budget Brian repair
budget Brian repair
  • 18
  • 19 283
New York Botanical Gardens Holiday Train Show 2024.
New York Botanical Gardens Holiday Train Show 2024. It's a good place to get in the Christmas spirit when you're in NYC.
Переглядів: 171

Відео

Tie Rod End changed without ruining the alignment.
Переглядів 290Місяць тому
Cadillac CTS outer tie rod end replaced. How to keep the car in alignment.
2003 Cadillac CTS Rear Brake Replacement.
Переглядів 212Місяць тому
2003 Cadillac CTS Rear Brake Replacement. Rotors and Pads.
Do Gutter Guards Work. Plastic Mesh Gutter Guards Review.
Переглядів 2186 місяців тому
Plastic Mesh Gutter Guards. You won't get a gutter full of leaves, but that doesn't mean you won't have to clean them. Watch this short video and see for yourself.
April 4, 2024
Переглядів 378 місяців тому
Home Depot Truck 🚛 rental review and size of truck. I moved a 1 bedroom apartment, except for a sofa which was disposed of.
Glass in my Polaner All Fruit!!!🤢
Переглядів 9Рік тому
Glass in my Polaner All Fruit!!!🤢
How a boiler Zone Control Valve works and a review of a Kazeffi Motorized Zone Valve.
Переглядів 276Рік тому
Review of Kazeffi zone valve, How a Zone valve works, honeywell Zone Valve
Oil Boiler Tune Up
Переглядів 2,4 тис.Рік тому
An overview of how to tune up a boiler. Replacing the filter, strainer, and the nozzle. Also brushing the heat exchanger clean. I'm using the same size nozzle and not making any adjustments to the air shutter. Therefor test equipment is not necessary, but I would recommend have a professional check your work.
Carbona Stain Devils
Переглядів 518Рік тому
Carbona Stain Devils for Motor Oil, Tar, and Lubricants. I used this product on a jacket and two sweatshirts with oil stains. I would say the product faded the stains but did not remove them. You can see the results in the video.
New York Botanical Garden Train Show 2023
Переглядів 617Рік тому
The New York Botanical Garden Train Show 2023. The trains are displayed in a holiday theme among flowers and historical NYC buildings made of things from the garden ( bark, leafs, acorns, etc...).
How to put wood trim around a door | tips and tricks for wood trim
Переглядів 98Рік тому
I put wood trim around a bathroom door. I show some tricks I learned over the years of doing this.
Stuck Caliper Slide Pin
Переглядів 115Рік тому
Had to hammer out a slide pin, fix the caliper bracket, and replace the boot and pin.
Navi River | Disney's Na'vi River Journey
Переглядів 23Рік тому
Disney Na'vi River Ride. The ride starts out kind of dark but gets better toward the end.
Wild Willies Airboat Tours | Air Boat | Orlando airboat ride
Переглядів 101Рік тому
A thrilling ride aboard Wild Willy's airboat tour. A view of Florida most people would never see. See wildlife in it's natural habitat. You might not always see a gator, but you will see something and have a fun ride doing it.
Disney's Animal Kingdom Kilimanjaro Safaris | Disney Safari ride
Переглядів 362Рік тому
Disney's Animal Kingdom Kilimanjaro Safaris | Disney Safari ride
Mad Beaver
Переглядів 21Рік тому
Mad Beaver
Aquastat Repair
Переглядів 14 тис.Рік тому
Aquastat Repair

КОМЕНТАРІ

  • @chephoenix2551
    @chephoenix2551 3 дні тому

    I found this video incredibly helpful!

    • @budget105
      @budget105 3 дні тому

      I am glad it was helpful!

  • @MehmedHasan-q1p
    @MehmedHasan-q1p 8 днів тому

    Thanks, I have the same issue. I will try it before calling a technician.

  • @rexcoleman4974
    @rexcoleman4974 23 дні тому

    Excellent explanation and video of the repair. I will give this a shot before calling a technician. Thanks for the demo.

  • @tristanandsb2592
    @tristanandsb2592 Місяць тому

    I think someone called it "jelly"

  • @nickpanhead7209
    @nickpanhead7209 Місяць тому

    Hi came across your video, I can turn my thermostat up to a higher room temp. Circulator pump kicks on, but boiler don't turn on. Would you happen to know why, or could this be my issue what you just did

    • @budget105
      @budget105 Місяць тому

      @nickpanhead7209 If you own a voltage meter, check if there is power going to the burner. If the circulator is running and there's no power on the burner lines, then the problem is in the aquastat. If there is power going to the burner and it's not running, the burner motor may need to be replaced.

    • @nickpanhead7209
      @nickpanhead7209 Місяць тому

      I appreciate you getting back to me. I have 2 zones, one zone works correctly and the other 1. Just the circulator pump turns on, one of the thermostats is wired to the aquistat the other is wired to a relay box. The thermostat wires that are going to the aquastat. I am going to remove and ring out wires to the thermostat. Just to make sure i'm dealing with the correct set of wires that I'm having an issue with what terminals go to the oil burner itself in the aquastat. The first zone I have no problem. I turned the heat on and the boiler Kix in the one. I'm having an issue with just the circulator pump turns on no boiler. I feel it is the aquestat like you're saying is that something that could be fixed with soldering, if it is. Thank you for your help. Hopefully, you can get back to me. Once again?

  • @tonymanero5544
    @tonymanero5544 Місяць тому

    Great video. I’ll add a few comments. Your Tridicator was replaced, but with a long instead of short stem so it’s sticking out. But it’s allowing access to the mounting screw on the aquastat. A triple aquastat like your Honeywell cost about $160, but if solder joints are getting blow out, I would replace the whole thing with a electronic one like the Aquastat 3200 for Gas (3250 for Oil) which has temperature and status lights indicating boiler activity. By looking at the 3200 indicators, I can see the water temperature, if there is a heat call, and with the Economy function, it will try to adjust temperatures down in warm days and not just turn the boiler on/off like your electro-mechanical unit. Also, it seems my old Honeywell wasn’t heating water to the 180 setting I selected, but a lower temperature which I discovered after installing the electronic asquastat.

    • @budget105
      @budget105 Місяць тому

      @tonymanero5544 Thanks for your response. I have a spare aquastat and have done the same repair on both. They last about 7 years after the fix. I will have to check out the 3250.

  • @dustpan2000
    @dustpan2000 2 місяці тому

    I'm trying this before I call the tech. Thanks!

    • @budget105
      @budget105 2 місяці тому

      @@dustpan2000 I hope you can fix it.

  • @c.morgan5590
    @c.morgan5590 2 місяці тому

    I'm getting ready to install these...thanks for the information.

    • @budget105
      @budget105 2 місяці тому

      @c.morgan5590 they keep the leaves out, but you will have to clean the gutters out every three years or so.

  • @help797
    @help797 2 місяці тому

    Learned a lot, excellent presenation! Thank You

  • @dr.funyunjlordsmg4865
    @dr.funyunjlordsmg4865 3 місяці тому

    Fluid Film is more of a wax than an oil. I haven’t tested any of the carbona products, but they say the nail polish remover version works on wax.

  • @kman1644
    @kman1644 5 місяців тому

    Where is the end switch on the kazeffi? I don't see it on mine.

    • @budget105
      @budget105 5 місяців тому

      The switch was on the bottom of mine. It was an exact copy of the Honeywell.

  • @paulo1149
    @paulo1149 7 місяців тому

    Fantastic job. So clear. Thanks.

  • @MalachiReds
    @MalachiReds 7 місяців тому

    Would you please pass the jelly?

  • @magada3135
    @magada3135 7 місяців тому

    Just as your video showed. Where did the solder go? For me, it wasn't the circulator, it was the oil burner. But thank you Brian, we have heat again. Yay!

  • @SuperJohn0927
    @SuperJohn0927 9 місяців тому

    Look like plumber putty 😅

  • @firstnationsindian8062
    @firstnationsindian8062 10 місяців тому

    Hey Dad!! No more coffee for you. Thanks for the education.

  • @billverine765
    @billverine765 10 місяців тому

    Thank you sir. I am having same problem where pump won't run, but boiler is heating. The relay is moving but is making a buzzing sound. I am going to replace or repair this myself after watching this, I thought there was water under pressure where the thermostat slides into the pipe.

  • @boilerheroes
    @boilerheroes 10 місяців тому

    Good job

  • @boilerheroes
    @boilerheroes 10 місяців тому

    Clean out the fingers??

    • @budget105
      @budget105 10 місяців тому

      Yes. They are under the top cover. Extra caution should be observed when brushing the ones in the rear of the boiler. If one pushes the brush too far down the fire box insulation will be damaged.

    • @boilerheroes
      @boilerheroes 10 місяців тому

      @@budget105 cool name for them… fingers

  • @michaelnessen3605
    @michaelnessen3605 10 місяців тому

    Also, in another version of this Aquastat, there is a 6 pin connector for damper control. The solder joints on this connector also frequently go bad and can be repaired.

    • @budget105
      @budget105 10 місяців тому

      Good to know, Thanks for commenting.

    • @chephoenix2551
      @chephoenix2551 3 дні тому

      I think that’s the problem I’m dealing with. How do I repair that? Do you have a video?

    • @michaelnessen3605
      @michaelnessen3605 2 дні тому

      @@chephoenix2551 Unfortunately no. Basically, you need to carefully disassemble the Aquastat to get to the rear side of the circuit board. Then using a soldering iron, carefully reflow the solder joints with some electronic solder (with flux in the solder)....assuming you have a soldering iron.

    • @michaelnessen3605
      @michaelnessen3605 2 дні тому

      @@chephoenix2551 Unfortunately, no. You basically have to carefully disassemble the Aquastat to get to the rear side of the circuit board for the soldered pads of the connector. Use electronic solder with flux built in and reflow the pins.....assuming you have a soldering iron or gun.

  • @RobertIacobello
    @RobertIacobello 11 місяців тому

    Excellent. I had the same problem with the circulator working intermittently. I followed your clip and had ONE solder that simply disappeared. I resoldered it and now works beautiful! Honeywell needs to do better quality control in their manufacturing factories! Thank you very much!👍

    • @budget105
      @budget105 11 місяців тому

      Great 👍. I'm glad I could help.

  • @stephenaustin-g6j
    @stephenaustin-g6j 11 місяців тому

    Also having trouble with my Aquastat and will work thru this fix if it is the problem (Intermittent firing.) NOTE: I also had this problem with the kitchen stove. It originates from what I understand from the manufacture of the board. The solder joints are "cold" and do not bond correctly and when the power heats up the joint because of high resistance the remaining solder just flows away from the joint. Boom! no connection. Fixed the stove 2 years ago and is still working. I guess this will be the next project. Thanks so much for the schooling, I LOVE YT providers who do this kind of stuff!

    • @budget105
      @budget105 11 місяців тому

      The brushes on the burner motor could also be going bad. Check the output of the aquastat for power with a multimeter. If there is no power, the problem is in the aquastat. If there is power the burner motor is the problem. Good luck on your repair.

  • @evelynperez7576
    @evelynperez7576 11 місяців тому

    Its chinese

  • @evelynperez7576
    @evelynperez7576 11 місяців тому

    Thats unwelded. Its fron the contactor shaping on off thats normal

  • @johncaputo3781
    @johncaputo3781 11 місяців тому

    Very good nice tip thank you

  • @imranmuet
    @imranmuet 11 місяців тому

    Best explanation.

  • @9tomato9
    @9tomato9 Рік тому

    "I'm using the same size nozzle". Do you remember what size it was? My service company insists on using a 1.00 gal nozzle, on a 3 section weil-mcclain boiler. A small house with only one floor heated. I say that's excessive. It's the maximum size listed on the information label.

  • @take3ri
    @take3ri Рік тому

    Perfect Fix! This was the exact problem! The heat is back on!

  • @pjlopez5475
    @pjlopez5475 Рік тому

    Great Job Brian , I'm sure many people run into this common problem... minor suggestion and if possible use a desolder wick to pull all old solder off board ,clean with alcohol , and when resoldering if you access to solder flux pen apply 1st and you'll end up with factory type strong solder. In a pintch I'd do exactly as you did, once more GREAT JOB BRIAN !! my 2 cents : Mass.🛠 plumber

  • @paulyanega2373
    @paulyanega2373 Рік тому

    you also need to replace the thermal blanket that should be protecting the combustion chamber floor

    • @budget105
      @budget105 Рік тому

      The Boiler is a Slant/Finn I installed it new and it never had a blinket on the floor of the fire box. It is cast iron and full of water. Like a donut around the fire box. It was inspected and approved by a town approved service company prior to being put into service. I do like your idea of shielding the supply line. Thanks for suggesting it.

    • @paulyanega2373
      @paulyanega2373 Рік тому

      hey brother, the idea for having the insulating mat in the combustion chamber is to protect the cast iron from cracking due to possibly cold water hitting it from the return piping entering the boiler rite at the edge of the fire box when it first starts a cycle. the chamber will be red hot after just seconds of the burner running. just a little protection from the shock of the return water. all in all nice video

  • @paulyanega2373
    @paulyanega2373 Рік тому

    hey brother, you need to insulate your oil line.!! you can see its reacting to being in contact with the concrete floor. copper cant touch concrete. your homeowners insurance might not cover you when that line rots and dumps your oil tank on the basement floor. they usually require a protected oil line, which is nothing but a copper line encased in plastic.

  • @edwardwhalen284
    @edwardwhalen284 Рік тому

    great video just like a pro...

  • @thanxdude7953
    @thanxdude7953 Рік тому

    What filter do u recommend for shop vac?

    • @budget105
      @budget105 Рік тому

      There is a filter bag rated for drywall dust. That is the one I would use. The soot from the boiler is very fine.

  • @thanxdude7953
    @thanxdude7953 Рік тому

    Good video. Thankyou

  • @fernandoullaguari9073
    @fernandoullaguari9073 Рік тому

    Thank you Sr

  • @MichaelConferPhoto
    @MichaelConferPhoto Рік тому

    Thank you very much. This is exactly what just happened to mine about to disassemble and solder here soon. Thank you.

    • @budget105
      @budget105 Рік тому

      You're welcome and I am glad my video helped you. Good luck with the repair.

    • @MichaelConferPhoto
      @MichaelConferPhoto Рік тому

      The soldering and contacts sanded worked for a few days. But I had to install a new aquastat. no problem one hour install turned on everything fired up except the furnace and that’s because I didn’t put the jumper on for the 24 V on the Honeywell J1009. I believe that’s the last four digits. I couldn’t of done it without you. Thank you.

  • @pupsiklove2024
    @pupsiklove2024 Рік тому

    God bless you🙏, good job fixing it

  • @joelweiss4661
    @joelweiss4661 Рік тому

    Awesome video, thank you

  • @benc342
    @benc342 Рік тому

    So I had the same problem. Thank you, you saved me from buying a new one.

    • @budget105
      @budget105 Рік тому

      I am so glad I helped you out. I had to learn the hard way. I ended up paying over $700.00 for an emergency service. Best wishes to you.

    • @menaauto
      @menaauto Рік тому

      I think I have the same issue going on. Would you know how long this fix will last? Thanks in advance for any information!

    • @budget105
      @budget105 Рік тому

      @@menaauto on my aquastat it lasted about 8 years and then I did it again and it is still good. My Boiler is about 22 years old.