CJ's HVAC JOURNEY
CJ's HVAC JOURNEY
  • 41
  • 39 417

Відео

Hvac repairs on a Trane CGAM Chiller
Переглядів 18914 днів тому
Hvac repairs on a Trane CGAM Chiller
HVAC Troubleshooting Superheat issues
Переглядів 2022 місяці тому
HVAC Troubleshooting Superheat issues
HVAC- I MADE A HUGE MISTAKE!!!!
Переглядів 1,2 тис.2 місяці тому
While doing a running inspection I accidentally blew the schrader from the discharge port into the condenser coil of a CGAM Chiller! But with the help of God I was able to get it back up and running!
Hvac Liebert R22 Compressor Internal overload
Переглядів 1143 місяці тому
I attempted to save the compressor but it had to be replaced and is now operating.
HVAC troubleshooting an electrical issue on a VAV box.
Переглядів 3613 місяці тому
Issue was I wasn't getting 277 volts to power up the control side. Found a issue with the neutral wire while troubleshooting. Informed electrician and I believe they found the neutral wire to be loose in one of the electrical boxes.
Hvac Service Call troubleshooting refrigerant circuits Trane DOAS unit
Переглядів 2,5 тис.3 місяці тому
Me troubleshooting a KCC unit for multiple alarms on a service call.
Hvac Refrigerant recovery tip you probably never thought about!
Переглядів 2,7 тис.4 місяці тому
Here's a tip I learned recently that will lower your tank pressure to decrease recovery time. Works better with ice and water, but water alone will work some as well.
HVAC VFD compressor fault!
Переглядів 9984 місяці тому
Me troubleshooting a VSD compressor fault on a Trane Voyager.
HVAC Is The Compressor Bad?
Переглядів 1,8 тис.4 місяці тому
Me on a no cooling call in which I found the condenser fan motor running but the compressor not! I almost misdiagnosed!The system is low on refrigerant as well.
HVAC Trane Voyager Tandem Compressor replacement refrigerant recovery.
Переглядів 1,4 тис.4 місяці тому
1st tandem compressor replacement as the lead technician on a Trane symbio voyager 3!
HVAC TRANE KCC HORIZON DOAS STARTUP DAY!
Переглядів 2264 місяці тому
Startup of a KCC DOAS Unit!
Hvac Failed TXV
Переглядів 564 місяці тому
Hvac Failed TXV
Klein ET600 megger
Переглядів 3,3 тис.11 місяців тому
Klein ET600 megger
HVAC Flame Sensor: How does it work?
Переглядів 41311 місяців тому
HVAC Flame Sensor: How does it work?
Removing blower bearing Carrier rooftop unit!
Переглядів 938Рік тому
Removing blower bearing Carrier rooftop unit!
Trane CSAA Airhandler Belt tension procedures.
Переглядів 184Рік тому
Trane CSAA Airhandler Belt tension procedures.
Hvac Service Call Troubleshooting
Переглядів 972 роки тому
Hvac Service Call Troubleshooting
RTAA Trane Chiller
Переглядів 6752 роки тому
RTAA Trane Chiller
Blower motor sheave adjustment Trane airhandler
Переглядів 2332 роки тому
Blower motor sheave adjustment Trane airhandler
HVAC grounded compressor
Переглядів 312 роки тому
HVAC grounded compressor
Hvac how to check a low pressure switch
Переглядів 4,6 тис.2 роки тому
Hvac how to check a low pressure switch
Hvac adjusting belt on Trane Voyager
Переглядів 6522 роки тому
Hvac adjusting belt on Trane Voyager
Hvac filter change air Handler
Переглядів 565 років тому
Hvac filter change air Handler

КОМЕНТАРІ

  • @baylifehvac991
    @baylifehvac991 3 дні тому

    That’s dope Blessing bro !

  • @michaeldarrow6021
    @michaeldarrow6021 4 дні тому

    Don't talk much do ya?

  • @EverythingHVACR
    @EverythingHVACR 6 днів тому

    Nice job Tech! Great tip.

  • @AngusLowrieSkates
    @AngusLowrieSkates 8 днів тому

    Double the voltage, IR Testers use DC voltage

  • @MrApplied
    @MrApplied 13 днів тому

    How did the job come out?

  • @MrApplied
    @MrApplied 16 днів тому

    Awesome content man are you oem Trane service?

  • @EverythingHVACR
    @EverythingHVACR 16 днів тому

    I do love those intellipacks. Blue hoses are a game changer, right? Keep up the good work! 💪

  • @EverythingHVACR
    @EverythingHVACR 16 днів тому

    Nice looking unit there. Great advice! Leave the Trade better than you found it. Keep that content coming.

  • @ZRock7771
    @ZRock7771 19 днів тому

    Out with the old, in with the new. Nice work.

  • @jaredcritzer2647
    @jaredcritzer2647 25 днів тому

    Great tip boss

  • @LC-qi5ff
    @LC-qi5ff Місяць тому

    Not a bad tip!

  • @MarioFelipeGuzman-n2y
    @MarioFelipeGuzman-n2y Місяць тому

    Precio

  • @deavonsanchez3084
    @deavonsanchez3084 Місяць тому

    Restriction

    • @cjshvacjourney4034
      @cjshvacjourney4034 Місяць тому

      @deavonsanchez3084 yep one of the txvs failed shut. Bulb lost its charge.

    • @deavonsanchez3084
      @deavonsanchez3084 Місяць тому

      @cjshvacjourney4034 how many years you got, and wya

    • @cjshvacjourney4034
      @cjshvacjourney4034 Місяць тому

      @@deavonsanchez3084 I have about 5 1/2 years in the field

  • @kcomfortsystemshvac7060
    @kcomfortsystemshvac7060 2 місяці тому

    Hi mate ,,,,did you change ,,vfd drive ?

  • @larryhatfield7372
    @larryhatfield7372 2 місяці тому

    That's something that would happen to me

  • @robertlowrey42
    @robertlowrey42 2 місяці тому

    Learning more about trane watching your videos, keep them coming man.

  • @Menik559
    @Menik559 2 місяці тому

    Bad valves?

  • @xraybravo7180
    @xraybravo7180 2 місяці тому

    Have you done a comparison test on it with fluke or other brand on a failed compressor? I know you got them. How to use it a select correct mega ohms for testing motirs and compressors ? Is it bellow 30 mega ohms bad on 4000 mega ohm setting ? Give me your knowledge.

  • @xraybravo7180
    @xraybravo7180 2 місяці тому

    Can you explain how much knowledge you got on how much The resistance should be ? If you were to use a regular ohm function on a regular meter what would shoe on thus compressor?

    • @cjshvacjourney4034
      @cjshvacjourney4034 2 місяці тому

      @xraybravo7180 Honestly I'm no expert especially on meggers but I think you should be able to see at least 40 Mega ohms to ground with a good meter such as a fluke to determine a problem. I pretty much pull out the megger to see if it is taking the voltage I apply to it for a motor or Compressor. I could be wrong but the ones I have tested were not taking the voltages I applied to them were failed because I try to always make a comparison.

  • @davidturney2975
    @davidturney2975 2 місяці тому

    That's a new one

  • @NewDestinationEng
    @NewDestinationEng 2 місяці тому

    Time for some flex tape 😂 Now seriously... THE SCHRADER CORE DID THAT?!

    • @cjshvacjourney4034
      @cjshvacjourney4034 2 місяці тому

      Yep that Schrader shot out like a bullet I meant to take a picture.

    • @NewDestinationEng
      @NewDestinationEng 2 місяці тому

      @@cjshvacjourney4034 wow that's insane

  • @arthouston7361
    @arthouston7361 2 місяці тому

    Yes. Because it didn't go into your eye, praise God. This is one thing that you will make sure you don't repeat. Some of my best lessons happened on a roof.

    • @cjshvacjourney4034
      @cjshvacjourney4034 2 місяці тому

      Amen that would have definitely put a hole in my eye! Thank God it didn't!

  • @luiscarbo3767
    @luiscarbo3767 2 місяці тому

    I wonder if you can isolate that section of the coils?

    • @cjshvacjourney4034
      @cjshvacjourney4034 2 місяці тому

      You cannot once that hole is in it you have to repair if you can if not replace the coil.

  • @nickyborrisino
    @nickyborrisino 2 місяці тому

    At 1:13 are those gauges showing a bad compressor? (Even pressure at both high and low sides)…..

    • @cjshvacjourney4034
      @cjshvacjourney4034 2 місяці тому

      Nope it's under nitrogen for the pressure test before the vacuum.

  • @jacobhendrickson8935
    @jacobhendrickson8935 2 місяці тому

    I’m trying to understand what happened?? Is that a hole in the coils or is there a valve there? And if so what happened?

    • @ranger178
      @ranger178 2 місяці тому

      the schrader valve down below the coil shot up into coil and put hole in coil he had to braze shut.

    • @jacobhendrickson8935
      @jacobhendrickson8935 2 місяці тому

      @@ranger178 wow that would suck. Did it do this while you was messing with the valve or something?

    • @cjshvacjourney4034
      @cjshvacjourney4034 2 місяці тому

      ​@@jacobhendrickson8935I was trying to replace a leaking discharge line Schrader on a preventative maintenance and had trouble removing it because my tool didn't seem to want to grab it so I removed the part that grabs the Schrader and valved it off. Put a rag on top of the tool while slightly purging and I thought I had the Schrader break free and I removed the rag and opened it little by little and saw on liquid coming out and thought I was good and turns out the Schrader was still in and blew into the coil.

    • @yinggamer7762
      @yinggamer7762 2 місяці тому

      @@cjshvacjourney4034would attaching another core tool to the core tool and keeping the second closed be a safer way?

    • @cjshvacjourney4034
      @cjshvacjourney4034 Місяць тому

      ​@yinggamer7762 Yes that would definitely be safer i didn't think of that.

  • @mineown1861
    @mineown1861 2 місяці тому

    Better lodged in the condenser than you , better the system bleeding gas than you bleeding. Cold comfort I know but ... and that's my hvac pun for the day .

  • @justrcfun1042
    @justrcfun1042 2 місяці тому

    I don’t work on big units like that much but is there anyway to close off valve to compressor and save some refrigerant if that does happen? Or not even worth it ?

    • @cjshvacjourney4034
      @cjshvacjourney4034 2 місяці тому

      Nope once that coil blows it's over you can start recovering refrigerant like I did to prevent it from venting into the atmosphere. I got about 37lbs out but I just put virgin refrigerant back in

    • @justrcfun1042
      @justrcfun1042 2 місяці тому

      Ahhhh ok, that sucks man sorry that happened to you but at least you got it going again. Good luck and keep on posting!

  • @Paul-IE-Repairs
    @Paul-IE-Repairs 2 місяці тому

    thats a pricey oops!

  • @dmvhvactech
    @dmvhvactech 2 місяці тому

    Damn son thats wild, did it get stuck in the appion vcr while changing it out?

    • @cjshvacjourney4034
      @cjshvacjourney4034 2 місяці тому

      It wouldn't come out with the tool so I valved it off with a rag on top and cracked it. Thought I heard the schrader blow off so I valved it off removed the rag began cracking it and only saw liquid coming out and opened it a little more and it shot out like a bullet.

    • @ve4edj
      @ve4edj 2 місяці тому

      Damn punctured the condenser above it. Literally a bullet.

  • @diegopa9980
    @diegopa9980 2 місяці тому

    Can you describe in what order you did this job?

    • @cjshvacjourney4034
      @cjshvacjourney4034 16 днів тому

      @@diegopa9980 1. Refrigerant recovery 2. Un-braze old compressor/ liquid line filter drier. 3. Install new liquid line filter drier/ compressor. 4. Pressure test for leaks. 5. Pull deep vacuum and verify it holds. 6. Charge system with refrigerant and verify proper operation. There are much more things involved but this is the basics

  • @DavidBarry-oq7nn
    @DavidBarry-oq7nn 3 місяці тому

    Double the voltage on a Megger

  • @PhilJackZen
    @PhilJackZen 3 місяці тому

    You didnt hold the test button long enough. You can see it only sent 14v through. Also you have the wrong voltage selected

  • @robertlowrey42
    @robertlowrey42 3 місяці тому

    Like your videos, want to learn more about trane, keep them coming.

  • @robertlowrey42
    @robertlowrey42 3 місяці тому

    I might get one of these

  • @robertlowrey42
    @robertlowrey42 3 місяці тому

    I think you nailed. Nice job.

  • @robertlowrey42
    @robertlowrey42 3 місяці тому

    What wound up being the issue?

    • @cjshvacjourney4034
      @cjshvacjourney4034 3 місяці тому

      The neutral wire was loose inside one of the electrical boxes.

  • @robertlowrey42
    @robertlowrey42 3 місяці тому

    Liking your channel. Keep the videos coming.

  • @lynnprince6635
    @lynnprince6635 3 місяці тому

    Can't hear a word you said 😮😮

  • @Hvacnc
    @Hvacnc 3 місяці тому

    This megger better than the supco one?

    • @cjshvacjourney4034
      @cjshvacjourney4034 3 місяці тому

      @@Hvacnc I've never used the supco personally but this one has multiple functions and has treated me well. My coworker purchased this one when his supco failed and he seems to like it as well.

  • @dirkdigler9336
    @dirkdigler9336 3 місяці тому

    Trane DOAS unit?

  • @missionuluna5837
    @missionuluna5837 3 місяці тому

  • @JackGore
    @JackGore 3 місяці тому

    Good job

  • @danielogwuche769
    @danielogwuche769 3 місяці тому

    Well done tech , which software are you using for troubleshooting

  • @Swxnflu
    @Swxnflu 3 місяці тому

    hey man what service area are you in.

  • @liamaaronduran
    @liamaaronduran 4 місяці тому

    Your not even using it right you either have to hold it down or put it in test lock mode both of which you are not doing, your not megging this compressor at all.

    • @cjshvacjourney4034
      @cjshvacjourney4034 4 місяці тому

      @liamaaronduran Look close at the megger I already had pressed the test lock button 👍

  • @maheradous9257
    @maheradous9257 4 місяці тому

    Good job 👍

  • @davidperkins7916
    @davidperkins7916 4 місяці тому

    Thorough! Nice! Wish my techs would follow suit! Hard to find good technicians.

  • @mundoracer
    @mundoracer 4 місяці тому

    The shaking is creating more thermal heat transfer into the ice water. Also, best to have icy water, not just ice

  • @NikolaStamenkovic6
    @NikolaStamenkovic6 4 місяці тому

    Makes sense, fuller it gets more energy is needes to compress and creates more heat in the process. Shaking it liquid starts moving and cooling faster. But this should always be plan B, plan A should be having emptier tank in my opinion. Not an expert just observing.

  • @jungapo2
    @jungapo2 4 місяці тому

    why not create a jig using small car radiator or old used evaporator with fan to cool the refrigerant instead of using ice.

    • @cjshvacjourney4034
      @cjshvacjourney4034 4 місяці тому

      @jungapo2 lot of work I never really thought that far because ice seems to work great but no telling what I'll try in the future.

    • @horacegardner3516
      @horacegardner3516 3 місяці тому

      That is essentially what the this recovery pump does, hence the fan in the recovery machine. However in hot environments (summer in the south) this pumps internal fan can’t overcome the heat load. Therefore the recovered refrigerant gets hot and causes the pump to shut down due to the extremely high pressure. 134 degree temp of r410=500 psi. Using the ice bath is necessary to complete recovery.