ahmedomar7743
    @ahmedomar7743 6 місяців тому

    Great video, can this work for a solar geyser?

    • @bolandsystems2024
      @bolandsystems2024 6 місяців тому

      1. If the temp probe can be alstuck on where the heat of the water can be measured. 2. It then provides a relay for any power to be switched on/off via a combo of time & temp.

    • @ahmedomar7743
      @ahmedomar7743 6 місяців тому

      Thanks sir what putty glue was used?

    • @bolandsystems2024
      @bolandsystems2024 6 місяців тому

      ​@@ahmedomar7743Den Braven Glue Screws

    • @bolandsystems2024
      @bolandsystems2024 5 місяців тому

      Sorry for the late reply. I don't think so. You would need to access a spot on the geyser that is hot to stick the probe onto

  • @GGLMalan
    @GGLMalan 6 місяців тому

    Boer maak 'n plan! Clever my friend. Congratulations. We need innovators like you!

  • @KamenKr
    @KamenKr 9 місяців тому

    What does this Smart text mean?

  • @nielkotze
    @nielkotze 9 місяців тому

    Hi. Regarding your setup that allows a 2nd geyser to be heated if the 1st one is already hot: What is the name of the "relay" that you refer to in your video? ua-cam.com/video/fIXeK_-b12c/v-deo.html I am currently running my geyser on SmartLoad. No issues there. On a sunny day, my batteries are fully charged and my geyser is hot before midday. The rest of the day, my panel power is mostly wasted. I was considering powering an additional geyser using your "relay" setup. Perhaps you have more information on how it works or could supply the part name or a link that explains how to set it up. Thank you in advance.

    • @bolandsystems2024
      @bolandsystems2024 9 місяців тому

      Hi Niel. The relay is a common DIN rail 20A relay powered by 220Vac. Most electrical suppliers should have one. (CHNT model NCH8-20/11) My Smart load goes to both, but the 2nd geyser's power 1st goes through the relay's N/C. That means, when the Smart Load power switches the 1st geyser on, it also powers the relay to open the N/C contact to the 2nd geyser. When the 1st geyser's thermostat switches off, the power to the element is cut. The relay is therfor wired onto the element of the 1st geyser. I also added DIN rail LEDs to indicate which one is on. 1 - connected to feed from element to relay 2 - connected to feed to 2nd geyser's tripswitch (better to connect to it's element input) You should strongly consider a 200l geyser & 2kW element (with screw connectors on element) as your spare geyser BEFORE your main geyser's input. Water flows through 2nd geyser to 1st (main) geyser The main geyser's temp is regulated (50°C) and the spare geyser is dependant on excess solar, set to 70°C (fluctuating) So add a wifi timer to your main geyser, preferably via an auto change-over (SL or timer input to power geyser 1) If it rains, the timer will switch on & heat the main geyser. 90% of the time your SL will heat both. Let me know if you need a sketch.

    • @nielkotze
      @nielkotze 9 місяців тому

      @@bolandsystems2024 Hi. Please send me a sketch if you can 🙂

  • @fikridusakabinoglu2744
    @fikridusakabinoglu2744 10 місяців тому

    Very late notification thank you for sharing video

  • @haniefbhat6695
    @haniefbhat6695 10 місяців тому

    Whats the setting all my noti8fcation are on even the calling notification but my phone isnt ringing

    • @hssnbt6557
      @hssnbt6557 9 місяців тому

      That’s Same problem coming to mee

    • @weforfix
      @weforfix 7 місяців тому

      Same

    • @aamirbutt6272
      @aamirbutt6272 Місяць тому

      Here same once or twice its ringing now hundred time i call but not ringing on mobile

  • @vusimuzivilakazi4563
    @vusimuzivilakazi4563 10 місяців тому

    Good day, can I get your contact number I want to connect a system that can run a geyser and I need some advice.

  • @SafeAndSecureAlarmsTV
    @SafeAndSecureAlarmsTV 11 місяців тому

    Hi love these videos. What is your experience with the thermals vca detection in moderately dense folioage - pine trees and large bushes. Does it still detect human intrusion? Thanks

    • @bolandsystems2024
      @bolandsystems2024 11 місяців тому

      Hi. No, it detects heat, therefor it needs a clear line of sight. A cleared strip of about 2m is usually requested outside the fence. Max. & min. sizes must also be tested near & far

  • @marcoferreira3350
    @marcoferreira3350 11 місяців тому

    How to program the micro sd card to work? and take the prints

    • @bolandsystems2024
      @bolandsystems2024 11 місяців тому

      The SD card is in the monitor. In the programming on the monitor, you can format and set it up. You have to tick the box in programming to do recordings

    • @marcoferreira3350
      @marcoferreira3350 11 місяців тому

      Is there a video demonstrating this process ?@@bolandsystems2024

  • @ChidoriTensen
    @ChidoriTensen Рік тому

    Does it work vertically?

  • @mohamadrashid5854
    @mohamadrashid5854 Рік тому

    Hello i have a question I also use smart load on my deye 6kw inverter I put my conditions for 50% 55% for the battery and the 1000w for PV For the on condition it is doing alright (when pv is higher than 1000w and lithium battery it kicks on) but for the off condition it only kicks on when the battery is below 50% and ignores the PV condition Can you explain that to me please

    • @bolandsystems2024
      @bolandsystems2024 5 місяців тому

      It swithes On when both parameters are met. It switches off when 1 parameter is not met >1min. It swithes back on after the battery has charged & both are met again. Your geyser's kW should preferably be lower than the PV setting, or you will cycle your battery a lot!

  • @sakkieplakkie204
    @sakkieplakkie204 Рік тому

    Good day Nice Installation. Do you mind sharing your drawings please. Regards

  • @JAMESJAMES26000
    @JAMESJAMES26000 Рік тому

    Does it have motion detection?

    • @bolandsystems2024
      @bolandsystems2024 Рік тому

      No, it will drive you crazy. You can add the image to your NVR with very basic motion detection recording, but is seldom needed. With an SD card in the monitor it records: 1. A picture snapshot of the one ringing 2. A voice message can be left if no-one is home.

    • @marcoferreira3350
      @marcoferreira3350 11 місяців тому

      @@bolandsystems2024 This configuration is already the factory default. Or do we have to configure some setting for this?

    • @bolandsystems2024
      @bolandsystems2024 11 місяців тому

      No. Only recording a snapshot on ringing. You can pull in the gate station's camera on a NVR, with motion detection, but currently it is only very basic motion detection (not AI)

  • @ThePonderi
    @ThePonderi Рік тому

    You should consider more panels they are getting cheaper.. especially that you have 2 geysers. Solarways warehouse have better prices for the panels.

  • @ThePonderi
    @ThePonderi Рік тому

    Very inteeresting. How lon do you heat up a single geyser? I understand they are 2kw ?

    • @bolandsystems2024
      @bolandsystems2024 Рік тому

      It depends on how empty (cold) it was. If almost fully empty (cold) a 150l will take 1h30min on 3kW. If heated with solar power, I turn it up to 60°C to last till the morning. I have a 200l with 3kW element in, but use little water to pre-feed a regulated temp geyser (Harver 30l induction) If fully empty, I guess a 200l, 2kW will take around 3h. With enough sun, it's ideal. Smart Load starts around 10:30am (summer) You then have until 4pm to heat the geyser (4.4kW panels as minimum)

  • @ThePonderi
    @ThePonderi Рік тому

    Excellent setup on your geysers...

  • @schunkelndedschunke6914
    @schunkelndedschunke6914 Рік тому

    Well done. Greetings from Austria.

  • @ulasvergili3160
    @ulasvergili3160 Рік тому

    Bok😂

  • @dieselodesa
    @dieselodesa Рік тому

    My Deye invertor, Smart Load "on" only 100% battery. :(

    • @bolandsystems2024
      @bolandsystems2024 Рік тому

      You can set the SOC% for ON & OFF at any %. I choose 90% On, because I want some reserve charging left over for the battery. Once my Volta reaches 100%, any load > PV will let the SOC drop with only a trickle charge feeding it (will not charge to 100% again before it drops below 90%)

    • @dieselodesa
      @dieselodesa Рік тому

      @@bolandsystems2024 you can't do less than 100% on my deye. The inverter does not allow you to change this setting. That's why SMART doesn't start for me. And in general, everyone praises Deye, but I don't like it, there is a lot in it, but it doesn't work, or it doesn't work normally.

    • @nielkotze
      @nielkotze 9 місяців тому

      ​@@dieselodesaMy Deye 5KW inverter is the same. The ON battery SOC % cannot be changed. I ran into the following issue (but there is a workaround): My standard backup load is around 500W and my geyser is 2000W. I figured the logical "Power" setting under SmartLoad should be 2500W, which can run backup load and smartload without needing the battery to help. On heavy cloudy days, I only reached 2500W solar out much later in the day. By then, the battery managed to recharge back to 100% with less than 2500W available solar power. The BMS on my Volta Stage 1 batteries ( 2 of them in parallel) does not keep the battery at 100% SOC. Not long after reaching 100% SOC, they will drop down to 99.9% SOC. And now for the issue: When solar output did reach 2500W, my batteries were 99.9% SOC and SmartLoad would not turn on as the batteries are not 100% SOC. The workaround was to change the "Power" value to a lower value (1500W). Now, when the batteries do reach 100% SOC, SmartLoad turns on because the "Power" value is met. The drawback is that the battery will need to supplement power if there is less than 2500W. If there is for example 2000W solar power available, the inverter draws 2000W from the panels and 500W from the battery. This is not a problem in general as the battery will only drop to the OFF SOC % setting in a worst case scenario. In most cases, I do draw a bit of battery power until solar output reaches 2500W. I hope this helps.

    • @bolandsystems2024
      @bolandsystems2024 9 місяців тому

      Depending on your firmware, when you choose Smart Load, the the % appears under Micro Inverter. Change the % settings there. (When you tick Micro inverter, you will see the % changes, thus those blocks are used for both SL & MI... confusing, I know)

  • @bolandsystems2024
    @bolandsystems2024 Рік тому

    Look for the full video from PIPL

  • @jaxlanraxran-sf5fn
    @jaxlanraxran-sf5fn Рік тому

    Please tell me the configuration

  • @mrmacknackers
    @mrmacknackers Рік тому

    Can i call you ? Setting this up

  • @husainalli
    @husainalli Рік тому

    What will a geyser control box setup like this cost?

    • @bolandsystems2024
      @bolandsystems2024 Рік тому

      Hard to say. I do not know your setup. Ideally: a 2nd 200l geyser connected to the Smart Load output (electrician) replacing the 4kW element with a 2kW (plumber). Add an auto change-over switch & smart wifi timer. Optional: add relay powered by main geyser's element to switch between 2 geysers. Electricals +-$300 (R6000) 2nd geyser +-$600 (R12000) You should not need to use grid power ever again, other than cloudy rainy days. Temp is much more controlable than solar geysers which tend to overheat

    • @husainalli
      @husainalli Рік тому

      @bolandsystems9707 thanks. How can I get hold of you?

    • @Vkara01
      @Vkara01 11 місяців тому

      Where did you get the Changeover switch that has the WiFi capability?

    • @bolandsystems2024
      @bolandsystems2024 11 місяців тому

      @@Vkara01 no, the WiFi switch is left of the auto-change over. It provides grid power to the change over if SL was not enough

  • @dannyvermeulen8570
    @dannyvermeulen8570 Рік тому

    Can you please upload some videos on the variety of HIKVision Ax Pro products? I am not finding many videos online. Ive just started to install some of these products and will currently run two systems side by side until i have enough products of the HIKVision Ax Pro.

    • @bolandsystems2024
      @bolandsystems2024 Рік тому

      Hi Danny. You 1st have to see which products are available locally. The outdoor & indoor PIRs, siren(ind/outd), remotes, panic buttons, magnets, relays, transmitters for 3rd party sensors should be available. You can then use their TX in any other wireless sensor like Optex/Takex if Hik does not have a simular product. You loose a few nice features (walk test), but nothing serious. As installers we work with the Hik-PartnerPro App for setup & management, but you should be able to do it all on Hik-Connect as well (or download HPP) It is pretty intuative.

  • @fernandobainotti1084
    @fernandobainotti1084 Рік тому

    Good Job! 👏

  • @malikmansoor4960
    @malikmansoor4960 Рік тому

    Could you please share alarms

  • @malikmansoor4960
    @malikmansoor4960 Рік тому

    Please share all alarms how do they sound

  • @Maxol744
    @Maxol744 Рік тому

    What camera model is this?

    • @bolandsystems2024
      @bolandsystems2024 Рік тому

      Sorry for the late response... It is the DS-2TD2628-10/QA