Rooftop Units explained - RTU working principle hvac

Поділитися
Вставка
  • Опубліковано 11 січ 2025

КОМЕНТАРІ • 106

  • @EngineeringMindset
    @EngineeringMindset  6 років тому +15

    ⚠️ *Found this video super useful?* Buy Paul a coffee to say thanks: ☕
    PayPal: www.paypal.me/TheEngineerinMindset

  • @cameron3991
    @cameron3991 3 роки тому +13

    I'm a commercial hvac tech and your videos are amazing keep up the good job! I know guys that are in our apprenticeship class use your videos a lot! Nobody makes commercial hvac videos like this.

  • @stourleykracklite7663
    @stourleykracklite7663 4 роки тому +2

    As far as background music goes, this video is the best. Because it actually accomplishes something, namely a lively air in terms of selection and volume that helps the viewer focus on the speaker. Woe to those viewers who have been subjected to videos featuring video makers' favorite music. Because, well, they have have bad taste in music. And, as all who have such taste, they like it loud.

  • @wiserdaley2191
    @wiserdaley2191 4 роки тому +5

    I'm thankful for smart 👍 folks like you. I pretty much attend school on your channel.

  • @Saturdayz_In_The_Fall
    @Saturdayz_In_The_Fall 5 років тому +10

    I love assembling air handling units especially the rooftop units for Nortek Air Solutions I do my best to make sure that no water can leak through

  • @EngineeringMindset
    @EngineeringMindset  5 років тому

    Learn how *AIR HANDLING UNITS* work here ➡️ ua-cam.com/video/KCiv8IAUkh8/v-deo.html

  • @siranton14
    @siranton14 2 роки тому +1

    these videos are so good. Simple, straight forward and easy to understand .

  • @NeoEon
    @NeoEon 7 місяців тому

    Subscribed. Excellent HVAC theory. I know all this, but it was a quick refresher on RTU's and reminded me of important principles. Thank you!

  • @edunewton1386
    @edunewton1386 5 років тому +3

    A packaged air conditioning means an AHU unit with an inbuilt cooling unit ( that is no attached component such as chillers). This Air Handling Unit cools the air and sends this cooled air through a defined route duct work. The returned air is leaves the building through a defined route duct work to the exhaust channel in the AHU unit.

  • @georgewashington7863
    @georgewashington7863 6 років тому +6

    I'm working on a rooftop unit as we speak, found out the economizer is bad/ much appreciated
    👍🌟🌟🌟🌟🌟

  • @redsquirrelftw
    @redsquirrelftw 5 років тому +6

    When you mentioned the grid to stop animals and debris from entering it reminded me of one of our units at work that failed in a really weird way. They never figured out the cause so not sure if it has to do with something that got in but basically the main blower shaft was bent and it started to oscillate. The bend got worse and worse and it was basically shaking the whole building! We could hear various "tick tick tick" vibrations in the ceiling in random parts of the office, just from the false ceiling and light fixtures etc, and thought it was odd but did not think much of it. This got worse until one of us realized there was a really intense pulsating feeling on the 2nd floor. It was almost like a powerful subwoofer feeling and it felt different depending where you stand. The unit was in that room on the roof cooling that room. Supposedly the vibrations could be felt even outside the building at one point. The shaft that was bent was several inches in diameter, they still have no idea what happened, but it's fixed now. As a side note, getting parts from Carrier is like pulling teeth... They sent the wrong parts at least 3 times.

  • @richarddorr32
    @richarddorr32 5 років тому +8

    A packed unit is a unit that contains all of the system components in one unit. In a home the evaporator is inside while the condenser is outside. In a packed unit all of the components are inside of one unit, like in a RTU.

  • @abdelilahchichou2412
    @abdelilahchichou2412 6 років тому +6

    very well explained.
    RTU also used a Hot water heat chilled AC, would be great if you can make a video about it

  • @domovoikuzmich9695
    @domovoikuzmich9695 2 роки тому +1

    Thank you for this video! You are the best.

  • @Tyler-Woody
    @Tyler-Woody 2 роки тому

    Great video!!! Easy to follow along and understand . Great visuals and great pace . Thank you for the content

  • @franckjeanfrancois1677
    @franckjeanfrancois1677 Рік тому

    found this video very instructive

  • @bhushanpawar8855
    @bhushanpawar8855 6 років тому +5

    Excellent explanation..really impressive

  • @celtongerilla6595
    @celtongerilla6595 5 років тому +2

    Thank you! Great and helpful video for us - a young aspiring students.

  • @joanbea3902
    @joanbea3902 5 років тому +1

    Thank you it is clear and easy to understand

  • @zjfrancisco6882
    @zjfrancisco6882 5 років тому +2

    Package ac unit is a combined unit, it is the bigger version of Window type ac. Only the difference is.. It is connected to a duct work. Correct me if I'm wrong. Thanks..

  • @KingKrilly
    @KingKrilly 6 років тому +4

    You are amazing !!! THANK YOU

  • @stevenmartin2217
    @stevenmartin2217 4 роки тому +1

    Very useful video.

  • @satratey
    @satratey 6 років тому +2

    Thank you for the great video, sir. When I saw a belt drive blower watching your video, one question came in my mind. Where do we use a belt drive blower; where do we use direct drive blower?

    • @EngineeringMindset
      @EngineeringMindset  6 років тому +4

      It used to come down to space. It was more compact to place the motor on a belt drive. Now it comes down to money. Direct drive is more expensive but more efficient. Belt drive is cheaper to buy initially but more expensive to run because it's less efficient and required more maintenance and spare.

    • @satratey
      @satratey 6 років тому +1

      @@EngineeringMindset Thank you, Sir.

  • @issaabdulganiyu5728
    @issaabdulganiyu5728 2 роки тому

    Thank you it is clear and easy to understand, but made me remember our ahu that is not cold when we on it, can thermostat on actuator be reset

  • @gulnozkhojaabbos5646
    @gulnozkhojaabbos5646 4 роки тому +1

    How u can be sure that exhaust air is going to different direction but not to fresh air blower and distribute the very bad smell into the flats. I am suffering with this issue, specially in Summer in Dubai. Do u know how long lasts Summer in Dubai? Exhaust air and fresh air can’t be in the same side and over each other, weird construction. Look at the grid which stops the front air and collect the air from exhaust air.
    Thank u for this video, it helped me to understand where that bad smell is coming from

  • @grantjohnson880
    @grantjohnson880 2 роки тому

    Great video!

  • @FishingwithChris-u4i
    @FishingwithChris-u4i 3 роки тому

    I love painting unit like that!

  • @MrKelly-ll1lx
    @MrKelly-ll1lx 4 роки тому +1

    Thank you! Very helpful!

  • @Zeddify
    @Zeddify Рік тому +1

    A packaged unit is a type of AC unit which houses the condenser unit and air handler together.

  • @kevinpoulet149
    @kevinpoulet149 6 років тому +2

    Can you please make a video on equal friction and/or static regain calculations, including transition pieces and a wye (y) junction in the example. I’m taking a ventilation systems class now and this video would help soo much

  • @seattlebest79
    @seattlebest79 Місяць тому

    I’m just wondering, do you think a cold weather or temperatures can affect the performance of the RTU? Because ours is keep tripping the power switch. Thanks

  • @redsquirrelftw
    @redsquirrelftw 5 років тому +1

    I've seen some units that have an inside unit, which will have a full cooling cycle with compressor, and then will have an outside unit which will also have another compressor and cooling cycle, and there is glycol lines going between them. Essentially the glycol is used to cool the condenser and compressor in the indoor unit. What is the advantage of this vs just having a split system? Is it because a refrigeration loop has a limited working distance and the glycol lines can go further?

  • @clements.2345
    @clements.2345 5 років тому +1

    Can a RTU installed in a sloped roof (1:100)? How efficient would that be? It seems to me that it will be impact the flow air and liquid in the unit.

    • @scotteckart1401
      @scotteckart1401 3 роки тому

      A flat (perpendicular to the ground) mechanical curb could installed and supported on the the sloped roof, that way the RTU itself would be flat. But as long as the ducts connected to the unit into the building are where they need to be, there wouldn't be any issue with the air flow and refrigerant flow inside the unit if it were sloped. The refrigerant is being pumped around and so it would flow no problem.

  • @IngDzib
    @IngDzib 3 роки тому

    Thank you Paul

  • @felixfernandez442
    @felixfernandez442 5 років тому +1

    EXCELLENT INFORMATION

  • @leftenantthunder
    @leftenantthunder 3 роки тому

    fantastic video

  • @manojillangasooriya3590
    @manojillangasooriya3590 5 років тому +4

    thanks mate. I did a small paypal contribution too.

  • @mukeshram3587
    @mukeshram3587 4 роки тому +1

    Thank you sir helpful

  • @b.Ivey85
    @b.Ivey85 3 роки тому +1

    Can you do a video about high, medium and low pressure systems and their different applications?
    Clean air systems would be a great topic also medical,lab and food filtration!
    Grease duct and hoods as well

    • @b.Ivey85
      @b.Ivey85 3 роки тому

      😂 i see this comment being like the Vince McMan meme 🤣🤣🤣

  • @ting2732
    @ting2732 4 роки тому +1

    I am not sure if you have answered this, but what's the difference between a RTU and Dedicated Outdoor Air System (DOAS)?

  • @twojhjjj
    @twojhjjj 6 років тому +7

    Why did you choose the garden state plaza in Paramus NJ for the rooftop? I know that roof.

    • @EngineeringMindset
      @EngineeringMindset  6 років тому +3

      It was completely by chance. I zoomed in on Google maps and there happened to be RTU's there so I recorded it. Small world huh.

    • @mb7762
      @mb7762 4 роки тому

      Haha good eye. I live in bergen county.

  • @DrWenChannel
    @DrWenChannel Рік тому

    How to apply the right coating for anti-corrosion for rooftop units, especially for ducts exposed on the rooftop? Thanks!

  • @jimmyjonnew9102
    @jimmyjonnew9102 2 роки тому

    Do you guys have a video about makeup air units specifically?

  • @harbardtan596
    @harbardtan596 8 місяців тому

    thank you for the info.

  • @patrickfarrell7753
    @patrickfarrell7753 6 років тому +2

    Is there a fan on the return air or does the suction from the supply air fan do both? Thanks!

    • @EngineeringMindset
      @EngineeringMindset  6 років тому

      Some units will have a fan there, some will use the suction side. Depends on the design and the building.

  • @drjny
    @drjny 5 років тому +1

    The first RTU shown with only outside air is called a dedicated outside air system or DOAS.

  • @ansaruLhaQ18
    @ansaruLhaQ18 6 років тому +2

    Can u please explain what is decoupler line in primary and secondary pumps of chilled water

  • @afrog3569
    @afrog3569 Рік тому

    Awesome info

  • @laxkid6783
    @laxkid6783 2 роки тому

    As someone who is looking to get into hvac and needing training and nate certification how would yall recommend going about doing this.

  • @markyangson9188
    @markyangson9188 Рік тому

    We will about to Do HVAC on a 600 sqm Disco club can you advise what to do about HVAC? Do we need a RTU and Split type aircons?

  • @murtajabeg6801
    @murtajabeg6801 5 років тому +1

    Sir you explain about the valve of ahu

  • @sillywaiii
    @sillywaiii 6 років тому +4

    Hey bro, could you make a video for explaining the electric wiring connection in a typical chiller during a start-up process. Thanks.

    • @EngineeringMindset
      @EngineeringMindset  6 років тому +1

      We have one on chiller controls ua-cam.com/channels/k0fGHsCEzGig-rSzkfCjMw.htmlvideos

  • @hacker2ish
    @hacker2ish 6 років тому +2

    Should call your channel the refrigeration mindset

  • @hankuraj9892
    @hankuraj9892 3 роки тому

    Very useful

  • @l.crossjr
    @l.crossjr 6 років тому +2

    Any videos on chiller controls?

  • @Epicscrewdriver45
    @Epicscrewdriver45 Місяць тому

    Package Air Condition mean both ahu and cdu are both in one system

  • @nadeeshdhanushka1793
    @nadeeshdhanushka1793 Рік тому

    Can you explain about mark-up air?

  • @edunewton1386
    @edunewton1386 5 років тому +1

    question: don't we have a packaged AHU that are not installed on rooftops? If we do kindly give an example, please

    • @redsquirrelftw
      @redsquirrelftw 5 років тому

      A lot of them are installed outside the building on the ground, then have two ducts going into the wall. I think they basically work the same way. My church has one. I think this is typical for buildings that don't have a flat roof as there is no way to install it on the roof. Also less chance of leakages. A roof top unit is harder to install properly as if you don't seal things right you can get leaks.

  • @AKaufman
    @AKaufman 3 роки тому

    Thank you.

  • @vinodasokan8056
    @vinodasokan8056 3 роки тому

    Where does the cooling coil get the water from?

  • @khattakjani5663
    @khattakjani5663 6 років тому +2

    Helo sir . I hope you will be good and fine. Make a video about pipes welding because the welding is also play important role in chiller water pipes.

  • @JosckyPambu
    @JosckyPambu Рік тому

    Salut ! Mon air handling unit ne fonctionne pas bien,mais le tension est normal

  • @elangz9201
    @elangz9201 6 років тому +1

    Sir can you make a video about economizer? Im struggling to see how economizer can be installed to an RTU so it can provide free cooling. Isnt traditional RTU can also allow 100 percent of cool outside air to pass in order to achieve free cooling? Thank you sir any answer will be appriciated

  • @jaysonteodosio3000
    @jaysonteodosio3000 5 років тому +2

    Are RTU direct or indirect cooling systems?

    • @augusto0o0
      @augusto0o0 5 років тому

      This is something I was asking myself. If I'm not mistaken, they're direct expansion systems. And to me this means the evaporator unity is the single coil connected to the refrigeration system, but out of its chamber, according to the video.

  • @RealGigaMind
    @RealGigaMind Рік тому

    Is this also called packaged rooftop air conditioner?

  • @andreaspandega6319
    @andreaspandega6319 3 роки тому

    If the exhaust placed directly under the intake (which is facing down because of the air hood), wouldn't some of the exhaust air get sucked into the intake?

  • @georgewashington7863
    @georgewashington7863 6 років тому +2

    Can you do video on economizers

    • @EngineeringMindset
      @EngineeringMindset  6 років тому

      Have you check out our video on AHU's and chiller terminology, there's some info in there too

    • @georgewashington7863
      @georgewashington7863 6 років тому

      @@EngineeringMindset ok I'll review them

  • @DailYxDosE
    @DailYxDosE 2 роки тому

    4:19 shouldn’t the flow be reversed?

  • @scottfrench4985
    @scottfrench4985 4 роки тому +1

    a package unit it condenser and evaporator in the same unit.

  • @gzealous4456
    @gzealous4456 3 роки тому

    Only part I'd change is the purpose of access panels. I've yet to see an engineer out in the field doing the maintenance.

  • @mohitpandurangwaghade5
    @mohitpandurangwaghade5 5 років тому +1

    Sir if don't mind, can I use your video animation in my UA-cam video, to explain it in other languages in my country. ...

    • @EngineeringMindset
      @EngineeringMindset  5 років тому +4

      No thank you. We are working on languages ourselves and do not want our viewers going to another channel to view our content. To run a successful channel you must make original content yourself.

  • @amirhoseinsamiee638
    @amirhoseinsamiee638 2 роки тому

    tanks

  • @LuizDahoraavida
    @LuizDahoraavida 3 роки тому

    inb4 dassault systems fluid simulations

  • @buildingstatux7720
    @buildingstatux7720 5 років тому +1

    Solar water heater and solar energy please

    • @EngineeringMindset
      @EngineeringMindset  Рік тому

      Seen our new video on HOW SOLAR PANELS WORK in detail ua-cam.com/video/Yxt72aDjFgY/v-deo.html

  • @steven20919
    @steven20919 2 роки тому

    Now I 100% know how inefficient these units really are.

  • @DorisEllis-q7z
    @DorisEllis-q7z 4 місяці тому

    Bernier Ferry

  • @savannaskinner239
    @savannaskinner239 3 місяці тому

    I need to but I almost can't watch this video because the background music is so distracting

  • @shyamkumar2514
    @shyamkumar2514 2 роки тому

    Michael duties or otherwise called also p a c u indoor and outdoor area Vikram status Pondicherry

  • @shahnwazansari831
    @shahnwazansari831 3 роки тому

    Please dubbing in Hindi language is videos