There is a valve before the pressure switch, by closing that lo alarm gets activated. Relief valve is pressure tested after removing from the compressor and by using hydraulic or pneumatic pressure. Should not be pressure tested by closing the discharge valve of compressor.
Awesome
Why reciprocating used onboard ship
brother, how can i test air compressor LO pressure low? and how relief v/v test should be done
By just lowering the pressure setting
i will try to cover in part 2
There is a valve before the pressure switch, by closing that lo alarm gets activated. Relief valve is pressure tested after removing from the compressor and by using hydraulic or pneumatic pressure. Should not be pressure tested by closing the discharge valve of compressor.
Hello sir one new compressor 1 hour oil contamination fresh water mix in oil . But cooling system in sea water I replace air intake . Fix new .