C.S.I. s.r.l. - How to fill bladder tank

Поділитися
Вставка
  • Опубліковано 2 лют 2025

КОМЕНТАРІ • 22

  • @nickgrnr
    @nickgrnr 3 роки тому +1

    It's great to see how it's done in other parts of the world. I'm in Texas and I use a vacuum to pull all of the air out of the shell side and pull the bladder to the tank walls.

    • @voyager3355
      @voyager3355 3 роки тому

      yes that's also quite often to use vacuum which may create the same effect. but we also travel to other parts of the word where may be a compressor or air blower can be easily found instead of a vacuum pump...:D thanks. regards.

  • @alessiogravina4521
    @alessiogravina4521 3 роки тому +1

    Video istruttivi,bravi mettetene altri che c'è sempre da imparare

  • @magicworld1655
    @magicworld1655 2 роки тому

    Very instructive, many thanks

  • @adamnaj2611
    @adamnaj2611 4 роки тому +1

    V. Good explanation .. Thank you

  • @nguyenthanhhai7249
    @nguyenthanhhai7249 2 роки тому

    Thanks so much

  • @vadivelkasinadhan6687
    @vadivelkasinadhan6687 3 роки тому

    Good instruction

  • @kamaranfattah1578
    @kamaranfattah1578 4 роки тому +1

    this filling procedure is that same for horizontal bladder tank?

    • @voyager3355
      @voyager3355 4 роки тому

      yes the procedure is approximately the same! thanks.

    • @kamarankhoshnaw4097
      @kamarankhoshnaw4097 4 роки тому

      @@voyager3355 thanks for kind your answer, And how to refill again when I used an amount of foam from total capacity.

    • @voyager3355
      @voyager3355 4 роки тому

      @@kamarankhoshnaw4097
      1- isolate vessel from fire protection system.
      2- Open the water drainage valve let the pressure escape from drainage but do not drain all water. keep some water inside. Close water drain valve.
      3- Open top air purge valves on top both at water and foam sides and keep them open. May be it would be really good to attach a flexible hose to upper water air purge side to drain the water.
      4- Attach your foam pump to foam loading port.
      5- Let the same quantity of water escape from top as much as you load foam concentrate.
      6- When you see foam goes out from the foam vent, it means you have finished loading.

    • @kamarankhoshnaw4097
      @kamarankhoshnaw4097 4 роки тому

      @@voyager3355 thank you very much, all foam bladder tanks we have from site C.S.I. s.r.l. horizontal foam bladder tank . could you send me your mobile number for help me and more inform quickly when i needed for your brand bladder tanks.

    • @voyager3355
      @voyager3355 4 роки тому +1

      @@kamarankhoshnaw4097 please send a mail to me, i will contact you ufficiotecnico@csiantincendio.it

  • @mousab07
    @mousab07 3 роки тому

    I think you will show us the level indicator after finish filling the water.

  • @imranhadi8505
    @imranhadi8505 Рік тому

    Sir there is 3500 litres capacity of bladder tank , how many litres of foam 3%AFFF concentration is required to be filled in the tank ?

  • @imranmahmood3003
    @imranmahmood3003 3 роки тому

    Sir,
    We are designing a foam base deluge sprinkler system as we have combustible solid and liquid material tanks.
    So, my question is,
    How many no. of open type sprinklers should be on 1" or 2" line for Ordinary Hazard Group 2 and what should be the density of the water used for this system.?

    • @CSI-srl
      @CSI-srl  3 роки тому

      Dear Imran, please contact our tecnical office: ufficiotecnico@csiantincendio.it

    • @nickgrnr
      @nickgrnr 3 роки тому

      The density depends on the hazard. And the amount of nozzles depends on the hydraulic calculations.

  • @amineamine-tv3xg
    @amineamine-tv3xg Рік тому

    What are the specifications of the foam concentrate pump please

    • @CSI-srl
      @CSI-srl  Рік тому

      Thank you for your interest, please contact our tecnical office: ufficiotecnico@csiantincendio.it

  • @fatima-zahrabousselham3847
    @fatima-zahrabousselham3847 3 роки тому

    I need a contact email to send inquiry to your sales departement

    • @CSI-srl
      @CSI-srl  3 роки тому

      Dear Fatima, our sales department is always available at: katia.clenzi@csiantincendio.it