HVAC Tool Porn!
HVAC Tool Porn!
  • 352
  • 247 890

Відео

Had to use a tow truck to lift a condenser on the roof.
Переглядів 215День тому
It was July 5th, and the boss didn't realize the unit was on the roof. Called 5 crane companies with no luck. Called up the recovery tow truck and got it done...
I saved an old r22 system using 427a.
Переглядів 1,9 тис.21 день тому
The capacitor was swelled and needed replaced. let the system run to find it was low on r22. 427a was able to keep this system going. No need to replace it just yet...
Found 2 nice klien screwdrivers in this trane rtu.
Переглядів 27521 день тому
Nothing beets free tools!
Installing a gree 3 ton mini split system from scratch.
Переглядів 23321 день тому
Easy install, mount head drill holes, and mount condenser. Attach the lines and power and get that area cool!
Walk in cooler service call, rushed as I had install scheduled.
Переглядів 38828 днів тому
Got it up and going, but not how I would typically have done it... would have preferred to put a new breaker and wire to the evap. Job is being quoted for replacement, so I will more than likely end up doing it then.
Installing a new trane roof top unit!
Переглядів 11328 днів тому
I almost left my old faithful flat head behind... simple like for like install. It was easy money!
York coated condenser leak. Fixed the 410a leak.
Переглядів 1 тис.Місяць тому
York coated condenser leak. Fixed the 410a leak.
Dainkin rtu develops a refrigerant leak after repair.
Переглядів 147Місяць тому
Dainkin rtu develops a refrigerant leak after repair.
walk in freezer is to warm service call, drain clauged and excessive defrost time.
Переглядів 242Місяць тому
walk in freezer is to warm service call, drain clauged and excessive defrost time.
I found a refrigerant leak coming out of the electrical wires on a carrier rooftop unit.
Переглядів 418Місяць тому
I found a refrigerant leak coming out of the electrical wires on a carrier rooftop unit.
Hoshizaki km-515 not producing ice. Simple service call with a bad part.
Переглядів 97Місяць тому
Hoshizaki km-515 not producing ice. Simple service call with a bad part.
Compressor changed out on a Trane in 100+degree temps.
Переглядів 369Місяць тому
Compressor changed out on a Trane in 100 degree temps.
Using $100 Amazon winch to lower the compressor off the roof!
Переглядів 1,5 тис.Місяць тому
Using $100 Amazon winch to lower the compressor off the roof!
What a Trane speed port looks like and how it works.
Переглядів 187Місяць тому
What a Trane speed port looks like and how it works.
Dirty, horny, short on gas and not enough air flow. Friday night service call.
Переглядів 142Місяць тому
Dirty, horny, short on gas and not enough air flow. Friday night service call.
Walk in cooler iced up. Setpoint was to low.
Переглядів 18Місяць тому
Walk in cooler iced up. Setpoint was to low.
Start components damaged by suction line condensation drip. Reach in cooler hvacr service call.
Переглядів 22Місяць тому
Start components damaged by suction line condensation drip. Reach in cooler hvacr service call.
walk in cooler temp fix until new unit can be installed. Smell of death.
Переглядів 18Місяць тому
walk in cooler temp fix until new unit can be installed. Smell of death.
Daytona Beach draw bridge.
Переглядів 65Місяць тому
Daytona Beach draw bridge.
Beacon 2 controls quick know how and pairing and syncing knowledge!
Переглядів 27Місяць тому
Beacon 2 controls quick know how and pairing and syncing knowledge!
Maxwell house iced latte with foam Carmel! All you need is ice and water! yummy yummy
Переглядів 23Місяць тому
Maxwell house iced latte with foam Carmel! All you need is ice and water! yummy yummy
Nothing I can do to get this store cool!
Переглядів 13Місяць тому
Nothing I can do to get this store cool!
New compressor and dryer for this reach in freezer!
Переглядів 101Місяць тому
New compressor and dryer for this reach in freezer!
Trane symbio 700 how to disable discharge air sensor or sensors.
Переглядів 1232 місяці тому
Trane symbio 700 how to disable discharge air sensor or sensors.
Is it just me or is Trane symbio turning on the wrong compressor? simple fix on this one.
Переглядів 1,1 тис.2 місяці тому
Is it just me or is Trane symbio turning on the wrong compressor? simple fix on this one.
Pushing a 5 ton package unit off a roof!
Переглядів 8102 місяці тому
Pushing a 5 ton package unit off a roof!
Warm beer cave! Copper pipe used as a fuse to blame! Easy service call!
Переглядів 6832 місяці тому
Warm beer cave! Copper pipe used as a fuse to blame! Easy service call!
space launch may 17 2024
Переглядів 172 місяці тому
space launch may 17 2024
space launch may 2 2024
Переглядів 52 місяці тому
space launch may 2 2024

КОМЕНТАРІ

  • @thomasschwarting5108
    @thomasschwarting5108 5 днів тому

    So, no updates?!

    • @hvactoolporn188
      @hvactoolporn188 5 днів тому

      Both gas station and store are back to corporate setpoint of 74°, Now subway knows where there switch for exhaust fan is.

  • @joshuaashton9342
    @joshuaashton9342 8 днів тому

    One strap😮,? ... Hey guys welcome back to dangy bros today we'll be lifting with a singular strap😅 there good 😂

    • @hvactoolporn188
      @hvactoolporn188 8 днів тому

      We are good. Made it to the roof. No harm to people or equipment... one thing I've learned with hvacr is not every job will be picture perfect. The lifting strap was under its lifting capacity. And with the tie off, I had 3 points of contact on the equipment at all times of the lift...

  • @suezq74
    @suezq74 15 днів тому

    I’m glad that R22 is gone, R22 is 🤮🤮🤮🤮🤮

  • @hvac402
    @hvac402 15 днів тому

    Can you just move the 24 V wires from one contactor to the other

    • @hvactoolporn188
      @hvactoolporn188 15 днів тому

      No, the board will fault out. First thing I tried.

  • @mukhtarahmed7538
    @mukhtarahmed7538 19 днів тому

    What size wrench holds the security pin on the shaft?

  • @Trust_but_Verify
    @Trust_but_Verify 21 день тому

    427A ua-cam.com/video/hyZqOPLpOvc/v-deo.html

  • @Trust_but_Verify
    @Trust_but_Verify 21 день тому

    How much is 427a per lb? What's the cost of replacing R-22 with 427a for household AC?

    • @hvactoolporn188
      @hvactoolporn188 21 день тому

      We charge $60 per lb of 427a and do not stock or use r22...

  • @DallasPhillips-hz9yn
    @DallasPhillips-hz9yn 21 день тому

    You don’t charge off sub cooling or superheat?Just get the pressure half ass close and call it good

    • @hvactoolporn188
      @hvactoolporn188 21 день тому

      @@DallasPhillips-hz9yn all of the above. Subcooling 10-14 super heat 20-40 pressures 65-70/225-250

    • @suezq74
      @suezq74 15 днів тому

      You made a spelling mistake. “ass” is not correct. “as” is.

    • @DallasPhillips-hz9yn
      @DallasPhillips-hz9yn 15 днів тому

      @@suezq74 no I didn’t half ass is what I said

  • @Demoralized88
    @Demoralized88 22 дні тому

    Nice to see an honest tech and not a predatory salesman pushing new equipment at crazy prices these days. I only found out about R-22 replacements after some research and it seems the industry norm is either recharging with R-22 at crazy prices or new equipment. These drop-in R-22 replacements seem way less common than they should be when R-22 equipment is in good condition but lost charge from a repairable leak. I don't think I can buy these without an HVAC license but from what I understand 427A, 407x, and other R-22 drop-ins are like less than $50/pound versus the dwindling supply of R-22 being several hundred per pound these days.

    • @hvactoolporn188
      @hvactoolporn188 22 дні тому

      I don't carry r22 on my truck anymore. The only option with me is to convert it over. OR new equipment depending on what is wrong with it...

    • @pairofjacks1006
      @pairofjacks1006 9 днів тому

      Update...MOST techs are honest, poorly trained perhaps but they believe what they are saying... it's the owners who send them out that are ripping you off..

  • @robertbenavidez7164
    @robertbenavidez7164 23 дні тому

    Great Job, I used to do A/C on Automobiles way back when, did u need to retrofit any of the parts? To accept the new 427A freon? Or is the freon the new R22? Sorry been out of the loop for yrs now.🤭

    • @Demoralized88
      @Demoralized88 22 дні тому

      427A is designed to be a 'drop-in; R-22 replacement that has very similar pressures and requires no changes for existing R-22 systems. Basically a new production alternative to the shrinking R-22 supply and crazy prices yet I barely knew about R-22 replacements as someone not working in HVAC and was just concerned about new AC unit prices if our R-22 system developed a leak. R-22 was used in AC units until 2010 when it was replaced by 410-A in all new units, but 410-A runs at higher pressures than R-22 so they're not compatible and you need to find a certain R-22 replacement like seen here that can be used in pre-2010 AC units. This is basically the alternative to having to buy crazy overpriced new equipment if you have a repairable leak.

  • @WhowereEpsteinsclients
    @WhowereEpsteinsclients 23 дні тому

    Did you make a long video if this job. I would like to see if you ended up replacing that failing condenser motor. Also I would have liked to see if you replaced the filter drier when you removed all the r-22 and replaced with 427-a. Which you probably did none of that. 427-a is my go to r-22 replacement but Im not a hack and mix 427-a and R-22. I recommend deleting this video if there is not a long form.

    • @hvactoolporn188
      @hvactoolporn188 23 дні тому

      No long video. Dryer was inside next to airhandler and was replaced. Everybody hacks stuff a time or two, so when you say you not a hack, understand that some jobs can not be completed to perfection depending on the customer. Im not a fan of blending gas. This particular gas station has its own repair men, not sure if they don't handle r22 or why I was there, but my job was to get that unit going and did just that.

    • @DallasPhillips-hz9yn
      @DallasPhillips-hz9yn 21 день тому

      427a is a direct drop in replacement you can add it strait to R22.If you have a TXV might have a very slight temp glide will be fine.How about you post videos of your jobs since you’re so by the book show the rest of us how great you are

    • @WhowereEpsteinsclients
      @WhowereEpsteinsclients 21 день тому

      @@DallasPhillips-hz9yn Where does it say you can blend refrigerants?

    • @DallasPhillips-hz9yn
      @DallasPhillips-hz9yn 21 день тому

      @@WhowereEpsteinsclients direct drop in what part of that don’t you understand?what do you think for example R407c is a blended refrigerant. It takes like three refrigerant to make 407C.

    • @DallasPhillips-hz9yn
      @DallasPhillips-hz9yn 21 день тому

      @@WhowereEpsteinsclients what part of direct drop in don’t you understand.407c is a blended refrigerant for example.takes like 3 refrigerants to make R407.It runs the same type of oil made as a direct drop in boiling points arnt far apart anuff to matter

  • @dummyvr9802
    @dummyvr9802 23 дні тому

    i heavily fuck with the name

  • @somnuswaltz5586
    @somnuswaltz5586 24 дні тому

    Is that forrest gump or is he just drunk?

  • @lccerrillo
    @lccerrillo 26 днів тому

    Just investigate one with that proving lockout alarm with tandem circuit, it was overcharged

  • @user-ji4oq6qq2g
    @user-ji4oq6qq2g 29 днів тому

    Tree frogs

  • @user-yp3qg3km7s
    @user-yp3qg3km7s Місяць тому

    Sad ain't it, we close to our tools. I have owned a few that I have actually named

  • @kubam9883
    @kubam9883 Місяць тому

    Oragne juice ? 😂

  • @user-wn8mg2jh1d
    @user-wn8mg2jh1d Місяць тому

    Work on your editing and easy on the camera movement

  • @silentscribes
    @silentscribes Місяць тому

    Or...by hand.

    • @iangregoryhome
      @iangregoryhome Місяць тому

      It would of been quicker 😂

    • @Straight_White_Fatherly_Figure
      @Straight_White_Fatherly_Figure Місяць тому

      Itd be nice if they made a vest that you can strap a compressor to so all you need to do is use your legs and 1 arm

  • @WswRefrigeration
    @WswRefrigeration Місяць тому

    Even with the set point too low with 2 probe dixell with defrost set up its shouldn’t ice up like that . I always go into the advanced settings and check what temps the probes are reading and make sure that’s correct. Also ohm out the sensors etc but ya definitely too low of a set point

  • @norsevikingsir4932
    @norsevikingsir4932 Місяць тому

    Don’t use that stuff, they’ve come a long way with way better stuff. And you have no mask on, your life has been shortened tremendously

  • @j26a24d
    @j26a24d Місяць тому

    Gracias por tu aportes 👍

  • @scottsnider3511
    @scottsnider3511 Місяць тому

    I have the same issue on a 7.5ton proving switch 1st stage issue, and tech supports no help. I replaced the contactor and aux without resolution. Did you find a solution?

    • @hvactoolporn188
      @hvactoolporn188 Місяць тому

      We replaced contactor and micro switch and 2 days later ordered a Dainkin unit. We are experimenting with gutting controller on a few units but have not made a final decision to what methods we will use in the future....

    • @Kdavis8377
      @Kdavis8377 26 днів тому

      Bottom contractor is actually circuit #1. Schematic is labeled wrong. Small compressor is 1st stage. Don’t ask me how I know. Had this exact issue and scratched my head for awhile. Check incoming voltage. Trane taps all their transformers for 240v. Had to tap the transformers for 208v. Haven’t had a single trip since. My control voltage went from 23.2v to 27v. Tranes are super sensitive to anything below 24v

    • @hvactoolporn188
      @hvactoolporn188 26 днів тому

      Yeah we replaced the switch and have not been back..

    • @kylewhite291
      @kylewhite291 13 днів тому

      Anybody having issues with these units not dehumidifying in 1st stage cooling? 33% cooling capacity and 66% fan speed. 50+ degree saturated suction temperature not below RAT dew point. I’ve lowered the “max fan speed” as a temporary fix but then when unit runs 100% cooling capacity it like 230cfm/ton.

  • @jamesmartin9740
    @jamesmartin9740 Місяць тому

    That start capacitor is only for the compressor bypass of a open or struggling start winding in the compressor. That blue wire shouldnt be there to the relay and is causing the burn up. This may be a return call? Over my years of service, I've never powered a start assist capacitor to a relay? They always go to the run capacitor common and herm slots. Two wire hook up only for assisting the compressor. Start up booster. So idk what that previous outfit did? The over amping on the components could be caused from the wrong power source coming in? Drawing to many amps struggling to run things. Causing over heating on relays and burning leads off components. Those relays have a normally open normally closed until powered to open bi metal strips. I cant see drawing from a start capacitor to control relay switching? Idk man, seems wrong? Also, just in observance, I believe that start cap may be over sized for that small of a system? They rate from 1-3 ton, or 3-5 ton. Definately a 3-5 ton rated start capacitor just by the size of the cylinder. Throwing way to many amps at the compressor of that size on start up. I went to RSI the refrigeration school in phx. Pretty famous industry wide school. Wish I could see the schematic or legend to help trace out what is ran to that relay for switching power instead of a start cap? That blue wire was in the wrong spot. Something else goes there to power that relay. Maybe off a contactor common?

    • @hvactoolporn188
      @hvactoolporn188 Місяць тому

      So when I fixed it I ran like you said. To the 2 poles of a 2 pole run cap and did away with the blue wire! Common wire strait to com on compressor red hot leg to cap and to run, and then from start cap to 2nd pole on 2 pole cap and to start.. fixed it rite up.

    • @jamesmartin9740
      @jamesmartin9740 Місяць тому

      @@hvactoolporn188 yes you saw it my friend! They wired it funny. Right on, yeah looking at it I was like wait a minute?

  • @jamesmartin9740
    @jamesmartin9740 Місяць тому

    😂oh this is a refrigeration unit. Not a ac unit. Still seems wired wrong? Differential timer like a ranco e15 on this thing?

    • @hvactoolporn188
      @hvactoolporn188 Місяць тому

      Yes temp controller. 28 off 38 on. Not sure what the model is in this case I have only worked on a handful of them. I went over the wiring and even stepped back and went over a second time. Could not find it.. improvised with the hard start when I realized the run cap was only rated for 220v and was 240. The customer has their own repair guys so no clue what they did to it prior...

    • @jamesmartin9740
      @jamesmartin9740 Місяць тому

      I'm a old tech from Arizona originally. More residential stuff. Have worked on some wine units in the past with these kind of components. Cut in cut out differential timers, did you find a open or damaged start winding in the compressor, or was there already the start cap in place when you arrived? That is always sign of previous compressor damage. Did you also find a damaged fan motor, like really high fla, full load amps on start up? Or a overload popped out in the fan motor from over heating? That relay burned up for a reason. Stuck bi metal leads internally perhaps from arching over time?

    • @hvactoolporn188
      @hvactoolporn188 Місяць тому

      So when I arrived breaker was tripped, the relay was shorting out, the fans were .2 a over fla and ohm on the compressor was within range. The new relay I received was stuck and would not cut power to the start cap.. so I was the one that flipped switch and popped the cap.. instead of going back to parts house 35 miles away I used the relay off hard start and cap as start components. The system ran fine and the amp draw was on the high side of the range but ok. Got down to temp. Management stated their repair guys have worked on it several times this year. Seen new filter and clean coils.. was wired correctly so not sure if the start cap was feeding back but didn't need to dig in further as I wired around that with the hard start.

  • @jamesmartin9740
    @jamesmartin9740 Місяць тому

    So why isnt the start cap wired to the common on the multi cap and herm avoiding the relay all together? Start caps are installed to bypass a bad start winding in the compressor. Weird that its power source is off a staging relay for the start capacitor going to a compressor. The multi cap should be wired off the common on the contactor for power to the compressor and fan. Is this a fan staging relay? What kind of system is this?

    • @hvactoolporn188
      @hvactoolporn188 Місяць тому

      No contactor on this type of system is a southern case art reach in deli case.

  • @jamesmartin9740
    @jamesmartin9740 Місяць тому

    😂blown start capacitor and switching relay. Overheated for sure with all that burned up wiring. Possible compressor start winding is open and the whole system is down. Cant tell if the multi capacitor is blown as well or burned up on the compressor side, possibly?

    • @hvactoolporn188
      @hvactoolporn188 Місяць тому

      So the relay was not opening power to the start cap. Is what made it overheat. Replaced it and that is when it blew all the black oil out... I wired a hard start with a relay and is good to go as it took that og relay out of the equation. It was a 240 system and the start cap was rated for 220v the hard start was rated for over 300 volts and gave me a relay to cut power to the start cap...

  • @ronnyrath816
    @ronnyrath816 Місяць тому

    How to you reset and clear the fault from memory?

  • @ronnyrath816
    @ronnyrath816 Місяць тому

    How you clear the light?

    • @hvactoolporn188
      @hvactoolporn188 Місяць тому

      Think that was turn on off and to clean 3 times to reset

  • @jcstroble91
    @jcstroble91 Місяць тому

    I’m not a fan of brown unless the coil is covered in grease so or caked up bad. I’ve noticed over the years it seems to deteriorate the coil prematurely.

    • @hvactoolporn188
      @hvactoolporn188 Місяць тому

      First time using it this year. Coil Was washed 3 weeks prior. 1 block from landfill so I figured if pressure didn't drop was going to pull the charge and use virgin gas.. pressure dropped to comfortable pressure. I was pleased

  • @LilDoraTheExplora
    @LilDoraTheExplora 2 місяці тому

    thank you for the tip, but why is this the case?

    • @hvactoolporn188
      @hvactoolporn188 2 місяці тому

      Just the visual of the growth of stuff on surfaces.. cubed ice is dirty.

  • @whodisnewphone
    @whodisnewphone 2 місяці тому

    No FUSE? lololol Love it.

  • @Tyler-cf8jl
    @Tyler-cf8jl 2 місяці тому

    5 tons isn't referring to the physical weight of it, it's the cooling capacity

  • @WhowereEpsteinsclients
    @WhowereEpsteinsclients 2 місяці тому

    Shame they bought a Trane. Stop selling it.

    • @hvactoolporn188
      @hvactoolporn188 2 місяці тому

      We didn't sell it.. just trying to clean up the mess...

  • @sp00-EKy
    @sp00-EKy 2 місяці тому

    You ever burn down someones business with that fuse bypass yet?

    • @hvactoolporn188
      @hvactoolporn188 2 місяці тому

      Nope but that is what insurance is for if it ever does happen...

  • @erin8207
    @erin8207 2 місяці тому

    I wonder if that car still there if I went with my dad to pick up my sister from work I probably could’ve seen the car

  • @marvinsellers4457
    @marvinsellers4457 2 місяці тому

    Buddy I’ve have the same problems gut it rewire as long as your warranty is not in place they do some really dumb things

  • @rvr1892
    @rvr1892 2 місяці тому

    VERY misleading title!!

    • @samanderson7745
      @samanderson7745 2 місяці тому

      Nope, it really isn't.

    • @hvactoolporn188
      @hvactoolporn188 2 місяці тому

      Not really any one that knows a thing or two about HVAC will get it. Typically you use a crane we pushed it off... Google how much does a 5 ton package unit weigh and most are 500 ish pounds...

  • @samanderson7745
    @samanderson7745 2 місяці тому

    People who don't understand how A/C units are measured in the archaic method. 5 tons is not the weight of the unit but is instead the amount of energy needed to melt a ton of ice, which is 12,000 BTU's, to cool the area. Therefore a 5 ton unit can remove 60,000 BTU's of heat per hour. Essentially the higher the tonnage the more cooling the unit will give.

    • @hvactoolporn188
      @hvactoolporn188 2 місяці тому

      Thank you! I was trying to think of a way to tell them the icp units or Grand air 5 ton package units only way around 500 lbs...

  • @Rojobean11
    @Rojobean11 2 місяці тому

    300 pounds not 10000

  • @timbear641
    @timbear641 2 місяці тому

    A ton my arse

  • @zealot777
    @zealot777 2 місяці тому

    Doubtful that thing is 5 tons...1 ton max. 🤦

  • @icecooler222
    @icecooler222 2 місяці тому

    You can open that masterlock with *pause* another masterlock

  • @aethylus
    @aethylus 2 місяці тому

    Nah that one guy thats on youtube that knows every lock by name and serial number can open it in a second ..

    • @hvactoolporn188
      @hvactoolporn188 2 місяці тому

      Ask um how long it takes him to drive to Florida to open it for me...

  • @epicfail5707
    @epicfail5707 2 місяці тому

    grab that lock with some locking pliers and your fingers will thank you some day. Bolt cutters are fast on a lock like that.

  • @martydom666
    @martydom666 2 місяці тому

    Not faster tham lock picking lawyer.. next time just use a hammer or two wrenchs. As its also faster. 😅

  • @theslow6.495
    @theslow6.495 2 місяці тому

    No drop cloths Jesus

    • @hvactoolporn188
      @hvactoolporn188 2 місяці тому

      Hmmm would the drop cloths be used like a parachute?

  • @SodiumInduction-hv
    @SodiumInduction-hv 2 місяці тому

    what the fuck is this channel name-

  • @claytondouglas2703
    @claytondouglas2703 2 місяці тому

    Swamp coolers are my favorite to kick off roofs.

    • @hvactoolporn188
      @hvactoolporn188 2 місяці тому

      I did a package unit today. The thud is really satisfying.

  • @user-yz1hv7oo6x
    @user-yz1hv7oo6x 2 місяці тому

    Oops wrong unit😊