PL162T steam boiler refilling problem - FOR TECHNICIANS ONLY
PL162T steam boiler refilling problem - FOR TECHNICIANS ONLY
Переглядів: 954
Відео
GiuliettaX - ajustar litros filtro de agua
Переглядів 2285 місяців тому
GiuliettaX - ajustar litros filtro de agua
How to replace the main switch support PL62X
Переглядів 2675 місяців тому
How to replace the main switch support PL62X
How to replace the main switch PL62X
Переглядів 2595 місяців тому
How to replace the main switch PL62X
PL2SVX GiuliettaX - Error count 1 or 2
Переглядів 3167 місяців тому
PL2SVX GiuliettaX - Error count 1 or 2
PL62X - How to replace the water charge solenoid valve (9700041)
Переглядів 6328 місяців тому
PL62X - How to replace the water charge solenoid valve (9700041)
PL92T - How to replace fitting MC935F
Переглядів 6398 місяців тому
PL92T - How to replace fitting MC935F
pl162t how to drain the coffee boiler
Переглядів 2,3 тис.9 місяців тому
pl162t how to drain the coffee boiler
How to replace the round main switch 9600052
Переглядів 1 тис.9 місяців тому
How to replace the round main switch 9600052
LELIT VIP line machines: How to replace the pressure gauge (9700031)
Переглядів 9429 місяців тому
LELIT VIP line machines: How to replace the pressure gauge (9700031)
dvg tech up devecchi giuseppe lelit bianca pl162t temperature stability - scace test DUBAI woc
Переглядів 61010 місяців тому
First thing to say is, temperature of the water coming out of the boiler is different from the temperature of the water at which the coffee boiler is kept. E.g. to dispense from the group at 90°C, you have to set the coffee boiler at a higher temperature. This difference (offset) is managed by the LCC within the technical menu at the value EC This value is factory set to 10°C: this means that a...
Come pulire le macine? PL043MMI
Переглядів 1,3 тис.11 місяців тому
- Remove the bean hopper and the two screws below it using a star screwdriver - Unscrew the upper burr - Unscrew the spout with a Torx screwdriver - Using an air pistol, blow on the burr and on the spout - Screw back the upper burr until the upper and the lower burrs move together - Unscrew the burrs ½ turn and screw back the screw - Screw back the spout - Screw back the hopper: 3 (the best gri...
GiuliettaX: How to replace the water charge solenoid valve 9700083
Переглядів 46811 місяців тому
GiuliettaX: How to replace the water charge solenoid valve 9700083
LELIT BIANCA PL162T: connection to the hydraulic circuit
Переглядів 867Рік тому
LELIT BIANCA PL162T: connection to the hydraulic circuit
pl162t flow control oring MC044 OR 2025 Øi6,07 t1,78
Переглядів 808Рік тому
pl162t flow control oring MC044 OR 2025 Øi6,07 t1,78
pl162t how to change the steam boiler safety valve 9700050
Переглядів 2,1 тис.Рік тому
pl162t how to change the steam boiler safety valve 9700050
For me the black part with the spring in it seems to be stuck. I can’t get it out of the machine and it won’t move. Any tips?
Hola, tengo un problema en mi Lelit Marax, al encenderla y apagarla alterna entre las 3 luces intermitentes y luego la luz de encendido intermitente. ua-cam.com/users/shortsQEsNiVEjYDE?si=-8eL8VJMbRkVrOFa
What is the adjustment range on this OPV? My machine in Canada came with a factory setting of 9 bar. Will I be able to adjust it further down to 6.5-7 bar?
I love you guys, I had a loose wire on the PID and I could figure it out with this video. Thanks for this content it is quite useful.
Today I started a descaling procedure and realized no water coming out from the hot water wand. I’ve tried this procedure but still no water coming out. is there anything extra I can do?
Hello, Lelit Insider. Since you have access to the Scace device, what pressure should I adjust in the OPV using the blind basket to result in 9 bar measured in the machine group head during espresso extraction (simulated by adjustable flow on Scace)?
Hi, i have a pl62x and recently there is only steam coming out of the machine, and when i try to fix for the possibility of air in the boiler, there is a very small amount, weak water flow. Any help or clues would be greatly appreciated 🙏
Thanks for the video much appreciated 😊
The tube online says 5mm outer diameter and 3mm inside diameter. When I measure the tube with a caliper, it measures 4.7mm outside and 2.4 mm inside. I ordered 5mm pftte tubing online, but it doesn't not fit. What are the tube dimensions that fit the MC072. Thank you!!!
Never mind. It worked. The cut at the end wasn't super clean and it was catching. I used a razor to cut, and with a little more force, it fit and is not leaking. Thanks for all these videos. They really help a lot.
Hola para Lelit victoria con versión 1.14c que ajustes serían mejor ?
Il mio non si muove. Da stamattina rimane in posizione aperta. E non si lascia girare.
Thank you your video help me figure out how to fix a large scale pump for my job your a life saver
Hello, my Anna has a setting for T1 and T2 and this does not appear in the manual. Has the Anna been updated since you made this video and should I still use the offset of -5° for Anna? Thank you
do you know where can we buy the main switch support ? Mine juste broke today
Buongiorno, a chi devo scrivere per mandare video esplicativo sul problema dell mai macchina Lelit Mara x, fa il caffe ma non salgono i Bar della pompa, quindi non fa crema. Grazie.
Why should I change the EC value and not adjust it in the normal menu with more 4/5 degrees? Is the final result not the same?
Hi.I have one V3 for two years,and today I had a surprise.While in the warming period,the menu device showed crazy numbers.ie 128-127-126-125 descending. I mean Celsius temperature.And again,I have the steam-hot water boiler closed always. I shut off the switch and then on,and the temperature went to 93,which is I have put in the set up. Any suggestions please?
Fantastic video, thank you.
Can the boiler temperature be read on Victoria using 1.14c when TR is switched on? How do you do it? Hold + button on LCC? Thanks for the video
What was the pressure reading on the scace?
Great Video
Hi - thanks for the video! I’ve just bought a MaraX v2. Brewing pressure is fine but the steam pressure doesn’t move at all - like in the last part of your video. Is something broken or kan I do something to fix it myself? Can it be caused by air in the system? Best regards Torben
Ciao Lelit Insider, grazie per i tuoi video: il Paddle è aggiunto after market?
I just bought a second hand Victoria that I suspect hasn't been cleaned for 1 year. I'm watching a lot of your videos now to get this machine back to its prime. So, thanks for your videos!
Guys I have a very curious situation When the paddle is in full left (closed) position there is no flow at all But when it's fully open the flow rate is more than 9 mg/s (>180 milligrams in 20 seconds) How can I fix this?
Awesome channel, many thanks. Great explanations & really good video shots of what you are doing 👍🏻
Hello, My Elizabeth has a leak from the steam boiler sentral fitting. I tried to unscrew the fitting, put a glue and screw back but it didn't fix the issue, looks like it leak not from the thread but from the tube. I think the fitting is broken and needs to be replaced, would you suggest the name of the part to replace. or if I wrong, please suggest how to solve the issue.
ciao! ottima spiegazione, vorrei capire una cosa: come si comporta la macchina se il sensore magnetico raggiunge il livello di low water mentre si sta facendo il caffè? si blocca la macchina oppure c'è ancora a quel punto una quantità di acqua sufficiente per terminare l'estrazione del caffe su due tazzine ad esempio?
ciao ti è mai sucesso che esce acqua dalla caldaia ? perchè è da un paio gg che dopo aver cambiato il caffe fa uno sbuffo dalla caldaia cosa potrebbe essere l oring della caldaia da sostituire ??
Buon giorno ho bisogno di comprare in Amazon o eBay la guarnizione Anita PLO42EM, già ho sbagliato in comprare una ch'è tropo spessa, cerco e cerco ma non mi fido perché cambia troppo il prezzo. Grazie se me possiate aiutate.
Is there a manual explaining all these settings somewhere? The fact that we have paid 1000 euros for a coffee machine and we are trying to learn how to change its PID settings from UA-cam is frankly pathetic. Lelit should respect more its customers...
Hi Lelit Insider, thank you very much for this video. I have a question regarding setting the final pump pressure. Do you have the paddle fully on the left or fully on the right while adjusting the pump pressure at the bypass valve? Thanks
thank you for this video, it helps a lot. Do I have to close the paddle (completely to the left) while adjusting the pump pressure?
come si fa a smontare la parte superiore?
ma come è possibile utilizzare vapore e fare caffè nello stesso momento
ma come è possibile utilizzare vapore e fare caffè nello stesso momento
It's a double boiler
Do you have the part number of the Mara X heating element? Is it the same as the Mara?
Awesome video! This is the part I need to replace as it's leaking on top of the boiler (Lelit Victoria PL91T). Do I just remove old one and screw the new one back in? Do I need to use any kind of teflon tape or other sealend or it just go "naked" thread as is? Thanks a lot!
have you replaced the connection ? did it stop the leak ?
@@sviatoslavzapolskyi7986 Yes, I managed to replace it. I didn't use teflon tape being afraid not to leak teflon tape inside the boiler. So far it works ok, no more leaks!
Thank you for the video! Very useful! I need to replace a leaky L shape quick release as well. I don't need to use any teflon tape or so? Just screw the new part as is and that's it?
But if you remove the micro switch wire and the unit stops beeping does it mean t he micro switch is defective or the reed sensor? Or both?
So, after doing this, you can bring the midle level of e61 back to Bianca, so manual pre-inf as long as you want without flowcontrol
mine just stays with 1.05 for around half an hour and then starts getting hot.
Hi. I have a Bianca,and the L58E group manometer is not working. Is there a spare part of the manometer ONLY,as the slow flow is working very well,and so,I don't need the kit,but the manometer only?
This was a huge help to me thank you!
Very clear explanation, thanks. But why not give it in the user manual?
Salve. Ho un problema di sovrapressione vapore nella caldaia della Mara X PL62X. Ho notato che la led del relè si accende immediatamente quando accendo la macchina e rimane sempre illuminata. Smontato e con il tester ho continuità tra 1 e 2 dunque relè secondo me danneggiato in posizione acceso. Ho cambiato il relè ma anche con il nuovo la led si accende immediatamente e l'SSR non stacca mai mandando la caldaia largamente oltre i 3 bar. A questo punto ho il sospetto che la piastra di potenza Gicar sia danneggiata e non riesce più a pilotare il relè lasciandolo sempre acceso. Ho controllato la sonda temperatura vapore e risulta pulita come nuova, misuro 60k in ambiente esterno e resistenza che va a scendere con una fonte di calore (palmo della mano) dunque direi non in causa.
where can we learn more about the functionality / parameters available in the "technical menu" of the VIP Line machines? On the Lelit web page, Auto Cleaning Cycle is listed under the settings for instance but I have not been able to find that setting. Unfortunately the user manual does not mention any of functionality / parameters available in the "technical menu" either...
I would also like better documentation from Lelit about the parameters and how to access the listed features of this latest firmware
Is there any possibility to buy the magnet alone? Lost mine, don't ask how.
@Lelit Insider: my nearly 3yrs old pl81t The steam lance hardly produces any power at 135 degrees. everything descaled and degreased. What Could be wrong? Everything Else Works Fine
Hi, i have a maraX pl62X. I would like to know if it is useful to put a thermometer to know the brewing temperature and where I can buy it. Thank you