Unboxing the Tomzn Smartest WIFI Device of the Year Meter for home and solar system DDS238-4 IVAPT

Поділитися
Вставка
  • Опубліковано 20 гру 2024

КОМЕНТАРІ • 30

  • @rehmanschools
    @rehmanschools Рік тому +1

    بہت زبردست ڈیوائس ہے اور بھائی کا طریقہ کار بھی بہت تعاون والا ہے۔ میں نے منگوائی ہے۔۔زبردست

  • @qaritariq3065
    @qaritariq3065 Рік тому +1

    ماشاءاللہ بھاٸ زبردست

  • @usmanpopalzai6137
    @usmanpopalzai6137 3 місяці тому

    Bhai yeh aik dafa over voltage surge pay yeh jal jata hay ya Bach jata hay ???

    • @BijliWalaBhai
      @BijliWalaBhai  3 місяці тому

      @@usmanpopalzai6137 bhai surge se bachne k liye spd use kren
      inki voltage bearing capacity 350v hai
      oper anege to jal jaygi

  • @ajmalhameed1458
    @ajmalhameed1458 Рік тому

    The explanation is great, but one important aspect that seems to be missing is the utilization of historical data, such as displaying hourly records of energy consumption for the past several months. Is this information is also available in the App?? If can be demonstrate that would be great.

  • @muzammel111
    @muzammel111 8 місяців тому

    AA sir please guide about 80A per phase means each phase max support 80A but overall capacity of this meter is 80A right? Or 80x3 = 270A ?

  • @malikisrar2680
    @malikisrar2680 Місяць тому

    Is me double input nahi hai tu kaise 2 meter connect kar sakty hain shifting k leye

    • @BijliWalaBhai
      @BijliWalaBhai  12 днів тому

      bhai 2 meters connect nahi honge kisne keh dia meters 2 meters connect k liye hai?

  • @Universal_Bro
    @Universal_Bro 5 місяців тому

    Can we connect to phone's wifi/hotspot without having a wifi router?

  • @OMM717
    @OMM717 Рік тому

    There is a problem in the three phase meter if there is a one link down(voltage lower than 170V) from transformer, it stops incoming/outing power supply on all three phases. I tried to bypass all the faults including mismatch voltage/current, under voltage fault etc. but the meter shows "miss phase alarm" though my inverter is connected on other phase. I paid 21k and bought from you and asked you for the solution on WhatsApp but you didn't answered me brother. Do you have some solution for this otherwise it is more headache to call lineman to fix the link specially when someone is abroad

    • @BijliWalaBhai
      @BijliWalaBhai  Рік тому

      mere mohtaram bhai agar apka 1 phase down ho raha hai or whole device trip kr rahi hai to na isme mera koi kasoor hai na he device ka kasoor hai or na humne rule he yehi hota hai
      ab apka transformer agar low volts de raha 1 phase per or apke wapda k issues han to isme mera ya device bnany wali company ka kya kasoor hai?
      apne 21k device k pay kiye han sir device rules ka ccording chal rahi
      ap aborad han apke wahan transformer k issue ay to wifi device walay se rabta krenge ya electricity walay se?

    • @BijliWalaBhai
      @BijliWalaBhai  Рік тому

      also please keep in mind i have answered many times but if you have problems regarding wapda then what you want from us to solve your wapda transformer issues
      does it make sense brother?
      all 3 phase devices meters/protectors / other devices works on the same principle if 1 phase will down whole device trips its not device fault its a basic rule where safety triger. so please ask your wapda line man to solve voltages issue.
      thank you

    • @OMM717
      @OMM717 Рік тому

      @@BijliWalaBhai Usama bhai apka koi kasoor nhi hai, mai tu sirf device k bare mai baat kar raha ho.
      Device ka kasoor hai q k hamare gharo mai 3-phase devices(like motors waghera) tu nhi lagi hoti sare single phase device hoti hai(like tv,fridge,motor, bulbs etc.) tu agar barish k waja c ek phase per voltage kam hojye tu es ka ye matlab tu nhi k ap 3phase he band karle, r device ma undervoltage ko bypass karne ka option mention hai lkn wu kaam nhi kar raha hai....
      Mai behar rehta ho, yaha kabi light jati he nhi hai, pakistan ma her dosre roz koi na koi issue hota ha lkn agar ek phase mai b issue ajaye tu ye device ek headache ban jata ha, i shared my experience baki device is still working and i am still using it, I have to either install manual changeover switch in parallel in order to bypass it incase there is an issue from the grid Or i have to replace this device.

    • @OMM717
      @OMM717 Рік тому

      @@BijliWalaBhai yes you answered me many times but you avoid this issue when i wrote you
      I think you are wrong, You can still use two wire(one phase and neutral) with three phase meter without connecting the other two phase wires. You can use three phase meter as a single phase meter. While for safety rules and devices, there is an option in the device "Alarm Switch" and "Opening switch" which can be enbale/disable but this option is not working for "Undervoltage Protection Setting"

    • @wakhan083
      @wakhan083 Рік тому

      ​@@OMM717 Use phase selector changeover...

  • @abidjaffry5127
    @abidjaffry5127 Рік тому

    Good information,thanks

  • @ashrafthemariner1
    @ashrafthemariner1 Рік тому

    Price pls??

  • @mumtazrizvi7118
    @mumtazrizvi7118 8 місяців тому

    السلام علیکم
    بھائی میرے گھر چار کے وی کا سولر سسٹم لگا ہوا ہے اور میرے دو میٹر بھی ہیں واپڈا کےاور میں ان کے یونٹ کنٹرول کرنا چاہتا ہوں تو مجھے کون سا سوئچ چاہیے اگر یہی جو ویڈیو میں اپ دکھا رہے ہیں تو اس میں کلر ڈسپلے والا بھی ہے کوئی تو مجھے بتا دیں وہ مجھے چاہیے
    شکریہ

  • @Universal_Bro
    @Universal_Bro 5 місяців тому

    Timer should be inside instead of dependent upon the Internet,

  • @SMRG-jq9zd
    @SMRG-jq9zd Рік тому

    🇵🇰 پاکستان زندہ باد 🇵🇰

  • @irfanshafiq1353
    @irfanshafiq1353 Рік тому

    Nice dev

  • @ibnealiabidi7292
    @ibnealiabidi7292 2 місяці тому

    Best

  • @imola22000
    @imola22000 9 місяців тому

    dear, Too bad I don't understand your language,
    you will surely have said many important things