Chief Officer Ye Nyein Kyaw ( Master F.G)
Приєднався 30 лип 2021
I have been sailing on Oil/Chemical Tanker Vessel for more than 20 years and 8 yrs in Chief Officer rank.
Onboard Chief Officer practical job videos will be uploaded here.
Your likes and sunscribal would encourage me to post further knowledgeable video.
Onboard Chief Officer practical job videos will be uploaded here.
Your likes and sunscribal would encourage me to post further knowledgeable video.
Let's find out what all we can see inside the Ice Class Tanker Bow Thruster Room.
Let's find out what all we can see inside the Ice Class Tanker Bow Thruster Room.
Переглядів: 50
Відео
RX-8000 KEIKEN KEIKI Fail Low Flow Error Removal procedures as per Maker Instructions
Переглядів 759 місяців тому
RX-8000 KEIKEN KEIKI Fail Low Flow Error Removal procedures as per Maker Instructions
How to remove Fail Low Flow Error in REIKEN KEIKI (RX-8000) Gas Detector as per Maker
Переглядів 4549 місяців тому
How to remove Fail Low Flow Error in REIKEN KEIKI (RX-8000) Gas Detector as per Maker
REIKEN KEIKI (GX-2009) Sensor Date Code checks
Переглядів 519 місяців тому
REIKEN KEIKI (GX-2009) Sensor Date Code checks
Gas Detector Mfg. Sensor Date Reading (GX-8000) REIKEN KEIKI
Переглядів 3039 місяців тому
Edited by VideoGuru:videoguru.page.link/Best
ODME -S3000 (KSB) Print out procedure
Переглядів 10611 місяців тому
ODME -S3000 (KSB) Print out procedure
ODME-S3000 (KSB). Monthly Simulation Test
Переглядів 476Рік тому
ODME-S3000 (KSB). Monthly Simulation Test
Nice Content
@@MoeMyintShein_MMU Thanks a lot Sir
Welcome and thank you for the explanation of calibrating the device. I have a new device and I installed it, but when calibrating it, calibration fail appears in the calibration. Are there steps to adjust the sensors?
Welcome and thank you for the explanation of calibrating the device. I have a new device and I installed it, but when calibrating it, calibration fail appears in the calibration. Are there steps to adjust the sensors?
There are a couple of reasons in calibration failure. Mostly 1.Wiper deteriorating/ replace with new one or if fall down/need to open and fix it back. 2. Projector light dim /to replace with new one. 3. Check Pneumatic Valve positions 4. Check the connections between cell block and Oil content meter. In my case, Optical fiber sensors in oil content meter are found dirty with small particles which cause the calibration failure.
perfect!!! thank you so much chief 감사합니다!!!!
Very helpful information sir. Thank you.
Thank you sir
You're welcome bro.
Nice Bro. Keep it Up.
Thanks for your support Sir bro.
Thanks ,Sir Ye
All the best
Do you know how to remove the problem that keeps flashing the lack of calibration information?
Have you done the calibration bro? If you did and passed, no alarm should come.
Do you have a step-by-step guide on how to do this?
That's how we do step by step bro. Do you mean setting up the lines on the deck where ODME unit installed?
Do you have a step-by-step guide on how to do this?
Manual calculation Formula for Instantaneous Rate of Discharge (in ltr/Nautical mile)= Oil content (ppm) x Flow rate (m3/hr) / Speed (Knots) x 1000