- 33
- 246 867
Mike Test
Приєднався 13 лип 2018
Electro Mechanical Machineries
Відео
Car A/C leak test and charging
Переглядів 3102 роки тому
Quick guide in finding system leak and refrigerant charging procedure.
Manifold & Car AC tutorial
Переглядів 3962 роки тому
Familiarization to refrigeration manifold set and basic car AC refrigerant charging procedure.
ALTERNATOR & AVR (PART 4)
Переглядів 11 тис.3 роки тому
FOR A DETAILED TECHNICAL KNOWLEDGE ON ALTERNATORS AND DIFFERENT TYPES OF AVR'S, CLICK SUBSCRIBE AND LEARN THE MOST IN-DEPTH TOPICS AND DISCUSSIONS WITH SHUTTLE MARINE ENGINEERING SERVICES & TRAINING CENTER.
ALTERNATOR AVR PART 3
Переглядів 11 тис.3 роки тому
UNDERSTANDING ABOUT AVR VOLTAGE TRIMMERS AND REMOTE VR/VAD
ALTERNATOR AVR (PART 2)
Переглядів 48 тис.4 роки тому
ACQUIRE SUFFICIENT TECHNICAL KNOWLEDGE REGARDING ALTERNATOR AVR FROM SOMEONE WHO HAD VAST EXPOSURE TO THE MARINE SHIP REPAIR INDUSTRY FOR OVER 30 YEARS.
FUNCTION OF ALTERNATOR A.V.R.
Переглядів 166 тис.4 роки тому
FAMILIARIZE WITH THE FUNCTION AND OPERATION OF AVR IN ALTERNATOR SYSTEM, SEE HOW IT REACTS AND HAVE A BRIEF UNDERSTANDING OF SOME OF AVR'S ELECTRONIC SYSTEM BLOCK.
MARINE EMT 5.1 (Electro Mechanical Training)
Переглядів 1,6 тис.4 роки тому
6 Days (48hours) of Actual Facilities Training 20 hours of Online Training 24/7 Technical Support (for 1year) = Concise and truly worth every penny. The one and only marine training center in South East Asia with 30 years of ship repair experience instructor...WORLD CLASS!!!
MARINE EMT 5.0 (Electro Mechanical Training)
Переглядів 6464 роки тому
5 days of trainings on various marine machineries & equipments.
MARINE HP 2.0 (Hydraulics & Pneumatics)
Переглядів 2254 роки тому
MARINE HP 2.0 (Hydraulics & Pneumatics)
Marine EMT 5.1 (Electro Mechanical Training)
Переглядів 5004 роки тому
6 Days of intensive and concise marine trainings with actual and internally developed equipments, machineries and simulators. With our vast global ship repair experience and more than 15,000 work orders completed, you’ll definitely be mentored by the best. Marine EMT 5.1 is a mixed training of the most critical and important machineries onboard, nothing is more rewarding than being able to perf...
DIRECT TO THE POINT...SAPUL KAAGAD!!!
Переглядів 1124 роки тому
Direct to the point training approach, Marine Electro-Mechanical Trainings from theory and from our tons of actual ship repair experience. Shuttle Marine, probably the most concise trainings you’ll ever experience...WORLD CLASS!!!
IMPRESS YOUR SUPERIORS & IMPRESS THE WORLD!!!
Переглядів 1904 роки тому
Even veteran ETO‘s & CE’s were amazed to the amount of technical knowledge that they gained from Shuttle Marine, the one & only Marine Electro-Mechanical Trainings with 30 years of International Ship Repair Experience Instructor. Shuttle Marine, creating new breed of marine ETO’s and marine engineers...WORLD CLASS!!!
MARINE RAC 3.0 (Refrigeration & Air Conditioning)
Переглядів 1,7 тис.4 роки тому
MARINE RAC 3.0 (Refrigeration & Air Conditioning)
Marine ASLS 3.0 (Alternators, Sychronization & Load Sharing)
Переглядів 1 тис.4 роки тому
Marine ASLS 3.0 (Alternators, Sychronization & Load Sharing)
ANG ULO NG MGA BALITA, UNLI-LEARNING!!!
Переглядів 1494 роки тому
ANG ULO NG MGA BALITA, UNLI-LEARNING!!!
FROM CURIOSITY TO DISCOVERING THE REALITY...SULIT NA SULIT!!!
Переглядів 1394 роки тому
FROM CURIOSITY TO DISCOVERING THE REALITY...SULIT NA SULIT!!!
C.E. SAVING TIME, MONEY AND EARN RESPECT FROM SHIP OWNERS
Переглядів 894 роки тому
C.E. SAVING TIME, MONEY AND EARN RESPECT FROM SHIP OWNERS
SHUTTLE MARINE TRAINING EXPERIENCE BY A NIGERIAN NATIONAL
Переглядів 1094 роки тому
SHUTTLE MARINE TRAINING EXPERIENCE BY A NIGERIAN NATIONAL
Marine Alternator, Synchronization & Load Sharing ASLS 3.0
Переглядів 3054 роки тому
Marine Alternator, Synchronization & Load Sharing ASLS 3.0
MARINE ELECTRO-MECHANICAL TRAINING 5.1
Переглядів 1554 роки тому
MARINE ELECTRO-MECHANICAL TRAINING 5.1
Marine ETO and Marine Engineer Training
Переглядів 1734 роки тому
Marine ETO and Marine Engineer Training
AVR ka voltas kam kaeyse kareyn
Good morning boss paano mag adjust ng Herz sa Genset
@@technowatercornervlogs. Good day sir, frequency is based on 2 factors. Engine RPM at yung number of poles ng alternator which is fixed. (Poles x RPM/ 120 = Hz) sa pinas 60hz tayo. Kung maliit yang genset kasi mostly 2poles kaya (2P x 3600rpm/120 =60hz) kung malaki naman usually nsa 4poles (4P x 1800rpm/1800 =60hz) pero meron din sa barko na brands such sa hyundai, taiyo, nishishiba is 8poles (8P x 900rpm/120 = 60hz. From these examples makita mo sir na yung poles ng windings fixed yan nde yan pwedeng mabago at yung 120 is given yan (time) kaya meaning if magbago Hz meaning mabagal or mabilis yung RPM ng prime mover (makina). I hope may natutunan ka sir dito. Thanks
What is the notmal output sir of the avr without load connected?
Voltage output of AVR without load has different values based on brand and capacity. Some has only 6vdc & some has 15vdc @no load. Whats important to consider is that the Voltage output is proportional to the loading conditions. I hope this answers your question. Thanks
Can I ask some questions?
Hi ser How do you get over voltage of output 90v to 150v is that ok??
Someday sana makapag training po dito sir sa training center nyo..watching po from JUBAIL KSA.
Galing nyo po sir..salamat sa mahalagang info po.
Thank you so much
Make up your mind what language your speaking😂
Sorry mate, but this was made specifically for Filipinos only, so fortunate that we can speak both tagalog and english. To those who appreciates my posting thanks alot. Cheers mate🍻
@@shuttlemarineengineering no worries. There are too few alternator function videos in English, very difficult to find.
I am Shimelis from Ethiopia(East Africa) and Your videos are very informative but please make it in full English language so that people from other countries also can understand fully.
Automatic Language Regulator please
Yes it is compatible.
sir gud pm paano kung ang output nya sa pag start at walang load ay nasa 75vdc na?umiinit kasi ang exciter field at di maadjust ang voltage.sira na ba avr ko
Good PM sir, based sa informations mo sir. May probability na sira AVR, ask ko lang sir meron ba yan remote V adjustment sa switchboard? If meron need muna ma check if ok connection at nde open yung potentiometer, pwede din kasi mag cause ng high V ang AVR pag may open lines towards remote V adjustment at kung dun ka mag adjust wala din V reaction. Pero if ok naman yun at yun AVR wala naman fuse then I can confirm na AVR lang talaga issue nyan. Thanks
But why for god sake mix that gibberish and english?
Hi I from Singapore,May I know where can I get Leroy somer AVR D350 kit
I HAVE AN AVR SX460 INSTALLED ON A 220V GENERATOR. BUT NOW IT IS GENERATING 360 V AND IT DOES NOT TAKE ADJUSTMENT BY THE VOLTAGE POETENTIOMETER. I ASK YOU: IS IT A PROBLEM WITH THE AVR CARD OR IS IT AN INTERNAL PROBLEM. BECAUSE THE CARD LOOKED GOOD
SX460 max input in 264V only and it’s receiving 360v and since this avr’s does not have fuses then your avr is probably gone. Check excitation V how high is it and from there you can confirm that you have a defective AVR. Damaged rotating diodes or burnt winding wont show a high voltage, instead it produces a very low V. Thanks
MY AVR GAVE AT MAXIMUM RANGE, THE GENERATOR IS 220 V AND GENERATES 355 V. IT DOES NOT ADJUST BY THE VOLTAGE POTENTIOMETER. WHAT WAS DAMAGED?
What is the brand and capacity of the alternator?
IT IS A CARD EQUAL TO THE STAMFORD, BUT UNIVERSAL. MY QUESTION IS: WHAT COMPONENT WAS DAMAGED TO THE CARD SO THAT IT DOES NOT REGULATE THE OUTPUT AND IS AT MAXIMUM RANGE
@@teloexplicaeldiamante2855 Hard to know which electronic component gave up, but based on your info’s it’s on the regulation circuitry. But if fitted with remote V adjustment is suggest you check if it’s open or if connection from potentiometer to avr if not broken or loose. A loose remote V potentiometer also causes high V output. If no remote then AVR is defective. Thanks
How can I convert maccalte AVR to work with Stamford AVR
What is the alternator output V rating and check nameplate what is the excitation V. From there it can easily be determined what brand and type of AVR can be used. Thanks
paano din po pag hindi na nae'excite yung avr? hindi na po kasi nari'reach yung designated voltage na kailangan
Ano brand sir?
Yung machine alternator is connected ba sa avr? please notice sir. thank you
Yes, it must be connected to the stator winding for sensing purposes and output to exciter field. Thanks
Good video. But it would be great if you just picked one language and stuck to it. Preferably English.
👍👍👍👍👍👍
Good luck sir 🎉
Good day sir. may I ask you about some ideas regarding Alternator AVR . what will happen if the AVR will encounter some unexpected trouble. how it affects the operation . ? thing as I have observed.
Good day, you cant set the rated V or it will not sustain the V once genset take the electrical load. AVR, A acronym stands for Automatic, then AVR should react to whatever loading conditions, if its defective then V will not be sustained and therefore produces a high current that will either trip the breaker or burn windings or blew up diode/s in the rotation diodes. Hope this answers your question. Thanks
Can an AVR be added to a brushed generator with capacitor regulation?
Important is the AVR will match the excitation voltage & current of the winding field. So check the alternator nameplate if it mentions about the excitation V & I, your AVR output must be higher than those values otherwise it will damage your AVR. Thanks
Nice video sir, sir myron po kaung training center, thanks and godbless po
sir pwd ba makahingi ng contact no. mo, nag hahanap kz kmi ng mag bgay samin ng training
Kindly email us at perl.shuttlemarine@gmail.com and we’ll coordinate with you accordingly. thanks
LA TENSION d'exitation avr as480 est de combien de volts DC
Sir ano massenger mo. Pm kita dirik
Sir good day meron lang akong tanung kung merong input voltage na AC pero walang Output na voltage na DC anu po yung mga dahilan.
Good day, based sa info na AC input available but no DC output is a defective AVR. Thanks
Pwedi po ba yong dalawang generator na hindi pareho ang rated power?
Pwede yan sir aslong as not too huge capacity difference, important to note na they should have the same hz and exactly the same V at whatever loading %. Thanks
Sir.. mike pwedi nyo po ba magawan ng video yong sa load sharing at paralleling requirements para sa dalawa or more generators.. thanks
Kayo po yata professor ko dati.. 👍👍👍 sa DTC..?
Super liwanag po.
Sir Mike.. ask ko lang po kung YAp apelyedo nyo?
Sir thank you sa MGA turo mo. Tanong ko lng po Kung among AVR na mas maganda ikabit sa 1125kva Stamford...may naka install po UNG 15amp po UNG fuse. Kasama sa AVR. TY PO.
Need to check ilan excitation coil resistance para malaman if pwede dyan at kung yan bang genset nde ginagamit on load sharing. Thanks
I have 375kva nta855-g1 genset for poultry use. .the problema low herts low l-l low l-n kw low and shot down engine. .what is the problem sir can u advice me what is the probs of my genset 365kva
It really depends on the engine shutdown protection naka install sa system. But based sa info mo sir, low Hz means mabagal andar ng prime mover kya low L-L and L-N din yan definitely. Check na lang ano issue sa governor, fuel lines or other mechanical parts that is causing the RPM nd ema meet rated. If its 4poles yan 1800rpm Im assuming 4 poles windings. Thanks
good job master subscribe done
Please as good and informative as the video was do an English language version for those that don't understand the language used here.
me, too
Me too
Marami ng Salamat po Sir Baguhan lang ako Maintenance Technician Daming ko dn na tutunan
May tanong lang ako sir about sa generator namin after ma synchronize sa automatic mode in 10 minutes bigla nalang babagsak yng rpm at frequency ano kaya cause sir kasi pag ilagay sa manual mode ok naman
Definitely wala yan sa AVR, since nsa RPM problema check mechanical side or check speed controls and other related electrical protections. Thanks
translation please
Sir mag kano po etr training?
Thanks
Damn I understood 15% of this. The English parts. Thanks for the attempt and effort though.
nice sir,, sir ask ko lng ung genset namin bumagsak ung out put voltage ng halos kalahati 400v naging 237 v nlng tas herts naging 33 nlng.. tas sa rpm walang dispaly puro number sign ####. posible ba avr my problema non? tnx
Initially need to check prime mover, kasi mababa rpm and this will result to low V aswell. Thanks
sir my tanong poh ako meron akong genset na 15kva after ako nag palit ng universal avr walang out put na lumalabas piro kapag kinalabit ko yung J K saka pa sya nag wo work
Thank you so sir . Good bless you
Sir good day may generator po akong kinabitan ng AVR. GB170 po yung avr para po sa STC na mindong dynamo po. Ang problem po hindi po naaadjust yung voltage nya sa avr. Yung connection ko sa UVW ok naman po. Dun sa Dalawang Z po sinunod ko naman yung diagram base dun sa manual. Ano po kaya problem sir.? Thanks po
Good day sir, yung mindong genset kasi basically brush type and walang exciter field and exciter rotor. Yung output ng stator na U-V-W dun din kukuha ng voltage input yun GB170 na avr, make sure tama yan, yun naman feed sa main field dadaan lang sa trio bridge diodes pra yung 3phase AC from a separate coil group ng stator papunta na main field maging DC volts, pero yung 1 line from stator daan muna sa avr terminals labels Z - Z pra ma regulate yun DC na feed sa main field. Kung maka download ka ng PDF ng manual then balikan mo itong explanation na ito mas maintindihan mo yan. I hope makatulong sa iyo sir. Stay safe
Sir anong pwedeng AVR sa brush type generator like mindong? 20kw po. Thanks