  • 364 154
PPTS Duble Stopple Animation
Plante Tech - Power Offers Specialzed Pipeline Repair & Maintenance Services Eliminating the Need of Shutdown of Service.
This Video Simulates Hot Tapping With Double Position Line Stopple Using Housing To Housing Temporary Bypass.
Reach Us At
Emial : pls@plant-techgroup.com l Phone : +919740521166
Переглядів: 247 237

Відео

36" Angle Tap on 42" Flare Line in BPCL Mumbai
Переглядів 4,1 тис.9 років тому
Successfully Executed Biggest Ever Angle Tap in India (36" On 42") 19th June 2015 was a historic day in the field of Hot Tapping Services In India, as Plant-Tech successfully completed 36" Angular Hot Tapping, The biggest ever angular tapping executed in India thus far. Our esteemed Client, M/s Offshore Infrastructre Limited was awarded with LSTK contract of plant turn Around in Bharath Petrole...
12" Hot Tapping in LP Steam Line in BPCL Mumbai
Переглядів 6 тис.9 років тому
Slide Show of execution of 12" LP Steam Hot Tapping in BPCL Mumbai
24" Angle Tap On 30" Flare Line at HPCL Mumbai
Переглядів 7769 років тому
24" Angle Tap On 30" Flare Line at HPCL Mumbai
Hot Tapping & Double Double Stopple on 24" Crude Oil Line
Переглядів 93 тис.9 років тому
This Project Involved Replacement of 9.8 KM Length Of 24" Crude Oil Pipeline of SMPL-IOCL By Doing Hot Tapping & Double Double Position Line Stopple at 4 Locations.
Simulation - Hot Tapping And Double Position Line Stopple Using Temporary Bypass
Переглядів 11 тис.9 років тому
This Video simulates the Hot Tapping & Double Position Line Stopple Operation Using Temporary Housing To Housing Bypass
Various Hot Tapping Projects Undertaken By Plant Tech Power
Переглядів 2,5 тис.9 років тому
Manufacturing of 36" and 30" Line Stop Fittings Execution of 36" & 30" Double Stopple Execution of 24" Double Double Stopple And Other Hot tapping Pojects

КОМЕНТАРІ

  • @fredyruiz8854
    @fredyruiz8854 5 місяців тому

    Impresive work....

  • @josephastier7421
    @josephastier7421 6 місяців тому

    Some magical processes here

  • @ghezalabdelhamid7788
    @ghezalabdelhamid7788 Рік тому

    Thank you for this information, could i know what is the programme that you use for simulation

  • @davidboyman2633
    @davidboyman2633 Рік тому

    where does the pressure go when putting on blinds?

    • @mickraff66
      @mickraff66 Рік тому

      I cannot work that bit out ?

  • @martkyfristkysalomosenduk9983

    Sir, may i ask you a question, is it mandatory to install the ballon plug?

  • @pauledwards1157
    @pauledwards1157 2 роки тому

    Too many errors in this video.

  • @anuragkumar7740
    @anuragkumar7740 2 роки тому

    Nice informative video covering all concerned points.

  • @YasirAli-wz8kd
    @YasirAli-wz8kd 2 роки тому

    Tag bcj

  • @yancenazifah8151
    @yancenazifah8151 3 роки тому

    Nice stopple equipment.

  • @danielmoreno8493
    @danielmoreno8493 3 роки тому

    I dont understand. I thought double doubles would have had 4 taps and bypass goes behind the stop but I may be confused

  • @yrun989
    @yrun989 3 роки тому

    [Welder life]ofical cut[SV] Pipe line test √ Just meter

  • @irishcarascon8158
    @irishcarascon8158 3 роки тому

    hi what is your email address?

  • @navgunner80
    @navgunner80 4 роки тому

    this looks like a yellow version of TD Williamson equipment. Was this just a repaint of their equipment?

  • @davidhopkins7215
    @davidhopkins7215 4 роки тому

    What is considered Low Pressure?

  • @anarismayilli5499
    @anarismayilli5499 4 роки тому

    ua-cam.com/video/EVKuW67K4KQ/v-deo.html

  • @bijiyantsinghsingh4359
    @bijiyantsinghsingh4359 4 роки тому

    Nice job

  • @user-pm2pp4fo8g
    @user-pm2pp4fo8g 4 роки тому

    لو سمحت ممكن طريقة هذي أمته تمه اكتشافه وتاريخ في فيدو

  • @MegaRIFIANO
    @MegaRIFIANO 5 років тому

    technician without gloves, technician on line of fire, technician climbing on the valve, scaffold not tagged, etc.... etc...this company is not the safest...a mix of pictures of different job with different type of machines....Hope the camera was ATEX

    • @jonathanmanley8739
      @jonathanmanley8739 5 років тому

      MegaRIFIANO cold cut guy is in there with no FR and short sleevesAND a polyester golf shirt......definitely not real pipeliners

  • @boddetiramakrishna6489
    @boddetiramakrishna6489 5 років тому

    Hot Tapping & Double Double Stopple on 24" Crude Oil Line

  • @user-ku2nh1ci2c
    @user-ku2nh1ci2c 5 років тому

    Для специалистов из РФ, на все вопросы по трубопроводной арматуре (pipeline accessories) ответят наши инженеры: saratovsnab.ru/

  • @karlwooduk
    @karlwooduk 6 років тому

    awesome.

  • @anhtuantran9194
    @anhtuantran9194 6 років тому

    hi guys. we provide some products like this. we have many sizes of pipe line repairs. just contact us via justin@nuoen.vn

  • @adanperez6524
    @adanperez6524 7 років тому

    every liquid has a boiling point for it to ignite. if it is to rich doesn't ignite.another scenario is that need to be present the right elements like fuel,oxygen and fire.

  • @magip355
    @magip355 7 років тому

    How is it that the product doesn ignite as s result of the heat of the first drilling point (to install the spool fir the bypass line)

  • @TheGauravgothwal
    @TheGauravgothwal 7 років тому

    was it a process line . or utility line ?