Pinoy Construction
Pinoy Construction
  • 23
  • 623 754

Відео

Ang Basics ng Structural System Part 1 - Code Requirements
Переглядів 87921 день тому
Code requirements prescribed by NSCP 2015 to have an earthquake resistant structural system.
Maling Akala sa Paggamit ng Hook sa Footing Rebars - Part 2 (Full Presentation)
Переглядів 1,8 тис.Місяць тому
Misconceptions in the use of hook or bend on footing rebars.
Maling Akala sa Paggamit ng Hook sa Footing Rebars - Part 1 (Full Presentation)
Переглядів 2,8 тис.Місяць тому
Misconceptions in the use of hook or bend on footing rebars.
Construction Joints Part 1 - Location (Full Presentation)
Переглядів 21 тис.2 місяці тому
General guide regarding the location of construction joints in reinforced concrete buildings.
Slab Structural Standards Part 2 - Rebar Details
Переглядів 2,9 тис.4 місяці тому
Reinforcing bar standards of one and two-way slab.
Ang Structural Standards sa Poste ng Bahay Part 2 of 3 - Reinforcing Bars (Reupload)
Переглядів 3,4 тис.4 місяці тому
The standard and recommended details of reinforcing bars of columns in residential dwellings.
Slab Structural Standards Part 1 - Thickness of Slab
Переглядів 4,2 тис.10 місяців тому
The standard thickness of slab on grade, one-way and two-way suspended slabs.
Ang Structural Standards Sa Biga ng Bahay Part 4 - Main Bar Anchorage
Переглядів 27 тис.Рік тому
Basic knowledge in rebar anchorage (development length)
Column Footing Rebar Details for Single-Storey Residential based from ACI 318M-11 and NSCP 2015
Переглядів 6 тис.Рік тому
Column Footing Rebar Details for Single-Storey Residential based from ACI 318M-11 and NSCP 2015
Ang Structural Standards sa Biga ng Bahay Part 3 - Main Bar Cutoff and Splicing
Переглядів 32 тис.Рік тому
Rules and guidelines in the termination points main bars and splicing in beams.
Ang Structural Standards sa Biga ng Bahay Part 2 - Steel Reinforcement (Main Bars)
Переглядів 43 тис.Рік тому
Beam main bars - recommended size, number, layout, concrete covering and clear spacing
Ang Structural Standards sa Biga ng Bahay Part 1 - Dimension and Sizing
Переглядів 23 тис.Рік тому
The standard and recommended dimensions in the design and construction of beams in residential dwellings.
Pinoy Construction: Maling Akala sa Paggamit ng Anilyo ng Poste (Lateral Tie)
Переглядів 7 тис.Рік тому
Mga ilang maling akala sa paggamit ng anilyo.
Ang Structural Standards sa Poste ng Bahay Part 3 of 3 - Rebar Splicing
Переглядів 31 тис.2 роки тому
Guidelines for column rebar splicing in residential houses.
Ang Structural Standards sa Poste ng Bahay Part 1 of 3 - Dimension and Sizing
Переглядів 67 тис.2 роки тому
Ang Structural Standards sa Poste ng Bahay Part 1 of 3 - Dimension and Sizing
Ang Standard Sizes sa Pundasyon ng Bahay
Переглядів 116 тис.2 роки тому
Ang Standard Sizes sa Pundasyon ng Bahay
Paano Gumawa ng Hollow Block - Ang Tamang Mix Proportion
Переглядів 20 тис.2 роки тому
Paano Gumawa ng Hollow Block - Ang Tamang Mix Proportion
The Basic Concept of Materials Engineering
Переглядів 1,6 тис.2 роки тому
The Basic Concept of Materials Engineering
Magkano ang Magpagawa ng Bahay - Estimated Cost at Budget ng isang Housing Project
Переглядів 2,8 тис.2 роки тому
Magkano ang Magpagawa ng Bahay - Estimated Cost at Budget ng isang Housing Project
Paano magESTIMATE ng Panambak sa construction ng isang bahay?
Переглядів 7 тис.3 роки тому
Paano magESTIMATE ng Panambak sa construction ng isang bahay?
Paano magCOMPUTE ng Cement Sand Gravel (Concrete Estimate) - Detailed Method
Переглядів 10 тис.3 роки тому
Paano magCOMPUTE ng Cement Sand Gravel (Concrete Estimate) - Detailed Method
Paano magLAYOUT ng mga sukat sa construction ng isang bahay?
Переглядів 193 тис.3 роки тому
Paano magLAYOUT ng mga sukat sa construction ng isang bahay?

КОМЕНТАРІ

  • @SamuRai1984
    @SamuRai1984 День тому

    pano po kung sagaran ang lupa, at ecintric type

  • @siresy2463
    @siresy2463 2 дні тому

    Good day sir. Ask ko lang po if 16 mm ang ginamit for 3m beam span, ok lang po ba na isa lang ang cut bar for support and midspan?

    • @PinoyConstruction1
      @PinoyConstruction1 2 дні тому

      Hello po sa inyo? Bago ko po sagutin ang tanong, ano po ba ang width ng beam?

    • @siresy2463
      @siresy2463 День тому

      200 x 400 mm po. Grade 33 lang po na bakal meron sa hardware

    • @PinoyConstruction1
      @PinoyConstruction1 День тому

      @@siresy2463 , yung 1-16mm cut bar ba ay ilalagay sa pagitan ng 2 continuous corner bars?

    • @PinoyConstruction1
      @PinoyConstruction1 День тому

      Kaya po ako nagtatanong ko ang ganito ay upang i-check natin ang clear spacing ng rebars. According to structural code requirements, clear spacing or bars placed in a horinzontal layer (beam rebars) shall be at least the greatest of 50mm, diameter of the rebar, and 4/3 the maximum size of aggregate (gravel). Ang maximum size of gravel for structural concrete ay 19mm. Ang greatest sa 3 ito ay 50mm. I-check mo if ang clear spacing ng 3 bars (2 continuous corner bars at 1 cut na parehong 16mm diameter) ay 50mm or more. If so, ok po yun. If not, change the design sizes.

  • @TheCanopyAirResidencesMakati

    Salamat Engr. New Subscriber here. Ask ko lang po. Nagpapagawa ako ng concrete Fence ngayun. Naka design sya as abang para sa poste ng bahay na itatayo in the future. Dinesign naman sya ng Engr. Ang tanung ko lang po is about sa Splicing. tapos na kasi yung isang mukha ng fence .kakapanood ng video nyo na realize ko yung splicing zone na dapat. Kasi yung putol na ginawa ni Foreman ay pantay pantay na doon sa Vertical bar ng poste. Hindi na masusunod yung sinasabing 50% splice lang dapat. Bale magiging 100% kapag gumawa na ng panibagong poste para sa unang slab. Paano po ba ang aprroach sa ganito? Mukhang heto yung maling nakasanayan na ng mga foreman. Ang sabi sa akin ng Foreman, sa dami na ng ginawa nyang bahay ay puro ganyan ang yari, at wala namang problema. Ang sa akin lang naman ay masunod kung ano ang nasa code. Sana po ay magabayan nyo ako kung ano ang dapat kong gawin. Maraming salamat pong Muli at more power sa inyo.

    • @TheCanopyAirResidencesMakati
      @TheCanopyAirResidencesMakati 3 дні тому

      Idagdag ko lang po Engr., Bale ang dami ng vertical bar ng bawat poste(total 12 columns) ay walo, na may sukat na 4pcs. 12mm at 4pcs. na 16mm.

    • @PinoyConstruction1
      @PinoyConstruction1 2 дні тому

      Hello po sa inyo. Una sa lahat, maraming salamat po sa tiwala at suporta sa channel. Hayaan po ninyo akong magbigay ng kaunting paliwanag regarding sa presented situation ninyo. Nararamdaman ko po kasi na mayroon pong kaunting confusion. Ganito po kasi yan. Ang building construction whether residential, commercial, industrial, o institutional ay ibinabatay mainly sa 2. Una po ay sa mga governing codes (National Building Code of the Philippines NBCP and National Structural Code of the Philippines NSCP 2015) at sa general construction practice. Ang mga code na nabanggit ang nagtatakda ng "minimum requirements" or "standards". Kapag sinasabi po na "Code", ibig sabihin, ito po ay bahagi ng batas (legal document) na kailangan natin sundin. Similar po ito sa Family Code, Civil Code, Labor Code, etc. Kaya po sinasabi ang salitang "requirements". Ang ika-2 po ay batay sa general construction practice. Ito po yung mga actual methodologies na nakasanayan na at satisfactorily accepted dahil ito po ay proven at tested sa site. Maaaring hindi po ito specifically stated sa alin man code pero ginagawa ito dahil ang mga license civil engineers ay required na magpractice ng profession in good faith. Kung mapapansin po ninyo sa mga video discussions ng Pinoy Construction channel, ang mga information ay mostly presented at delivered with basis from the code at maging sa general construction practice. Nagpe-present din po ako ng aking sariling recommendation. Kapag sinabi po sa video na ito ay "from the code", required po talaga na ito'y sundin regardless. Pero kapag sinabi po na "ang general practice..." o kaya ay "ang recommended practice...", hindi po ito requirement na kailangan masunod sa dahilan na ito ay maaaring hindi applicable sa isang paticular na project situation at condition. With that being said, sagutin ko po ng pranka ang tanong ninyo. Ang 100% rebar splicing ay allowed po ayon sa structural code. Wala din pong provision na nagsasabi kung saan particular ang location ng splicing sa column rebars. Hindi rin po specified na dapat hindi pantay-pantay ang splicing o ito yung tinatawag na splicing in a staggered manner. Ang meron sa code ay ang length of splicing, ang uri ng splicing, etc. In the absence po ng code provision, ang engineer must render a good professional practice. Ang nag-design po ng inyong structure must choose a better option/methodology. In short, siya po ang dapat na magtatakda ng requirements. Paano po ba ito? Ang isang general at recommended construction practice ay magiging requirement lang kung ito po naka-specify na sa contract documents katulad ng isang approved plan. Bigyan ko po kayo ng halimbawa. Sa code, ang minimum concrete cover po ng vertical bars sa column ay 40 mm. Kung naka-specify sa approved plan na 50 mm ang minimum, hindi po susundin ang 40 mm na nasa code kundi yung nasa plano. Mao-obliga lang po natin si foreman na gawin ang 50% total splicing, splicing in a staggered manner, at ang recommended splicing location sa column kung ipinalagay ang mga ito sa contract documents ng engineer na nagdesign. Usually, ito po ay makikita sa structural/general construction notes. Ako ay nag-aagree totally sa sinabi po ninyo na mayroon po talagang mga maling nakasanayan. Kadalasan ay nagiging excuse po yung mga salitang "matagal ko na itong ginagawa pero walang namang naging problema" o kaya ay "marami na akong naging karanasang ganito" upang tanggapin ang kanilang naging pamamaraan. Ang ating mga construction practitioneers tulad ng foreman, leadman, steelman, karpentero, mason ay kinakailangan pa rin i-supervise ng isang engineer. It is a pleasure to answer your inquiries. Maraming salamat po ulit sa tiwala at suporta.

    • @PinoyConstruction1
      @PinoyConstruction1 2 дні тому

      Hello po ulit sa inyo. Hindi po ako makakapag-comment po tungkol dito. Kung ito po ay dumaan sa engineering design procedure, at na-approved, nothing to worry about po. May mga na-encounter po akong column reinforcement na similar po dito sa isang approved plan.

    • @TheCanopyAirResidencesMakati
      @TheCanopyAirResidencesMakati 2 дні тому

      @@PinoyConstruction1 Hindi ko alam kung papaano kayo pasasalamatan❤️❤️This means alot po. Hitik na hitik sa kaalaman, detalye at naipaliwanag nyo ng napakalinaw para sa mga katulad ko. Maraming maraming salamat po muli Engineer sa sagot nyo, sa oras na binigay nyo sa pag tugon. Mabuhay po kayo❤️❤️

    • @PinoyConstruction1
      @PinoyConstruction1 2 дні тому

      Wala pong anuman. Very glad to help.

  • @SamuRai1984
    @SamuRai1984 3 дні тому

    ilang mm po ng rebar ang kailangan para sa footing? 2 storey house

    • @PinoyConstruction1
      @PinoyConstruction1 2 дні тому

      Hello po sa inyo. Check po ninyo itong isang video ng channel regarding sa foundation baka po makatulong sa inyo. ua-cam.com/video/VvXVtqD6O4c/v-deo.htmlsi=nOw6AT8cLGD6rFpg Maraming salamat po sa tiwala at suporta sa channel.

  • @dinomarquez-nb4rd
    @dinomarquez-nb4rd 3 дні тому

    hello sir, ok lang po ba ang 250x250cm na poste for 1 storey bungalow? 6pcs 12mm naka square type sya hndi sya naka 200x350mm . and ang distance po ng wall is nasa 4.70m ang column at isa ay nasa 4.3m . 9 Columns lang po sya sa 6.5x9mters na floor plan. Salamat po sa isasagot nyo

    • @PinoyConstruction1
      @PinoyConstruction1 День тому

      Hello po sa inyo. Ang recommended po sa bungalow ay 200mm x 350mm for column span distance na less 4m reinforced with 6-12mm rebars. Kung ang 250mm x 250mm po na sectional dimension ay adequate base sa engineering design, ok po yun. Basta nai-design po sya ng engineer, nothing to worry.

    • @dinomarquez-nb4rd
      @dinomarquez-nb4rd День тому

      @@PinoyConstruction1 Thank you, pero po kasi ung Haba ng bahay is 6.5x9 meters bale 9 columns lang sa design, ung pagitan ng columns is nasa 4.75m ung isa at isa nasa 4.25m po. Ok lang po ba un? 250x250 ung laki ng poste. pina design ko lang po sa pinsan ko na Engr.

  • @dinomarquez-nb4rd
    @dinomarquez-nb4rd 3 дні тому

    Hello po, tanong ko lang po, ang design po ng poste po ay 250x250cm pero ung distance ng 2 column is nasa 4.75m at ung 2nd is 4.25 cm , delikado na po ba? kasi lumagpas na po sa 4M ? salamat po, sana masagot. Single storey Bungalow house lang po, nasa 6.5x9meters ung floorplan

  • @dinomarquez-nb4rd
    @dinomarquez-nb4rd 3 дні тому

    ok lang po ba na 250x250cm ang Column sir? sqaure type hndi sya rectangular for Bungalow single storey po? thanks

  • @3AGCONSTRUCTION
    @3AGCONSTRUCTION 4 дні тому

    Salamat po

  • @Arnold-mo5xh
    @Arnold-mo5xh 4 дні тому

    Pls. explain thoroughly about the location of maximum axial compressive stress in columns, thanks for the explaination & good tutorial in construction methodology.

  • @charliegabriel9164
    @charliegabriel9164 7 днів тому

    sir ang ganda ng explanation with slide presentation

  • @charliegabriel9164
    @charliegabriel9164 7 днів тому

    very informative and base codes.

  • @barredobrothersofficial
    @barredobrothersofficial 8 днів тому

    Nice may Matutunan nanaman tayo

  • @user-yv1kg5yc4v
    @user-yv1kg5yc4v 11 днів тому

    Sir ok lang ba Ang distance ng poste sa 2 storey na bahay ay 5 meters? Yng bedroom ay 5meters x 5meters

  • @geni911
    @geni911 17 днів тому

    sir, ginamit ko yung estimate ni sir m.fajardo kaso ang layo ng difference nung computation nyo. Bakit po kaya ganun? since detailed yung procedure nyo sir mas kampante akong gamitin yung procedure po ninyo

    • @PinoyConstruction1
      @PinoyConstruction1 16 днів тому

      Hello po sa inyo. Sa natatandaan ko sa estimate book authored by Max Fajardo, kahit anong mix class, ang sand ay nakaset na agad sa 0.5 cu.m at ang gravel ay 1.0 cu.m. Hindi ako 100% sure. Hahanapin ko yung book na yun sa files ko. To make sure. Anyways, malaki ang allowance factor nya since kung io-observe mo yung staging at hauling ng materials, maraming natatapon. But it wouldn't favor the numerics of the estimate kasi lalabas maxadong malaki ang quantity na may significant impact costing.

    • @PinoyConstruction1
      @PinoyConstruction1 16 днів тому

      Pagbatayan mo pa rin ang estimate book nya. Nagpo-provide yun ng basics. Pati dib yung ibang books nya. Hanggang ngayon binabasa or nagrerefer pa rin ako sa mga yun. Maraming salamat po sa tiwala at suporta sa channel.

    • @geni911
      @geni911 16 днів тому

      @@PinoyConstruction1 regarding sa procedure ng estimate ni sir m.fajardo basta na lang kinuha yung volume nung required member and then multiply lang sa value na naka tabulate. Hindi na po sya gumamit ng dry volume. Dadgdag ko na din po sir, hingi lang po ako ng recommendations na book or article about sa class mix and standard thinckenss for conrete masonry and plastering. Hindi po kasi parep-pareho ang nababasa ko hindi ko po alam ano susundin ko.

    • @geni911
      @geni911 16 днів тому

      @@PinoyConstruction1 Salamat po sir sa pagshare ng knowledge sa tulad naming baguhan sa construction industry. Kampante po ako sa inaabsorb kung kaaalaman kasi pinapakita po ninyo na galing sa code ang mga tinuturo ninyo lalo na sa structural.

  • @geni911
    @geni911 17 днів тому

    Ganda ng explaination sir! Panatag ako sa knowledge na inaabsorb ko kasi sa nscp ang reference. God bless you sir!

  • @LionsHeart01
    @LionsHeart01 19 днів тому

    Hi po..mas maganda at matibay ba ang colunm sir kapag monolitic yung walang putol to 2nd floor po. Or mas recommended yung my putol? Please advise me tnx po sa sagot

    • @PinoyConstruction1
      @PinoyConstruction1 17 днів тому

      Hello po sa inyo. Hindi naman para maging matibay yung column kundi magkaroon ng enough rigidity/stiffness ang beam-column connection kaya recommended ang monolithic pouring from within H/4 ng column hanggang floor system. Hindi mo kasi maa-avoid ito dahil hindi advisable at dahil sa limitation na hindi mapopormahan ang buong column kasabay ang floor system. Maraming salamat po sa tiwala at suporta sa channel.

  • @randy4639
    @randy4639 20 днів тому

    Engr. Underrated mga videos mo pero napakadaming matututunan.

  • @cesardelacruz4593
    @cesardelacruz4593 21 день тому

    Sir subscriber nyo ko. Magpapa tulong lang sana ko kung mag kilala kayong structural engineer para ipa calculate ko yung size ng columns tsaka beams. Thanks

    • @cesardelacruz4593
      @cesardelacruz4593 18 днів тому

      Sir baka pwede mo ma compute yung size ng colums, beams, walls tsaka columns ng pinaplano kong ipagawang elevated swimming pool. Hingin ko sana yung number nyo kung pwede para pag usapan natin kung magkano bayad. Thanks

    • @PinoyConstruction1
      @PinoyConstruction1 15 днів тому

      Hello po sa inyo. Maraming salamat po sa tiwala at suporta sa channel. Paumanhin po sa inyo. Wala po ako sa Pinas. Hindi ko rin po magagawa dahil abala din po sa hanap-buhay.

  • @OffDutyAdventures.withyana
    @OffDutyAdventures.withyana 21 день тому

    Again thankyou for the knowledge idol, narerefresh ako sa mga provisions ng code dahil sa videos mo.waiting for part 2

  • @Seksyon14OfficialChannel
    @Seksyon14OfficialChannel 22 дні тому

    Ito ang pinaka the best mag explain, salamat engr.

  • @calicohadji-ali3040
    @calicohadji-ali3040 22 дні тому

    Bitin....longer video please.

  • @notsniwaez
    @notsniwaez 22 дні тому

    Pwede po kayang 2 columns lang yung gagawin for a 6meters wide? 3m x 6m po sana gagawin namin.. instead na 10mm bars gagamitan lng ng mas makapal?

    • @PinoyConstruction1
      @PinoyConstruction1 21 день тому

      Hello po sa inyo. Pwede naman po. Pero mag-increase po ang sectional size ng column at beam. Magrerequire din po ito ng larger bars o mas maraming bakal. Matutukoy lang po ito sa pamamagitan ng design.

  • @du30pro
    @du30pro 24 дні тому

    Sir , gusto ko pong mag pagawa sa inyo Ng structural plan Ng Bahay , mga rebars, plumbing ,electrical ,, paano kita nakuntak sir ,ang sukat na gagawing bahay 40x30 feet ,, single house lng po . Sana mapansin

    • @PinoyConstruction1
      @PinoyConstruction1 21 день тому

      Hello po sa inyo. Maraming salamat po sa tiwala at suporta sa channel. Paumanhin po sa inyo. Hindi na po ako tumatanggap ng project dahil wala na po ako sa Pinas. Paumanhin po ulit.

    • @du30pro
      @du30pro 21 день тому

      @@PinoyConstruction1 structural drawing lng Po , Kasi may balak Po Kasi Akong mgpagawa Ng bahay sa pinas , s ISA Po Akong OFW , DITO PO AKO SA EUROPE

  • @perfectodimaculanga1201
    @perfectodimaculanga1201 Місяць тому

    Bilang engineer, naaappreciate ko na may mga channel pa na nagbabahagi ng practical, safe at TOTOONG KAALAMAN, hindi yung "diskarte" lang. Malamang hindi ka puputok tulad ng ibang channels, you're too proper, too professional for that. Pero sana tuloy-tuloy lang.

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Maraming salamat po sa tiwala at suporta sa channel. Sa totoo lang, madalas nag-iisip ako na tumigil na sa ginagawa kong ito. May ilang attempt na rin na isara ko na itong channel dahil isinisingit ko lang ito sa busy schedule ko. Pero dahil nakakakita ako palagi ng pangangailangan sa kaalam ng ating mga kababayan, nareremind ako na hindi pa ako makakahinto. Ok lang kung hindi magboom ang channel. Ang nagiging trending videos po kasi sa ating panahon ay yung mga non-sense na. Masaya na po ako na makapagbigay ng kaunting kaalaman at professional opinion na libre lalo na dun sa mga nagko-consult na kababayan natin sa channel. Anyways, kilala ko po yung channel na sinasabi ninyong "diskarte" lang. Dahil sa kanya kaya ginawa ko po ang maling akala video tungkol sa paggamit ng hook sa footing rebars. Salamat sa kanya at mayroon naging quick content ang channel.

    • @perfectodimaculanga1201
      @perfectodimaculanga1201 Місяць тому

      @@PinoyConstruction1 Grabe, kalimutan na natin yung pambabastos/devalue sa larangan natin eh, kawawa yung mga nagpapagawa lalo na yung mga kapos sa budget. Sila yung may tendency na isacrifice ang safety para sa konting matitipid, and then after a couplle of years bitak, back job or worse giba. Ang standards dapat papataas eh. Ganunpaman, sana 'wag niyo burahin yung channel if ever wala na kayong time mag-upload. Sayang naman at for sure sa hinaharap may mangangailangan at makakahanap ng channel na'to.

  • @ak-47821
    @ak-47821 Місяць тому

    sir, ano po dahilan bakit kailangan i-extend ang cut bars beyond point of inflection? i think development length plays a role in here.

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Una sa lahat ay masaya po ako na nag-express kayo ng interest sa bagay na ito. Pero paumanhin po sa inyo. I-reserve ko po muna ang buong sagot sa isang video discussion. Maaaring mai-consider po ang development length as a reason. Ito ang common thinking ng most engineering practitioneers including po ako. Pero mag-iwan po ako sa inyo ng mapag-iisipan. Kung rebar anchorage o development length po ang reason kung bakit kailangan i-extend ang cut bars beyond the point of inflection, dapat ang sinabi ng code ay at least Ld ang amount ng extension. Pero hindi. Kundi ang prescribed length of extension stated sa ating code which is also presented in this video ay the greatest of the effective depth (d), 12x bar diameter (12db), or 1/16 of clear span (Ln/16). This leads us to think that development length is not the main reason but something else. Iyon po ang magiging topic natin sa isang mabuting pagkakataon. Maraming salamt po sa tiwala at suporta sa channel.

  • @user-le2fr8cd5e
    @user-le2fr8cd5e Місяць тому

    Sir.pwede ba ung beam ay 5pcs of 16 mm ksama ung cut bars

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Depende po ito sa overall design. Marami po kasing factors to consider. Personally po ang recommendation ko po palagi sa beam ng residential na ang span ay hindi hihigit sa 4m ay 6 na 12mm kasama cut bars tapos placed in two layers yung 4 main bars lalo na kung ang beam width ay 200mm lang. Siyempre factor din yung depth ng beam. Usually sa ganito, ang depth ay hindi bababa sa 350mm depende pa kung roof or floor beam. Para sa ganun hindi masyadong sikip ang horizontal spacing ng bakal kapag bubuhusan. Ano po ba ang desired beam width?

  • @uekihunter752
    @uekihunter752 Місяць тому

    Engr. Truss to column connection nman boss.... Ty

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Sige po. Isang magandang topic suggestion po ito. Maraming salamat po sa tiwala at suporta sa channel.

  • @Opetuss
    @Opetuss Місяць тому

    Sir ilang standard na posta ang dapat ilagay sa size na 5x7 35 SQM? Salamat po sa sagot.

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Hindi po natin masasabi kung ilan dahil hindi po dependent sa laki ng floor area ang dami ng poste kundi dependent ito sa overall architectural at structural configuration ng structure. As a guide, ang recommended ay magkaroon ng poste na ang center to center span distance ay hindi hihigit sa 4.00 m. The lesser the span distance the better. Maraming salamat sa tiwala at suporta sa channel.

  • @OffDutyAdventures.withyana
    @OffDutyAdventures.withyana Місяць тому

    Dami kong natutunan engr, salamat . Paano naman po kung steeldeck ang gamit maiiba din ba ang required steel bars?sana mapansin idol

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Ang paggamit po ng steel deck o metal deck ay hindi para mabawasan ang required na dami ng reinforcing bars sa pamamagitan ng pagluwang ng spacing o di kya naman ay liitan ang size para sa suspended slab. Ang main purpose po ng paglalagay nito ay para ma-control at ma-reduce ang vibration at deflection o paglundo ng slab kapag nilalakaran ito dahil sa added stiffness provided ng rib profile ng steel decking. Isa ito sa mga misconceptions sa construction sa ating panahon na nagti-trending. Personal opinion ko lang po ito. Ang best application nito ay sa mga mezzanine or upper floor level ng low-rise commercial structures o industrial facilities upang magkaroon ng option na ma-eliminate ang ceiling assembly at makasunod sa floor to ceiling clearance as dictated by the building code. Kapag ginagamit ito sa ganitong building occupancy, usually ito supported ng open web steel joists kung saan libreng libre ang mechanical, electrical, plumbing and fire (MEPF) utilities na lumusot sa open web steel joist ng walang abala. Hindi ko po ito recommended sa suspended slabs ng multiple-storey residential kung hindi maglalagay ng ceiling assembly. Nagiging trend na po kasi na ini-eliminate na ang ceiling kapag nagkabit ng steel deck sa bahay sa ngalan ng pagtitipid. Ang nagiging issue ay wala ng pangtakip kung mayroong plumbing pipes and utilities na dumadaan sa ilalim ng beams at suspended slab. Ang remedyo ay i-divert ang mga ito kung saan saan to the extent na palusutin ito sa poste at biga na nakakaapekto sa overall strength at performance ng structural members. Hindi po ito ang standard construction practice. Paumanhin po sa kahabaan ng sagot. Maraming salamat po sa tiwala at suporta sa channel.

    • @OffDutyAdventures.withyana
      @OffDutyAdventures.withyana Місяць тому

      @@PinoyConstruction1 maraming salamat engr.

  • @jasonguillermo4996
    @jasonguillermo4996 Місяць тому

    Part 2 please.😊

  • @zariej3712
    @zariej3712 Місяць тому

    Napansin ko valuable po yung mga video niyo sir, kayo lang yung nakakapag explain ng may maayos na may magandang visuals dito sa UA-cam kasi halos 3 days nako naghahanap ng mga ganitong discussion na based sa NCSP Siguro hindi po kayo full time sa UA-cam kaya matagal po yung upload?

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Maraming salamat po sa tiwala at suporta sa channel. Kahanga-hanga po ang inyong power of observation. Isinisingit ko lang po kasi ang pag-upload ng mga topics sa aking busy schedule. Gagawin ko po ang lahat ng makakaya upang makapag-upload po agad. Pagtiisan na po sana ninyo ang kabagalan.

  • @gnidnoeled786
    @gnidnoeled786 Місяць тому

    Ang critical section in a footing po ba ay nasa face of the column? Kaya diyan po ba ang simula ng pagkuha ng tension Ld?

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Depende po ang location ng critical section ng bending o flexural stress ng footing sa sinusuportahan nito. Pero sa column footing, ang critical section ay nasa face of column. Binanggit po ang code reference sa part 1 ng videong ito. Section 413.2.7.1 at tabulated sa Table 413.2.7.1. Ang rebar anchorage (development length) Ld or Ldh taken from the critical section going to the edge of the footing sa limit ng concrete clear covering.

  • @user-dz6re3kh1d
    @user-dz6re3kh1d Місяць тому

    Sir paano ang ilayout ang bahay na nasa labas ang nossing may napanood kase ako may 3 udjustment silang ginagawa pero diko parin maintindhan

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Sa opinion ko po ay pareho lang ang procedure. Kung maaari po sana ay maibigay po ninyo sa akin yung link nung napanuod ninyo para ma-check ko po.

  • @al-kairimukalil9283
    @al-kairimukalil9283 Місяць тому

    Very informative vid especially sa mga tulad ko CE student, Thank you Engr ! Keep uploading more vids

  • @hendrixxhermosa5523
    @hendrixxhermosa5523 Місяць тому

    Gud day po sir, ilang sqr meters po sa slab bago mg lagay ng biga at ilang centimeters ang kapal ng slab na pang roofdeck single storey. Salamat po

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Hindi po dependent sa laki ng area ng slab para maglagay ng biga. Mayroon pong floor system na ang slab ay directly supported ng poste. Walang biga. Mayroon naman na kailangan ng biga pero walang slab like in the case of roof beam ng mga single-storey house o bungalow. Depende po ito sa chosen floor system configuration selected by the designer. Isang bagay pa. Iko-consider din ang bending behavior ng slab kung one-way or two-way slab. Mas marami ang biga na inilalagay sa one-way kaysa sa two-way slab. Ang recommended thickness ay 100 mm sa one-way at 125 mm naman sa two-way. Maraming salamat po sa tiwala at suporta sa channel.

  • @CrestFlpe
    @CrestFlpe Місяць тому

    Engr. paano po Yung document na as-staked plan?

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po sa inyo. Ang tinutukoy po ba ninyo yung guidelines from DPWH?

  • @Etingponce
    @Etingponce Місяць тому

    Thank you very much Sir, of sharing your knowledge and very informative type of construction procedures and structural standards. Stay safe always and God bless.

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Thank you for trusting and supporting the channel. May God bless you as well.

  • @EngrValchi
    @EngrValchi 2 місяці тому

    thanks for the very informative video sir. May i ask po what is the effect of the abovementioned location of COLUMN'S construction joints on the overall performance of the building given that our structure must be built to have a strong column - weak beam behavior?

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello Sir. In general, construction joint reduces the shear load carrying capacity of a reinforced concrete member. In columns, it can affect the seismic performance of a building structure. Strong column - weak beam behavior on the other hand is just a term given to an intended design failure in which vertical structure like buildings are designed to fail in a certain manner that will give the occupants a good chance of survival in the event of a collapse. This intended failure simply means that in vertical structures, columns are designed to be much stronger as compared to beams. In this regard, failure is most likely to happen in beams than in columns, resulting the structure to remain still standing for a time. Such time can be crucial or an opportunity for occupants to leave the damaged structure and escape to safety. Construction joints are unavoidable. Having these does not mean that columns are less stronger than floor/roof system ( beams and slab) having no joint.

  • @MarkJosephSuarez
    @MarkJosephSuarez 2 місяці тому

    Gaanu po kalayo po ang maximum na disgansya ng poste ng two storey residential po

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Hello po sa inyo. Depende po ito sa structural configuration ng design. 4 m or less po ang recommended maximum span distance on a certain column cross sectional dimension. I-check po ninyo ang part 1 ng xomun standards para sa details. Maraming salamat po sa tiwala at suporta sa channel. ua-cam.com/video/JAD13AB9wSs/v-deo.htmlsi=madeN3m2TBkhRKwp

    • @MarkJosephSuarez
      @MarkJosephSuarez Місяць тому

      Pwede po bng mas humaba halimbawa 5meters

    • @PinoyConstruction1
      @PinoyConstruction1 Місяць тому

      Hello po ulit sa inyo. Pwede naman po. Kahit 10m ay pwede depende po sa overall structural configuration. Dahil dito, magkakaroon ng increase sa cross-sectional dimension ng beam, column at possibly ang area at thickness ng column footing. Maaari ring madagdagan ang size at dami ng steel reinforcement. Ito po ay matutukoy sa pamamagitan ng design.

  • @domingodelarosa485
    @domingodelarosa485 2 місяці тому

    Thank you for instruction building construction

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Thank you for trusting and supporting the channel. May you have a wonderful day.

  • @jaycrisgenota4484
    @jaycrisgenota4484 2 місяці тому

    Thank you po sa informative video po

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Maraming salamat po sa tiwala at suporta sa channel.

  • @user-tg6xu5sf2t
    @user-tg6xu5sf2t 2 місяці тому

    wow! ang ganda ng pagkakapaliwanag. all ears sir!

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Maraming salamat po sa tiwala at suporta sa channel.

    • @user-tg6xu5sf2t
      @user-tg6xu5sf2t 2 місяці тому

      @@PinoyConstruction1 maraming salamat din po sa masustansiyang kaalaman

  • @calicohadji-ali3040
    @calicohadji-ali3040 2 місяці тому

    Very educational kahit hnd ako engineer. Thank you engineer.

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Maraming salamat po sa tiwala at suporta sa channel.

  • @francisbarona8513
    @francisbarona8513 2 місяці тому

    Thankyo for thisss

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Maraming salamat po sa tiwala at suporta sa channel.

  • @richardneile.salalima54
    @richardneile.salalima54 2 місяці тому

    thanks po sir

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Maraming salamat po sa tiwala at suporta sa channel.

  • @yourtestedtrustedelectrici7201
    @yourtestedtrustedelectrici7201 2 місяці тому

    Ano po standard na bilang Ng rebars for 3 storey building?

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Hello po sa inyo. Wala pong standard na nagsasabi kung ilan ang bakal na dapat ilagay sa isang particular na multi-storey building. Depende kasi ito hindi sa kung ilang grado kundi sa ilang factors tulad halimbawa ng overall configuration ng structure. Malalaman lang ito sa pamamagitan ng design.

  • @1989ENgVic
    @1989ENgVic 2 місяці тому

    nscp 2015 copy lang nman yan sa aci.

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Hello po sa inyo. Paumanhin po sa inyo pero correction lang po. Ang Chapter 4 ng NSCP 2015 ang masasabing copied kung iyon po ang gusto ninyong itawag pero mas prefer ko na sabihin na referenced or adopted sa ACI. Ang ibang chapters nito katulad ng Chapter 5 - Structural Steel, Chapter 6 - Wood or Chapter 7 - Masonry ay hindi po kinopya sa ACI kundi sa ibang American standards. Hindi naman po masama na kopyahin ang halos entirety ng ACI standards dahil siguro sa preference ng ASEP na mas applicable ang system na ito para sa Pinas, considering ang malaking collection of research study and development nito when it comes to reinforced concrete technology.

  • @stevendy2443
    @stevendy2443 2 місяці тому

    Sir paanu po kung ang lapping ng lahat vertical bars at nasa part na ng biga? Anu pwede gawin para maging safe sya?

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Hello po sa inyo. Hindi po pinapractice ang paglalap-splicing ng column verticals sa beam-column joint. Ito po ay common na naka-specify sa general construction notes ng structural plans. Maiiwasan ito kung accounted ang staggered location ng splicing sa rebar cutting schedule na ginagawa at sinusupervise ng engineer. Hindi ko po masasabi kung ano ang pwedeng remedyo kung sakaling ang spliced vertical bars ay pumatak sa beams dahil hindi ko po nakikita ang overall condition ng structure. It is recommended na i-consult po ninyo ito sa engineer particularly sa structural engineer. Maraming salamat po sa tiwala at suporta sa channel.

  • @kebzkebz3110
    @kebzkebz3110 2 місяці тому

    MALI po yung H/4 below the Girder. Sa Soffit po ng Girder ang Tamang Putol ng Concrete.

    • @LionsHeart01
      @LionsHeart01 19 днів тому

      His sir..mas maganda ba ang colunm kapag monolitic to 2nd floor or mas ok yung may putol h/4?

    • @kebzkebz3110
      @kebzkebz3110 18 днів тому

      @@LionsHeart01Ulitin ko po, Hindi po dapat sa H/4 ang Putol. Sa Soffit po ng Girder ang Tamang location.

    • @PinoyConstruction1
      @PinoyConstruction1 18 днів тому

      Hello po sa inyo. Maraming salamat po sa pagtangkilik sa channel. Just for the purpose of information para na din sa benefit ng mga nagbabasa ng mga comments. Ano po ang naging reference nyo para sabihin na MALI yung putol sa H/4? Kung hindi po ako nagkakamali, ang sinabi sa video ay WITHIN H/4 or less than H/4. But just the same, saan po ba sa NSCP makikita yun. Na sinasabi na ang putol ay dapat at required sa soffit ng beam. Just like a learner, willing po ako tumanggap ng correction at babaguhin ko yung nasa video kung mali ang information. Para sa kapakanan ng mga viewers.

    • @kebzkebz3110
      @kebzkebz3110 17 днів тому

      @@PinoyConstruction1 Sa Project namin Previously with Saudi Aramco, ganito ang required. Meron kaming Saudi Aramco Standards na sinusunod, and ito ay lahat Referenced sa ACI codes or BS Code. Although hindi na ginagamit ngayon ang BS code dahil Europeaen Standards na ang ginagamit. BAGO ka Sana magPost ng video, Ginagawan muna ng Thorough Research. Dahil Napakaraming Manonood na First time lang Makakita ng Ganito and Wala pa Idea Tulad ng mga Estudyante ng Civil Engneering.

    • @PinoyConstruction1
      @PinoyConstruction1 17 днів тому

      Paumanhin kung hindi ko po ginagawan ng thorough research bago ako magpost ng video according sa iyo. Sa naging project ninyo sa Saudi Aramco, ang standards kamo na sinunod ninyo ay lahat referenced sa ACI codes or BS code. Huwag na natin isama yung British Standard. Yung ACI code na lang. Ang Chapter 4 - Structural Concrete kasi ng NSCP 2015 in its almost entirety ay adopted sa ACI. Ang tanong ko. Saan sa ACI Code 318, bahala na kyo kung metric or imperial version at kung anong published year mababasa na REQUIRED ang putol ng buhos (construction joint) ng column ay dapat nate-terminate sa underside/soffit ng beam?

  • @user-sq9iz6bs5x
    @user-sq9iz6bs5x 2 місяці тому

    sir..urgent answer po sa question po..kapitbahay po nmin ai inihiga po Ng paglagay ng mga bakal beam..safe po ba un…?kung ganun n po ang ginawa may remedy po ba sa ganun?

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Hello po sa inyo. Hindi ko po nakuha ang tanong. Paanong inihiga ang paglagay ng bakal sa beam?

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Ang ibig mo bang sabihin yung deeper cross sectional dimension ang naka-parallel sa direction ng foor slab?

    • @user-sq9iz6bs5x
      @user-sq9iz6bs5x 2 місяці тому

      @@PinoyConstruction1 ung 20x40 beams nia po naging rectangle ung pagpatong nia sa hallow blocks..naging height nia is ung 20

    • @PinoyConstruction1
      @PinoyConstruction1 2 місяці тому

      Tama nga ang hinala ko. May mga gumagawa talaga na ang beam ay pahiga. Hindi ko po alam kung ano ang objective ng kapit-bahay nyo bakit sa ganun ang pagkakalagay niya. Pero ang practice at proper way po ay patayo ang cross-section ng beam para hindi po masyado ito lumundo. May mga beam kasi na kahit lundo or sag na masyado ay safe pa rin. May malaking epekto nga lang sa function ng mga pinto o bintana o anumang element sa ilalim nito. Maaaring hindi maisara o maibukas ng tama at maayos dahil maaaring tumabingi ang frame ng mga ito.

    • @user-sq9iz6bs5x
      @user-sq9iz6bs5x 2 місяці тому

      @@PinoyConstruction1 ang sabi sa akin sir tinangal n nila ung foreman n gumawa..wala po itong engineer or architect..pero may plano sia..pero hindi po ito sinunod sa kung ano ang nsa plano nia..may existing n bahay po kc sia at pinagpatuloy lang pra gawing 2nd floor..