El bloque lógico que une a los bloques "AND - CB Close enable logic" y al bloque lógico "NOT - P543_Block" mostrados en el min 16:22; debería ser un bloque lógico "AND" , no un bloque "OR" , esto debido a lo indicado en el min 1:43 - "block CB close enable".
How to detect if there is any break in FO cable and loss of signal from IED to IED ( when in redundant system, IED still be abale to communicate through another cable)
You covered in all videos how the GOOSE message is send from ABB,Micom,Siemens relays and GOOSE message is received to ABB, Siemens but GOOSE receiving in Micom relay is not available in any other videos. If possible teach us how to receive GOOSE message in Micom relays.
It was really useful. But u have missed some parts where a proper explanation was required for proper understanding by new engineers. But those parts were ruined by the loud background music. Kindly stop the music and explain more things line by line
@@baranitech it’s for goose from micom to abb right? I mean how about goose from abb to micom, I’ve tried export cid file from pcm600 for abb and imported to s1 agile for micom subscriber, but it doesn’t work
@@choskinwest First export micom CID file from mcl and import to IEC on ABB pcm600 do goose send and then export IEC file from abb . this export cid has to import to micom mcl
Very nice explanation, Sir please prepare a video on trip block on inrush from micon P642 to C264 using goose communication.
Will try for you
El bloque lógico que une a los bloques "AND - CB Close enable logic" y al bloque lógico "NOT - P543_Block" mostrados en el min 16:22; debería ser un bloque lógico "AND" , no un bloque "OR" , esto debido a lo indicado en el min 1:43 - "block CB close enable".
@16:22 it should be AND gate . i have done mistake
Awesome.....Can you upload video regarding busbar concept..
Useful stuff!
Sir make video for c264 GE make and use of CET software
i will try
Make video of how can replace p444 relay with old relay mcl
good topic i will study first and then i will try to make
How to detect if there is any break in FO cable and loss of signal from IED to IED ( when in redundant system, IED still be abale to communicate through another cable)
i don't know how to find but i will try to get solution for your ans soon.
You covered in all videos how the GOOSE message is send from ABB,Micom,Siemens relays and GOOSE message is received to ABB, Siemens but GOOSE receiving in Micom relay is not available in any other videos. If possible teach us how to receive GOOSE message in Micom relays.
soon i will make
Thanks
Welcome
Communication mode from micom to abb through fo cable are ethernet how to use that
we can use fiber optical also.
It was really useful. But u have missed some parts where a proper explanation was required for proper understanding by new engineers. But those parts were ruined by the loud background music. Kindly stop the music and explain more things line by line
How to do goose from ABB to micom ? ABB as publish and micom as subscriber?
create IEC file on micom and import to ABB project file for doing Goose cofiguration
@@baranitech it’s for goose from micom to abb right?
I mean how about goose from abb to micom, I’ve tried export cid file from pcm600 for abb and imported to s1 agile for micom subscriber, but it doesn’t work
@@choskinwest First export micom CID file from mcl and import to IEC on ABB pcm600 do goose send and then export IEC file from abb . this export cid has to import to micom mcl
@@baranitech okay, I’ll try it, thanks
Sir I want to learn relay. Basic and all types relay training center please send me location are name of institute
1. voltech
2.V EQUAL IR
Sir how make CID file for micom relay and if i want comminicate all relay from ethernet switch how to ip address set please make one tutorial for us.
Plz don't add the background music... It's ruining the video
@@baranitech can u share the link
Please don't add such irritating music in video 😢
sorry