- 26
- 111 244
Pylontech Solar Panel Battery Storage Installation
Приєднався 2 кві 2022
Pylontech Solar Panel & battery storage installation offers FREE basic advice and basic support services. We also offer sales of all Pylontech Batteries , on and off grid solutions, inverters and cables. Please get in touch or email us at premiercomputers666@gmail.com for all sales enquiries. Please note technical support is charged at £15 per question payable by PayPal whether or not a solution provided works. If you buy from us then technical support is free for Pylontech batteries, inverters etc.
We have over 100 subscibers, so keep it going. I will make more videos but need subscribes to this channel.
Goto www.premiercomputersolutions.co.uk to buy your new Pylontech solar storage battery, FREE LIFETIME technical support with every purchase on our website. Premier Computer Solutions is based on the UK.
We have over 100 subscibers, so keep it going. I will make more videos but need subscribes to this channel.
Goto www.premiercomputersolutions.co.uk to buy your new Pylontech solar storage battery, FREE LIFETIME technical support with every purchase on our website. Premier Computer Solutions is based on the UK.
Setting and installation of CT Solar clamps when adding extra Solar panels, the correct way
Setting and installation of CT Solar clamps when adding extra Solar panels, the correct way
Переглядів: 289
Відео
Adding extra solar panels to a existing installation Grid tied with battery storage
Переглядів 250Рік тому
In this video I show you how to connect extra solar panels to a existing grid tied system with battery storage
Connecting cables new pylontech us5000 battery installation BMS setup power cables connection
Переглядів 12 тис.2 роки тому
Buy your new Pylontech battery from www.premiercomputersolutions.co.uk and start saving on your electric bill with FREE electric.
Configuring new Pylontech us5000 battery, setting up and installing
Переглядів 2,6 тис.2 роки тому
Buy your new Pylontech battery from www.premiercomputersolutions.co.uk and start saving on your electric bill with FREE electric.
Installing new pylontech us5000 4.8Kw battery. Buy from www.premiercomputersolutions.co.uk
Переглядів 7072 роки тому
opening the box of a new pylontech us5000 4.8Kw battery, what's in the box. Battery was bought in September 2022 from www.premiercomputersolutions.co.uk Buy your new Pylontech battery from www.premiercomputersolutions.co.uk and start saving on your electric bill with FREE electric.
What is the energy price cap meaning , invest in solar pylontech batteries, free electric UK
Переглядів 4582 роки тому
In this video I explain what the UK energy price cap is and why investing in solar battery storage using pylontech batteries available at www.premiercomputersolutions.co.uk , a UK solar battery storage company that ships pylontech batteries to the UK and worldwide could save you many thousands a year on your electric bill. If you can charge your pylontech batteries in the daytime free from the ...
Where to buy Pylontech Batteries in the UK for delivery NOW! www.premiercomputersolutions.co.uk
Переглядів 1,5 тис.2 роки тому
Buy your Pylontech batteries from www.premiercomputersolutions.co.uk . Next day UK delivery, stock available NOW! Save thousands a year on your electric bills in the UK. Buy now!
True Energy Efficiency saving of having polytech battery storage. Save £1500 a year, electric bills
Переглядів 5402 роки тому
In this video I explain how you can save thousands on your electric bill per year of you have pylontech battery storage. To save the unused energy from the sun into your batteries. With solar panels alone you have to use the energy there and then . With solar storage batteries from pylontech acailae from www.premiercomputersolutions.co.uk you can save thousands a year off your electric bill. As...
Www.premiercomputersolutions.co.uk, Balancing pylontech batteries, fault finding, fixing overload
Переглядів 3,3 тис.2 роки тому
in this video I inform you how to correctly balance a pylontech battery setup the correct way. please subscribe ..... also visit www.premiercomputersolutions.co.uk to buy your pylontech batteries with free lifetime technical support and after sales advice
Www.premiercomputersolutions.co.uk .Buy pylontech batteries in the UK , full technical support
Переглядів 2082 роки тому
Buy your pylontech us2000c, us3000, us3000c , us5000, etc from a UK based company, www.premiercomputersolutions.co.uk , who unlike other companies offer FREE after sales lifetime technical advice, installation help, help in setting up your new pylontech battery purchased from www.premiercomputersolutions.co.uk . International buyers can also purchase , please contact the company direct. Recomme...
Pylontech DOD , depth of discharge, setting up in inverter , inverter display information
Переглядів 3,2 тис.2 роки тому
www.premiercomputersolutions.co.uk to buy your pylontech batteries with free lifetime technical support and after sales advice Buy your new Pylontech battery from www.premiercomputersolutions.co.uk and start saving on your electric bill with FREE electric.
Adding a new pylontech battery to your existing setup, connecting, fault finding. Turning battery on
Переглядів 1,6 тис.2 роки тому
www.premiercomputersolutions.co.uk to buy your pylontech batteries with free lifetime technical support and after sales advice
Setting up and installing pylontech us2000c battery , connections and interface ports
Переглядів 4,2 тис.2 роки тому
www.premiercomputersolutions.co.uk to buy your pylontech batteries with free lifetime technical support and after sales advice
Unpacking pylontech 2000C battery, adding it to a existing setup, installing and connecting leads
Переглядів 2202 роки тому
www.premiercomputersolutions.co.uk to buy your pylontech batteries with free lifetime technical support and after sales advice
Kate Bush running up that hill playing on YouTube in pub shed
Переглядів 892 роки тому
Kate Bush running up that hill playing on UA-cam in pub shed
Part 3: solar battery storage, is it environmentally friendly? save money on your electric bills
Переглядів 2012 роки тому
Part 3: solar battery storage, is it environmentally friendly? save money on your electric bills
Part 2, saving on your electric bills using solar battery storage, is it worth it? pylontech battery
Переглядів 1,5 тис.2 роки тому
Part 2, saving on your electric bills using solar battery storage, is it worth it? pylontech battery
Part 1, saving on your electricity bills having a solar battery storage system , is it worth it?
Переглядів 1832 роки тому
Part 1, saving on your electricity bills having a solar battery storage system , is it worth it?
Pylontech Battery fault diagnosis tracing faults fixing repairing faults setup battery correctly
Переглядів 7 тис.2 роки тому
Pylontech Battery fault diagnosis tracing faults fixing repairing faults setup battery correctly
Setting up CT clamps for grid load and solar Pv output pylontech batteries
Переглядів 8 тис.2 роки тому
Setting up CT clamps for grid load and solar Pv output pylontech batteries
Adding / Installing a new Pylontech us3000c us5000 us2000c battery to a existing setup/stack
Переглядів 35 тис.2 роки тому
Adding / Installing a new Pylontech us3000c us5000 us2000c battery to a existing setup/stack
Earthing Pylontech batteries successfully the right way
Переглядів 1,9 тис.2 роки тому
Earthing Pylontech batteries successfully the right way
Pylontech battery system connecting to house fusebox Grid AC mains inverter
Переглядів 3,6 тис.2 роки тому
Pylontech battery system connecting to house fusebox Grid AC mains inverter
Pylontech batteries. How to connect power cables together and set them up. Parallel power connection
Переглядів 4,8 тис.2 роки тому
Pylontech batteries. How to connect power cables together and set them up. Parallel power connection
Pylontech batteries, how to network them up , connecting BMS system using CAN. Please subscribe
Переглядів 14 тис.2 роки тому
Pylontech batteries, how to network them up , connecting BMS system using CAN. Please subscribe
www.premiercomputersolutions.co.uk,, pylontech batteries connec, installing linking batteries
Переглядів 3,5 тис.2 роки тому
www.premiercomputersolutions.co.uk,, pylontech batteries connec, installing linking batteries
Buonasera ho acceso il mio impianto e le batterie rimangono in stand by. Pulsa solo il led Run su entrambe le batterie. Dall'app StorageMate si legge un errore di comunicazione con le batterie. Mi potete aiutare?
Yo pondría 2 cables positivo y 2 negativos...así se te calentarán menos...
Hello🥲 i have a problem with the same kind of batteries, i do as the guide says and after i turn the bateries on, the master battery turns on the red led of "ALM" and it doesn't get solves... Any idea of how to fix? Im new around, thanks in advance
How do i restart the batery when it has rundown compleatly
Thanks for sharing 🙏
Hi one of my battery is Indicating a red light on ALM. How can I resolve it
Good afternoon, l have two pylontech us3000 and 5000. The investor is saying PB on screen but they are not charging. What could be the problem please as the electrician seems to suggest that they might have been drained so we need to press the restart button of which we can not find one other than the power. If this advice is ok, do we turn them off with the investor on or switched off please. It is an off grid system. Thank you very much for your assistance
I am looking for the parallel connectors online for my batteries. What are they called? Can you let me know where to find them?
I think you mean the cables. Cables should be available from most solar / PV stores. You’ll need + and - leads . Most battery leads are generic so the end should fit your batteries with the otter side connected to your inverter
Please subscribe to this channel
Ive just added a us5000 to my system, 3 x us2000 1 x us3000c, i have a lux hybrid inverter which needed a modified can connector when I installed the us3000c as the master, but now im having the us5000 as the master, ive had to make another different one, is this common among different brand inverters?
Yes different brand inverters adopt different CAN standards . As you have modified can cable then it will work
Just thought it was odd, I had to modify the cable for the different model batteries from the same manufacturer, yet there is very little if any info on this, very strange
Very little info and not all manufacturers share a set standard. Its a shame really but its the way things are. Please subscibe to this channel. @@WalkabletunaVEVO
Already subscribed 👍
Unfortunately having an issue with my lux inverter, the DC side seems to have gone kaput, batteries aren't charging/discharging and no solar production is happening, my installer is looking into it but just keep going round in circles 😢
Help I have acquired 3 Sonnen brand batteries that are Pylontech batteries. They come on for 10 minutes then shut off. I have hooked to them using RS232, I type “help” to get all the commands for getting info and a little control of the battery. What command I need is how to turn the batteries on permanently. Can you help?
Sorry we only connect using CAN bus. We do not use RS232 , so really cannot tell you how to achieve the batteries permanent ON status but I am sure you have misconnected the batteries somewhere. Best to contact your inverter supplier or where you got the batteries from!
@@pylontechsolarbatterystora3979 I am studying CAN bus right now. I know every communication protocol except that one. Seems like I will need a piece of hardware for my computer or Raspberry Pi, whichever I decide to communicate with the batteries. At least I now know to stop looking on the RS232 port, it provides useful information but does no control. Thanks for the reply.
When and how do you switch the inverter on and off?
Hi. We have a problem with US 5000 single battery. It is showing 100% SOC and has been like this for 72 hours. It will not discharge and therefore we are using grid power rather than stored power in the evening. We have clear skies and pv working during the day and is exporting rather than charging the battery. What would you suggest?
Try to reset your inverter . It controls the charge/discharge of the battery and tells it to discharge through the batteries bms
The new master battery has been fitted and all wired up but when I turn on the batterys all the LEDs on the new battery stay on have you any idea wy
Maybe the new battery has not been fitted correctly
Are you sure you don’t need to balance the charges before connecting to the inverter?
I just added a 3rd us3000c battery in my stack, all 3 are the same model. However, when balancing them, 2 seem to get balanced and go on standby while the third keeps all lights turned on. No blinking. I waited for approx 3 hours already and it remained like that. Would you know what could be causing it or if can just go ahead and plug everything in to the inverter?
You need to run them with the inverter and discharge them to a 0 state . Then when they recharge they will be balanced
can you add a 3000 to a us2000?
Yes.
Is there any dip switch settings required
Only when you use rs485 protocol, this is when you incrementally set the dip switches for each battery. Please subscribe, thanks.
How long did equalisation take?
He's charging 15€ per question. I wouldn't pay it. He didn't even finish the job. Turning them back on and saying job done isn't accurate
I currently have a single stack of seven 2000's which the installer set up. In studying the PylonTech installation manual, it says not to stack them directly one upon another and even when using their super-expensive brackets, it says a maximum of four! Have you ever heard if or experienced. any problem with stacking?
Stacking upto 4 on top of each other is fine. Even when using brackets the benefits are negligible. In a us2000c manual , it says 4 can be stacked on top of each other. But if you are uncomfortable then you can vertically stack them making sure they are secured at the top and bottom.
Hi and many thanks for the video - I have a stack of seven 2000's to which I need to add a 5000. I understand that the 5000 has to become the new master - the question is, how is the new stack balanced when there is a mixture? I was told that I had to first fully charge my stack of seven 2000's and then separately charge my 5000 before adding the 5000 to the stack. This sounds awfully laborious and long winded so is there a neater, simpler way please?
No all you need to do is connect the us5000 set it as a master. Turn the battery’s on, sync them . Then let them balance naturally. Don’t turn your inverter on at this stage. After a couple of hours the bms in the master battery will store the charge state of the other batteries. At this stage turn on the inverter and use as normally. Eventually when there is no sun or extra charge the batteries will reach there minimum SOC and then they will be balanced . No need to charge them up individually, so backwards!
Can only one of these batteries alone work on a 5kva inventor? If yes, how do you connect it
Do they have to be earthed? I have 2 no. 3000 and they're not earthed and Im having problems ballancing them, thanks in advance.
Yes all batteries have to be earthed
They should go down to an earth rod with 16mm2 cable
Where are you located , I have a problem with a Pylontech US200 PLUS. One shows all leds light wherass the other one there's no lights on any suggestion , they were fitted 2018
Please contact premiercomputers666@gmail.com
Hi. I have micro inverters. so all AC NOT DC. The PV CT clamp should go around the live, 240V, of the panel inverters with the arrow pointing towards the panels? so awa from the Consumer unit? thanks
Yes
Can you show wires and layout for solar ct clamp
CT clamps . One goes on the AC meter side , AC coming in on the Live wire to monitor Load in house , the other CT clamp goes on Live of PV in, so you can monitor the power generated by the solar panels. Ok. Thanks for subscribing.
Correct up towards meter when wiring coming from main supply, point away from meter if being installed on wire between meter and fuse distribution board
Thank you very much for this, super helpful!!!!
Thanks for subscribing
Hello! How to eqalize the pylontech battery?
Your videos are excellent amd really worth watching i am connecting 9 pylontech batteries to 3 8kw inverters which in turn will run a 3phase installation do the batteries have to have there dip switches changed thanks
Thanks for subscribing. Glad the videos are helping people. As to your question , no you only need to set DiP switches if your inverter is connected via RS485 protocol. If it’s not then it will be connected via CAN so no dip switch setting required
Been fitting my new US5000 today and was wondering as the short leads are a bit too short, whether you can go straight across rather than diagonal as you have the 2nd and 3rd orange leads. I assume it makes no difference. When I got it all wired up I had one of the original batteries flashing the red light. So disconnected the new battery and put everything back to original and still not working, said no AC input and I found the plug labeled GRID was not properly screwed into the Control box. The retaining ring has a bayonet fitting and could never have been properly fitted by the installers and lifting a 40kg battery, must have shaken the fitting loose.
Just getting ready to go up in the loft after lifting a US5000 into there and checking that I'm up to speed with the connection. Found your video so reassuring to watch. Will see about posting a video of the lift by two OBE's
Thanks for watching and glad you found the video useful. Please subscribe
Very interesting video, thank you, I would like to ask a question; if the solar panels fail to charge the batteries, could they be charged with a charger connected to a generator set ??and how??
You would still need a charge controller. But in principle yes they can be charged from a generator
Brilliant, thanks for this, most useful and much appreciated. Cheers!
Thanks please subscribe. I’ll make more videos if people need help but please keep subscribing. Glad the videos are useful and help people
I have the UP2500 how to i set up the com ports. I just jave two batteries. Which port do i use. I dont have as many as your ones.
Hi, many thanks for your videos, due to a fault with my Solis inverter my Pylontec US5000 battery has discharged and gone into protection mode with the flashing red light, I have since bought another US500 which is working fine and fixed the inverter as I understand I cannot use the good battery to charge the discharged one as they will not be equal in voltage. Pylontec help centre has suggested I use a battery charger at 53v 2a to bring the discharged battery back up to the voltage of the good battery. As the inverter will only work via the power of the battery and not directly from the grid I am stuck as to what to do. Could you suggest any other way round this as I cannot find advice on this anywhere. Many thanks for your help
If you can’t externally charge the us5000 as pylontech suggest . Then the only option is to get it replaced by pylontech. The battery may be faulty as normally the inverter can’t just cause the red light. Also when you connect us5000 batteries together , the master will attempt to charge the other battery. If the us5000 still won’t come out of red light mode then it could be just a faulty battery .
Hi many thanks for getting back, we went away for a couple of days and the inverter didn’t put charge into the battery on the overnight cheap rate and as the inverter receives power from the battery only, it took the battery below 5% thus going into protection mode. I have today found an adjustable voltage DC charger that can be set at 53.2v 2a so I will give it a try. Once again thank you for your time.
It was pleasure helping you. It’s what this channel is all about. Thanks for subscribing, it’s important people subscribe as then I can help people further.
Thank you for subscribing
How is the MAX Amper from 7 battery? is the same of one battery?
From 7 battery’s at each battery 100 amp , continues amperage is 700 amp DC….if each meets its 90% load capacity . The inverter will throttle thus down to meet its own AC output specification
@@pylontechsolarbatterystora3979how will the same 25 sqmm cable handle the increased current.
Hi I have a ME3000SP. ac inverter with 4 2000c batteries ,I would like to add more but not sure if I can as I thought 9.6 was the max. any advise would be appreciated.
You add upto 16 pylontech C type batteries …. to the me3000sp
@@pylontechsolarbatterystora3979 thanks for your quick reply cheers Baz
Thankyou for this very informative video. I have the same us3000c batteries. Two but bought a third. Connected them up in the same way but left the inverter Power +/- cables and rs485 (for some reason installers used rs485 rather than CAN) disconnected. The two current batteries where at 100%. I then pressed the SW switch on the master in order to balance. Lights all flashed in same way but left over night. In the morning all the LED ights where out except the RUN LED light was flashing alternatiing between each battery. Does this mean the balacing performed correctly? Wan't sure if all the SOC lights should then be all lit the same level. I then turned the batteries off, reconnected the power cables from the inverter + to master, - to Last slave and the rs485. Turned the Isolator switch on but then the inverter asks if I want to add a battery. So is it just a question of re-entering the settings?
Yes. The batteries are in standby and should of balanced correctly. When they discharge the current SOC should be displayed on each battery.
The inverter should pick up the new battery automatically. No need to change settings .
But as your system is RS485 and not CAN you may need to put a new address using the dip switches on the new battery itself. Also make sure each battery has a different address setting on the DIP switches
@@pylontechsolarbatterystora3979 Thankyou, The inverter socket does have rs485/CAN so would moving it to the CAN port on the Master battery help?
I bought a battery on ebay. Will it still be in warranty (provided it's not been damaged etc)?
No , don’t think so.
Ok i am lost, you said the voltage is coming FROM the meter.. then the sound cut out a bit. So the CT clamp arrow goes with the direction of flow of electricity from the meter.....or against it? ( it is for a zappi) Cheers
It goes against the flow , not following the flow
Awesome vid mate exactly what I need ... Question...I have 3 x 2000 batteries at present and am going to add another 3000 is it neccessary for the 3000 to be the master?.... also my 3 have been stacked ontop of one another at install same question,... is it neccessary for the 3000 to be at the bottom? as it is the heaviest at 32kg?
Put 3000 at the bottom . Also it needs to be set as master. You can have upto 8 batteries stacked on top of each other , pylontech says
@@pylontechsolarbatterystora3979 superb thanks so much..I'll be watching you and following now ...cheers
@@cassandracurse7065 please subscribe to the channel for more new videos coming up
Hi,you can tel me please, when we must change the position of the four ADD Switches,thanks.
Only when using rs485 protocol , the ADD switches are used
when using rs485, ie voltacon inverter, dip switch set on master for 1st array 2nd etc . 1st array 0001, other batteries on array 0000
Hi we have a zappy charger with ct clamp and also solar ct clamp should they both be on the same meter tail coming from the meter tail load side ? Thanks
No the solar ct clamp should be on the solar positive load side
@@pylontechsolarbatterystora3979 thank you for your advice.
After adding 2 new US3000c batteries to me my existing 3, do I need to change any settings on the inverter to ensure I am charging to the max 17.75kw capacity?
Thanks for this. Do you know if you can mix different capacity pylontech batteries? I currently have 2 x USC2000 batteries and want to add an additional 2 x US5000 to the system to triple my storage capacity from my Solar Edge inverter!
Hi yes you can mix them. The BMS of the master battery which you’ll need to set to one of the new us5000 batteries. So the master battery must be a us5000 in this setup.
thanks for the video, i have a question I have 2 us 3000 in parallel linked up to my solar inverter, I am about to add a wind turbine with a separate charge controller to my system but cant figure out how to connect both the solar and wind cables to the battery as there is only one connector for positive and negative, any suggestions? thanks
in my system I have batteries connected via victron distributor to my inverter. You could connect your wind charge controller there. ie midnite classic, but you need to play around with charge settings so that midnite is always slave to solar.
Can you tell me what is the correct sequence of turning off several batteries?
I am also interested in how to turn on the master and slave dip switches
You only need to set dip switch address if using rs485 communication protocol
Thanks, i have now earthed the batteries. The DoD is set to 80%, can this only be changed by updating the firmware? Mine is version 2.50. Would you be able to do a walkthrough video showing how to upgrade the firmware or is this too risky?
Hi, thankyou for the very informative videos. I had two us3000 batteries and a sofar me3000sp installed a couple of years ago and have just decided to add a us5000 battery which i have just done with the help of your videos. However, I have noticed tgat when it ws installed originally, the istallers have not earthed the batteries. Should i add an earth and is it ok to run an earth from a nearby socket? Many thanks again
If the installers haven’t earthed the batteries then it’s wrong . As to the current load output of the bigger us5000 battery you have, correct earthing should be made direct to the earth bar in your electric cupboard , not just a earth in a socket. If your batteries are not earthed it’s dangerous and your system shouldn’t be used until correct earthing to earth bar is made.